CLC/SC 31-7 - Pressurization and other techniques
To standardize specific requirements for the construction and testing of electrical apparatus, type of protection "p", including that with an internal source of flammable gas and vapour intended for use in potentially explosive atmospheres.
Okrov z notranjim nadtlakom
To standardize specific requirements for the construction and testing of electrical apparatus, type of protection "p", including that with an internal source of flammable gas and vapour intended for use in potentially explosive atmospheres.
General Information
1.1 This European Standard contains the specific requirements for the construction and testing of transportable ventilated rooms (TVR's), such as skid mounted analyser houses with type of protection 'v' intended for use in potentially explosive atmospheres. Transportable in this sense means manufactured in one location (the manufacturer's premises) for trade and transportation to another location (the user's premises) for installation and use. This European Standard supplements European Standard EN 50014 or where appropriate EN 50021, the requirements of which apply to electrical apparatus with type of protection 'v' except as modified within this standard. This standard does not contain the requirements for equipment group II, category 1 or equipment group I, category M1. This standard does not contain the requirements for equipment group I, category M2 where there exists a potential source of release. This standard does not contain the requirements for group II where there exists a potential hazard from combustible dusts. NOTE It is not the intention of this European Standard to cover stationary analyzer houses according to EN 61285. 1.2 This European Standard includes the requirements for the construction of the TVR and its associated components including, the inlet and outlet apertures for the ventilation gas supply and for the safety provisions and devices necessary for the type of protection 'v'. 1.3 This European Standard specifies the requirements for TVR's with or without an internal source of release of potentially flammable or toxic, gas, liquid or vapour (for example analyzers placed within the TVR). 1.4 Due to the safety factors incorporated in the type of protection, the uncertainty of measurement inherent in good quality, regularly calibrated measurement equipment is considered to have no significant detrimental effect and need not be taken into account when making the measurements necessary to verify compliance of the apparatus with the requirements of this standard.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60079 contains the specific requirements for the construction and testing of electrical apparatus with pressurized enclosures, of type of protection 'p', intended for use in explosive gas atmospheres. It specifies requirements for pressurized enclosures containing a limited release of a flammable substance. The significant changes with respect to the previous edition is the introduction of the 'Equipment protection level concept'.
- Standard61 pagesEnglish languagesale 10% offe-Library read for1 day
SC to prepare amendment to cover the essential requirements of ATEX directive (formal vote) * Supersedes EN 50016:2002 * Corrigendum to EN issued April 2006 * Superseded by EN 60079-2:2007
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60079-2:2004
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard contains the specific requirements for the construction and testing of electrical apparatus with type of protection pressurization p intended for use in potentially explosive atmospheres. This European Standard supplements European Standard EN 50014, the requirements of which apply to electrical apparatus with type of protection p. This European Standard includes the requirements for the construction of the enclosure and its associated components, including if any, the inlet and outlet ducts for the protective gas, and for the safety provisions and devices necessary for the type of protection pressurization p. This European Standard specifies the requirements for pressurized enclosures with or without an internal source of release, with the exceptions given hereafter. This European Standard specifies requirement for pressurized enclosures containing an unlimited source of release of flammable gas or vapour only where the unlimited source of release is from the surface of a liquid. This European Standard does not contain requirements for pressurized rooms or analyser houses. This European Standard does not contain the requirements for pressurized enclosures where, in a containment system with limited or unlimited release there is: air with an oxygen content greater than normal, or oxygen in combination with inert gas in a proportion greater than 21%. Due to the safety factors incorporated in the type of protection the uncertainty of measurement inherent in good quality, regularly calibrated measurement equipment is considered to have no significant detrimental effect and need not be taken into account when making the measurements necessary to verify compliance of the apparatus with the requirements of this standard
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50016:1995