17.200.20 - Temperature-measuring instruments
Temperature-measuring instruments
Temperaturme?gerate
Instruments de mesure de température
Instrumenti za merjenje temperature
General Information
IEC 62828-4:2020 establishes specific procedures for testing level transmitters used in measuring and control systems for industrial process and machinery control systems. For general test procedures, reference is to be made to IEC 62828-1:2017, applicable to all types of transmitters.
Throughout this document, the term "industrial transmitters" covers all types of transmitters used in measuring and control systems for industrial processes and for machinery.
The requirements of this document a...view more
- Standard116 pagesEnglish and French language
sale 15% off
IEC 62828-5:2020 establishes specific procedures for testing flow transmitters used in measuring and control systems for industrial process and for machinery control systems. For general test procedures, reference is to be made to IEC 62828-1:2017, applicable to all types of industrial and process measurement transmitters.
This document – together with IEC 62828-1:2017 – is the reference standard for testing every type of flow transmitter, not only for liquids but also for gases and for steam.
...view more
- Standard70 pagesEnglish and French language
sale 15% off
DOW = DAV + 36 months
- Amendment8 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment6 pagesEnglish language
sale 10% off- e-Library read for1 day
The object of this document is to determine the composition, nature of materials, manufacturing tests and thermoelectronic behaviour of connectors for sensors using thermocouples according to EN 60584-3:2008.This document does not cover such special thermocouples as U, L and W types; nevertheless, the user of such special thermocouples can use the connectors described hereafter with some restrictions mentioned in the relevant paragraphs.
- Standard13 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft12 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61788-4 specifies a test method for the determination of the residual resistanceratio (RRR) of Nb-Ti and Nb3Sn composite superconductors with Cu, Cu-Ni, Cu/Cu-Ni and Almatrix in a strain-free condition and zero external magnetic field. This method is intended foruse with superconductor specimens that have a monolithic structure with rectangular or roundcross-section, RRR value less than 350, and cross-sectional area less than 3 mm2. In the caseof Nb3Sn, the specimens have received a reaction...view more
- Standard37 pagesEnglish language
sale 10% off- e-Library read for1 day
This document provides general methods for measurement and calculation of quantities associated with human exposure to electromagnetic fields in the frequency range from 0 Hz to 300 GHz. It is intended specifically to be used for the assessment of emissions from products and comparison of these with the exposure limits for the general public given in Council Recommendation 1999/519/EC, and those given for workers in Directive 2013/35/EU, as appropriate. It also is intended to be used for assessm...view more
- Draft26 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61869-14:2018 provides all requirements specific to current transformers to be used in DC applications (DCCTs), whatever the technology used. The output signal can be analogue or digital. It is applicable to newly manufactured current transformers used for measuring, protection and/or control applications in DC power systems with a rated voltage above 1,5 kV. The general configuration of a single-pole low-power instrument transformer is described in Figure 601 of IEC 61869-6:2016. The DCCTs ...view more
- Standard45 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard45 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of IEC 62828 establishes specific procedures for testing temperature transmitters
used in measuring and control systems for industrial process and for machinery control
systems.
When the process measurement transmitter features the temperature transmitter separated
from the sensing element (RTD, TC, etc.), the standard applies only to the temperature
transmitter without the sensing element. In case of device where the sensing element is fully
integrated with the temperature trans...view more
- Standard17 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard17 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the technical and functional characteristics of temperature recorders for the transport, storage and distribution of temperature sensitive goods between -80 °C and +85 °C.
It specifies the test methods which allow the determination of the equipment's conformity, suitability and performance requirements.
It applies to the whole temperature recording system. The temperature sensor(s) may be integrated into the recorder or be remote from it [external sensor(s)].
...view more
- Standard96 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the technical and functional characteristics of temperature recorders for the transport, storage and distribution of temperature sensitive goods between -80 °C and +85 °C.
It specifies the test methods which allow the determination of the equipment's conformity, suitability and performance requirements.
It applies to the whole temperature recording system. The temperature sensor(s) may be integrated into the recorder or be remote from it [external sensor(s)].
