Fibre optic interconnecting devices and passive components - Fibre optic connector optical interfaces - Part 3-32: Optical interface, 8 degrees angled PC, thermoset epoxy rectangular ferrule, single mode fibres

IEC 61755-3-32:2015 defines certain dimensional limits of an angled PC rectangular thermoset (TS) ferrule optical interface in order to meet specific requirements for fibre-to-fibre interconnection. Ferrules made from the material specified in this standard are suitable for use in categories C, U, E, and O as defined in IEC 61753-1. Ferrule interface dimensions and features are contained in the IEC 61754 series, which deals with fibre optic connector interfaces.  
Keywords: dimensional limits of an angled PC rectangular thermoset (TS) ferrule optical interface

Lichtwellenleiter - Verbindungselemente und passive Bauteile - Teil 3-32: Optische Schnittstelle rechteckige duroplastische Epoxid-Ferrule 8 Grad abgewinkelt physikalischer Kontakt für Einmodenfasern

Dispositifs d’interconnexion et composants passifs à fibres optiques - Interfaces optiques de connecteurs - Partie 3-32: Paramètres de connecteurs pour fibres unimodales à dispersion non décalée, en contact physique - Férules rectangulaires avec angle en époxy thermodurcissable

L'IEC 61755-3-32:2015 définit un certain nombre de limites dimensionnelles des interfaces optiques à férules rectangulaires en époxy thermodurcissable (TS), PC avec angle afin de satisfaire aux exigences particulières d'une interconnexion fibre à fibre. Les férules réalisées dans le matériau spécifié dans la présente norme sont adaptées à une utilisation dans les catégories C, U, E et O définies dans l'IEC 61753-1. Les dimensions et les caractéristiques des interfaces des férules sont contenues dans la série IEC 61754 qui traite des interfaces de connecteurs pour fibres optiques.
Mots clés: limites dimensionnelles des interfaces optiques à férules rectangulaires en époxy thermodurcissable (TS)

Optični spojni elementi in pasivne komponente - Optični vmesniki optičnih konektorjev - 3-32. del: Optični vmesnik, PC pod kotom 8 stopinj, pravokotna tulka iz toplotno utrjene epoksidne smole, enorodovna optična vlakna

Ta del standarda IEC 61755 določa nekatere omejitve glede mer optičnega vmesnika PC pod kotom s toplotno utrjeno pravokotno tulko za namen izpolnjevanja določenih zahtev za spajanje vlaken. Tulke, izdelane iz materialov, ki so določeni v tem standardu, so primerne za uporabo v kategorijah C, U, E in O, kot je opredeljeno v standardu IEC 61753-1.
Mere in značilnosti vmesnika tulke so vključene v serijo IEC 61754, ki obravnava vmesnike optičnih konektorjev.

General Information

Status
Published
Publication Date
21-Mar-2016
Technical Committee
MOC - Mobile Communications
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
16-Mar-2016
Due Date
21-May-2016
Completion Date
22-Mar-2016

Overview

EN 61755-3-32:2016 (IEC 61755-3-32:2015) specifies dimensional limits of an angled PC rectangular thermoset (TS) ferrule optical interface for non-dispersion-shifted single‑mode fibres. The standard defines interface parameters for an 8° angled physical‑contact (PC) thermoset epoxy rectangular ferrule used in multi‑fibre connector assemblies. Ferrules made to this standard are intended for use in performance categories C, U, E and O (IEC 61753‑1) and reference connector interface definitions contained in the IEC 61754 series.

Key Topics

  • Dimensional limits and interface parameters for angled PC thermoset epoxy rectangular ferrules (8°).
  • Geometric tolerances that control lateral, angular and longitudinal offsets between mated fibres.
  • End‑face geometry and physical contact requirements to ensure low loss and repeatable mating.
  • Alignment features (guide holes, alignment pin geometry) and deformation constants relevant to rectangular ferrules.
  • Performance analysis and assessment methods, including informative annexes on:
    • theoretical worst‑case connector attenuation yield,
    • minus‑coplanarity effects,
    • minimum normal force required to achieve reliable physical contact.
  • Normative references to fibre product specs and test procedures (e.g., IEC 60793‑2‑50, IEC 61300 series) that are indispensable for correct application.

