TP013 - Pravilnik o metodologiji izdelave in izdaji energetskih izkaznic stavb
Pravilnik o metodologiji izdelave in izdaji energetskih izkaznic stavb
Pravilnik o metodologiji izdelave in izdaji energetskih izkaznic stavb
Standard v predpisu SIST EN 15603 ----> razveljavljen ----> SIST EN ISO 52000-1 SIST EN ISO 13790----> razveljavljen ----> SIST EN ISO 52016-1
General Information
This standard provides a systematic, comprehensive and modular overall structure on the integrated energy performance of buildings, in order to ensure consistency among all CEN standards required to calculate the energy performance of buildings according to the EPBD (2010/31/EU).
This standard handles the framework of the overall energy performance of a building, covering inter alia:
a) common terms, definitions and symbols;
b) building and system boundaries;
c) building partitioning;
d) methodology for calculating the energy performance of a building (set of overall formulae on energy used, delivered, produced and/or exported at the building site and near-by);
e) set of overall formulae and input-output relations, linking the various elements relevant for the assessment of the overall energy performance of buildings which are treated in separate standards;
f) general requirements to standards dealing with partial calculations;
g) general rules in setting out alternative calculation routes according to the calculation scope and requirements;
h) rules for the combination of different partitioning;
i) performance indicators;
j) methodology for measured energy performance assessment.
- Standard141 pagesEnglish languagesale 10% offe-Library read for1 day
The work concerns revision of existing standard EN ISO 13790. The scope will change. This revised international standard will provide calculation methods for assessment of the sensible and latent energy needs for space heating and cooling of a residential or a non-residential building, or a part of it, referred to as "the building". This method calculates, for a thermal zone in a building, the sensible and latent thermal energy needs based on the balance between the heat and moisture transfer by transmission and ventilation and the internal and solar heat gains. The energy needs are calculated by an hourly or monthly method. The hourly calculation method will be described in EN ISO 52017-1 (upgraded version of simple hourly method). The monthly method will be given in this standard including procedures how to derive monthly correlation coefficients from hourly calculations. The following input values and boundary conditions are obtained from other standards in the EPB series: overall routing of the energy performance calculation; occupancy patterns and conditions of use; thermal zoning of the building; environment conditions, thermal, dynamic (mass) and solar characteristics of building elements and their junctions; air infiltration and ventilation and ventilation system characteristics. Moisture absorption and desorption in building elements will not be considered. Because some of the characteristics that are input for the calculation are also dependent on the thermal balance calculation, many interactions will have to be accounted for at the level of each time step. The standard will contain simplified approaches for the energy balance in adjacent spaces that are not heated or cooled, including sunspaces
- Standard216 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation227 pagesSlovenian languagesale 10% offe-Library read for1 day
This document provides the method of calculation of the thermal resistance and thermal transmittance
of building components and building elements, excluding doors, windows and other glazed units,
curtain walling, components which involve heat transfer to the ground, and components through which
air is designed to permeate.
The calculation method is based on the appropriate design thermal conductivities or design thermal
resistances of the materials and products for the application concerned.
The method applies to components and elements consisting of thermally homogeneous layers (which
can include air layers).
This document also provides an approximate method that can be used for elements containing
inhomogeneous layers, including the effect of metal fasteners, by means of a correction term given in
Annex F. Other cases where insulation is bridged by metal are outside the scope of this document.
NOTE Table 1 in the Introduction shows the relative position of this document within the set of EPB
standards in the context of the modular structure as set out in ISO 52000-1.
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation50 pagesSlovenian languagesale 10% offe-Library read for1 day
- Standard – translation49 pagesSlovenian languagesale 10% offe-Library read for1 day
This document specifies a method and provides conventions for the calculation of the steady‐state
transmission and ventilation heat transfer coefficients of whole buildings and parts of buildings. It is
applicable both to heat loss (internal temperature higher than external temperature) and to heat gain
(internal temperature lower than external temperature). For the purpose of this document, the heated
or cooled space is assumed to be at uniform temperature.
Annex C provides a steady‐state method to calculate the temperature in unconditioned spaces adjacent
to conditioned spaces.
NOTE Table 1 in the Introduction shows the relative position of this document within the set of EPB standards
in the context of the modular structure as set out in ISO 52000-1.
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day