Abstract

ISO 15106-2:2003 specifies an instrumental method for determining the water vapour transmission rate of plastic film, plastic sheeting and multi-layer structures including plastics, using an infrared detection sensor.
NOTE The method provides rapid measurement over a wide range of water vapour transmission rates.

Status
Published
Publication Date
30-Apr-2005
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-May-2005
Due Date
01-May-2005
Completion Date
01-May-2005

Buy Documents

Standard

SIST EN ISO 15106-2:2005

English language (7 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN ISO 15106-2:2005 is the Slovenian adoption of EN ISO 15106-2:2005, based on ISO 15106-2:2003. It specifies an instrumental method, using an infrared detection sensor, for determining the water vapour transmission rate of plastic film, plastic sheeting and multi-layer structures including plastics. It is used by laboratories, manufacturers and quality teams that need comparable WVTR data for barrier materials.

What does SIST EN ISO 15106-2:2005 specify?

SIST EN ISO 15106-2:2005 specifies the infrared detection sensor method for water vapour transmission rate testing. In the ISO 15106 series, this part sits alongside the humidity detection sensor method and the electrolytic detection sensor method, so it tells users which test principle to apply when the infrared approach is wanted.

The document is organized into clauses 1 to 13:

  • scope
  • normative references
  • terms and definitions
  • principle
  • test specimens
  • conditioning
  • apparatus
  • test conditions
  • procedure
  • calculation
  • test result
  • precision
  • test report

That structure matters in practice because it takes a lab from sample preparation through to the final reported WVTR value.

What are the key requirements of SIST EN ISO 15106-2:2005?

Specimens and conditioning

SIST EN ISO 15106-2:2005 requires specimens that are representative, free from wrinkles, creases and pinholes, and of uniform thickness. Each specimen must be larger than the transmission area of the cell and mounted hermetically, because leakage or poor fit will distort the measured vapour flow.

The standard uses three specimens unless the interested parties agree otherwise, and it allows more specimens where that gives a more representative result. Thickness is measured at three equally spaced points in accordance with ISO 4593, and specimens are conditioned at 23 °C ± 2 °C and (50 ± 10) % RH for the time stated for the material.

Apparatus and test conditions

SIST EN ISO 15106-2:2005 describes a transmission cell with a wet chamber and a dry chamber, an infrared sensor, a pump, a flow meter, a drying tube and valves. The transmission area must be between 5 cm² and 100 cm², the cell temperature held within ± 0.5 °C of the test temperature, and the flow meter able to measure 5 ml to 100 ml per minute.

The infrared detection sensor must detect a change in water vapour content of either 1 µg per litre or 1 mm³/dm³, which is given as 1 ppm by volume. The drying tube must dry the air to the sensor’s detection limit or lower, and maintenance and calibration follow the manufacturer’s instructions. Preferred test conditions are listed as temperature and RH combinations, and any other conditions must be agreed between the interested parties.

Procedure, calculation and reporting

SIST EN ISO 15106-2:2005 starts with a reference test specimen, then measures each test specimen against it. The operator first checks zero level with dried air, prepares a suitable saturated solution to set the lower chamber humidity, mounts the specimen hermetically, and then waits for the sensor output to reach steady state within ± 5 %.

The WVTR is calculated from the reference specimen, the test specimen, their steady-state voltages and their transmission areas. The final test result is the arithmetic mean of the specimen results, rounded according to the rule in the standard. The test report must identify the standard used, the test conditions, the reference specimen, sample details, specimen preparation, the side exposed to water vapour, area, thickness, number of specimens, conditioning, any steady-state instability, the result and the test date.

What terms does SIST EN ISO 15106-2:2005 define?

  • Water vapour transmission rate (WVTR) - the amount of water vapour that passes through unit area of a test specimen per unit time under specified conditions.
  • Reference test specimen - a specimen with known WVTR, or one measured in accordance with ISO 2528, used to support the test calculation.
  • Transmission cell - the two-chamber cell that holds the specimen between the wet and dry sides during the test.
  • Relative humidity (RH) - the humidity level used in conditioning and test conditions.
  • Steady state - the condition where the infrared sensor output has stabilized enough for the test to be read and calculated.
  • Test specimen - the sample of film, sheeting or multi-layer structure taken for measurement.

Who uses SIST EN ISO 15106-2:2005?

SIST EN ISO 15106-2:2005 is used in the plastics film and sheeting sector, especially for barrier materials and multi-layer structures. Test laboratories use it to generate WVTR values, manufacturers use it for product development and routine quality control, and buyers or specifiers use it when comparing packaging or sheet materials for moisture barrier performance.

What changed in SIST EN ISO 15106-2:2005 from the previous edition?

SIST EN ISO 15106-2:2005 takes over ISO 15106-2:2003 and was approved by CEN as EN ISO 15106-2:2005 without modifications.

