This CEN Technical Report provides guidance only on the application of the European Standard EN ISO 16911-1:2013.
This CEN Technical Report does not provide guidance on the application of EN ISO 16911-2:2013.
- Technical report40 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 16911-1:2013 specifies a method for periodic determination of the axial velocity and volume flow rate of gas within emissions ducts and stacks. It is applicable for use in circular or rectangular ducts with measurement locations meeting the requirements of EN 15259. Minimum and maximum duct sizes are driven by practical considerations of the measurement devices described within ISO 16911-1:2013.
ISO 16911-1:2013 requires all flow measurements to have demonstrable metrological traceability to national or international primary standards.
To be used as a standard reference method, the user is required to demonstrate that the performance characteristics of the method are equal to or better than the performance criteria defined in ISO 16911-1:2013 and that the overall uncertainty of the method, expressed with a level of confidence of 95 %, is determined and reported. The results for each method defined in ISO 16911-1:2013 have different uncertainties within a range of 1 % to 10 % at flow velocities of 20 m/s.
Methods further to these can be used provided that the user can demonstrate equivalence, based on the principles of CEN/TS 14793.
- Standard94 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 16911-2:2013 describes specific requirements for automated measuring system (AMS) flow monitoring. It is partly derived from EN 14181 which is the general document on the quality assurance of AMSs and is applicable in conjunction with that document.
ISO 16911-2:2013 specifies conditions and criteria for the choice, mounting, commissioning and calibration of AMSs used for determining the volume flow rate from a source in ducted gaseous streams. ISO 16911-2:2013 is applicable by correlation with the manual reference methods described in ISO 16911-1.
ISO 16911-2:2013 is primarily developed for monitoring emissions from waste incinerators and large combustion plants. From a technical point of view, it can be applied to other processes for which flow rate measurement is required with a defined and minimized uncertainty.