...view more
- Standard96 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 62828-3:2018 establishes specific procedures for testing temperature transmitters used in measuring and control systems for industrial process and for machinery control systems. When the process measurement transmitter features the temperature transmitter separated from the sensing element, the standard applies only to the temperature transmitter without the sensing element. In the case of a device where the sensing element is fully integrated with the temperature transmitter, the standard a...view more
- Standard17 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard17 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 62828-3:2018 establishes specific procedures for testing temperature transmitters used in measuring and control systems for industrial process and for machinery control systems.
When the process measurement transmitter features the temperature transmitter separated from the sensing element, the standard applies only to the temperature transmitter without the sensing element. In the case of a device where the sensing element is fully integrated with the temperature transmitter, the standard ...view more
- Standard28 pagesEnglish and French language
sale 15% off
This part of IEC 61757 defines detail specifications for distributed temperature measurement
by a fibre optic sensor, also known as fibre optic distributed temperature sensing (DTS). DTS
includes the use of Raman scattering, Brillouin scattering and Rayleigh scattering effects. In
addition, Raman scattering and Rayleigh scattering based measurements are performed with
a single-ended fibre configuration only. Brillouin scattering based measurements are
performed with a single-ended fibre or ...view more
- Standard34 pagesEnglish language
sale 10% off- e-Library read for1 day
SIST EN- ISO 80601-2-56 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of a CLINICAL THERMOMETER in combination with its ACCESSORIES, hereafter referred to as ME EQUIPMENT. This document specifies the general and technical requirements for electrical CLINICAL THERMOMETERS. This document applies to all electrical CLINICAL THERMOMETERS that are used for measuring the BODY TEMPERATURE of PATIENTS. CLINICAL THERMOMETERS can be equipped with interfaces to accommodate secondary indicators, prin...view more
- Standard65 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO 80601-2-56:2017 applies to the basic safety and essential performance of a clinical thermometer in combination with its accessories, hereafter referred to as me equipment. This document specifies the general and technical requirements for electrical clinical thermometers. This document applies to all electrical clinical thermometers that are used for measuring the body temperature of patients.
Clinical thermometers can be equipped with interfaces to accommodate secondary indicators, printin...view more
- Standard65 pagesEnglish language
sale 10% off- e-Library read for1 day
This International Standard establishes the requirements for simplex, duplex and triplex
mineral-insulated metal-sheathed thermocouple cables and thermocouples, which are intended
for use in general industrial applications. The abbreviation MIMS (for “mineral-insulated
metal-sheathed”) will be used hereafter. It covers thermocouple cables and thermocouples with
only base-metal conductors of Types T, J, E, K and N. The specifications in this standard apply
to new thermocouple cables and ther...view more
- Standard29 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61515:2016 establishes the requirements for simplex, duplex and triplex mineral-insulated metal-sheathed thermocouple cables and thermocouples, which are intended for use in general industrial applications. The abbreviation MIMS (for "mineral-insulated metal-sheathed") will be used hereafter. It covers thermocouple cables and thermocouples with only base-metal conductors of Types T, J, E, K and N. The specifications in this standard apply to new thermocouple cables and thermocouple units as ...view more
- Standard29 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61515:2016 establishes the requirements for simplex, duplex and triplex mineral-insulated metal-sheathed thermocouple cables and thermocouples, which are intended for use in general industrial applications. The abbreviation MIMS (for "mineral-insulated metal-sheathed") will be used hereafter. It covers thermocouple cables and thermocouples with only base-metal conductors of Types T, J, E, K and N. The specifications in this standard apply to new thermocouple cables and thermocouple units as ...view more
- Standard54 pagesEnglish and French language
sale 15% off
IEC 61788-4:2016 specifies a test method for the determination of the residual resistance ratio (RRR) of Nb-Ti and Nb3Sn composite superconductors with Cu, Cu-Ni, Cu/Cu-Ni and Al matrix. This method is intended for use with superconductor specimens that have a monolithic structure with rectangular or round cross-section, RRR value less than 350, and cross-sectional area less than 3 mm2. In the case of Nb3Sn, the specimens have received a reaction heat-treatment. This fourth edition cancels and r...view more
- Standard35 pagesEnglish language
sale 10% off- e-Library read for1 day
- Corrigendum3 pagesEnglish language
sale 10% off- e-Library read for1 day