Applications

EN 61755-3-32 is practical for:

  • Connector and ferrule manufacturers designing thermoset epoxy rectangular ferrules for multi‑fibre connectors (MT/MPO families referenced via IEC 61754).
  • Component suppliers and quality engineers developing production tolerances, inspection criteria and end‑face polishing processes.
  • Test laboratories performing connector dimensional and optical performance verification (alignment, coplanarity, contact force).
  • Systems integrators and procurement teams specifying connector components for telecom, datacom, FTTx and high‑density data centre cabling where single‑mode angled PC interfaces are used.

Who Should Use This Standard

  • Optical connector designers and mechanical engineers
  • Manufacturing process and quality control teams
  • Certification bodies and test laboratories
  • Network architects specifying connector interfaces for single‑mode systems

Related Standards

  • IEC/EN 61754 series - fibre optic connector interfaces (MT, MPO families)
  • IEC 61755‑1 - general optical interface guidance for single‑mode non‑dispersion shifted fibres
  • IEC 61753‑1 - equipment performance categories (C, U, E, O)
  • IEC 60793‑2‑50 and IEC 61300 series - fibre product specifications and test methods

EN 61755-3-32:2016 (CLC/CENELEC adoption of IEC 61755-3-32) is the authoritative source for dimensional and interface parameters of angled PC rectangular thermoset ferrules, helping ensure reliable, low‑loss single‑mode fibre interconnections.

Standard

SIST EN 61755-3-32:2016 - BARVE

English language
22 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 61755-3-32:2016 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Fibre optic interconnecting devices and passive components - Fibre optic connector optical interfaces - Part 3-32: Optical interface, 8 degrees angled PC, thermoset epoxy rectangular ferrule, single mode fibres". This standard covers: IEC 61755-3-32:2015 defines certain dimensional limits of an angled PC rectangular thermoset (TS) ferrule optical interface in order to meet specific requirements for fibre-to-fibre interconnection. Ferrules made from the material specified in this standard are suitable for use in categories C, U, E, and O as defined in IEC 61753-1. Ferrule interface dimensions and features are contained in the IEC 61754 series, which deals with fibre optic connector interfaces. Keywords: dimensional limits of an angled PC rectangular thermoset (TS) ferrule optical interface

IEC 61755-3-32:2015 defines certain dimensional limits of an angled PC rectangular thermoset (TS) ferrule optical interface in order to meet specific requirements for fibre-to-fibre interconnection. Ferrules made from the material specified in this standard are suitable for use in categories C, U, E, and O as defined in IEC 61753-1. Ferrule interface dimensions and features are contained in the IEC 61754 series, which deals with fibre optic connector interfaces. Keywords: dimensional limits of an angled PC rectangular thermoset (TS) ferrule optical interface

SIST EN 61755-3-32:2016 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 61755-3-32:2016 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-maj-2016
2SWLþQLVSRMQLHOHPHQWLLQSDVLYQHNRPSRQHQWH2SWLþQLYPHVQLNLRSWLþQLK
NRQHNWRUMHYGHO2SWLþQLYPHVQLN3&SRGNRWRPVWRSLQMSUDYRNRWQDWXOND
L]WRSORWQRXWUMHQHHSRNVLGQHVPROHHQRURGRYQDRSWLþQDYODNQD
Fibre optic interconnecting devices and passive components - Fibre optic connector
optical interfaces - Part 3-32: Optical interface, 8 degrees angled PC, thermoset epoxy
rectangular ferrule, single mode fibres
Ta slovenski standard je istoveten z: EN 61755-3-32:2016
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 61755-3-32

NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2016
ICS 33.180.20
English Version
Fibre optic interconnecting devices and passive components -
Connector optical interfaces - Part 3-32: Connector parameters
of non-dispersion shifted single mode physically contacting fibres
- Angled thermoset epoxy rectangular ferrules
(IEC 61755-3-32:2015)
Dispositifs d'interconnexion et composants passifs à fibres Lichtwellenleiter - Verbindungselemente und passive
optiques - Interfaces optiques de connecteurs - Partie 3-32: Bauteile - Teil 3-32: Optische Schnittstelle rechteckige
Paramètres de connecteurs pour fibres unimodales à duroplastische Epoxid-Ferrule 8 Grad abgewinkelt
dispersion non décalée, en contact physique - Férules physikalischer Kontakt für Einmodenfasern
rectangulaires avec angle en époxy thermodurcissable (IEC 61755-3-32:2015)
(IEC 61755-3-32:2015)
This European Standard was approved by CENELEC on 2015-07-17. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61755-3-32:2016 E
European foreword
The text of document 86B/3889/FDIS, future edition 1 of IEC 61755-3-32, prepared by SC 86B "Fibre
optic interconnecting devices and passive components" of IEC/TC 86 "Fibre optics" was submitted to
the IEC-CENELEC parallel vote and approved by CENELEC as EN 61755-3-32:2016.

The following dates are fixed:
• latest date by which the document has to be (dop) 2016-09-11
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2019-03-11
• latest date by which the national
standards conflicting with the
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61755-3-32:2015 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:

IEC 61753-1 NOTE Harmonized as EN 61753-1.
IEC 61754-10:2005 NOTE Harmonized as EN 61754-10:2005.
IEC 61755-2-1 NOTE Harmonized as EN 61755-2-1.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Publication Year Title EN/HD Year

IEC 60793-2-50 -  Optical fibres - EN 60793-2-50 -
Part 2-50: Product specifications -
Sectional specification for class B single-
mode fibres
IEC 61300-3-30 -  Fibre optic interconnecting devices and EN 61300-3-30 -
passive components - Basic test and
measurement procedures -
Part 3-30: Examinations and
measurements - Polish angle and fibre
position on single ferrule multifibre
connectors
IEC 61300-3-52 -  Fibre optic interconnecting devices and EN 61300-3-52 -
passive components - Basic test and
measurement procedures -
Part 3-52: Examinations and
measurements - Guide hole and alignment
pin deformation constant, CD for 8 degree
angled PC rectangular ferrule, single mode
fibres
IEC 61754 Series Fibre optic interconnecting devices and EN 61754 Series
passive components - Fibre optic
connector interfaces
IEC 61754-5 2005 Fibre optic connector interfaces - EN 61754-5 2005
Part 5: Type MT connector family
IEC 61754-7 2008 Fibre optic interconnecting devices and EN 61754-7 2008
passive components - Fibre optic
connector interfaces -
Part 7: Type MPO connector family
IEC 61754-7-1 2014 Fibre optic interconnecting devices and EN 61754-7-1 2014
passive components - Fibre optic
connector interfaces -
Part 7-1: Type MPO connector family -
One fibre row
IEC 61755-1 -  Fibre optic connector optical interfaces - EN 61755-1 -
Part 1: Optical interfaces for single mode
non-dispersion shifted fibres - General and
guidance
IEC 61755-3-32 ®
Edition 1.0 2015-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Fibre optic interconnecting devices and passive components – Connector

optical interfaces –
Part 3-32: Connector parameters of non-dispersion shifted single mode

physically contacting fibres – Angled thermoset epoxy rectangular ferrules

Dispositifs d’interconnexion et composants passifs à fibres optiques –

Interfaces optiques de connecteurs –

Partie 3-32: Paramètres de connecteurs pour fibres unimodales à dispersion

non décalée, en contact physique – Férules rectangulaires avec angle en

époxy thermodurcissable
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.180.20 ISBN 978-2-8322-2713-8

