SIST EN 301 166-1 V1.3.2:2010
(Main)Electromagnetic compatibility and Radio spectrum Matters (ERM) - Land Mobile Service - Radio equipment for analogue and/or digital communication (speech and/or data) and operating on narrow band channels and having an antenna connector - Part 1: Technical characteristics and methods of measurement
- Abstract
Since the publication of EN 301 166-1 v1.2.1 (2007-07), some technical issues with the receiver section have been identified. The problems were inhereted from v1.1.1. The required changes are small but significant for practical equipment design.
- Status
- Published
- Publication Date
- 15-Dec-2009
- Technical Committee
- MOC - Mobile Communications
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 02-Dec-2009
- Due Date
- 06-Feb-2010
- Completion Date
- 16-Dec-2009
Buy Documents
ETSI EN 301 166-1 V1.3.2 (2009-11) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment for analogue and/or digital communication (speech and/or data) and operating on narrow band channels and having an antenna connector; Part 1: Technical characteristics and methods of measurement
SIST EN 301 166-1 V1.3.2:2010 is the Slovenian adoption of ETSI EN 301 166-1 V1.3.2, published by SIST for the land mobile service. It specifies technical characteristics and methods of measurement for PMR radio equipment used for analogue and/or digital speech and data on narrow band channels with an antenna connector, so manufacturers, test labs, and buyers can check transmitter, receiver, and duplex performance in a repeatable way.
What does SIST EN 301 166-1 V1.3.2:2010 specify?
SIST EN 301 166-1 V1.3.2:2010 defines how to measure radio equipment for the Private Mobile Radio (PMR) land mobile service over 30 MHz to 3 GHz. It covers base stations, mobile stations, and handportable stations when they have an antenna connector or an internal 50 Ω RF access point for testing.
The document also states how the equipment is to be presented for testing, which test conditions apply, which test signals are used, and how transmitter, receiver, and duplex characteristics are measured. That structure matters because the same measurement can give different results unless the setup, power source, and signal access are controlled.
| Annex | What it covers |
|---|---|
| Annex A | Radiated measurement, including test sites, guidance on site use, and signal coupling |
| Annex B | Spectrum analyser specification for the measurements that use it |
| Annex C | Specification for the measurement filter used for transient power tests |
| Annex D | Bibliography |
What are the key requirements of SIST EN 301 166-1 V1.3.2:2010?
Equipment presentation and test conditions
Clause 4 requires the equipment to meet the document across all frequencies it is intended to use, and the provider or manufacturer to declare the operating frequency range, operating conditions, and power requirements. The test lab also needs the technical documentation and operating manuals to set up the measurements correctly.
Clause 5 requires testing under normal conditions and, where stated, under extreme conditions. It also requires a suitable test power source with low internal impedance, measurement of the supply voltage at the equipment terminals, thermal balance before extreme-temperature tests, and special handling for equipment with integral antennas.
In practice, this means the test result should reflect the device as it is intended to run, not a laboratory-only configuration. For battery-powered equipment, the test source is applied close to the battery terminals, and for equipment with internal temperature stabilization circuits, the stabilisation function is handled in a controlled way during the test.
Test signals, access points, and test setup
Clause 6 defines the test signals used for analogue and digital transmitter and receiver tests, including B1, M2, M3, M5, M6, M7, and C1. It also sets the use of a 50 Ω artificial antenna for conducted transmitter measurements, and it requires unwanted receiver features such as mute, squelch, and automatic transmitter shut-off to be made inoperative when the test needs that.
The clause also defines where the test signals are applied. Analogue transmitter tests use the audio input connector, receiver tests use 50 Ω RF sources, and digital tests can use defined bit-stream access points closer to the air interface.
This matters because the result depends on whether the test is done at the audio interface, the bit-stream interface, or the RF connector. The document therefore gives the lab a controlled path from the application data through coding and modulation to the air interface.
Transmitter performance
Clause 7 covers maximum conducted power, maximum effective radiated power, adjacent and alternate channel power, unwanted emissions in the spurious domain, intermodulation attenuation, transient power, and frequency error. The transmitter tests are split between equipment with an external 50 Ω antenna connector and equipment with integral antenna arrangements.
Adjacent and alternate channel power is measured with the transmitter in normal and extreme conditions, and the document gives the measurement method and limits by reference to the channel spacing and channel bandwidth used. The spurious-emission methods also require checking the transmitter both while modulated and in stand-by, because some unwanted emissions only appear in one state.
