SIST EN ISO 2556:2001
(Main)Plastics - Determination of the gas transmission rate of films and thin sheets under atmospheric pressure - Manometric method (ISO 2556:1974)
- Abstract
Specification of the methodand of two types of suitable test apparatus. The plastic test specimen separates two chambers, the one contains the test gas at atmospheric pressure, the other of known initial volume has the air pumped out until the pressure is practically zero. The quantity of gas which passes through the specimen from one chamber to the other is determined as a function of time by measuring the increase in pressure occuring in the second chamber by means of a manometer.
- Status
- Published
- Publication Date
- 31-May-2001
- Technical Committee
- IPMA - Polimer materials and products
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Jun-2001
- Due Date
- 01-Jun-2001
- Completion Date
- 01-Jun-2001
SIST EN ISO 2556:2001 is a SIST standard for determining the gas transmission rate of plastics films and thin sheets under atmospheric pressure. It specifies a manometric method and two suitable apparatus arrangements, using air or another test gas, for laboratories and users who need barrier-property data on film and sheet materials.
What does SIST EN ISO 2556:2001 specify?
SIST EN ISO 2556:2001 specifies a test method for measuring how much gas passes through plastics films and thin sheets when one side of the specimen is exposed to gas at atmospheric pressure and the other side is evacuated. The result is the gas transmission rate, reported in relation to area, time, temperature and pressure difference.
The document is organized into clauses 1 to 9:
- scope and field of application
- reference
- definition
- principle
- apparatus and materials
- test specimens
- procedure
- expression of results
- test report
The method applies to air or other test gases. It gives the measurement range as 1 to 20 000 cm3/m2.d.atm, so it covers both low- and high-transmission materials.
What are the key requirements of SIST EN ISO 2556:2001?
Clause 4 - how the measurement works
SIST EN ISO 2556:2001 uses a specimen that separates two chambers. Chamber 1 holds the test gas at atmospheric pressure, while chamber 2 is evacuated and then sealed; the gas transmission rate is obtained from the pressure rise in chamber 2 over time.
In practice, this means the operator does not collect permeated gas directly. Instead, the test depends on accurate pressure measurement and stable sealing, so leaks or poor clamping will distort the result.
Clause 5 - apparatus and test conditions
SIST EN ISO 2556:2001 requires the apparatus to be installed in an enclosure held at constant temperature within +/- 2 C during the test. It also describes two forms of metal cell: one using filter paper and a perforated disc, and one using a sintered disc of glass or bronze.
This matters because the support under the specimen must let gas pass while keeping the film flat. The vacuum pump must reduce the lower chamber pressure to at most 13 Pa, and the pressure measuring device must read that pressure with an accuracy of 6 Pa or better.
Clauses 6 and 7 - specimens and procedure
SIST EN ISO 2556:2001 requires specimens representative of the batch and free from creases, thin spots, porosity, holes and similar visible defects. At least three specimens are tested, and hygroscopic materials are conditioned in the selected atmosphere, preferably one of the atmospheres of ISO/R 291.
In testing, the lower chamber is evacuated, the apparatus is checked for airtightness, and the mercury level in the capillary is followed as a function of time. The standard says to continue until the rise becomes steady or changes only very slowly, because only the steady part is used for the calculation.
Clause 8 - calculation and correction
SIST EN ISO 2556:2001 calculates the transmission rate from the measured pressure-rise slope, the specimen area, the chamber volume, the capillary dimensions and the barometric pressure. If the apparatus is used without mercury overflowing, a correction coefficient is applied.
For the reader, this means the apparatus dimensions are not just setup details - they enter the final result. Accurate calibration of the chamber volume and careful reading of the capillary height are necessary for reliable values.
Clause 9 - reporting
SIST EN ISO 2556:2001 requires the test report to state the sample description and mean thickness, any conditioning, the number of specimens, the apparatus used, the test gas and its relative humidity if applicable, the test temperature, and the transmission rate for each specimen with the mean value.
What terms does SIST EN ISO 2556:2001 define?
- Gas transmission rate - the volume of gas passing through unit area in unit time under unit pressure difference at constant temperature, expressed at standard temperature and pressure.
