CLC/TC 79/WG 02 - Detection devices for intruder alarm systems
Detection devices for intruder alarm systems
General Information
This document is for microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131 1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130 5). This document does not include requirements for detectors intended for use outdoors. The purpose of the detector is to emit microwave signals and analyse the signals that are returned to detect an intruder and to provide the necessary range of signals or messages to be used by the rest of the intrusion alarm system. The grade-dependent requirements of this document apply and it is essential that a detector fulfils all the requirements of the specified grade. Functions additional to the mandatory functions specified in this document can be included in the detector, providing they do not influence the correct operation of the mandatory functions. Requirements for system interconnections are not included in this document.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
This document is for passive infrared detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131 1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130 5). This document does not include requirements for detectors intended for use outdoors. The purpose of the detector is to detect the broad spectrum infrared radiation emitted by an intruder, to analyse the resulting signals and to provide the necessary range of signals or messages to be used by the rest of the intrusion alarm system. The grade-dependent requirements of this document apply and it is essential that a detector fulfils all the requirements of the specified grade. Functions additional to the mandatory functions specified in this document can be included in the detector, providing they do not influence the correct operation of the mandatory functions. Requirements for system interconnections are not included in this document.
- Standard53 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for passive infrared detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive infrared detectors intended for use outdoors. It is essential that a detector fulfils all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions. This European Standard does not apply to system interconnections.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
This document is for Shock Detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows). It specifies four security Grades 1-4 (in accordance with EN 50131 1), specific or non-specific wired or wire-free shock detectors and uses environmental Classes I-IV (in accordance with EN 50130 5). This document does not include requirements for detectors intended to detect penetration attacks on safes and vaults for example by drilling, cutting or thermal lance. This document does not include requirements for shock detectors intended for use outdoors. A shock detector needs to fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this document can be included in the shock detector, providing they do not adversely influence the correct operation of the mandatory functions. This document does not deal with requirements for compliance with regulatory directives, such as EMC-directive, low-voltage directive, etc., except that it specifies the equipment operating conditions for EMC- susceptibility testing as required by EN 50130 4. This document does not apply to system interconnections.
- Draft43 pagesEnglish languagesale 10% offe-Library read for1 day