ISO/TC 146/SC 6/WG 20 - Determination of phthalates
Détermination des phthalates
General Information
Frequently Asked Questions
ISO/TC 146/SC 6/WG 20 is a Subcommittee within the International Organization for Standardization (ISO). It is named "Determination of phthalates". This committee has published 1 standards.
ISO/TC 146/SC 6/WG 20 develops ISO standards in the area of Information technology. Currently, there are 1 published standards from this subcommittee.
The International Organization for Standardization (ISO) is an independent, non-governmental international organization that develops and publishes international standards. Founded in 1947 and headquartered in Geneva, Switzerland, ISO brings together experts from 170+ member countries to share knowledge and develop voluntary, consensus-based standards that support innovation and provide solutions to global challenges.
A Subcommittee (SC) in ISO operates under a Technical Committee and focuses on a specific subset of the TC's scope. Subcommittees develop standards and technical specifications in their specialized area, reporting to their parent Technical Committee. They may also have working groups for detailed technical work.
ISO 16000-33:2017 specifies the sampling and analysis of phthalates in indoor air and describes the sampling and analysis of phthalates in house dust and in solvent wipe samples of surfaces by means of gas chromatography/mass spectrometry. Two alternative sampling and processing methods, whose comparability has been proven in a round robin test, are specified for indoor air[4]. Sampling can take place using sorbent tubes with subsequent thermal desorption and GC-MS analysis. Alternatively, sampling can take on other types of sorbent tubes that are subsequently analysed by solvent extraction with GC-MS. Depending on the sampling method, the compounds dimethyl phthalate to diisoundecylphthalate can be analysed in house dust as described in Annex C[8]. The investigation of house dust samples is only appropriate as a screening method. This investigation only results in indicative values and is not acceptable for a final assessment of a potential need for action. Dimethyl phthalate to diisoundecylphthalate can be analysed in solvent wipe samples as described in Annex B. Solvent wipe samples are suitable for non-quantitative source identification. NOTE In principle, the method is also suitable for the analysis of other phthalates, adipates and cyclohexane dicarboxylic acid esters, but this is confirmed by determination of the performance characteristics in each case. General information on phthalates are given in Annex A.
- Standard40 pagesEnglish languagesale 15% off
- Standard46 pagesEnglish languagee-Library read for1 day
- Standard41 pagesFrench languagesale 15% off