Which standards are used with SIST EN ISO 15106-2:2005?

  • ISO 2528:1995 - provides the gravimetric dish method used to determine the WVTR of the reference test specimen.
  • ISO 4593:1993 - gives the mechanical scanning method for measuring specimen thickness.
  • ISO 15106-1 - the humidity detection sensor method in the same series.
  • ISO 15106-3 - the electrolytic detection sensor method in the same series.

What does the SIST EN ISO 15106-2:2005 document contain?

The document contains the test principle, specimen requirements, conditioning, apparatus description, preferred test conditions, procedure, calculation, test result rules, precision statement and test report items. It also includes Figure 1 for the example apparatus and Table 1 for the preferred temperature and RH combinations. Clause 10 gives the calculation basis, which is useful for software, spreadsheets and laboratory calculation sheets, while Clause 13 lists the report items needed for traceable testing.

Relations

Effective Date
25-Aug-2026
Effective Date
28-Jan-2026
Effective Date
09-Feb-2026

Buy Documents

Standard

SIST EN ISO 15106-2:2005

English language (7 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Smithers Quality Assessments

US management systems and product certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

SIST EN ISO 15106-2:2005 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Plastics - Film and sheeting - Determination of water vapour transmission rate - Part 2: Infrared detection sensor method (ISO 15106-2:2003)". This standard covers: ISO 15106-2:2003 specifies an instrumental method for determining the water vapour transmission rate of plastic film, plastic sheeting and multi-layer structures including plastics, using an infrared detection sensor. NOTE The method provides rapid measurement over a wide range of water vapour transmission rates.

ISO 15106-2:2003 specifies an instrumental method for determining the water vapour transmission rate of plastic film, plastic sheeting and multi-layer structures including plastics, using an infrared detection sensor. NOTE The method provides rapid measurement over a wide range of water vapour transmission rates.

SIST EN ISO 15106-2:2005 is classified under the following ICS (International Classification for Standards) categories: 83.140.10 - Films and sheets. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN ISO 15106-2:2005 has the following relationships with other standards: It is inter standard links to SIST ISO 2528:1996, SIST EN 4343:2004, SIST EN IEC 62788-6-2:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN ISO 15106-2:2005 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 water vapour transmission rate
  • 3.2 reference test specimen
  • 4 Principle
  • 5 Test specimens
  • 6 Conditioning
  • 7 Apparatus
  • 1 Specimen 6 Infrared sensor
  • 2 Transmission cell 7 Recorder
  • 3 Cotton wool soaked in suitable solution 8 Control valve
  • 4 Switch valve 9 Flow meter
  • 5 Pump 10 Drying tube
  • 8 Test conditions
  • 9 Procedure
  • 10 Calculation
  • 11 Test result
  • 12 Precision
  • 13 Test report

1 Scope

This part of ISO 15106 specifies an instrumental method for determining the water vapour transmission rate of plastic film, plastic sheeting and multi-layer structures including plastics, using an infrared detection sensor. NOTE The method provides rapid measurement over a wide range of water vapour transmission rates.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

ISO 2528:1995, Sheet materials — Determination of water vapour transmission rate — Gravimetric (dish) method ISO 4593:1993, Plastics — Film and sheeting — Determination of thickness by mechanical scanning

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

3.1 water vapour transmission rate

the amount of water vapour transmitted through unit area of test specimen per unit time under specified conditions

NOTE Water vapour transmission rate is expressed in grams per square metre 24 hours [g/(m ⋅24 h)].

3.2 reference test specimen

a test specimen whose water vapour transmission rate is known, or one for which the water vapour transmission rate has been determined in accordance with ISO 2528

SIST EN ISO 15106-2:2005 ISO 15106-2:2003(E)

4 Principle

A dry chamber, at a specified relative humidity, is separated from a wet chamber, in which the atmosphere is saturated with water vapour at a known temperature, by a sheet of the material to be tested. The change in humidity brought about by water vapour transmitted through the specimen is detected by an infrared sensor capable of providing an electrical output signal which is a measure of the relative humidity in the dry chamber. The time taken to reach a steady state is measured and converted into a water vapour transmission rate.

5 Test specimens

5.1 The specimens shall be representative of the material, be free from wrinkles, creases and pinholes, and have uniform thickness. Each specimen shall have a larger area than the transmission area of the cell used for the test, and shall be hermetically mounted.

5.2 Three specimens shall be used unless otherwise specified or agreed between the interested parties. NOTE For some products, testing more than three specimens gives a more representative result. 5.3 Unless otherwise specified, determine the thickness of each specimen in accordance with ISO 4593 at three points that are equally spaced.

6 Conditioning

Condition the specimens at 23 °C ± 2 °C and a relative humidity of (50 ± 10) %. The period of conditioning shall be as stated in the relevant specification for the material.

...