Standard Specification for Sheet Radiant Barriers for Building Construction Applications

SCOPE
1.1 This specification covers the general physical property requirements of radiant barrier materials for use in building construction. The scope is specifically limited to requirements for radiant barrier sheet materials that consist of at least one surface having a far-infrared emittance of 0.1 or less, such as metallic foils or metallic deposits mounted or unmounted on substrates.  
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.  
1.3 The following safety hazards caveat pertains only to the test methods (Section 10) described in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Oct-2000
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1313-00 - Standard Specification for Sheet Radiant Barriers for Building Construction Applications
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 1313 – 00
Standard Specification for
Sheet Radiant Barriers for Building Construction
1
Applications
This standard is issued under the fixed designation C 1313; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope D 2261 Test Method for Tearing Strength of Fabrics by the
3
Tongue (Single Rip) Procedure
1.1 This specification covers the general physical property
D 3310 Test Method for Determining Corrosivity of Adhe-
requirements of radiant barrier materials for use in building
4
sive Materials
construction. The scope is specifically limited to requirements
E 84 Test Method for Surface Burning Characteristics of
for radiant barrier sheet materials that consist of at least one
5
Building Materials
surface having a far-infrared emittance of 0.1 or less, such as
E 96 Test Methods for Water Vapor Transmission of Mate-
metallic foils or metallic deposits mounted or unmounted on
2
rials
substrates.
2.2 Other Standards:
1.2 The values stated in SI units are to be regarded as the
TAPPI Standard T 512 om-86: Creasing of Flexible Pack-
standard. The values given in parentheses are for information
6
aging Material Paper Specimens for Testing
only.
1.3 The following safety hazards caveat pertains only to the
3. Terminology
test methods (Section 10) described in this specification. This
3.1 Definitions—For definitions of terms used in this speci-
standard does not purport to address all of the safety concerns,
fication, refer to Terminology C 168.
if any, associated with its use. It is the responsibility of the user
3.2 Definitions of Terms Specific to This Standard:
of this standard to establish appropriate safety and health
3.2.1 radiant barrier—a low emittance (0.1 or less) surface
practices and determine the applicability of regulatory limita-
used in the construction of a radiant barrier system.
tions prior to use.
3.2.2 radiant barrier system (RBS)—abuildingconstruction
2. Referenced Documents consisting of a radiant barrier bounded by an open air space.
2.1 ASTM Standards:
4. Ordering Information
C 168 Terminology Relating to Thermal Insulating Materi-
2 4.1 Prior to purchase, for sampling and acceptance proce-
als
dures, Criteria C390 may be agreed to by purchaser and
C 390 Criteria for Sampling and Acceptance of Preformed
2 manufacturer.
Thermal Insulation Lots
4.2 Specify the width and total area to be installed.
C 1158 Practice for Use and Installation of Radiant Barrier
2 4.3 Specify any special markings.
Systems (RBS) in Building Construction
C 1338 Test Method for Determining Fungi Resistance of
5. Materials and Manufacture
2
Insulation Materials and Facings
5.1 Sheet radiant barrier materials shall consist of low
C 1371 Test Method for Determination of Emittance of
emittance surface(s) that may be in combination with any
Materials Near Room Temperature Using Portable Emis-
2 substratesandadhesivesrequiredtomeetthespecifiedphysical
someters
material properties.
1
This specification is under the jurisdiction of ASTM Committee C-16 on
Thermal Insulation and is under the direct responsibility of Subcommittee C16.21
3
on Reflective Insulation. Annual Book of ASTM Standards, Vol 07.01.
4
Current edition approved Oct. 10, 2000. Published January 2001. Originally Annual Book of ASTM Standards, Vol 15.06.
5
published as C 1313–95. Last previous edition C 1313–95. Annual Book of ASTM Standards, Vol 04.07.
2 6
Annual Book of ASTM Standards, Vol 04.06. Available from TAPPI.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C 1313
6. Workmanship, Finish, and Appearance 7.2.7 Mold and Mildew— Fungal resistance of sheet radiant
barriersshallbetestedinaccordancewithTestMethodC 1338.
6.1 Sheet radiant barriers shall be manufactured, packaged
The samples are then examined visually under 53 magnifica-
and shipped in such a manner that, when received by the
tion for the extent of mold growth and for indications of
customer, they are suitable for installation in accordance with
deterioration. Evidence of mold growth beyond the inoculation
Practice C 1158.
area or delamination shall be cause for rejection.
7. Physical Requirements
8. Significance and Use
7.1 The low emittance materials shall conform to the
8.1 This specification recognizes that the effectiveness of a
physical properties as specified in Table 1 and local building
sheet radiant barrier is dependent on proper installation.
codes.
Practice C 1158 addresses use and installation of radiant
7.2 The following physical characteristic
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.