ISO/TC 201/SC 6/WG 3 - Depth resolution for SIMS
Résolution en profondeur pour la spectrométrie de masse des ions secondaires
General Information
Frequently Asked Questions
ISO/TC 201/SC 6/WG 3 is a Subcommittee within the International Organization for Standardization (ISO). It is named "Depth resolution for SIMS". This committee has published 3 standards.
ISO/TC 201/SC 6/WG 3 develops ISO standards in the area of Information technology. Currently, there are 3 published standards from this subcommittee.
The International Organization for Standardization (ISO) is an independent, non-governmental international organization that develops and publishes international standards. Founded in 1947 and headquartered in Geneva, Switzerland, ISO brings together experts from 170+ member countries to share knowledge and develop voluntary, consensus-based standards that support innovation and provide solutions to global challenges.
A Subcommittee (SC) in ISO operates under a Technical Committee and focuses on a specific subset of the TC's scope. Subcommittees develop standards and technical specifications in their specialized area, reporting to their parent Technical Committee. They may also have working groups for detailed technical work.
This document specifies a method for measuring the mass resolution in SIMS, and how to compare the mass resolution between different instruments (e.g. TOF-SIMS, Magnetic SIMS, Quadrupole SIMS, Fourier Transform SIMS, etc.) by considering the peak shapes.
- Technical specification15 pagesEnglish languagesale 15% off
This document specifies a method of determining relative sensitivity factors (RSFs) for secondary-ion mass spectrometry (SIMS) from ion-implanted reference materials. The method is applicable to specimens in which the matrix is of uniform chemical composition, and in which the peak concentration of the implanted species does not exceed one atomic percent.
- Standard4 pagesEnglish languagesale 15% off
ISO 20411:2018 specifies a method for determining the maximum count rate for an acceptable limit of divergence from linearity of the intensity scale in pulse counting magnetic sector-type secondary ion mass spectrometers or quadrupole secondary ion mass spectrometers. It uses a test based on depth profile analysis of two isotopes in a reference material which has a gradual concentration change between low and high concentration regimes. It also includes a correction method for saturated intensity caused by the dead time of the detector. The correction can increase the intensity range for 95 % linearity so that a higher maximum count rate can be employed for those spectrometers for which the relevant correction equations have been shown to be valid. ISO 20411:2018 does not apply to time of flight mass spectrometers. ISO 20411:2018 is only applicable to elements with minor isotopes. It is not applicable if the element is monoisotopic or contains isotopes with equal abundances.
- Standard15 pagesEnglish languagesale 15% off