The intermodulation attenuation method applies only to transmitters used in base stations. The transient power section uses a defined measurement device and filter characteristic, which matters for equipment that switches on and off or changes power quickly.
Receiver performance
Clause 8 covers maximum usable sensitivity for analogue and digital receivers, both by conducted measurement and by field strength. It then addresses adjacent channel selectivity, spurious response rejection, blocking or desensitization, spurious radiations, and co-channel rejection.
For analogue equipment, sensitivity is tied to SINAD. For digital equipment, the methods use bit error ratio for continuous bit streams or successful message ratio for message-based operation. That distinction matters in practice because a digital radio may need to prove performance on the bit stream that actually carries the service, not just on an analogue audio signal.
The clause also separates normal and extreme-condition testing where needed, and it treats adaptive-rate equipment specially by requiring test coverage at the minimum and maximum compliant bit rates. For buyers and designers, this is the part that shows whether a radio will still hear weak wanted signals when other signals are nearby or when the receiver is under stress.
Duplex operation and measurement uncertainty
Clause 9 covers receiver desensitization and receiver spurious response rejection when the equipment transmits and receives at the same time. It provides arrangements for duplex filter operation and for two-antenna operation, and it states that duplex measurements are made on a single pair of frequencies as specified by the manufacturer.
Clause 10 requires the measured value to be compared with the relevant limit and the measurement uncertainty to be reported separately for each parameter. The uncertainty guidance is important because several transmitter and receiver results in this document depend on radiated methods, spectrum analysis, or multi-signal testing.
What terms does SIST EN 301 166-1 V1.3.2:2010 define?
- Channel SeParation (CSP) - The spacing between channel centres; it is used to describe adjacent and alternate channel offsets.
- Channel BandWidth (CBW) - The bandwidth used by the system, as permitted by the national administration; it is central to how the channel is placed during tests.
- Peak Envelope Power (PEP) - The average power at the highest crest of the modulation envelope during one RF cycle; it is a key transmitter power figure.
- Signal + Noise + Distortion/(noise + distortion) (SINAD) - The ratio used for analogue receiver sensitivity measurements; it shows how usable the recovered audio is.
- Listen Before Transmit (LBT) - A mode in which the RF channel is checked for activity before transmission begins.
- Equipment Under Test (EUT) - The device being measured in the laboratory or test site.
- Integral antenna - An antenna that is part of the equipment and does not use an external 50 Ω connector for connection.
Who uses SIST EN 301 166-1 V1.3.2:2010?
This standard is used by:
- Radio equipment manufacturers designing PMR base stations, mobile stations, and handportable stations.
- Test laboratories performing type tests, radiated measurements, and receiver/transmitter characterization.
- EMC and radio compliance engineers preparing technical files and test plans.
- Quality managers checking that product samples are tested consistently against the same methods.
- Buyers and specifiers who need to compare equipment by the same measurement basis before acceptance.
- Approval and conformity teams working with analogue, digital, speech, and data radio equipment for land mobile service.
In practice, they use it to verify output power, sensitivity, channel performance, unwanted emissions, and duplex behavior before release, procurement, or conformity assessment.
What changed in SIST EN 301 166-1 V1.3.2:2010 from the previous edition?
This version replaces EN 301 166-1 v1.2.1 (2007-07). The scope says that technical issues were identified in the receiver section, inherited from v1.1.1, and that the required changes are small but significant for practical equipment design.
Which standards are used with SIST EN 301 166-1 V1.3.2:2010?
| Reference | What it contributes |
|---|---|
| ANSI C63.5-2004 | Antenna calibration for radiated emission measurements |
| ITU-T Recommendation O.153 | Basic parameters for error-performance measurement at bit rates below the primary rate |
| IEC 60489-3, appendix F | Receiver measurement methods for A3E or F3E emissions, including the acoustic SINAD approach |
| ITU-R Recommendation SM.329-10 | Guidance on unwanted emissions in the spurious domain |
| ITU-T Recommendation O.41 | Psophometer requirements for telephone-type circuits |
| ETSI EN 301 166-2 | Companion part covering the harmonized essential requirements of article 3.2 of the R&TTE Directive |
| ETSI TR 100 028 | Measurement uncertainty principles for mobile radio equipment characteristics |
| ETSI TR 102 273 | Guidance on radiated methods of measurement and the related uncertainties |
What does the SIST EN 301 166-1 V1.3.2:2010 document contain?
