SIST ISO 49:2001/TC 1:2001
(Main)ISO 49:1994/Cor 1:1997
ISO 49:1994/Cor 1:1997
Replaces the first line in subclause 5.3 and replaces subclause 11.7 by a new wording.
Raccords en fonte malléable filetés conformément à l'ISO 7-1 — Rectificatif technique 1
Fitingi iz temprane litine z navoji po ISO 7-1 - Tehnični popravek 1
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.ISO 49:1994/Cor 1:199723.040.40Kovinski fitingiMetal fittingsICS:Ta slovenski standard je istoveten z:ISO 49:1994/Cor 1:1997SIST ISO 49:2001/TC 1:2001en01-september-2001SIST ISO 49:2001/TC 1:2001SLOVENSKI
STANDARD
INTERNATIONAL STANDARD IS0 49:1994 TECHNICAL CORRIGENDUM 1 Published 1997-02-E INTERNATIONAL ORGANIZATION FOR STANDARDIZATION l MEWWHAPOLWA~ OP~AHM3ALlMfI l-l0 CTAHjJAPTM3AL/MM. ORGANISATION INTERNATIONALE DE NORMALISATION Malleable cast iron fittings threaded to IS0 7-1 TECHNICAL CORRIGENDUM 1 Raccords en fonte mall&able filet& conformbment 2 I’ISO 7-1 RECTIFICA T/F TECHNIQUE I Technical Corrigendum 1 to International Standard IS0 49:1994 was prepared by Technical Committee ISO/TC 5, Ferrous metal pipes and metallic fittings, Subcommittee SC 5, T
...
This May Also Interest You
This European Standard is a complementary document for the installation of ductile iron pipes, fittings, accessories and their joints, covered by EN 598:2009 harmonized standard. It is intended to describe, in a wider perspective, installation technologies, tools and pipelines particular examples, applicable for the construction, outside buildings, of:
- Drainage pipeline systems;
- Raw water pipeline systems;
- Sewage pipeline systems;
- Pipeline systems conveying surface water (e.g. rainwater), domestic waste water and/or certain types of industrial effluents, either in separate systems or in combined systems;
- Operating without pressure (gravity sewers) or with positive or negative pressure;
- Below or above ground installation types.
It also gives some site operation/site instructions for the application of fittings, intended to be used for the connection of ductile iron drains and sewers to other materials as plastic, concrete, vitrified clay, etc.
This European Standard is not intended to cover:
- Hydraulic design of drains and sewers systems outside buildings. For this purpose, EN 16933-2 applies.
- Construction and site testing of drains and sewers. For this purpose, EN 1610 applies.
- Trenchless construction and testing of drains and sewers. For this purpose, EN 12889:2000 applies
- Technical report56 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies product characteristics, test/assessment methods and how to express test/assessment results. Cast iron pipelines kits are usually composed of cast iron pipes, fittings, joints and accessories.
This document covers the range of nominal diameter from DN 40 to DN 600 inclusive.
The cast iron includes grey cast iron and ductile cast iron.
The roof gullies used for siphonic systems are outside the scope of this document.
Sewerage applications are outside the scope of this document.
It is intended to be used for the construction of gravity or vacuum discharge pressurized or unpressurised networks installed inside and/or outside works, above and/or below ground and in construction works.
- Standard57 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard57 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the requirements and test methods applicable to factory applied internal lining made of thermoplastic acid modified polyolefin (TMPO) for the heavy duty corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969. This document also applies to pipes with only socket and spigot ends coated with TMPO. Fittings and accessories are covered separately by EN 14901-2.
- Standard21 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the requirements and test methods applicable to factory applied extruded polyethylene coatings for the external corrosion protection of ductile iron pipes according to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
This document is not applicable to ductile iron pipes protected with thin PE sleeve. Special works at site like drilling, tapping, etc. can influence the corrosion protection properties. Those job steps are intended to be included in the instructions of pipe saddle and accessory manufacturers and all other essential installation instructions. These instructions are not part of this document.
- Standard24 pagesEnglish languagesale 10% offe-Library read for×1 day
This document defines the requirements and test methods for factory applied thermoplastic acid modified polyolefin (TMPO) coatings used for the protection of ductile iron fittings and accessories according to EN 545, EN 598, EN 969, EN 12842 and EN 14525:
- conveying water (e.g. potable water, raw water, …) at operating temperature up to 50 °C; or
- conveying waste water at operating temperature up to 45 °C; or
- conveying gas at operating temperature up to 50 °C;
- suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in D.2.3 of EN 545:2010.
