ISO/TC 161/WG 3 - Controls
This document specifies safety, design, construction and performance requirements and testing for electronic fuel/air ratio control (FARC) systems. Systems can include sensors, mechanical actuators and motors/blowers that make up the complete system. Systems can be described as: closed loop fuel/air ratio control systems (ERC), see 3.1.1; closed loop fuel/air ratio trim systems (ERT), see 3.1.2; fuel/air ratio supervision systems (ERS), see 3.2. NOTE 1 Throughout this document, the word “system” means “FARC control and system components”. These systems are intended for use with burners and appliances that burn gaseous or liquid fuels. This document describes the procedures for evaluating these requirements and specifies information necessary for installation and use. This document applies to the inherent safety of the system, to the declared operating values, operating times and operating sequences if they are associated with FARC safety and to the testing of FARC systems used in, on or in association with appliances. NOTE 2 The documents for burners, appliances or processes which use ERC, ERS or ERT can override the requirements of this document. This document prescribes testing requirements in addition to the relevant standards for integrated devices or components (e.g. actuators) to ensure safe operation of the FARC system. If no part 2 standards in ISO/TC 161, Controls and protective devices for gaseous and liquid fuels, or IEC/TC 72, Textile machinery and accessories, exist, then IEC 60730-1 is considered. NOTE 3 Supplemental or modified requirements and tests and evaluations can be needed for ERC, ERS or ERT systems for conformance with relevant burner, appliance or process standards. Conformance of an ERC, ERS or ERT with this document does not imply that such systems or components thereof are acceptable for use on an appliance without supplemental tests of the control system applied to the particular appliance to meet the requirements of the relevant burner, appliance or process standard(s). This document applies to electronic fuel/air ratio control systems that can be tested independently or as a system or as part of an appliance or as part of a burner. This document does not cover burner control function like e.g. burner ignition, flame supervision and fuel shutoff.
- Standard40 pagesEnglish languagesale 15% off
This document specifies safety, constructional, performance and testing requirements of normally open automatic vent valves, hereafter referred to as “valves”. This document applies to valves with a declared maximum operating pressure up to and including 500 kPa of nominal connection sizes up to and including DN 100 (4”), for use in gas control train of gas burners or in appliances using gaseous fuels such as natural, manufactured or liquefied petroleum gas (LPG). It is not applicable to corrosive and waste gases. This document applies to: — electrically operated valves and to valves actuated by fluids where the control valves for these fluids are actuated electrically, but not to any external devices for switching the control signal or actuating energy; — valves fitted with open position indicator switches. This document covers type testing only.
- Standard26 pagesEnglish languagesale 15% off
This document specifies safety, constructional and performance requirements and testing of automatic, semi-automatic shut-off valves, and general purpose valves for gas burners, gas appliances and appliances of similar use excluding use in fuel gas infrastructures (transportation and distribution systems). This document applies to controls for use at maximum operating pressures above 500 kPa up to and including 6 300 kPa with sizes up to DN 250 for use on burners or in appliances using fuel gases, such as natural gas, manufactured gas or liquefied petroleum gas (LPG). This document applies to: — valves being mounted in gas installations; — valves directly or indirectly actuated, electrically or by mechanical means; — valves actuated by hydraulic or pneumatic means, including the pilot valves for these fluids if actuated electrically and including release valves, but not to any external electrical devices for switching the actuating energy; — valves where the flow rate is controlled by external electrical signals, either in discrete steps or proportional to the applied signal and valves fitted with closed position indicator switches; — valves to be used in appliances, but not in gas transfer systems outside appliances. This document covers type testing only. This document does not apply to valves covered under the scope of ISO 23551-1 or the ISO 23555 series.
- Standard39 pagesEnglish languagesale 15% off
This document specifies safety, constructional and performance requirements and testing of automatic, semi-automatic shut-off valves and general purpose valves for gas burners, gas appliances and appliances of similar use, hereinafter referred to as valves. This document applies to normally closed valves and general purpose valves mounted upstream to gas burners and gas appliances with declared maximum operating pressures up to and including 500 kPa, for use on burners or in appliances using fuel gases such as natural gas, manufactured gas or liquefied petroleum gas (LPG). It is not applicable to corrosive and waste gases. This document applies to: — valves directly or indirectly actuated, electrically or by mechanical means; — valves actuated by hydraulic or pneumatic means; — valves where the flow rate is controlled by external electrical signals, either in discrete steps or proportional to the applied signal; and — valves fitted with closed position indicator switches. This document covers type testing only.
