WG 3 - TC 72/WG 3
TC 72/WG 3
General Information
IEC 60730-2-10:2026 applies to automatic electrical motor-starting relays
- intended to control the start windings of single phase motors;
- for use in, on, or in association with equipment for household appliance and similar use;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "control" means "motor-starting relays".
- intended for appliances within the scope of IEC 60335;
- for equipment that is used in building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS);
- for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 1 Controls for commercial catering, heating and air-conditioning equipment.
- used in, on, or in association with equipment that are smart enabled;
EXAMPLE 2 Smart grid control, remote interfaces/control of energy-consuming equipment.
- that are AC or DC powered with a rated voltage not exceeding 690 V AC or 600 V DC;
- used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
- utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
- using NTC or PTC thermistors, requirements for which are contained in Annex J;
- that are mechanically or electrically operated, responsive to or controlling such characteristics as current and voltage, or combinations thereof;
EXAMPLE 3 Centrifugal motor-starting devices.
- as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058‑1‑1.
This document applies to
- the inherent safety of motor-starting control, and
- functional safety of motor-starting control and safety related systems (when required),
- controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
- the operating values, operating times, and operating sequences where such are associated with equipment safety,
- motor-starting controls incorporating electronic devices, thermistor elements, thermal elements or magnetic elements.
This document specifies the requirements for construction, operation and testing of automatic electrical motor-starting relays used in, on, or in association with an equipment.
This document does not
- apply to motor-starting relays designed exclusively for industrial process applications unless explicitly mentioned in the relevant equipment standard. However, this document can be applied to motor-start relays for equipment intended specifically for industrial applications in cases where no relevant safety standard exists;
- take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer will apply;
- apply to general purpose relays or to contactors and motor starters of the type covered by IEC 60947 series;
apply to mechanically operated motor-starting devices
This part 2‑10 is intended to be used in conjunction with IEC 60730‑1. It was established on the basis of the sixth edition of that standard (2022). Consideration may be given to future editions of, or amendments to, IEC 60730‑1.
This part 2‑10 supplements or modifies the corresponding clauses in IEC 60730‑1, so as to convert that publication into the IEC standard: Particular requirements for motor-starting relays.
Where this part 2‑10 states "addition", "modification" or "replacement",
- Standard16 pagesEnglish languagesale 15% off
- Standard295 pagesEnglish languagesale 15% off
- Standard17 pagesFrench languagesale 15% off
IEC 60730-2-22:2014 applies to the partial evaluation of thermal motor protectors as defined in IEC 60730-1 for household and similar use, including heating, air conditioning and similar applications as well as for sealed (hermetic and semi-hermetic type) motor-compressors. A thermal motor protector is considered an integrated control since its protective functionality is dependent on the correct mounting and fixing in or on a motor and which can only be fully tested in combination with the relevant motor. This dependency is illustrated by:
- the ability of the thermal motor protector to accurately and reliably sense the heat of the motor windings;
- thus, addressing the over-temperature protection due to motor overload conditions;
- the ability of the thermal motor protector to accurately and reliably sense the current due to motor locked-rotor conditions;
- thus, reducing the response time and not being adversely affected by heat-sink at the assembly spot in the application and the influence of the motor's electromagnetic field on the switch behaviour of the thermal motor protector;
- particularly, affecting the arc direction between the contacts resulting in uneven wear of the contact material and eventually leading to failure of operation. Requirements concerning the testing of the combination of sealed (hermetic and semi-hermetic type) motor-compressors and thermal motor protectors are given in IEC 60335-2-34. This standard applies to thermal motor protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. Key words: Thermal, Motor protectors, Integrated control
This publication is to be read in conjunction with IEC 60730-1:2010.
- Standard58 pagesEnglish and French languagesale 15% off
This part of IEC 60730 applies to controls for automatically controlling the starting windings of single phase motors associated with equipment for household and similar use. This standard applies to motor-starting relays using NTC or PTC thermistors, additional requirements for which are contained in Annex J.
- Standard21 pagesEnglish and French languagesale 15% off
This part of IEC 60730 applies to the evaluation of thermal protectors for ballasts for tubular fluorescent lamps. This standard applies to thermal protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. Requirements concerning the testing of the combination of ballasts and thermal protectors are given in IEC 61347-1.
- Standard29 pagesEnglish and French languagesale 15% off
Applies to the partial evaluation and inherent safety of thermal motor protectors for motor-compressors within the scope of IEC 60335-1.
- Standard35 pagesEnglish and French languagesale 15% off
Applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of thermal protectors for ballasts for tubular fluorescent lamps supplied up to 600 V (50 Hz or 60 Hz).
- Standard31 pagesEnglish and French languagesale 15% off
- Standard7 pagesEnglish and French languagesale 15% off
- Standard7 pagesEnglish and French languagesale 15% off
- Standard7 pagesEnglish and French languagesale 15% off
This part of IEC 60730 applies to the partial evaluation of thermal motor protectors as defined in IEC 60730-1 for sealed (hermetic and semi-hermetic type) motor-compressors. A thermal motor protector is an integrated control which is dependent on its correct mounting and fixing in or on a motor and which can only be fully tested in combination with the relevant motor. Requirements concerning the testing of the combination of motor and thermal motor protectors are given in IEC 60335-2-34. This standard applies to thermal motor protectors for motor compressors using NTC or PTC thermistors, additional requirements for which are contained in Annex J.
- Standard41 pagesEnglish and French languagesale 15% off
Applies to the partial evaluation of thermal motor protectors and their inherent safety. Applies also to thermal motor protectors within the scope of IEC 60335-1.
- Standard45 pagesEnglish and French languagesale 15% off
- Standard45 pagesEnglish and French languagesale 15% off
- Standard11 pagesEnglish and French languagesale 15% off
Frequently Asked Questions
WG 3 is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "TC 72/WG 3". This committee has published 730 standards.
WG 3 develops IEC standards in the area of Information technology. Currently, there are 730 published standards from this technical committee.
The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.
A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.