Standard Specification for Sheet Radiant Barriers for Building Construction Applications

ABSTRACT
This specification covers the general physical property requirements of radiant barrier materials for use in building construction. The scope is specifically limited to requirements for radiant barrier sheet materials that consist of at least one surface, such as metallic foils or metallic deposits mounted or unmounted on substrates. Sheet radiant barrier materials shall consist of low emittance surface(s) that may be in combination with any substrates and adhesives required to meet the specified physical material properties. The following test methods shall be performed: surface emittance; water vapor transmission; surface burning characteristics; corrosivity; tear resistance; and adhesive performance.
SIGNIFICANCE AND USE
This specification recognizes that the effectiveness of a sheet radiant barrier is dependent on proper installation. Practice C1158 addresses use and installation of radiant barriers.
This specification identifies the material properties that are important for sheet radiant barrier products. When appropriate, values for the properties have been stated.
The user should consult the manufacturer about specific material properties are needed for a particular application.
Radiant barriers shall be free of dust or other contaminants to remain effective.
SCOPE
1.1 This specification covers the general physical property requirements of radiant barrier materials for use in building construction. The scope is specifically limited to requirements for radiant barrier sheet materials that consist of at least one surface having a far-infrared emittance of 0.1 or less, such as metallic foils or metallic deposits mounted or unmounted on substrates.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 The following safety hazards caveat pertains only to the test methods (Section 10) described in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Sep-2011
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1313/C1313M-11 - Standard Specification for Sheet Radiant Barriers for Building Construction Applications
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C1313/C1313M-11 - Standard Specification for Sheet Radiant Barriers for Building Construction Applications
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1313/C1313M – 11
Standard Specification for
Sheet Radiant Barriers for Building Construction
1
Applications
This standard is issued under the fixed designation C1313/C1313M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D2261 Test Method for Tearing Strength of Fabrics by the
Tongue (Single Rip) Procedure (Constant-Rate-of-
1.1 This specification covers the general physical property
Extension Tensile Testing Machine)
requirements of radiant barrier materials for use in building
D3310 Test Method for Determining Corrosivity of Adhe-
construction. The scope is specifically limited to requirements
sive Materials
for radiant barrier sheet materials that consist of at least one
E84 Test Method for Surface Burning Characteristics of
surface having a far-infrared emittance of 0.1 or less, such as
Building Materials
metallic foils or metallic deposits mounted or unmounted on
E96/E96M Test Methods for Water Vapor Transmission of
substrates.
Materials
1.2 The values stated in either SI units or inch-pound units
E2599 Practice for Specimen Preparation and Mounting of
are to be regarded separately as standard. The values stated in
Reflective Insulation, Radiant Barrier and Vinyl Stretch
each system may not be exact equivalents; therefore, each
Ceiling Materials for Building Applications to Assess
system shall be used independently of the other. Combining
Surface Burning Characteristics
values from the two systems may result in non-conformance
2.2 Other Standards:
with the standard.
TAPPI Test Method T 512 sp-02: Creasing of Flexible
1.3 The following safety hazards caveat pertains only to the
3
Packaging Material Paper Specimens for Testing
test methods (Section 10) described in this specification. This
standard does not purport to address all of the safety concerns,
3. Terminology
if any, associated with its use. It is the responsibility of the user
3.1 Definitions—For definitions of terms used in this speci-
of this standard to establish appropriate safety and health
fication, refer to Terminology C168.
practices and determine the applicability of regulatory limita-
3.2 Definitions of Terms Specific to This Standard:
tions prior to use.
3.2.1 radiant barrier—a low emittance (0.1 or less) surface
2. Referenced Documents used in the construction of a radiant barrier system.
2 3.2.2 radiant barrier system (RBS)—abuildingconstruction
2.1 ASTM Standards:
consisting of a radiant barrier bounded by an open air space.
C168 Terminology Relating to Thermal Insulation
3.2.3 non-structural radiant barrier—a radiant barrier ma-
C390 Practice for Sampling and Acceptance of Thermal
terial design that during manufacture is not bonded to a
Insulation Lots
structural building material.