– 2 – IEC 61755-3-32:2015 © IEC 2015
CONTENTS
FOREWORD . 3
1 Scope . 5
2 Normative references. 5
3 Description . 6
4 Interface parameters . 6
Annex A (informative) Theoretical worst-case connector attenuation yield percentage . 12
Annex B (informative) Minus coplanarity . 14
Annex C (informative) Minimum normal force required to achieve physical contact . 15
Bibliography . 19

Figure 1 – Fibre numbering conventions . 7
Figure 2 – Interface dimensions related to lateral and angular offset . 7
Figure 3 – Alignment pin geometry . 8
Figure 4 – Interface dimensions related to longitudinal offset . 9
Figure A.1 – Monte Carlo simulation of Grade C performance for 12-fibre connectors . 12
Figure B.1 – Illustration of fibre line and minus coplanarity parameters . 14
Figure C.1 – Geometry limit (GL), needed to mate 12 fibres, as a function of absolute
X-angle, SX for different magnitudes of minus coplanarity and flat fibre tips . 16
Figure C.2 – Geometry limit (GL), needed to mate 12 fibres, as a function of absolute
X-angle, SX for different magnitudes of minus coplanarity and 1 mm fibre tips . 16

Table 1 – Optical interface variant information . 7
Table 2 – Optical interface dimensions related to lateral and angular offset for optical
interface variant 2112 . 10
Table 3 – Optical interface end face geometry dimensions related to physical contact
for optical interface variant 2112 . 11
Table A.1 – Grade C single channel vs. multi-fibre connector performance . 13
Table C.1 – Parameter constants for 4-fibre optical interface variant K2 . 18
Table C.2 – Parameter constants for 8-fibre optical interface variant K3 . 18
Table C.3 – Parameter constants for 12-fibre optical interface variant K4 . 18

IEC 61755-3-32:2015 © IEC 2015 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
CONNECTOR OPTICAL INTERFACES –

Part 3-32: Connector parameters of non-dispersion
shifted single mode physically contacting fibres –
Angled thermoset epoxy rectangular ferrules

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61755-3-32 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
This first edition cancels and replaces IEC PAS 61755-3-32 published in 2007. This edition
constitutes a technical revision.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/3889/FDIS 86B/3915/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

– 4 – IEC 61755-3-32:2015 © IEC 2015
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61755 series, under the general title Fibre optic interconnecting
devices and passive components – Connector optical interfaces, can be found on the IEC
website.
Future standards in this series will carry the new general title as cited above. Titles of existing
standards in this series will be updated at the time of the next edition.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
IEC 61755-3-32:2015 © IEC 2015 – 5 –
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
CONNECTOR OPTICAL INTERFACES –

Part 3-32: Connector parameters of non-dispersion
shifted single mode physically contacting fibres –
Angled thermoset epoxy rectangular ferrules

1 Scope
This part of IEC 61755 defines certain dimensional limits of an angled PC rectangular
thermoset (TS) ferrule optical interface in order to meet specific requirements for fibre-to-fibre
interconnection. Ferrules made from the material specified in this standard are suitable for
use in categories C, U, E, and O as defined in IEC 61753-1.
Ferrule interface dimensions and features are contained in the IEC 61754 series, which deals
with fibre optic connector interfaces.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60793-2-50, Optical fibres – Part 2-50: Product specifications – Sectional specification for
class B single-mode fibres
IEC 61300-3-30, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-30: Examinations and measurements – Polish angle and
fibre position on single ferrule multifibre connectors
IEC 61300-3-52, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-52: Examinations and measurements – Guide hole and
alignment pin deformation constant, C for 8 degree angled PC rectangular ferrule, single
D
mode fibres
IEC 61754 (all parts), Fibre optic interconnection devices and passive components – Fibre
optic connector interfaces
IEC 61754-5:2005, Fibre optic connector interfaces – Part 5: Type MT connector family
IEC 61754-7:2008, Fibre optic interconnecting devices and passive components – Fibre optic
connector interfaces – Part 7: Type MPO connector family
IEC 61754-7-1:2014, Fibre optic interconnecting devices and passive
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...