Radio-frequency connectors - Part 47: Sectional specification - Radio-frequency coaxial connectors with clamp coupling, typically for use in 75 Ω cable networks (type F-Quick) (IEC 61169-47:2012)

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with clamp coupling, typically for use in 75 O cable networks (type F-Quick). It describes the interface dimensions with gauging information, electrical and mechanical performance including the mandatory tests selected from IEC 61169-1:1992, applicable to all DS relating to type F-Quick connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements.

Hochfrequenzsteckverbinder – Teil 47: Rahmenspezifikation - Koaxiale Hochfrequenzsteckverbinder mit Klemmkupplung, vorzugsweise für den Einsatz in 75-Ω-Kabelnetzen (Typ F-Quick) (IEC 61169-47:2012)

Connecteurs pour fréquences radioélectriques - Partie 47: Spécification intermédiaire relatives aux connecteurs coaxiaux pour fréquences radioélectriques avec couplage par bride, spécifiquement utilisés dans les réseaux câblés 75 Ω (type F-Quick) (CEI 61169-47:2012)

Radiofrekvenčni konektorji - 47. del: Področna specifikacija - Radiofrekvenčni koaksialni konektorji z zaskočnim spajanjem, tipični za uporabo v 75-ohmskih kabelskih omrežjih (vrste F-Quick) (IEC 61169-47:2012)

Ta del standarda IEC 61169, ki je področna specifikacija (SS), podaja informacije in določa pravila za pripravo podrobnih specifikacij (DS) za radiofrekvenčne koaksialne konektorje z zaskočnim spajanjem, običajno za uporabo v 75-ohmskih kabelskih omrežjih (vrste F-Quick). Dimenzije vmesnikov opisuje z merjenjem informacij, električne in mehanske zmogljivosti, skupaj z obveznimi preskusi, izbranimi iz standarda IEC 61169-1:1992, ki se uporabljajo za vse podrobne specifikacije v zvezi s konektorji vrste F-Quick. Ta specifikacija določa priporočene lastnosti, ki jih je treba upoštevati pri sestavljanju podrobnih specifikacij ter zajema urnike preskusov in zahteve za pregled.

General Information

Status
Withdrawn
Publication Date
08-Jan-2013
Withdrawal Date
19-Aug-2018
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
09-Aug-2018
Due Date
01-Sep-2018
Completion Date
20-Aug-2018

Relations

Buy Standard

Standard
EN 61169-47:2013
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61169-47:2013
01-februar-2013
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD5DGLRIUHNYHQþQL
NRDNVLDOQLNRQHNWRUML]]DVNRþQLPVSDMDQMHPWLSLþQL]DXSRUDERYRKPVNLK
NDEHOVNLKRPUHåMLK YUVWH)4XLFN  ,(&
5DGLRIUHTXHQF\FRQQHFWRUV3DUW6HFWLRQDOVSHFLILFDWLRQ5DGLRIUHTXHQF\FRD[LDO
FRQQHFWRUVZLWKFODPSFRXSOLQJW\SLFDOO\IRUXVHLQȍFDEOHQHWZRUNV W\SH)4XLFN
,(&
+RFKIUHTXHQ]VWHFNYHUELQGHU±7HLO5DKPHQVSH]LILNDWLRQ.RD[LDOH
+RFKIUHTXHQ]VWHFNYHUELQGHUPLW.OHPPNXSSOXQJYRU]XJVZHLVHIUGHQ(LQVDW]LQŸ
.DEHOQHW]HQ 7\S)4XLFN  ,(&
&RQQHFWHXUVSRXUIUpTXHQFHVUDGLRpOHFWULTXHV3DUWLH6SpFLILFDWLRQLQWHUPpGLDLUH
UHODWLYHVDX[FRQQHFWHXUVFRD[LDX[SRXUIUpTXHQFHVUDGLRpOHFWULTXHVDYHFFRXSODJHSDU
EULGHVSpFLILTXHPHQWXWLOLVpVGDQVOHVUpVHDX[FkEOpVŸ W\SH)4XLFN  &(,

Ta slovenski standard je istoveten z: EN 61169-47:2012
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
SIST EN 61169-47:2013 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61169-47:2013

---------------------- Page: 2 ----------------------

SIST EN 61169-47:2013

EUROPEAN STANDARD
EN 61169-47

NORME EUROPÉENNE
November 2012
EUROPÄISCHE NORM

ICS 33.120.30


English version


Radio-frequency connectors -
Part 47: Sectional specification for radio-frequency coaxial connectors
with clamp coupling, typically for use in 75 Ω cable networks (type F-
Quick)
(IEC 61169-47:2012)


