IEC/SC 31M - Non-electrical equipment and protective systems for explosive atmospheres
To prepare and maintain international standards relating to non-electrical equipment and protective systems for use where there is a hazard due to the possible presence of explosive atmospheres of gases, vapours, mists or combustible dusts. Note: For the purposes of this sub-committee non-electrical equipment is defined as "equipment which can achieve its intended function mechanically". For the purposes of this sub-committee, 'Protective system' is defined as devices other than components of the equipment which are intended to halt incipient explosions immediately and/or to limit the effective range of an explosion.
Appareils non électriques et systèmes de protection pour atmosphères explosives
Préparer et maintenir des normes internationales concernant les équipements non-électriques et les systèmes de protection utilisés en cas de danger dû à la présence éventuelle d'atmosphères explosives de gaz, vapeurs, brouillards ou poussières combustibles. Note : Pour les objectifs de ce sous-comité, les équipements non électriques sont définis comme des «équipements pouvant atteindre la fonction prévue mécaniquement». Pour les objectifs du sous-comité, on entend par «système de protection» les dispositifs autres que les composants de l'équipement qui sont destinés à arrêter immédiatement les explosions naissantes et/ou à limiter la portée effective d'une explosion.
General Information
ISO/IEC 80079-34:2018 specifies particular requirements and information for establishing and maintaining a quality management system to manufacture Ex Products in accordance with the certificates. While it does not preclude the use of other quality management systems that are compatible with the objectives of ISO 9001:2015 and which provide equivalent results, the minimum requirements are given in this document. This second edition cancels and replaces the first edition, published in 2011, and constitutes a full technical revision. The significant changes with respect to the previous edition should be considered as minor technical revisions. However, the clause numbering in regard to the previous edition has changed in order to be in line with ISO 9001:2015. The normal Table of Significant Changes has not been included for this reason. This publication is published as a double logo standard. This standard should be read in conjunction with ISO 9001:2015
- Standard100 pagesEnglish languagesale 15% off
- Standard126 pagesEnglish and French languagesale 15% off
ISO/IEC 80079-20-1:2017 is published as a dual log standard and provides guidance on classification of gases and vapours. It describes a test method intended for the measurement of the maximum experimental safe gaps (MESG) for gas-air mixtures or vapour-air mixtures under normal conditions of temperature and pressure (20 °C, 101,3 kPa) so as to permit the selection of an appropriate group of equipment. This document also describes a test method intended for use in the determination of the auto-ignition temperature (AIT) of a vapour-air mixture or gas-air mixture at atmospheric pressure, so as to permit the selection of an appropriate temperature class of equipment. Values of chemical properties of materials are provided to assist in the selection of equipment to be used in hazardous areas. Further data may be added as the results of validated tests become available. The materials and the characteristics included in a table (see Annex B) have been selected with particular reference to the use of equipment in hazardous areas. The data in this document have been taken from a number of references which are given in the bibliography. These methods for determining the MESG or the AIT may also be used for gas-air-inert mixtures or vapour-air-inert mixtures. However, data on air-inert mixtures are not tabulated. Keywords: classification of gases and vapours, measurement of the maximum experimental safe gaps (MESG)
- Standard100 pagesEnglish languagesale 15% off
- Standard167 pagesEnglish and French languagesale 15% off
ISO 80079-37:2016 specifies the requirements for the design and construction of non-electrical equipment, intended for use in explosive atmospheres, protected by the types of protection constructional safety "c", control of ignition source "b" and liquid immersion "k". This part of ISO/IEC 80079 supplements and modifies the requirements in ISO 80079-36. Where a requirement of this standard conflicts with the requirement of ISO 80079-36 the requirement of this standard takes precedence. Types of protection "c", "k" and "b" are not applicable for Group I, EPL Ma without additional protective precautions. The types of ignition protection described in the standard can be used either on their own or in combination with each other to meet the requirements for equipment of Group I, Group II, and Group III depending on the ignition hazard assessment in ISO 80079-36. Keywords: constructional safety "c", control of ignition source "b" and liquid immersion "k"
- Standard100 pagesEnglish languagesale 15% off
ISO 80079-36:2016 specifies the basic method and requirements for design, construction, testing and marking of non-electrical Ex equipment, Ex Components, protective systems, devices and assemblies of these products that have their own potential ignition sources and are intended for use in explosive atmospheres. Hand tools and manually operated equipment without energy storage are excluded from the scope of this standard. This standard does not address the safety of static autonomous process equipment when it is not part of equipment referred to in this standard. This standard does not specify requirements for safety, other than those directly related to the risk of ignition which may then lead to an explosion. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it may be assumed that equipment can be operated are: - temperature -20 °C to 60 °C; - pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and - air with normal oxygen content, typically 21 % v/v. Such atmospheres can also exist inside the equipment. In addition, the external atmosphere can be drawn inside the equipment by natural breathing produced as a result of fluctuations in the equipment's internal operating pressure, and/or temperature. This part of ISO/IEC 80079 specifies the requirements for the design and construction of equipment, intended for explosive atmospheres in conformity with all Equipment Protection Levels (EPLs) of Group I, II and III. This standard supplements and modifies the general requirements of IEC 60079-0, as shown in Table 1 in the Scope of the document. Keywords: mechanical explosion protected equipment