- Test specimen - the film or thin sheet piece taken from the batch and mounted in the cell for measurement.
- Chamber 1 - the upper chamber that contains the test gas at atmospheric pressure.
- Chamber 2 - the evacuated lower chamber where the pressure rise is measured.
- Correction coefficient c - the factor used when the apparatus is operated without overflowing mercury, to correct the calculated result.
- Initial volume of chamber 2 (V) - the fixed volume of the lower chamber from the specimen face to the capillary zero level.
Who uses SIST EN ISO 2556:2001?
SIST EN ISO 2556:2001 is used by plastics laboratories, film and sheet manufacturers, packaging technical teams, and quality control personnel who need barrier data for product specification or incoming inspection. It is also relevant to testing laboratories that compare materials using a common manometric method.
Buyers and engineers use it when they need to check whether a film or thin sheet has the gas transmission performance expected for a given application. The standard is especially relevant where atmospheric-pressure permeability data are part of material selection or acceptance testing.
Which standards are used with SIST EN ISO 2556:2001?
SIST EN ISO 2556:2001 cites ISO/R 291, Plastics - Standard atmospheres for conditioning and testing. That reference provides the conditioning and test atmospheres used when specimens, especially hygroscopic materials, need controlled preconditioning before measurement.
What does the SIST EN ISO 2556:2001 document contain?
SIST EN ISO 2556:2001 contains a worked measurement principle, apparatus descriptions, procedure steps, calculation guidance and reporting requirements. It includes two example apparatus drawings: one with mercury overflowing and one without overflowing.
The document also gives the calculation basis for the gas transmission rate, including the correction for apparatus geometry and the use of barometric pressure. Its figures show the cell, capillary, U-tube, mercury reservoir and specimen support arrangements, which are the parts the operator must assemble and monitor during the test.
Relations
- Refers
SIST EN ISO 291:2009 - Plastics - Standard atmospheres for conditioning and testing (ISO 291:2008) - Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard
DIN CERTCO
DIN Group product certification.

Smithers Quality Assessments
US management systems and product certification.
Sponsored listings
Frequently Asked Questions
SIST EN ISO 2556:2001 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Plastics - Determination of the gas transmission rate of films and thin sheets under atmospheric pressure - Manometric method (ISO 2556:1974)". This standard covers: Specification of the methodand of two types of suitable test apparatus. The plastic test specimen separates two chambers, the one contains the test gas at atmospheric pressure, the other of known initial volume has the air pumped out until the pressure is practically zero. The quantity of gas which passes through the specimen from one chamber to the other is determined as a function of time by measuring the increase in pressure occuring in the second chamber by means of a manometer.
Specification of the methodand of two types of suitable test apparatus. The plastic test specimen separates two chambers, the one contains the test gas at atmospheric pressure, the other of known initial volume has the air pumped out until the pressure is practically zero. The quantity of gas which passes through the specimen from one chamber to the other is determined as a function of time by measuring the increase in pressure occuring in the second chamber by means of a manometer.