Clauses 4 to 6 set out the test presentation, test conditions, power sources, temperatures, signals, and access arrangements. Clause 7 gives the transmitter methods and limits, while clause 8 gives the receiver methods and limits for analogue, digital, and message-based operation.
Clause 9 covers duplex operation, including desensitization with simultaneous transmission and reception and duplex-related spurious response rejection. Clause 10 gives the measurement-uncertainty rules that apply to the reported results.
Annex A describes radiated test sites and how to use them for absolute and relative measurements. Annex B defines the spectrum-analyser performance needed for the channel-power measurements, and Annex C defines the IF filter shape used for transient power testing.
The document also includes figures for adjacent and alternate channels, test access points, and measurement arrangements, plus tables for frequency bands, bandwidths, limits, and uncertainty. In use, these support design verification, type testing, and conformity assessment without changing the device under test between different measurement methods.
Buy Documents
ETSI EN 301 166-1 V1.3.2 (2009-11) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment for analogue and/or digital communication (speech and/or data) and operating on narrow band channels and having an antenna connector; Part 1: Technical characteristics and methods of measurement
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 301 166-1 V1.3.2:2010 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility and Radio spectrum Matters (ERM) - Land Mobile Service - Radio equipment for analogue and/or digital communication (speech and/or data) and operating on narrow band channels and having an antenna connector - Part 1: Technical characteristics and methods of measurement". This standard covers: Since the publication of EN 301 166-1 v1.2.1 (2007-07), some technical issues with the receiver section have been identified. The problems were inhereted from v1.1.1. The required changes are small but significant for practical equipment design.
Since the publication of EN 301 166-1 v1.2.1 (2007-07), some technical issues with the receiver section have been identified. The problems were inhereted from v1.1.1. The required changes are small but significant for practical equipment design.
SIST EN 301 166-1 V1.3.2:2010 is classified under the following ICS (International Classification for Standards) categories: 33.060.99 - Other equipment for radiocommunications; 33.070.01 - Mobile services in general; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 301 166-1 V1.3.2:2010 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 References
- 9 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 2.1 Normative references
- 2.2 Informative references
- 3 Definitions, symbols and abbreviations
- 3.1 Definitions
- 10 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 11 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 3.2 Symbols
- 3.3 Abbreviations
- 12 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 4 General
- 4.1 Presentation of equipment for testing purposes
- 13 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 5 Test conditions, power sources and ambient
- 5.1 Normal and extreme test conditions
- 5.2 Test power source
- 5.3 Normal test conditions
- 14 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 5.4 Extreme test conditions
- 15 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 5.5 Procedure for tests at extreme temperatures
- 5.6 Testing of equipment that does not have an external 50 Ω
- 16 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 6 General test conditions
- 6.1 Test signals
- 17 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 6.2 Test load (artificial antenna)
- 6.3 PEP
- 6.4 Encoders
- 6.5 Modulation processing
- 18 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 6.6 Test sites and general arrangements for radiated
- 6.7 Transmitter automatic shut-off facility
- 6.8 Arrangement for analogue test signals at the input of the
- 6.9 Arrangement for test signals at the input of the receiver
- 6.10 Receiver mute or squelch facility
- 6.11 Receiver rated audio output power
- 6.12 Facilities for access
- 19 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 6.13 Duplex equipment
- 20 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7 Technical characteristics of the transmitter
- 7.1 Maximum power (PX) (conducted)
- 7.2 Maximum effective radiated power
- 21 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 22 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7.3 Adjacent and alternate channels power
- 23 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 24 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7.4 Unwanted emissions in the spurious domain
- 25 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 26 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 27 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 30 MHz to 1 GHz 100 kHz
- 1 GHz to 12,75 GHz 1 MHz
- 28 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7.5 Intermodulation attenuation
- 29 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7.6 Transient power
- 30 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7.7 Frequency error
- 31 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 32 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 8 Technical characteristics of the receiver
- 8.1 Maximum usable sensitivity (analogue, conducted)
- 33 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 8.2 Maximum usable sensitivity (analogue, field strength)
- 34 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 8.3 Maximum usable sensitivity (digital, conducted)
- 35 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 36 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 8.4 Maximum usable sensitivity (digital, field strength)
- 37 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 38 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 39 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 8.5 Adjacent channel selectivity
- 40 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 41 ETSI EN 301 166-1 V1.3.2 (2009-11)
1 Scope
The present document covers the technical requirements for radio transmitters and receivers used in stations in the Private Mobile Radio (PMR) service. It applies to use in the land mobile service, operating on radio frequencies between 30 MHz and 3 GHz, with narrow channel separations (CSP) (less than 10 kHz) and intended for speech and/or data. It is the intention of the present document to cover any Channel Bandwidths (CBW) permitted by National Administrations for such systems, e.g. 6,25 kHz.
