ASTM F891-04
(Specification)Standard Specification for Coextruded Poly(Vinyl Chloride) (PVC) Plastic Pipe With a Cellular Core
Standard Specification for Coextruded Poly(Vinyl Chloride) (PVC) Plastic Pipe With a Cellular Core
SCOPE
1.1 This specification covers coextruded poly(vinyl chloride) (PVC) plastic pipe with a cellular core and concentric inner and outer solid layers, and is produced using a multilayer coextrusion die for nonpressure use in three series: an IPS Schedule 40 series; a PS series with an iron pipe size outside diameter with varying wall thickness as required for pipe stiffness of 25, 50, and 100; and a sewer and drain series.
1.2 The function of this specification is to provide standardization of product-technical data and serve as a purchasing guide.
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. The notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.Note 1—All the pipe series covered by this specification are permitted to be perforated or belled for joining by solvent cement or belled for joining by an elastomeric seal (gasket). Because this pipe is OD controlled, the inside diameter will vary, and therefore, the pipe ID is not suitable for use as a socket.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.5 The values stated in inch-pound units are to be regarded as the standard.
Note 2—Specifications related to this specification are as follows: D 2665, D 2729, D 3034, F 512, F 758, and F 789.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: F 891 – 04
Standard Specification for
Coextruded Poly(Vinyl Chloride) (PVC) Plastic Pipe With a
1
Cellular Core
This standard is issued under the fixed designation F 891; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
1.1 This specification covers coextruded poly(vinyl chlo- 2.1 ASTM Standards:
ride) (PVC) plastic pipe with a cellular core and concentric D618 Practice for Conditioning Plastics for Testing
innerandoutersolidlayers,andisproducedusingamultilayer D1600 Terminology for Abbreviated Terms Relating to
coextrusion die for nonpressure use in three series: an IPS Plastics
3
Schedule 40 series; a PS series with an iron pipe size outside D1898 Practice for Sampling of Plastics
diameter with varying wall thickness as required for pipe D2122 Test Method for Determining Dimensions of Ther-
stiffness of 25, 50, and 100; and a sewer and drain series. moplastic Pipe and Fittings
1.2 Thefunctionofthisspecificationistoprovidestandard- D2152 Test Method for Adequacy of Fusion of Extruded
ization of product-technical data and serve as a purchasing Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
guide. Acetone Immersion
1.3 Thetextofthisspecificationreferencesnotes,footnotes, D2321 Practice for Underground Installation of Flexible
and appendixes which provide explanatory material.The notes Thermoplastic Pipe for Sewers and Other Gravity-Flow
and footnotes (excluding those in tables and figures) shall not Applications
be considered as requirements of the specification. D2412 TestMethodforDeterminationofExternalLoading
Characteristics of Plastic Pipe by Parallel-Plate Loading
NOTE 1—All the pipe series covered by this specification are permitted
D2444 Test Method for Impact Resistance of Thermoplas-
to be perforated or belled for joining by solvent cement or belled for
tic Pipe and Fittings by Means of a Tup (Falling Weight)
joining by an elastomeric seal (gasket). Because this pipe is OD
controlled, the inside diameter will vary, and therefore, the pipe ID is not D2564 Specification for Solvent Cements for Poly(Vinyl
suitable for use as a socket.
Chloride) (PVC) Plastic Piping Systems
NOTE 2—This standard specifies dimensional, performance and test
D2665 Specification for Poly(Vinyl Chloride) (PVC) Plas-
requirements for plumbing and fluid handling applications, but does not
tic Drain, Waste, and Vent Pipe and Fittings
address venting of combustion gases.
D2672 Specification for Joints for IPS PVC Pipe Using
1.4 This standard does not purport to address all of the
Solvent Cement
safety concerns, if any, associated with its use. It is the
D 2729 Specification for Poly(Vinyl Chloride) (PVC)
responsibility of the user of this standard to establish appro-
Sewer Pipe and Fittings
priate safety and health practices and determine the applica-
D2855 Practice for Making Solvent-Cemented Joints With
bility of regulatory limitations prior to use.
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
1.5 The values stated in inch-pound units are to be regarded
D3034 Specification for Type PSM Poly(Vinyl Chloride)
as the standard.
(PVC) Sewer Pipe and Fittings
D3212 Specification for Joints for Drain and Sewer Plastic
NOTE 3—Specifications related to this specification are as follows:
Pipes Using Flexible Elastomeric Seals
D2665, D2729, D3034, F512, F758, and F789.
1 2
This specification is under the jurisdiction ofASTM Committee F17 on Plastic For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Piping Systems and is the direct responsibility of Subcommittee F17.25 on Vinyl contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Based Pipe. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Sept. 1, 2004. Published September 2004. Originally the ASTM website.
e1 3
approved in 1985. Last previous edition approved in 2000 as F891–00 . Withdrawn.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
F 891–04
D3311 Specification for Drain, Waste, and Vent (DWV) 3.2.2 IPS Schedule 40 Series—pipe produced to an iron
Plastic Fittings Patterns pipe outside diameter with a Schedule 40 wall thickness.
D4396 SpecificationforRigidPoly(VinylChloride)(PVC) 3.2.3 PS Series— pipe produced to an IPS outside diameter
and Chlorinated Poly(Vinyl Chloride) (CPVC) Com- and having the required wall thickness to meet a designated
pounds for Plastic Pipe and Fittings Used in Nonp
...