Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1: Cords with IEC 60793-2-50 singlemode category B1.1 and B1.3 fibre for category C

This standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements that an assembled singlemode patch cord with cylindrical ferruled connectors shall meet in order for it to be categorised as an EN standard product. Since different variants and grades of performance are permitted, product marking details are given in 3.4 and Clause 4.

Steckverbindersätze und Verbindungsbauelemente für Lichtwellenleiter-Datenübertragungssysteme - Produktnormen -- Teil 14-1: Verbindungskabel für Einmodenfasern der Kategorien B1.1 und B1.3 nach EN 60793 2 50 für die Kategorie C

Jeux de connecteurs et composants d’interconnexion à utiliser dans les systèmes de communication par fibres optiques - Spécifications de produits - Partie 14-1: Cordons avec fibre unimodale de catégories B1.1 et B1.3 conforme à l’IEC 60793-2-50 pour la catégorie C

Konektorski sestavi in povezovalne komponente za optične komunikacijske sisteme - Specifikacija izdelka - 14-1. del: Vrvice z enorodnim optičnim vlaknom po EN 60793-2-50 kategorij B1.1 in B1.3 za kategorijo C

Ta standard vsebuje začetne zahteve za dimenzije, optične in mehanske zahteve ter zahteve za okoljsko učinkovitost, ki jim mora ustrezati sestavljena enorodna priključna vrvica s cilindričnimi konektorji s spojko, da bi bila opredeljena kot izdelek standarda EN. Ker so dovoljene različice in različne stopnje zmogljivosti, so podrobnosti o označevanju proizvoda navedene v 3.4 in v točki 4.

General Information

Status
Withdrawn
Publication Date
23-Jun-2011
Withdrawal Date
16-Jun-2019
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
13-Jun-2019
Due Date
06-Jul-2019
Completion Date
17-Jun-2019

Relations

Buy Standard

Standard
EN 50377-14-1:2011
English language
18 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50377-14-1:2011
01-september-2011
.RQHNWRUVNLVHVWDYLLQSRYH]RYDOQHNRPSRQHQWH]DRSWLþQHNRPXQLNDFLMVNH
VLVWHPH6SHFLILNDFLMDL]GHONDGHO9UYLFH]HQRURGQLPRSWLþQLPYODNQRPSR
(1NDWHJRULM%LQ%]DNDWHJRULMR&
Connector sets and interconnect components to be used in optical fibre communication
systems - Product specifications - Part 14-1: Cords with IEC 60793-2-50 singlemode
category B1.1 and B1.3 fibre for category C
Steckverbindersätze und Verbindungsbauelemente für Lichtwellenleiter-
Datenübertragungssysteme - Produktnormen -- Teil 14-1: Verbindungskabel für
Einmodenfasern der Kategorien B1.1 und B1.3 nach EN 60793 2 50 für die Kategorie C
Ta slovenski standard je istoveten z: EN 50377-14-1:2011
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
SIST EN 50377-14-1:2011 en,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 50377-14-1:2011

---------------------- Page: 2 ----------------------

SIST EN 50377-14-1:2011

EUROPEAN STANDARD
EN 50377-14-1

NORME EUROPÉENNE
June 2011
EUROPÄISCHE NORM

ICS 33.180.20


English version


Connector sets and interconnect components to be used in optical fibre
communication systems -
Product specifications -
Part 14-1: Cords with IEC 60793-2-50 singlemode category B1.1 and B1.3
fibre for category C



 Steckverbindersätze und
Verbindungsbauelemente für
Lichtwellenleiter-
Datenübertragungssysteme -
Produktnormen -
Teil 14-1: Verbindungskabel für
Einmodenfasern der Kategorien B1.1 und
B1.3 nach EN 60793 2 50 für die
Kategorie C


This European Standard was approved by CENELEC on 2011-05-02. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50377-14-1:2011 E