Table 1: Radiocommunications service frequency bands Radiocommunications service frequency bands Transmit 30 MHz to 3 000 MHz Receive 30 MHz to 3 000 MHz
In the present document different requirements are given for the different radio frequency bands, environmental conditions and types of equipment where appropriate.
In the present document, data transmission systems are defined as systems which transmit and/or receive data and/or digitized voice. The equipment comprises a transmitter and associated encoder and modulator and/or a receiver and associated demodulator and decoder.
The present document covers equipment which may use constant envelope or non-constant envelope modulation. The types of equipment covered by the present document are as follows:
- base station: equipment fitted with antenna connector;
- mobile station: equipment fitted with antenna connector.
Handportable stations:
a) either fitted with an antenna connector; or b) without an external antenna connector but fitted with a permanent internal or a temporary internal 50 Ω RF connector which allows access to the transmitter output and the receiver input. Handportable station equipment without an external or internal Radio Frequency (RF) connector and without the possibility of having a temporary internal 50 Ω RF connector is not covered by the present document.
2 References
References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
- if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document;
- for informative references.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.
ETSI
9 ETSI EN 301 166-1 V1.3.2 (2009-11)
2.1 Normative references
The following referenced documents are indispensable for the application of the present document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.
[1] ANSI C63.5-2004: "American National Standard for Electromagnetic Compatibility-Radiated Emission Measurements in Electromagnetic Interference (EMI) Control-Calibration of Antennas (9 kHz to 40 GHz)".
[2] ITU-T Recommendation O.153: "Basic parameters for the measurement of error performance at bit rates below the primary rate".
[3] IEC 60489-3 (1988): "Methods of measurement for radio equipment used in the mobile services. Part 3: Receivers for A3E or F3E emissions", appendix F.
[4] ITU-R Recommendation SM.329-10 (2003): "Unwanted emissions in the spurious domain". [5] ITU-T Recommendation O.41 (1994): "Psophometer for use on telephone-type circuits".
2.2 Informative references
The following referenced documents are not essential to the use of the present document but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the referenced document (including any amendments) applies.
[i.1] ETSI TR 100 028 (V1.4.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". [i.2] ETSI TR 102 273 (V1.2.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Improvement on Radiated Methods of Measurement (using test site) and evaluation of the corresponding measurement uncertainties".
3 Definitions, symbols and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply:
50 Ω: 50 ohm non-reactive impedance adjacent and alternate channels:
- adjacent channels are those two channels offset from the wanted channel by the channel spacing
- alternate channels are those two channels offset from the wanted channel by double the channel spacing ETSI
10 ETSI EN 301 166-1 V1.3.2 (2009-11)
f
Upper Lower Wanted Upper Lower Alternate Channel Adjacent Alternate Adjacent
Figure 1: Adjacent and alternate channel definitions audio frequency input socket: socket normally intended for connection to a microphone for the purpose of voice transmission NOTE: In some cases, this socket could be expected to be used for the input of an audio sub-carrier, modulated to carry data, such as FFSK.
base station: equipment fitted with an antenna connector, for use with an external antenna and intended for use in a fixed location bit: binary digit block: smallest quantity of information that is sent over the radio channel NOTE: A constant number of useful bits are always sent together with the corresponding redundancy bits. conducted measurements: measurements which are made using direct 50 Ω connection to the equipment under test data transmission systems: systems which transmit and/or receive data and/or digitized voice facilities socket: any socket intended for purposes other than the transmission of voice NOTE 1: The purpose of the socket and required input signals are specified by the manufacturer. NOTE 2: The audio frequency input socket and the facilities socket may be the same physical socket in some implementations.
handportable station: equipment either fitted with an antenna connector or an integral antenna, or both, normally used on a stand-alone basis, to be carried on a person or held in the hand integral antenna: antenna designed to be connected to the equipment without the use of a 50 Ω external connector and considered to be part of the equipment NOTE: An integral antenna may be fitted internally or externally to the equipment. Listen Before Transmit mode (LBT): monitoring mode in which the RF channel is checked for activity before transmitting message: user data to be transferred in one or more packets in a session mobile station: mobile equipment fitted with an antenna connector, for use with an external antenna, normally used in a vehicle or as a transportable station necessary bandwidth: for a given class of emission, the width of the frequency band which is just sufficient to ensure the transmission of information at the rate and with the quality required under specified conditions NOTE: See ITU-R Recommendation SM.329-10 [4].
