ASTM D7367-07
(Test Method)Standard Test Method for Determining Water Holding Capacity of Fiber Mulches for Hydraulic Planting
Standard Test Method for Determining Water Holding Capacity of Fiber Mulches for Hydraulic Planting
SIGNIFICANCE AND USE
The meaning of the test is related to the manufacturing and end use of the material, to determine characteristics of products. The water holding capacity of hydraulically applied mulches for hydraulic planting correlates directly with enhanced slurry and spray patterns by providing better soil/slurry binding ability and rate of seed germination.
SCOPE
1.1 This quantitative test method determines water holding capacity of fiber mulches, including wood, paper, and agriculturally derived and blended fiber mulches used for hydraulic planting.
1.2 The purpose of this test method is to provide a means of evaluating water holding capacity in fiber mulches. Product specimen is conditioned and weighed, saturated and re-weighed to determine water holding capacity. The water holding capacity is expressed as a percentage of increased weight after saturation. There are no known limitations to this test method. No range of concentrations/values have been determined. This test method is preferably performed in a laboratory.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D7367 − 07
StandardTest Method for
Determining Water Holding Capacity of Fiber Mulches for
Hydraulic Planting
This standard is issued under the fixed designation D7367; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 4. Summary of Test Method
1.1 This quantitative test method determines water holding 4.1 Productspecimenisconditionedandweighed,saturated
capacity of fiber mulches, including wood, paper, and agricul- andre-weighedtodeterminewaterholdingcapacity.Thewater
turally derived and blended fiber mulches used for hydraulic holding capacity is expressed as a percentage of increased
planting. weight after saturation.
1.2 Thepurposeofthistestmethodistoprovideameansof
5. Significance and Use
evaluating water holding capacity in fiber mulches. Product
5.1 The meaning of the test is related to the manufacturing
specimen is conditioned and weighed, saturated and re-
and end use of the material, to determine characteristics of
weighed to determine water holding capacity. The water
products. The water holding capacity of hydraulically applied
holding capacity is expressed as a percentage of increased
mulches for hydraulic planting correlates directly with en-
weight after saturation. There are no known limitations to this
hancedslurryandspraypatternsbyprovidingbettersoil/slurry
test method. No range of concentrations/values have been
binding ability and rate of seed germination.
determined. This test method is preferably performed in a
laboratory.
6. Apparatus
1.3 The values stated in SI units are to be regarded as the
6.1 203.2 mm (8 in.) diameter #8 sieve.
standard. The values given in parentheses are for information
6.2 203.2 mm (8 in.) diameter sieve pan.
only.
6.3 Large mixing bowl 5.5 L 6 (10 Pt 6) capacity.
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
6.4 Electronic gram scale or balance scale with a minimum
responsibility of the user of this standard to establish appro-
of 0.1 g resolution.
priate safety and health practices and determine the applica-
6.5 457 mm × 279 mm (18 in. × 11 in.) baking pan or tray
bility of regulatory limitations prior to use.
for draining.
2. Referenced Documents
6.6 KitchenAid mixer with dough kneader attachment
capable of 60 to 90 rpm on low setting (low rpms minimize
2.1 ASTM Standards:
damage to fibers).
D653Terminology Relating to Soil, Rock, and Contained
Fluids
7. Sampling and Testing Specimens
E11Specification forWovenWireTest Sieve Cloth andTest
7.1 Prepare specimen by separating 90 g of fiber from an
Sieves
undamaged bag or bale taking 1/3 from the top of the bag, 1/3
3. Terminology
from the middle of the bag and 1/3 from the bottom of the bag
(heterogeneous blends should be mixed at the same ratio by
3.1 Definitions—For common definitions of terms in this
weight, as manufacturer’s specifications to equal 30 g).
standard refer to Terminology D653.
7.2 Break the compressed fiber apart and allow to condition
at room temperature 23°C 6 2°C (73°F 6 4°F) and at a
ThistestmethodisunderthejurisdictionofASTMCommitteeD18onSoiland
Rock and is the direct responsibility of Subcommittee D18.25 on Erosion and
humidity level of 50% RH 610% for 24 h.
Sediment Control Technology.
Current edition approved July 1, 2007. Published July 2007. DOI: 10.1520/
D7367-07. The sole source of supply of the apparatus known to the committee at this time
For referenced ASTM standards, visit the ASTM website, www.astm.org, or is KitchenAid, P.O. Box 218, St. Joseph, MI, 49085, www.kitchenaid.com. If you
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM are aware of alternative suppliers, please provide this information to ASTM
Standards volume information, refer to the
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.