---------------------- Page: 3 ----------------------

SIST EN 50377-14-1:2011
EN 50377-14-1:2011 – 2 –
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic
interconnect, passive and connectorised components.
The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as
EN 50377-14-1 on 2011-05-02.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights.
The following dates were fixed:
– latest date by which the EN has to be implemented

at national level by publication of an identical

national standard or by endorsement
(dop) 2012-05-02

– latest date by which the national standards conflicting

with the EN have to be withdrawn
(dow) 2014-05-02
This document includes the performance of the patch cord, as well as latest attenuation and return loss
grades as specified in IEC.
__________

---------------------- Page: 4 ----------------------

SIST EN 50377-14-1:2011
– 3 – EN 50377-14-1:2011
Connector sets and interconnect components to be used in optical fibre communication systems –
Product specifications
Part 14-1: Cords with IEC 60793-2-50 singlemode category B1.1 and B1.3 fibre for category C
Description Performance
Fibre category: EN 60793-2-50 Application: For use in EN category C
Types B1.1 and B1.3 (controlled environment)
Cable type: EN 60794-2-50 Attenuation grades: B: ≤ 0,12 dB mean
Type simplex cables (random mate)
≤ 0,25 dB for ≥ 97 %
of measurements

C: ≤ 0,25 dB mean
≤ 0,50 dB for ≥ 97 %
of measurements
 Return loss grade: 1: ≥ 60 dB
(random mate) 2: ≥ 45 dB
Related documents:
EN 50377 series Connector sets and interconnect components to be used in optical fibre
communication systems – Product specifications
EN 60793-2-50 Optical fibres – Part 2-50: Product specifications – Sectional specification for
class B single-mode fibres (IEC 60793-2-50)
EN 60794-2-50 Optical fibre cables – Part 2-50: Indoor cables – Family specification for simplex
and duplex cables for use in terminated cable assemblies (IEC 60794-2-50)
EN 61300 series Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures (IEC 61300 series)
EN 61753-1 Fibre optic interconnecting devices and passive components performance standard –
Part 1: General and guidance for performance standards (IEC 61753-1)
ETSI TS 100 671 Transmission and Multiplexing (TM); Passive optical components; Optical fibre
connectors for single mode optical fibre communication systems; Common
requirements and conformance testing
Outline and maximum dimensions:
Length

---------------------- Page: 5 ----------------------

SIST EN 50377-14-1:2011
EN 50377-14-1:2011 – 4 –
Contents
1 Scope . 5
1.1 Product definition . 5
1.2 Intermateability of the plugs . 5
1.3 Operating environment . 5
1.4 Reliability . 5
1.5 Quality assurance . 5
2 Normative references . 6
3 Description . 6
3.1 Plug . 7
3.2 Cable . 7
3.3 Materials . 7
3.4 Marking . 7
4 Variants . 8
5 Dimensional requirements . 9
5.1 Outline dimensions . 9
6 Tests . 9
6.1 Sample size . 9
6.2 Test and measurement methods . 9
6.3 Test sequence . 9
6.4 Pass/fail criteria . 9
7 Test report . 9
8 Product qualification requirements . 10
8.1 Dimensional and marking requirements. 10
8.2 Optical performance requirements . 10
8.3 Mechanical performance requirements . 12
8.4 Environmental performance requirements . 14
Annex A (informative) Reference connector details . 15
Annex B (normative) Tests, sample size and product sourcing requirements . 16
Annex C (normative) Cable bend (coiling) test procedure . 17
Bibliography . 18
Figures
Figure 1 – Length of patch cord . 9
Figure C.1 – Cable bend (coiling) test set-up . 17
Tables
Table 1 – Ensured level of random attenuation . 5
Table 2 – Connector references . 7
Table 3 – Optical performance requirements . 11
Table 4 – Mechanical performance requirements . 12
Table 5 – Environmental performance requirements . 14
Table B.1 – Test, sample size and sourcing . 16