- Standard35 pagesEnglish languagesale 15% off
ISO 23551-4:2018 specifies safety, constructional and performance requirements of valve-proving systems (VPS), intended for use with gas burners and gas-burning appliances. It also describes the test procedures for checking compliance with these requirements and provides information necessary for the purchaser and user. ISO 23551-4:2018 is applicable to all types of VPS which are used for the automatic detection of leakage in a gas burner section having at least two valves designed in accordance with ISO 23551‑1 and which give a signal if the leakage of one of the valves exceeds the detection limit. ISO 23551-4:2018 is applicable to VPS with a maximum working pressure up to and including 500 kPa for use in systems using fuel gases. ISO 23551-4:2018 is not applicable to VPSs for use in explosive atmospheres. NOTE Provisions for production control are not part of the ISO 23551 series.
- Standard31 pagesEnglish languagesale 15% off
ISO 23550:2018 specifies safety, construction, performance and testing requirements for controls for gas burners and gas burning appliances for use with natural gas, manufactured gas or liquefied petroleum gas (LPG). ISO 23550:2018 applies to controls for use at maximum operating pressures up to and including 500 kPa. This document provides the general requirements that are intended to be the basis for the specific control standards found in the ISO 23551 and ISO 23552 series. These include the following: - automatic and semi-automatic gas valves; - gas thermoelectric flame supervision controls; - gas and oil /air ratio controls; - gas pressure regulators; - manual gas valves; - mechanical gas thermostats; - multifunctional gas controls; - air and gas pressure-sensing devices; - gas vent valves; - gas valve-proving systems. ISO 23550:2018 covers type testing only. ISO 23550:2018 is also applicable to Gas Quick Connectors (GQC) for use inside appliances with connections up to, and including DN 25, and a maximum operating pressure up to and including 100 kPa. GQCs include: - tube to tube connections; - tube to control connections; and - tube to fitting connections. ISO 23550:2018 does not apply to mechanical controls for use with liquid fuels. It is also not applicable to corrosive and waste gases.
- Standard66 pagesEnglish languagesale 15% off
ISO 23551-10:2016 specifies the safety, design, construction and performance requirements and testing for automatic vent valves (hereafter referred to as "valves") for use with gas burners, gas appliances burning one or more gaseous fuels. It is applicable to valves with declared maximum inlet pressures up to and including 500 kPa (5 bar) of nominal connection sizes up to and including DN 100 (4"). It is applicable to - normally open valves, - electrically operated valves and to valves actuated by fluids where the control valves for these fluids are actuated electrically, but not to any external devices for switching the control signal or actuating energy, and - valves fitted with open position indicator switches. It is not applicable to - valves for burners and appliances using renewables and/or waste gases (i.e. gases having corrosive characteristics), In case valves are in contact with renewables and/or waste gases, it is recommend to use ISO 23551-10:2016 only if explicit information is provided and relevant test methods and requirements are specified. - valves for appliances intended to be installed in the open air and exposed to the outdoor environment, - valves that are connected directly to mains pipe-work or to a container that maintains a standard distribution pressure, and - valves suitable with oil. It is applicable to type testing only.
- Standard18 pagesEnglish languagesale 15% off
- Standard7 pagesEnglish languagesale 15% off
ISO 23551-1:2012 specifies safety, constructional and performance requirements and testing of automatic and semi-automatic shut-off valves for gas burners, gas appliances and appliances of similar use. It applies to normally closed valves, valves being mounted upstream to gas burners and gas appliances, valves with declared maximum working pressures up to and including 500 kPa, for use on burners or in appliances using fuel gases as natural gas, manufactured gas or liquefied petroleum gas (LPG), valves directly or indirectly actuated, electrically or by mechanical means, valves actuated by hydraulic or pneumatic means, valves where the flow rate is controlled by external electrical signals, either in discrete steps or proportional to the applied signal, and valves fitted with closed position indicator switches. ISO 23551-1:2012 covers type testing only.
- Standard37 pagesEnglish languagesale 15% off
Frequently Asked Questions
ISO/TC 161/WG 3 is a Working Group within the International Organization for Standardization (ISO). It is named "Controls". This committee has published 9 standards.
ISO/TC 161/WG 3 develops ISO standards in the area of Information technology. Currently, there are 9 published standards from this working group.
The International Organization for Standardization (ISO) is an independent, non-governmental international organization that develops and publishes international standards. Founded in 1947 and headquartered in Geneva, Switzerland, ISO brings together experts from 170+ member countries to share knowledge and develop voluntary, consensus-based standards that support innovation and provide solutions to global challenges.
A Working Group in ISO is a specialized group responsible for developing standards or technical work within a defined scope. These bodies bring together international experts to create consensus-based standards that support global trade, safety, and interoperability.