SIST EN ISO 2556:2001 is classified under the following ICS (International Classification for Standards) categories: 83.140.10 - Films and sheets. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN ISO 2556:2001 has the following relationships with other standards: It is inter standard links to SIST EN ISO 291:2009. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN ISO 2556:2001 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Polimerni materiali - Filmi in folije - Ugotavljanje prepustnosti plinov pri atmosferskem tlaku - Manometrijska metoda (ISO 2556:1974)Kunststoffe - Bestimmung der Gasdurchlässigkeit von Folien und dünnen Tafeln unter atmosphärischem Druck -Druckmessgerät- Verfahren (ISO 2556:1974)Matieres plastiques - Détermination du coefficient de transmission d'un gaz par les feuilles et plaques minces, sous pression atmosphérique - Méthode manométrique (ISO 2556:1974)Plastics - Determination of the gas transmission rate of films and thin sheets under atmospheric pressure - Manometric method (ISO 2556:1974)83.140.10Filmi in folijeFilms and sheetsICS:Ta slovenski standard je istoveten z:EN ISO 2556:2000SIST EN ISO 2556:2001en01-junij-2001SIST EN ISO 2556:2001SLOVENSKI
STANDARD
INTERNATIONAL STANDARD. INTERNATIONAL ORGANIZATION FOR STANDARDIZATION l MEXAYHAPOAHAII OPTAHM3ALWI l-IO CTAHAAPTI13AL@iW-ORGANISATION INTERNATIONALE DE NORMALISATION Plastics - Determination of the gas transmission rate of films and thin sheets under atmospheric pressure - Manometric method Ma tieres plastiques - Determination du coefficient de transmission d’un gaz par fes feuilles et plaques minces, sous Pression a tmospherique - Mthode manometrique First edition - 1974-06-01 UDC 678.5/.8-416 : 620.165.29 Descriptors : plastics, sheets, thin films, diffusion, gas, determination, pressure test. Rd. No. ISO 2556-1974 (E) Price based on 6 pages SIST EN ISO 2556:2001
FOREWORD ISO (the international Organization for Standardization) is a worldwide federation of national Standards institutes (ISO Member Bodies). The work of developing International Standards is carried out through ISO Technical Committees. Every Member Body interested in a subject for which a Technical Committee has been set up has the right to be represented on that Committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. Draft International Standards adopted by the Technical Committees are circulated to the Member Bodies for approval before their acceptance as International Standards by the ISO Council. International Standard ISO 2556 was drawn up by Technical Committee ISO/TC 61, Plastics, and circulated to the Member Bodies in February 1972. lt has been approved by the Member Bodies of the following countries : Australia Austria Belgium Brazil Canada Czechoslovakia Egypt, Arab Rep. of France Germany The Member Body o on technical grounds f the following country expr India I reland Israel Japan New Zealand Poland Portugal Romania South Africa, Rep. of Netherlands Spain Sweden Switzerland Thailand Turkey United Kingdom U.S.A. U.S.S.R. disapproval of the document 0 International Organkation for Standardkation, 1974 l Printed in Switzerland SIST EN ISO 2556:2001
INTERNATIONAL STANDARD ISO 2556-1974 (E) Plastics - Determination of the gas transmission rate of films and thin sheets under atmospheric pressure - Manometric method 1 SCOPE AND FIELD OF APPLICATION This International Standard specifies a method for the determination of the gas transmission rate of plastics films and thin sheets. The limits of the values which tan be measured are from 1 to 20 000 cm3/m2.d.atm. The method tan be used for measurements made either with air or with other test gases. 2 REFERENCE ISO/ R 29 1, Plastics - Standard a tmospheres for conditioning and testing. 3 DEFINITION gas transmission rate : The volume of gas which, under steady conditions, crosses unit area of the Sample in unit time under unit pressure differente and at constant temperature. This volume is expressed at Standard temperature and pressure. The rate depends on the thickness of the test specimen, and the reliability of the results depends on the evenness of the specimen thickness. The rate is usually expressed in cubic centimetres (at 0 “C under Standard atmospheric pressure per Square metre per 24 h under a pressure differente of 1 atm (cm3/m2.d.atm). NOTES 1 The SI unit of gas transmission rate is fm/Pa.s [ 1 fm (femtometre) = 10 -=15 m] 1 cm3/m2.d.atm = 0,114 3 fm/Pa.s and 1 fm/Pa.s = 8,752 cm3/m2.d.atm. 2 The Standard atmospheric pressure corresponds to the pressure of a mercury column 760 mm high : either 1 013 mbar or 101,3 kPa. 4 PRINCIPLE The plastic test specimen separates two chambers num- bered 1 and 2. Chamber 1 contains the test gas at atmos- pheric pressure. Chamber 2, of know initial volume, has the air pumped out until the pressure is practically Zero, then is hermetically sealed. The quantity of gas which Passes through the specimen from chamber 1 to chamber 2 is determined as