Connecteurs pour fréquences Hochfrequenzsteckverbinder -
radioélectriques - Teil 47: Rahmenspezifikation -
Partie 47: Spécification intermédiaire Koaxiale Hochfrequenzsteckverbinder mit
relatives aux connecteurs coaxiaux pour Klemmkupplung, vorzugsweise für den
fréquences radioélectriques avec Einsatz in 75-Ω-Kabelnetzen (Typ F-
couplage par bride, spécifiquement Quick)
utilisés dans les réseaux câblés 75 Ω (IEC 61169-47:2012)
(type F-Quick)
(CEI 61169-47:2012)



This European Standard was approved by CENELEC on 2012-08-28. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-47:2012 E

---------------------- Page: 3 ----------------------

SIST EN 61169-47:2013
EN 61169-47:2012 - 2 -

Foreword
The text of document 46F/204/CDV, future edition 1 of IEC 61169-47, prepared by SC 46F, "R.F. and
microwave passive components", of IEC TC 46, "Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 61169-47:2012.

The following dates are fixed:
(dop) 2013-05-28
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2015-08-28
• latest date by which the national
standards conflicting with the
document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.

Endorsement notice
The text of the International Standard IEC 61169-47:2012 was approved by CENELEC as a European
Standard without any modification.

---------------------- Page: 4 ----------------------

SIST EN 61169-47:2013
- 3 - EN 61169-47:2012
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 61169-1 1992 Radio-frequency connectors - EN 61169-1 1994
+ A1 1996 Part 1: Generic specification - General + A1 1996
+ A2 1997 requirements and measuring methods + A2 1997


IEC 61169-24 2009 Radio-frequency connectors - EN 61169-24 2009
Part 24: Sectional specification - Radio
frequency coaxial connectors with screw
coupling, typically for use in 75 ohm cable
networks (type F)

---------------------- Page: 5 ----------------------

SIST EN 61169-47:2013

---------------------- Page: 6 ----------------------

SIST EN 61169-47:2013




IEC 61169-47

®


Edition 1.0 2012-07




INTERNATIONAL



STANDARD








colour

inside










Radio-frequency connectors –

Part 47: Sectional specification for radio-frequency coaxial connectors with

clamp coupling, typically for use in 75 Ω cable networks (type F-Quick)

























INTERNATIONAL

ELECTROTECHNICAL

COMMISSION

PRICE CODE
R


ICS 33.120.30 ISBN 978-2-83220-289-0



  Warning! Make sure that you obtained this publication from an authorized distributor.


® Registered trademark of the International Electrotechnical Commission

---------------------- Page: 7 ----------------------

SIST EN 61169-47:2013
– 2 – 61169-47 © IEC:2012(E)

CONTENTS

FOREWORD . 3
1 Scope . 5
2 Normative references . 5
3 Interface dimensions . 5
3.1 Dimensions . 5
3.1.1 Common dimensions . 5
3.1.2 Example of connector “F-Quick” type male plug with resilient outer
conductor sleeve (indoor) physical dimensions . 6
3.1.3 Example of connector “F-Quick” type male plug with slotted outer
conductor (indoor) physical dimensions . 7
3.1.4 Example of connector “F-Quick” type male plug with slotted outer
conductor and snap ring (indoor) physical dimensions . 7
3.2 Mechanical gauges . 8
4 Quality assessment procedures . 9
4.1 General . 9
4.2 Ratings and characteristics . 9
4.3 Environmental characteristics for outdoor sockets . 11
4.4 Test schedule and inspection requirements . 11
4.4.1 Acceptance tests . 11
4.4.2 Periodic tests. 11
4.5 Procedures . 13
4.5.1 Quality conformance inspection . 13
4.5.2 Qualification approval and its maintenance . 13
5 Instructions for preparation of detail specifications . 13
5.1 General . 13
5.2 Identification of the detail specification . 14
5.3 Identification of the component . 14
5.4 Performance . 14
5.5 Marking, ordering information and related matters . 14
5.6 Selection of tests, test conditions and severities . 14
5.7 Blank detail specification pro-forma for type F connector . 15

Figure 1 – Connector “F-Quick” type male plug: General dimensions . 6
Figure 2 – Example of connector “F-Quick” type male plug with resilient outer
conductor sleeve (indoor) . 7
Figure 3 – Example of connector “F-Quick” type male plug with slotted outer conductor
(indoor) . 7
Figure 4 – Example of connector “F-Quick” type male plug with slotted outer conductor
and snap ring (indoor) . 8
Figure 5 – Mechanical gauge . 8

