VMO - Safety of measuring, control, and laboratory equipment
Standardization in the field of safety of measuring, control and laboratory equipment.
Varnost merilne, krmilne in laboratorijske opreme - odbor pridružen SIST/TC MOV
Standardizacija na področju varnosti merilne, krmilne in laboratorijske opreme.
General Information
Frequently Asked Questions
VMO is a Technical Committee within the Slovenian Institute for Standardization (SIST). It is named "Safety of measuring, control, and laboratory equipment" and is responsible for: Standardization in the field of safety of measuring, control and laboratory equipment. This committee has published 13 standards.
VMO develops SIST standards in the area of Electrotehcnics and Electronics. The scope of work includes: Standardization in the field of safety of measuring, control and laboratory equipment. Currently, there are 13 published standards from this technical committee.
The Slovenian Institute for Standardization (SIST) is the national standards body of Slovenia. SIST adopts European and international standards as Slovenian national standards and develops original Slovenian standards where needed. As a member of ISO, IEC, CEN, and CENELEC, SIST represents Slovenian interests in international standardization.
A Technical Committee (TC) in SIST is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.
IEC 61010-2-030:2010 specifies safety requirements for testing and measuring circuits which are connected for test or measurement purposes to devices or circuits outside the measurement equipment itself. These include measurement circuits which are part of electrical test and measurement equipment, laboratory equipment, or process control equipment. The existence of these circuits in equipment requires additional protective means between the circuit and an OPERATOR. This Part 2-030 is to be used in conjunction with the latest edition of IEC 61010-1. It was established on the basis of the third edition (2010) of IEC 61010-1. Consideration may be given to future editions of, or amendments to, IEC 61010-1.
- Draft13 pagesEnglish languagee-Library read for1 day
66/369/CDV rejected at IEC level but no RVC established yet - Wait evolution at IEC for proceeding at CENELEC level
- Draft141 pagesEnglish languagee-Library read for1 day
Applies only to electrically powered laboratory equipment for the heating of materials but excludes equipment for the heating and ventilation of laboratories and sterilizing equipment. Has the status of a group safety publication in accordance with IEC Guide 104.
- Standard21 pagesEnglish languagee-Library read for1 day
Applies to electrically powered laboratory atomic spectrometers with thermal atomization, including atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers, microwave coupled plasma spectrometers, and mass spectrometers, all with thermal atomization and ionization (including tubing and connectors which are provided by the manufacturer for connection to external supplies). This publication has the status of a group safety publication in accordance with IEC Guide 104.
- Standard17 pagesEnglish languagee-Library read for1 day
EN following parallel vote * Superseded by EN 61010-2-010:2003
- Amendment13 pagesEnglish languagee-Library read for1 day
Applies to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. The requirements for equipment which contain heating devices are given in EN 61010-2-010. This publication has the status of a group safety publication in accordance with IEC Guide 104.
- Standard12 pagesEnglish languagee-Library read for1 day
EN following parallel vote
- Amendment6 pagesEnglish languagee-Library read for1 day
Applies to electrically powered laboratory centrifuges but excludes other rotating electrical machinery and the use in explosive atmospheres. Has the status of a group safety publication in accordance with IEC Guide 104.
- Standard32 pagesEnglish languagee-Library read for1 day
EN following parallel vote * Amendment superseding HD 215 S1 * Superseded by EN 61010-1:2001
- Amendment3 pagesEnglish languagee-Library read for1 day
Applies to the specification of performance, with primary reference to industrial applications, of the following kinds of electrical and electronic equipment:[
]- indicating and recording instruments which measure electrical quantities;[
]- material measures which supply electrical quantities;[
]- instruments which measure non-electrical quantities using electrical means, for all parts of the measuring chain which present electrical output signals.[
]It is based on the methods expounded in GUM for expressing and evaluating the uncertainty of measurement, and refers to GUM for the statistical procedures to be used in determining the intervals assigned to represent uncertainty (including the way to account for non-negligible uncertainties in the traceability chain).[
]The object is to provide methods for ensuring uniformity in the specification and determination of uncertainties of equipment within its scope. All other necessary requirements have been reserved for dependent IEC product standards pertaining to particular types of equipment which fall within the scope of this standard.
- Standard26 pagesEnglish languagee-Library read for1 day
- Standard34 pagesEnglish languagee-Library read for1 day
Applies to hand-held and hand-manipulated CURRENT CLAMPS. These CURRENT CLAMPS are for use in the measurement of current without interruption of the current path of the circuit in which it is measured. They may be stand-alone CURRENT CLAMPS which are themselves within the scope of part 1, or accessories to other equipment within the scope of part 1. This standard does not apply to current transformers or current transducers intended for fixed installations.
- Standard16 pagesEnglish languagee-Library read for1 day
Applies to the following hand-held and hand-manipulated probe assemblies: -low-voltage and high-voltage, non-attenuating probe assemblies (type A) -high-voltage attenuating or divider probe assemblies (type B) -low-voltage attenuating or divider probe assemblies (type C). Has the status of a group safety publication in accordance with IEC Guide 104.
- Standard25 pagesEnglish languagee-Library read for1 day
Specifies general safety requirements for electrical equipment intended for professional, industrial process, and educational use, including equipment and computing devices for: -measurement and test; -control; -laboratory use; -accessories intended for use with this equipment. Does not cover: -reliable function, performance or other properties of the equipment; -servicing (repair); -protection of servicing (repair) personnel. Has the status of a group safety publication in accordance with IEC Guide 104.
- Standard134 pagesEnglish languagee-Library read for1 day