a function of time by measuring the increases of pressure occurring in chamber 2 by means of a manometer. The transmission rate is calculated from the values obtained, excluding the initial period during which the rate of passage of gas increases with time. 5 APPARATUS AND MATERIALS The apparatus which comprises the Parts described in 5.1 to 5.4, and of which suitable examples are shown in figures 1 and 2, must be placed in an enclosure with the temperature constant to within + 2 “C during the test. 5.1 Metal cell consisting of two detachable Parts, as follows : 1) an upper part forming the cylindrical chamber 1 to contain the test gas, provided with tubes for the entry and exit of the gas employed; 2) a lower part forming a plane and polished “test plate” of diameter 100 to 120 mm and having at its centre either a) a cavity of about 20 mm diameter containing a perforated disc and below this a small empty space so that the total depth of the cavity is 12 to 15 mm (see figure 1). In this type of apparatus a filter Paper must be interposed between the specimen and the test plate. The diameter of this filter Paper must be near, but not greater than, the internal diameter of the gasket; OL b) a cavity about 60 mm diameter and a few millimetres deep, filled with a sintered disc of glass or of bronze (see figure 2). The filter Paper indicated in a) or the sintered disc indicated in b) are to support the test specimen while at the same time allowing the passage of gas. In case b) the upper part of the sintered disc must be level with the test plate so that the specimen rests flat over its whole surface. The closed space below the test specimen forms chamber 2, and is attached to a capillary tube (5.2) forming the manometer and to a vacuum pump (5.5). 1 SIST EN ISO 2556:2001
ISO 2556-1974 (E) The two Parts of the cell are clamped together by means of an effective clamping device, a circular gasket of rubber being l.lsed to isolate the cell completely from the external atmosphere and to prevent the passage of gas from chamber 1 to chamber 2 other than through the test specimen. 5.5 Vacuum pump giving a pressure at the most equal to 13 Pa (0,13 mbar or 0,l mmHg) in the Iower chamber, and a gauge to measure this pressure with an accuracy of 6 Pa (0,06 bar or 0,05 mmHg) or better. 5.6 Mercury barometer. NOTE - lt is recommended that a check of the airtightness of the apparatus should be made by carrying out a blank test in accordance with the procedure of clause 7 but with the test specimen replaced by metal foil. 5.7 Thermometer which tan be read to 0,5 “C. 5.8 Mercury. The level of the mercury in the capillary must remain practically unchanged during a period of the same Order as that needed for the proposed measurements. 5.9 Test gases and drying column if required. 5.2 Calibrated capillary tube about 1,5 to 2 mm internal diameter and 200 to 400 mm in length, connected to the base of the metal cell. A scale graduated to 0,5 mm indicates the mercury level in the capillary tube. 6 TEST SPECIMENS The specimens shall be representative of the batch of sheet or film for test and free from marks or visible defects (creases, thin spots, porosity, holes, etc.). 5.3 U-tube about 5 mm diameter, connected to bottom of the capillary tube as shown i n figures 1 a nd 2 the One arm of the tube is closed. The other arm is joined to a vacuum stopcock (which tan be connected to a vacuum pump) and to a mercury reservoir (5.4) into which the mercury tan be poured by overflowing. 5.4 Mercury reservoir fixed to the arm of the U-tube connected to the vacuum stopcock. This fixing tan be done by method 1) or 2) described below. 1) Fixing directly to the U-tube arm (see figure 1). This type of apparatus tan be arranged to function either with or without overflowing of mercury during the test. a) In the case of apparatus with overflowing, the U-tube is filled with mercury up to the overflowing level which also corresponds to the scale zero (as shown in figure 1). During the test the mercury level is maintained constant by overflowing. Nevertheless the regulation sf the level is not altogether perfett since the overflowing occurs jerkily. It may ther efore be prefera the manner described in b). ble to use the apparatus in b) In the case of apparatus without overflowing, the U-tube is only filled to a Point appreciably below the overflowing level, so that the whole test is carried out without overflowing. In this case the scale zero is below the overflowing level and in the calculation a correction is essential (see 8.2). 2) The reservoir may be fixed to a greatly enlarged Portion of this arm of the tube (about 20 mm diameter) and there is no overflowing during the test (see figure 2). They shall be in the form of discs with a diameter, depending on the apparatus used, large enough to overlap the joint between the two portions of the metal cell. This diameter is usually about 80 mm. At least three specimens must be tested. Spetimens of
...