---------------------- Page: 6 ----------------------

SIST EN 50377-14-1:2011
– 5 – EN 50377-14-1:2011
1 Scope
1.1 Product definition
This standard contains the initial, start of life dimensional, optical, mechanical and environmental
performance requirements that an assembled singlemode patch cord with cylindrical ferruled connectors
shall meet in order for it to be categorised as an EN standard product.
Since different variants and grades of performance are permitted, product marking details are given in 3.4
and Clause 4.
1.2 Intermateability of the plugs
Although all products conforming to the requirements of this standard will intermate, the resulting level of
random attenuation performance will only be ensured in accordance with Table 1. The intention is that this
will be true irrespective of the manufacturing source(s) of the product.
When intermating plug variants having different attenuation grades as specified in EN 61755-1, the resulting
level of attenuation cannot be assured to be any better than the worst attenuation grade.
The intermating of a grade C plug with a grade B plug will result in a grade C level of random attenuation
performance.
Table 1 – Ensured level of random attenuation
Plug variant / Plug 2
Attenuation grade
C B
C C C
Plug 1
B C B

1.3 Operating environment
The tests selected combined with the severities and durations are representative of an EN 61753-1
category C environment.
1.4 Reliability
Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with
this standard does not guarantee the reliability of the product. This should be predicted using a recognised
reliability assessment programme.
1.5 Quality assurance
Compliance with this standard does not guarantee the manufacturing consistency of the product. This should
be maintained using a recognised quality assurance programme.

---------------------- Page: 7 ----------------------

SIST EN 50377-14-1:2011
EN 50377-14-1:2011 – 6 –
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 50377 series Connector sets and interconnect components to be used in optical fibre communication
systems – Product specifications
EN 60793-2-50 Optical fibres – Part 2-50: Product specifications – Sectional specification for class B
single-mode fibres (IEC 60793-2-50)
EN 60794-2-50 Optical fibre cables – Part 2-50: Indoor cables – Family specification for simplex and
duplex cables for use in terminated cable assemblies (IEC 60794-2-50)
EN 61300-2-4 Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre/cable retention (IEC 61300-2-4)
EN 61300-2-22 Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-22: Tests – Change of temperature (IEC 61300-2-22)
EN 61300-2-42 Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-42: Tests – Static side load for connectors
(IEC 61300-2-42)
EN 61300-2-44 Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-44: Tests – Flexing of the strain relief of fibre optic
devices (IEC 61300-2-44)
EN 61300-3-3 Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-3: Examinations and measurements –
Active monitoring of changes in attenuation and return loss (IEC 61300-3-3)
EN 61300-3-6 Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-6: Examinations and measurements –
Return loss (IEC 61300-3-6)
EN 61300-3-22 Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-22: Examinations and measurements –
Ferrule compression force (IEC 61300-3-22)
EN 61300-3-28 Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-28: Examinations and measurements –
Transient loss (IEC 61300-3-28)
EN 61300-3-34 Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-34: Examinations and measurements –
Attenuation of random mated connectors (IEC 61300-3-34)
EN 61753-1 Fibre optic interconnecting devices and passive components performance standard –
Part 1: General and guidance for performance standards (IEC 61753-1)
EN 61755-1 Fibre optic connector optical interfaces – Part 1: Optical interfaces for single mode
non-dispersion shifted fibres – General and guidance (IEC 61755-1)
3 Description
This document applies to both patch cords and work area cords.
A patch cord is defined as a short length of cable with connector plugs assembled at both cable ends. Typical
length (but not limited to) is 1 m to 10 m, measured from tip to tip at the extremes. Patch cords are installed
in mechanically protected locations (inside cabinets, distribution frames and enclosures).

---------------------- Page: 8 ----------------------

SIST EN 50377-14-1:2011
– 7 – EN 50377-14-1:2011
Work area cords are typically more ruggedized (larger diameter) and used in mechanically less protected
locations.
For the purpose of this document, both patch cords and work area cords are called patch cords.
3.1 Plug
The plug features a cylindrical ferrule. It has a single male key that is used to limit and may be used
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.