MT 60079-28 - TC 31/MT 60079-28
TC 31/MT 60079-28
General Information
Frequently Asked Questions
MT 60079-28 is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "TC 31/MT 60079-28". This committee has published 2 standards.
MT 60079-28 develops IEC standards in the area of Information technology. Currently, there are 2 published standards from this technical committee.
The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.
A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.
IEC 60079-28:2025 specifies additional requirements for Ex Equipment, Ex associated equipment or Ex Components containing optical systems emitting optical radiation, which is exposed to explosive atmospheres. These additional requirements are applicable for all equipment groups and all Equipment Protection Levels (EPL).
This document contains requirements for optical radiation in the wavelength range from 380 nm to 10 µm. It covers the following ignition mechanisms:
• Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this might allow them to attain a temperature which will ignite a surrounding explosive atmosphere.
• In rare special cases, direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point.
• Annex A provides guidance when considering ignition mechanisms that influence the hazard of optics in explosive atmospheres.
This document applies to
a) laser equipment; and
b) optical fibre equipment; and
c) any optical system that converts light into convergent beams with focal points within the hazardous area only.
This document does not apply to:
d) laser equipment for EPL Mb, Gb, Gc, Db or Dc applications which complies with Class 1 limits in accordance with IEC 60825-1; or
e) Single or multiple optical fibre cables not part of optical fibre equipment if the cables:
1) comply with the relevant industrial standards for optical fibre cables, along with additional protective means, for example robust cabling, conduit or raceway (for EPL Gb, Db, Mb, Gc or Dc); or
2) comply with the relevant industrial standards for optical fibre cables (for EPL Gc or Dc); or
f) Optical radiation sources as defined in i) to iii) above where the optical radiation is fully contained in an enclosure complying with one of the following Types of Protection suitable for the EPL, or the minimum ingress protection rating specified:
1) flameproof "d" enclosures (IEC 60079-1); or
2) pressurized "p" enclosures (IEC 60079-2); or
3) restricted breathing "nR" enclosure (IEC 60079-15); or
4) dust protection "t" enclosures" (IEC 60079-31); or
5) an enclosure that provides a minimum ingress protection of IP 6X and where no internal absorbers are to be expected and complying with "Tests of enclosures" in IEC 60079-0.
This document does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this document.
This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence.
This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision
- Standard30 pagesEnglish languagesale 15% off
- Standard32 pagesFrench languagesale 15% off
- Standard62 pagesEnglish and French languagesale 15% off
IEC 60079-28:2015 specifies the requirements, testing and marking of equipment emitting optical radiation intended for use in explosive atmospheres. It also covers equipment located outside the explosive atmosphere or protected by a Type of Protection listed in IEC 60079-0, but which generates optical radiation that is intended to enter an explosive atmosphere. It covers Groups I, II and III, and EPLs Ga, Gb, Gc, Da, Db, Dc, Ma and Mb. This standard does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this standard. This second edition cancels and replaces the first edition, published in 2006, and constitutes a technical revision. Refer to the Foreword of the document for a complete listing of the technical changes between edition 2.0 and previous edition of the document. Keywords: equipment emitting optical radiation intended for use in explosive atmospheres
The Interpretation sheet 1 of November 2019 have been included in this copy.
- Standard51 pagesEnglish languagesale 15% off
- Standard79 pagesEnglish and French languagesale 15% off