C1158 Practice for Installation and Use of Radiant Barrier
3.2.4 structural radiant barrier—a radiant barrier material
Systems (RBS) in Building Construction
design that during manufacture is bonded (leaving no air space
C1338 Test Method for Determining Fungi Resistance of
between the radiant barrier and the bonding substrate) to a
Insulation Materials and Facings
structural building material such as plywood or oriented strand
C1371 Test Method for Determination of Emittance of
board (OSB).
Materials Near Room Temperature Using Portable Emis-
someters
4. Ordering Information
4.1 Prior to purchase, for sampling and acceptance proce-
1
This specification is under the jurisdiction of ASTM Committee C16 on
dures, Practice C390 is an option when to by purchaser and
Thermal Insulation and is under the direct responsibility of Subcommittee C16.21
manufacturer.
on Reflective Insulation.
Current edition approved Oct. 1, 2011. Published November 2011. Originally 4.2 Specify the width and total area to be installed.
approved in 1995. Last previous edition approved in 2010 as C1313/C1313M–10.
4.3 Specify any special markings.
DOI: 10.1520/C1313_C1313-11.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from TechnicalAssociation of the Pulp and Paper Industry (TAPPI),
the ASTM website. 15 Technology Parkway South, Norcross, GA 30092, http://www.tappi.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C1313/C1313M – 11
5. Materials and Manufacture 7.2.6.2 Pliability—Specimens tested in accordance with the
test procedure in 10.2
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C1313/C1313M–10 Designation: C1313/C1313M – 11
Standard Specification for
Sheet Radiant Barriers for Building Construction
1
Applications
This standard is issued under the fixed designation C1313/C1313M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers the general physical property requirements of radiant barrier materials for use in building
construction. The scope is specifically limited to requirements for radiant barrier sheet materials that consist of at least one surface
having a far-infrared emittance of 0.1 or less, such as metallic foils or metallic deposits mounted or unmounted on substrates.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformance with the standard.
1.3 The following safety hazards caveat pertains only to the test methods (Section 10) described in this specification. This
standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user
of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior
to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C168 Terminology Relating to Thermal Insulation
C390 Practice for Sampling and Acceptance of Thermal Insulation Lots
C1158 Practice for Installation and Use of Radiant Barrier Systems (RBS) in Building Construction
C1338 Test Method for Determining Fungi Resistance of Insulation Materials and Facings
C1371 Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers
D2261 Test Method for Tearing Strength of Fabrics by the Tongue (Single Rip) Procedure (Constant-Rate-of-Extension Tensile
Testing Machine)
D3310 Test Method for Determining Corrosivity of Adhesive Materials
E84 Test Method for Surface Burning Characteristics of Building Materials
E96/E96M Test Methods for Water Vapor Transmission of Materials Test Methods for Water Vapor Transmission of Materials
E2599 Practice for Specimen Preparation and Mounting of Reflective Insulation, Radiant Barrier and Vinyl Stretch Ceiling
Materials for Building Applications to Assess Surface Burning Characteristics
2.2 Other Standards:
3
TAPPI Test Method T 512 sp-02: Creasing of Flexible Packaging Material Paper Specimens for Testing
3. Terminology
3.1 Definitions—For definitions of terms used in this specification, refer to Terminology C168.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 radiant barrier—a low emittance (0.1 or less) surface used in the construction of a radiant barrier system.
3.2.2 radiant barrier system (RBS)—a building construction consisting of a radiant barrier bounded by an open air space.
3.2.3 non-structural radiant barrier—a radiant barrier material design that during manufacture is not bonded to a structural
building material.
3.2.4 structural radiant barrier—a radiant barrier material design that during manufacture is bonded (leaving no air space
1
This specification is under the jurisdiction ofASTM Committee C16 on Thermal Insulation and is under the direct responsibility of Subcommittee C16.21 on Reflective
Insulation.
Current edition approved MarchOct. 1, 2010.2011. Published March 2010.November 2011. Originally approved in 1995. Last previous edition approved in 20052010 as
C1313–05.C1313/C1313M–10. DOI: 10.1520/C1313_C1313-101.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from Technical Association of the Pulp and Paper Industry (TAPPI), 15 Technology Parkway South, Norcross, GA 30092, http://www.tappi.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C1313/C1313M – 11
between the radiant barrier and the bonding substrate) to a structural building material such as plywood o
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.