Standard Specification for Compacted Mineral-Insulated, Metal-Sheathed Cable Used in Industrial Resistance Thermometers

ABSTRACT
This specification establishes the requirements for compacted, mineral-insulated, metal-sheathed (MIMS) cables used to manufacture metal-sheathed, industrial resistance thermometers known as Resistance Temperature Detectors (RTDs). It covers the material requirements, significance and use, ordering information and basis for purchase, processing requirements, quality verification and test requirements, certification and reports, packaging, marking, and shipping.
SCOPE
1.1 This specification covers the requirements for compacted, mineral-insulated, metal-sheathed (MIMS) cables used to manufacture metal-sheathed, industrial resistance thermometers referred to in this document as Resistance Temperature Detectors or RTDs.  
1.2 The materials of construction include copper, nickel-clad copper, copper-45 % nickel (constantan), or nickel conductors, an austenitic stainless steel or nickel-chromium alloy sheath, and either magnesia (MgO) or alumina (Al2O3) insulation.  
1.3 The cable diameter is between 0.093 and 0.500 in. (2.33 and 12.70 mm) and contains between two and eight conductors, set in various design configurations and wire spacings.  
1.4 The values of temperature in this specification are based on the International Temperature Scale of 1990 (ITS-90).  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Apr-2013
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM E2821-13 - Standard Specification for Compacted Mineral-Insulated, Metal-Sheathed Cable Used in Industrial Resistance Thermometers
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:E2821 −13
Standard Specification for
Compacted Mineral-Insulated, Metal-Sheathed Cable Used
1
in Industrial Resistance Thermometers
This standard is issued under the fixed designation E2821; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
2
1. Scope 2.3 ASTM Standards:
A213/A213MSpecification for Seamless Ferritic and Aus-
1.1 This specification covers the requirements for
tenitic Alloy-Steel Boiler, Superheater, and Heat-
compacted, mineral-insulated, metal-sheathed (MIMS) cables
Exchanger Tubes
used to manufacture metal-sheathed, industrial resistance ther-
A249/A249MSpecification for Welded Austenitic Steel
mometers referred to in this document as Resistance Tempera-
Boiler, Superheater, Heat-Exchanger, and Condenser
ture Detectors or RTDs.
Tubes
1.2 The materials of construction include copper, nickel-
A269Specification for Seamless and Welded Austenitic
clad copper, copper-45 % nickel (constantan), or nickel
Stainless Steel Tubing for General Service
conductors, an austenitic stainless steel or nickel-chromium
A632Specification for Seamless and Welded Austenitic
alloy sheath, and either magnesia (MgO) or alumina (Al O )
2 3
Stainless Steel Tubing (Small-Diameter) for General Ser-
insulation.
vice
1.3 Thecablediameterisbetween0.093and0.500in.(2.33
B163Specification for Seamless Nickel and Nickel Alloy
and 12.70 mm) and contains between two and eight Condenser and Heat-Exchanger Tubes
conductors, set in various design configurations and wire
B167Specification for Nickel-Chromium-IronAlloys (UNS
spacings.
N06600, N06601, N06603, N06690, N06693, N06025,
N06045, and N06696), Nickel-Chromium-Cobalt-
1.4 Thevaluesoftemperatureinthisspecificationarebased
Molybdenum Alloy (UNS N06617), and Nickel-Iron-
on the International Temperature Scale of 1990 (ITS-90).
Chromium-TungstenAlloy (UNS N06674) Seamless Pipe
1.5 The values stated in inch-pound units are to be regarded
and Tube
as standard. The values given in parentheses are mathematical
B516SpecificationforWeldedNickel-Chromium-IronAlloy
conversions to SI units that are provided for information only
(UNS N06600, UNS N06603, UNS N06025, and UNS
and are not considered standard.
N06045) Tubes
1.6 This standard does not purport to address all of the
E344Terminology Relating to Thermometry and Hydrom-
safety concerns, if any, associated with its use. It is the
etry
responsibility of the user of this standard to establish appro-
E780Test Method for Measuring the Insulation Resistance
priate safety and health practices and determine the applica-
of Mineral-Insulated, Metal-SheathedThermocouples and
bility of regulatory limitations prior to use.
Thermocouple Cable at Room Temperature
E839 Test Methods for Sheathed Thermocouples and
2. Referenced Documents
Sheathed Thermocouple Cable
2.1 Thelatestissuesofthefollowingdocumentsformapart
E1137/E1137MSpecification for Industrial Platinum Resis-
of this specification to the extent specified herein. In the event
tance Thermometers
of a conflict between this specification and other specifications
E1652Specification for Magnesium Oxide and Aluminum
referenced herein, this specification shall take precedence.
Oxide Powder and Crushable Insulators Used in the
Manufacture of Base Metal Thermocouples, Metal-
2.2 Due to the similarity between Compacted MIMS Ther-
Sheathed Platinum Resistance Thermometers, and Noble
mocouple Cable and Compacted MIMS Cable, some Thermo-
Metal Thermocouples
couple ASTM Standards may apply.
1
This specification is under the jurisdiction of ASTM Committee E20 on
2
Temperature Measurement and is the direct responsibility of Subcommittee E20.03 For referenced ASTM standards, visit the ASTM website, www.astm.org, or
on Resistance Thermometers. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Current edition approved May 1, 2013. Published July 2013. DOI: 10.1520/ Standards volume information, refer to the standard’s Document Summary page on
E2821-13 the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E2821−13
3
2.4 ANSI Standard: 5.1.9 The Optional Clearance if applicable (see Fig. 1).
ANSI B46.1Surface Texture, Surface Roughness, Waviness
6. General Requirements
and Lay
6.1 MIMS RTD Cable—Cable shall be in accordance with
3. Terminology
this specification (see Fig. 2). Fig. 2 shows a cable with two
3.1 Definitions—ThedefinitionsgiveninTerminologyE344
conductors, but more than two conductors may be specified.
shall apply to this specification.
6.2 C
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.