Table 1 – Connector “F” type male plug (indoor) . 6
Table 2 – Ratings and characteristics (1 of 2) . 9
Table 3 – Acceptance tests . 11
Table 4 – Periodic tests (1 of 2) . 12

---------------------- Page: 8 ----------------------

SIST EN 61169-47:2013
61169-47 © IEC:2012(E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

RADIO-FREQUENCY CONNECTORS –

Part 47: Sectional specification for radio-frequency coaxial
connectors with clamp coupling, typically for use in
75 Ω cable networks (type F-Quick)


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-47 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
The text of this standard is based on the following documents:
CDV Report on voting
46F/204/CDV 46F/213/RVC

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 9 ----------------------

SIST EN 61169-47:2013
– 4 – 61169-47 © IEC:2012(E)
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct understanding
of its contents. Users should therefore print this document using a colour printer.

---------------------- Page: 10 ----------------------

SIST EN 61169-47:2013
61169-47 © IEC:2012(E) – 5 –
RADIO-FREQUENCY CONNECTORS –

Part 47: Sectional specification for radio-frequency coaxial
connectors with clamp coupling, typically for use in
75 Ω cable networks (type F-Quick)



1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for RF coaxial connectors with clamp coupling,
typically for use in 75 Ω cable networks (type F-Quick).
It describes the interface dimensions with gauging information, electrical and mechanical
performance including the mandatory tests selected from IEC 61169-1:1992, applicable to all
DS relating to type F-Quick connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a DS and covers test schedules and inspection requirements.
NOTE This interface is typically used for indoor connections, which are easily disconnected and reconnected. The
typical application is for F-type coaxial receiver leads or F-type coaxial patch cables. The interface may also be
known as a Push – On connector.
It is preferred to use the fixed (screwed) connectors type F according to IEC 61169-24:2009.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
1
requirements and measuring methods
Amendment 1:1996
Amendment 2:1997
IEC 61169-24:2009, Radio-frequency connectors – Part 24: Sectional specification – Radio
frequency coaxial connectors with screw coupling, typically for use in 75 Ω cable networks
(type F)
3 Interface dimensions
3.1 Dimensions
3.1.1 Common dimensions
Millimetres are original dimensions.
All un-dimensioned pictorial configurations are for reference purposes only.
___________
1
 There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1:1992, its Amendment 1:1996 and its
Amendment 2:1997.

---------------------- Page: 11 ----------------------

SIST EN 61169-47:2013
– 6 – 61169-47 © IEC:2012(E)
Figure 1 and Table 1 depict the dimensions that are common to any F connector and thus
indispensable for compatibility. Examples of specific design with their dimensions are given in
3.1.2 to 3.1.4.
B
A

0,100
A
Reference plane
IEC  1462/12


Figure 1 – Connector “F-Quick” type male plug: General dimensions

Table 1 – Connector “F” type male plug (indoor)
DESCRIPTION DIM mm inches NOTES
 Min. Max. Min. Max.
Inner conductor length A 6,35 8,63 0,250 0,340
Length of nut B 4,00 7,29 0,167 0,287
Maximum envelope dimension C 16,61 0,654
Inner conductor diameter D 0,64 1,13 0,025 0,044
Reference plane opening inner diameter F 6,84 0,230 1
Reference plane outer diameter G 7,11 0,280
1 No protrusion of the dielectric beyond the reference plane is permitted.
3.1.2 Example of connector “F-Quick” type male plug with resilient outer conductor
sleeve (indoor) physical dimensions
The connector is shown in Figure 2. Common dimensions are given in 3.1.1.


∅E
∅G
∅F
∅D
∅C

---------------------- Page: 12 ----------------------

SIST EN 61169-47:2013
61169-47 © IEC:2012(E) – 7 –

Dimension in millimetres

Cone or radius
      Resilient sleeve
Min. 7,5
IEC  1463/12

Figure 2 – Example of connector “F-Quick” type
male plug with resilient outer conductor sleeve (indoor)
3.1.3 Example of connector “F-Quick” type male plug with slotted outer conductor
(indoor) physical dimensions
The connector is shown in Figure 3. Common dimensions are given in 3.1.1.
Dimension in millimetres
             Minimum 6× slotted
IEC  1464/12


Figure 3 – Example of connector “F-Quick” type male plug
with slotted outer conductor (indoor)
3.1.4 Example of connector “F-Quick” type male plug with slotted outer conductor
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.