TRRTP132 - Pravilnik o ocenjevanju kakovosti zunanjega zraka
Pravilnik o ocenjevanju kakovosti zunanjega zraka
Pravilnik o ocenjevanju kakovosti zunanjega zraka
General Information
Frequently Asked Questions
An EU Regulation is a binding legislative act that must be applied in its entirety across the European Union. Unlike directives, regulations do not need to be transposed into national law and are directly applicable in all member states. Regulations are used when uniform application across all EU countries is essential.
Regulation TRRTP132 covers "Pravilnik o ocenjevanju kakovosti zunanjega zraka". There are 1 standards associated with this regulation.
Harmonized standards under TRRTP132 are European standards (ENs) developed by CEN, CENELEC, or ETSI in response to a mandate from the European Commission. When these standards are cited in the Official Journal of the European Union, products manufactured in conformity with them benefit from a presumption of conformity with the essential requirements of TRRTP132, facilitating CE marking and free movement within the European Economic Area.
This European Standard specifies a method for the determination of particulate lead (Pb), cadmium (Cd), arsenic (As) and nickel (Ni) in ambient air that can be used in the framework of the European Council Directive on Ambient Air Quality Assessment and Management [1] and the 1st [2] and 4th [3] Daughter Directives. Performance requirements with which the method has to comply are specified in this European Standard. The performance characteristics of the method were determined in comparative field validation tests carried out at four European locations (see [4]).
This European Standard specifies a method for sampling of Pb, Cd, As and Ni as part of the PM10 aerosol, microwave digestion of the samples and analysis by graphite furnace atomic absorption spectrometry or by inductively coupled plasma (quadrupole) mass spectrometry.
This European Standard is applicable for the measurement of Pb, Cd, As and Ni as part of the PM10 aerosol fraction in the concentration ranges listed in Table 1.
Table 1 - Working ranges of the method in ng/m³
From To
Pb 1 4 000
Cd 0,1 50
As 0,5 350
Ni 2 100
The actual lower limits of the working ranges depend upon the variability of the laboratory filter blank (5.3.1). The lower limits of the working ranges given in Table 1 are expected values based upon performance achieved in the field validation tests. Similarly the upper limits of the working ranges have been set arbitrarily based upon the maximum daily values measured during the field validation tests. The method can be applied to higher concentrations provided the PM10 collection characteristics of the sampler are not compromised.
- Standard54 pagesEnglish languagee-Library read for1 day