CEN/TC 264/WG 35 - Standard method for measurement of OC and EC deposited on filters
Standard method for measurement of OC and EC deposited on filters
General Information
This document provides definitions of the quantities measured by various candidate methods, their basic principles, and their advantages and disadvantages.
Currently no traceable primary reference materials are available for EC and OC analyses. This document provides guidance to test the equivalence between candidate methods and EN 16909 for EC and/or OC determination(s), based on EN 16450.
- Technical report17 pagesEnglish languagesale 10% offe-Library read for1 day
This document describes procedures to assess the applicability of the standard method EN 16909 (determination of OC and EC deposited on filters) to particle size fractions up to 10 µm in aerodynamic diameter (50 % cut off).
- Technical report21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard gives guidance on the measurement of elemental carbon (EC) and organic carbon (OC) following the requirement for the networks of all EU member states to measure EC and OC in particulate matter from June 2010 at background sites according to the Council Directive 2008/50/EC on ambient air quality and cleaner air for Europe [1].
This European Standard describes the analytical procedures for determining EC and OC on quartz fibre filters as μg/cm2, and the subsequent calculation of concentrations as µg/m3. Sampling onto filters is to be done in accordance with EN 12341:2014 for PM2,5. The sampling process determines the size fraction of the particulate matter, the retention of semi-volatile material, and uptake/loss of volatile organic compounds on the filter at the time of sampling.
The same analysis method may also be used for smaller size fractions than PM2,5. Any possible additional artefacts for larger particles, e.g. pyrolysis or higher concentrations of carbonates, should be assessed.
The scope includes rural background, urban background, road side and industrial measurement sites, to allow the assessment of additional exposure of people in urban areas as stated in the objectives of the council directive and to achieve coherence in the European approach.
The applicable concentration range of the proposed method is limited by the optical correction and instrument applied in the analysis of EC and OC. This method was validated from 0,2 µg CEC/cm² and 1,8 µg COC/cm² to 38 µg CEC/cm² and 49 µg COC/cm² in the laboratory and to 16 µg CEC/cm² and 45 µg COC/cm² in the field.
- Standard56 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report gives guidance on the measurement of elemental carbon (EC) and organic carbon (OC) following the requirement for the networks of all EU member countries to measure EC and OC in particulate matter from June 2010 at background sites according to the Council Directive 2008/50/EC on ambient air quality and cleaner air for Europe.
The Technical Report describes the analytical procedures for determining EC and OC on quartz fibre filters as μg/cm2, and the subsequent calculation of concentrations as µg/m³. Sampling onto filters is to be done in accordance with EN 14907 for PM2,5. The sampling process determines the size fraction of the particulate matter, the retention of semi-volatile material, and ab/desorption of volatile organic compounds on the filter at the time of sampling.
The same analysis method may also be used for other size fractions. Any possible additional artefacts e.g. due to charring or higher concentrations of carbonates would need to be assessed in those cases.
The measurement procedures are applicable for:
- rural background,
- urban background,
- road side and
- industrial sites.
The scope includes non rural site measurements, to allow the assessment of additional exposure of people in urban areas as stated in the objectives of the council directive and to achieve coherence in the European approach. Measurements are made over a nominal sampling period of 24 h, and concentrations are expressed as μg/m³, where the volume of air is the volume at ambient conditions near the inlet of the sampler at the time of sampling.
The applicable concentration range of the proposed method is limited by the optical correction, instrument, and thermal protocols applied in the analysis of EC and OC. Therefore no definitive values can be given. The experience from EMEP shows the applicability of the method at regional background sites.
- Technical report29 pagesEnglish languagesale 10% offe-Library read for1 day