CEN/TC 72/WG 5 - Point heat and smoke detectors and short-circuit isolators
To prepare and maintain product standards for point heat and smoke detectors and for short-circuit isolators.
Point heat and smoke detectors and short-circuit isolators
To prepare and maintain product standards for point heat and smoke detectors and for short-circuit isolators.
General Information
This draft European Standard specifies requirements, test methods and performance criteria for point smoke detectors that operate using scattered light, transmitted light or ionization, intended for use in fire detection and fire alarm systems installed in and around buildings (see EN 54 1:2011).
This European standard provides for the assessment of verification of consistency of performance (AVCP) of point smoke detectors to this EN.
For other types of smoke detector, or smoke detectors working on different principles, this standard should only be used for guidance. Smoke detectors with special characteristics and developed for specific risks are not covered by this standard.
NOTE Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this standard.
- Standard79 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, test methods and performance criteria for point heat detectors intended for use in fire detection and fire alarm systems installed in and around buildings (see EN 54-1:2011).
This European Standard provides for the assessment of verification of constancy of performance (AVCP) of point heat detectors to this EN.
For other types of heat detector, or for detectors intended for use in other environments, this standard should only be used for guidance.
Heat detectors with special characteristics and developed for specific risks are not covered by this standard.
- Standard62 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements, test methods and performance criteria for short-circuit isolators, for use in fire detection and fire alarm systems for buildings (see EN 54-1).
Means of isolation or protection incorporated within control and indicating equipment (Item B in Figure 1 of EN 54-1:1996) are not covered by this European Standard.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
AFNOR - 5.1.5.2, 1st paragraph - Translation correction
- Corrigendum2 pagesFrench languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, test methods and performance criteria for point heat detectors for use in fire detection and fie alarm systems for buildings (see EN 54-1: 1996).
For other types of heat detector, or for detectors intended for use in other environments, this standard should only be used for guidance. Heat detectors with special characteristics and developed for specific risks are not covered by this standard.
- Draft61 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, test methods and performance criteria for point smoke detectors that operate using scattered light, transmitted light or ionization, for use in fire detection and fie alarm systems for buildings (see EN 54-1: 1996).
For other types of smoke detector, or for smoke detectors working on different principles, this standard should only be used for guidance. Smoke detectors with special characteristics and developed for specific risks are not covered by this standard.
- Draft80 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, test methods and performance criteria for point heat detectors intended for use in fire detection and fire alarm systems installed in and around buildings (see EN 54-1:2011).
This European standard provides for the evaluation of conformity (EoC) of point heat detectors to this EN.
For other types of heat detector, or for detectors intended for use in other environments, this standard should only be used for guidance.
Heat detectors with special characteristics and developed for specific risks are not covered by this standard.
- Standard72 pagesEnglish languagesale 10% offe-Library read for1 day