- Standard17 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder or liquid two-pack) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
- conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
- conveying waste water at operating temperature up to 45 °C excluding frost; or
- conveying gas at operating temperature up to 50 °C;
- suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in EN 545:2010, D.2.3.
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard defines the requirements and test methods applicable to factory applied internal polyurethane high duty corrosion protection of buried ductile iron pipes and fittings conforming to EN 545, EN 598 and EN 969 for use at permanent operating temperatures up to 45 °C
- Standard23 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Amendment5 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron fittings, ductile iron and mild steel couplings and flange adaptors and their joints to be used with poly(vinyl chloride) (PVC-U) pipes or polyethylene (PE) pipes. It is in conformity with EN 1452-1 to -5, ENV 1452-6 and -7 and EN 12201-1 to -5 respectively, for the construction of pipelines:
- to convey water (e.g. water intended for human consumption);
- with or without pressure;
- to be installed below or above ground, inside or outside buildings.
This European Standard is not intended to cover sewerage applications, where additional requirements may be necessary.
This European Standard is applicable to fittings which are:
- manufactured with socketed, flanged or spigot ends;
- supplied externally and internally coated;
- suitable for PE and PVC-U pipes with fluid temperatures between 0°C and 25°C, excluding frost, and for pressures up to 16 bar (PFA). For higher temperatures (up to 45°C for PVC-U or 40°C for PE) the PFA is derated as given in EN 1452 and EN 12201;
- not intended for use in areas subjected to reaction to fire regulations.
NOTE 1 This does not preclude special arrangements for the products to be used at higher temperatures. Temperature limitations and pressure limitations are those coming from the PVC-U or PE pipes.
This European Standard covers ductile iron fittings, couplings and flange adaptors cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, in a size range extending from DN 60 to DN 700, to be used with pipes of external diameter from 63 mm to 710 mm.
As long as no equivalent European Standard exists for mild steel accessories, this European Standard also covers couplings and flange adaptors for use with PVC-U and PE pipes which are fabricated partly or entirely from mild steel as well as corresponding joints, in a size range extending from DN 60 to DN 700, to be used with pipes of external diameter from 63 mm to 710 mm.
This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings. It also gives minimum performance requirements for all components, including restrained and non-restrained flexible joints. Joint design and gasket shapes are outside the scope of this standard.
This European Standard does not cover fittings, couplings and flange adaptors intended to be used with different pipe materials other than PVC-U and PE.
NOTE 2 Fittings, couplings and flange adaptors complying with the requirements of this European Standard for PVC-U also usually meet the requirements for PVC-O and PVC-A pipes. Where this is not the case, the manufacturer is expected to declare this in the relevant literature.
NOTE 3 In this European Standard, all pressures are relative pressures, expressed in bars (100 kPa = 1 bar).
- Standard49 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of pipelines outside buildings:
- to convey different types of water (e.g. raw water, treated water, re-used water) for all types of applications (e.g. water intended for human consumption, for fire protection, for snow making, for irrigation, for hydro-electricity etc.);
- with or without pressure;
- to be installed below or above ground.
This European Standard is applicable to pipes, fittings and accessories which are:
- manufactured with socketed, flanged or spigot ends;
- supplied externally and internally coated;
- suitable for fluid temperatures between 0 °C and 50 °C, excluding frost;
- not intended for use in areas subject to fire regulations.
NOTE 1 This does not preclude special arrangements for the products to be used at higher temperatures.
This European Standard covers pipes and fittings cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints and accessories, in a size range extending from DN 40 to DN 2 000, inclusive.
This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron pipes and fittings. It also gives performance requirements for all components including joints. Joint design and gasket shapes are outside the scope of this standard.
In addition, reference is made to the performance requirements of couplings, flange adaptors and saddles manufactured for use with ductile iron pipes and fittings.
NOTE 2 In this European Standard, all pressures are relative pressures, expressed in bars (100 kPa = 1 bar).
- Standard93 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard + National Annex and/or Foreword96 pagesForeword and/or annex in Slovenian language, body of the standard in English languagesale 10% offe-Library read for×1 day
- 13-Mar-2011
- 23.040.10
- 23.040.40
- 91.140.60
- 89/106/EEC
- TLP








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...