33.140 - Special measuring equipment for use in telecommunications
ICS 33.140 Details
Special measuring equipment for use in telecommunications
Besondere Me?instrumente fur Telekommunikation
Materiel de mesure specifique aux telecommunications
Posebna merilna oprema za uporabo v telekomunikacijah
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 33.140 - Special measuring equipment for use in telecommunications
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
IEC 61744:2023 provides standard procedures for the calibration of optical fibre chromatic dispersion (CD) test sets. This document is applicable to all types of CD test sets, with the exception that measurements on multimode optical fibres are excluded. The purpose of this document is to define a standard procedure for calibrating optical fibre chromatic dispersion (CD) test sets. The detailed calibration steps used vary according to the measurement technique used in the CD test set. Whilst it is acknowledged that chromatic dispersion also occurs in multimode fibre and this fibre can be measured on many CD test sets, this document will restrict discussion to single mode fibre measurements applications only. The purpose of the procedures outlined in this document is to focus manufacturers and users of CD test sets toward the reduction of measurement uncertainty in chromatic dispersion determination in optical fibres under all applicable conditions. The procedures apply to calibration laboratories and to the manufacturers or users of CD test sets for the purpose of
a) calibrating CD test sets, and
b) evaluating the level of performance of the instrument.
Use of the procedures also allows correct evaluation of CD test set uncertainty, relative and traceable to appropriate (for example, national) standards. This third edition cancels and replaces the second edition published in 2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) updated terms and definitions;
b) the use of a reference fibre standard for calibration is now allowed and at the same level as the other calibration method;
c) Annex B was split into a new Annex B (on calibration uncertainty, still normative) and a new Annex C (on uncertainty at operating conditions, informative);
d) removed former C.3.4 on interferometric method since this method is no longer supported in IEC 60793-1-42;
e) removed Annex D and other references in text to calibration compensation to align with other calibration documents;
f) removed Annex E and other references in text to use of air wavelength since it is not used in the fibre domain.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61315:2019 is available as IEC 61315:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61315:2019 is applicable to instruments measuring radiant power emitted from sources that are typical for the fibre-optic communications industry. These sources include laser diodes, light emitting diodes (LEDs) and fibre-type sources. Both divergent and collimated radiations are covered. This document defines the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers. This third edition cancels and replaces the second edition published in 2005. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of terms and definitions; b) update of 5.1, including Table 1 (new type of source); c) update of Annex A; d) addition of Annex B on dB conversion. Keywords: Fibre-optic power meters
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to instruments measuring radiant power emitted from sources that
are typical for the fibre-optic communications industry. These sources include laser diodes,
light emitting diodes (LEDs) and fibre-type sources. Both divergent and collimated radiations
are covered. This document defines the calibration of power meters to be performed by
calibration laboratories or by power meter manufacturers.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62129-1:2016 specifies procedures for calibrating an optical spectrum analyzer that is developed for use in fibre-optic communications and designed to measure the power distribution of an optical spectrum. It does not apply to an optical wavelength meter that measures only centre wavelengths, a Fabry-Perot interferometer or a monochromator that has no display unit. This first edition of IEC 62129-1 cancels and replaces the first edition of IEC 62129, published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - update of term and definitions; - update of calibration conditions; - calculation change of uncertainties related to wavelength temperature dependence, power linearity, power level temperature dependence; - move of Annex E to the bibliography. Keywords: calibrating an optical spectrum analyser
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61315:2019 is available as IEC 61315:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61315:2019 is applicable to instruments measuring radiant power emitted from sources that are typical for the fibre-optic communications industry. These sources include laser diodes, light emitting diodes (LEDs) and fibre-type sources. Both divergent and collimated radiations are covered. This document defines the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers. This third edition cancels and replaces the second edition published in 2005. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) update of terms and definitions;
b) update of 5.1, including Table 1 (new type of source);
c) update of Annex A;
d) addition of Annex B on dB conversion.
Keywords: Fibre-optic power meters
- Standard133 pagesEnglish languagesale 15% off
- Standard87 pagesEnglish and French languagesale 15% off
IEC 62129-1:2016 specifies procedures for calibrating an optical spectrum analyzer that is developed for use in fibre-optic communications and designed to measure the power distribution of an optical spectrum. It does not apply to an optical wavelength meter that measures only centre wavelengths, a Fabry-Perot interferometer or a monochromator that has no display unit. This first edition of IEC 62129-1 cancels and replaces the first edition of IEC 62129, published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- update of term and definitions;
- update of calibration conditions;
- calculation change of uncertainties related to wavelength temperature dependence, power linearity, power level temperature dependence;
- move of Annex E to the bibliography.
Keywords: calibrating an optical spectrum analyser
- Standard110 pagesEnglish and French languagesale 15% off
This standard provides standard procedures for the calibration of optical fibre chromatic dispersion (CD) test sets. It also provides procedures to perform calibration checking on CD test sets whereby an extension to the test set calibration period may be obtained. This standard is applicable to all types of CD test set, with the exception that measurements on multimode optical fibers are excluded.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
This international standard is applicable to instruments measuring radiant power emitted from sources which are typical for the fibre-optic communications industry. The standard describes the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers.
- Standard85 pagesEnglish and French languagesale 15% off
This international standard is applicable to instruments measuring radiant power emitted from sources which are typical for the fibre-optic communications industry. The standard describes the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
This international standard is applicable to instruments measuring radiant power emitted from sources which are typical for the fibre-optic communications industry. The standard describes the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
Fibre optic power meters are designed to measure optical power from fibre optic sources as accurately as possible. This capability depends largely on the quality of the calibration process. This International Standard standardizes all of the steps involved in the calibration process: establishing the reference conditions, carrying out the calibration, calculating the uncertainty, and reporting the uncertainty, the reference conditions, and the traceability. It also creates a standardized type of power meter specification, which will make it easier to compare power meters from different vendors.
- Standard64 pagesEnglish languagesale 10% offe-Library read for1 day
Defines standard procedures for calibrating optical fibre chromatic dispersion test sets. The procedures apply to calibration laboratories, and to manufacturers and users of CD test sets, for: (a) calibrating CD test sets, (b) setting specifications of CD test sets, (c) extending the calibration period of an already calibrated CD test set. It applies to all CD test sets, except for multimode fibres.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
Fibre optic power meters are designed to measure optical power from fibre optic sources as accurately as possible. This capability depends largely on the quality of the calibration process. This International Standard standardizes all of the steps involved in the calibration process: establishing the reference conditions, carrying out the calibration, calculating the uncertainty, and reporting the uncertainty, the reference conditions, and the traceability. It also creates a standardized type of power meter specification, which will make it easier to compare power meters from different vendors.