ETSI
11 ETSI EN 301 166-1 V1.3.2 (2009-11)
packet: one block or a contiguous stream of blocks sent by one (logical) transmitter to one particular receiver or one particular group of receivers radiated measurements: measurements which involve the absolute measurement of a radiated field session: set of inter-related exchange of packets occupying one or several windows or part thereof (if applicable) NOTE: A session corresponds to a complete interactive procedure for interchanging data between users, comprising initiation, data transmission and termination procedures. The session can be short (e.g. 2 packets), or long (e.g. one full page of text).
switching range: maximum frequency range, as specified by the manufacturer, over which the receiver or the transmitter can be operated within the alignment range without reprogramming or realignment transmission (physical): one or several packets transmitted between power on and power off of a particular transmitter window: set of inter-related transmissions which may be limited in time by an appropriate access protocol and corresponding occupation rules
3.2 Symbols
For the purposes of the present document, the following symbols apply:
AR Alignment Range NOTE: See clause 4.1.
dB decibel dBm dB relative to 1 mW dBμV dB relative to 1 μV f Channel centre frequency
st f I1 1 intermediate frequency nd f I2 2 intermediate frequency th f In n intermediate frequency f LO Local oscillator frequency M1, M2, etc. names of test signals defined in clause 6.1 PR rms power PX Maximum power Vmin Minimum extreme test voltage Vmax Maximum extreme test voltage Tmin Minimum extreme test temperature Tmax Maximum extreme test temperature λ wavelength
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
ac alternating current Bit Binary digit CBW Channel BandWidth CSP Channel SeParation CTCSS Continuous Tone Control Squelch System CW Continuous Wave DC Direct Current EMC ElectroMagnetic Compatibility emf electromotive force EUT Equipment Under Test FFSK Fast Frequency Shift Keying GMSK Gaussian Minimum Shift Keying ETSI
12 ETSI EN 301 166-1 V1.3.2 (2009-11)
IF Intermediate Frequency LBT Listen Before Transmit OATS Open Area Test Site PEP Peak Envelope Power PMR Professional Mobile Radio RF Radio Frequency rms root mean square RSSI Receiver Signal Strength Indicator SINAD (signal + noise + distortion)/(noise + distortion) sr switching range Tx Transmitter VSWR Voltage Standing Wave Radio
4 General
4.1 Presentation of equipment for testing purposes
Each equipment to be tested submitted for testing shall fulfil the requirements of the present document on all frequencies over which it is intended to operate.
The provider or manufacturer shall declare the frequency ranges, the range of operating conditions and power requirements as applicable, to establish the appropriate test conditions. Additionally, technical documentation and operating manuals, sufficient to make the test, shall be supplied.
4.1.1 Choice of model for testing
The provider or manufacturer shall provide one or more samples of the equipment, as appropriate for testing. Stand alone equipment shall be complete with any ancillary equipment needed for testing. If an equipment has several optional features, considered not to affect the RF parameters then the tests need only to be performed on the equipment configured with that combination of features considered to be the most complex. Where practicable, equipment to be tested shall provide a 50 Ω connector for conducted RF power level measurements. In the case of integral antenna equipment, if the equipment does not have a internal permanent 50 Ω connector then it is permissible to supply a second sample of the equipment with a temporary antenna connector fitted to facilitate testing. The performance of the equipment to be tested shall be representative of the performance of the corresponding production model.
4.1.1.1 Auxiliary test equipment
All necessary test signal sources, setting up instructions and other product information shall accompany the equipment to be tested.
4.1.1.2 Declarations by the provider
The provider or manufacturer shall declare the necessary information of the equipment with respect to all technical requirements set by the present document.
In the case of hand portable equipment without a 50 Ω external antenna connector see clause 5.6. ETSI
13 ETSI EN 301 166-1 V1.3.2 (2009-11)
5 Test conditions, power sources and ambient
temperatures
5.1 Normal and extreme test conditions
Testing shall be performed under normal test conditions, and also, where stated, under extreme test conditions. The test conditions and procedures shall be as specified in clauses 5.2 to 5.5.
5.2 Test power source
During testing the power source of the equipment shall be replaced by a test power source capable of producing normal and extreme test voltages as specified in clauses 5.3.2 and 5.4.2. The internal impedance of the test power source shall be low enough for its effect on the test results to be negligible. For the purpose of tests, the voltage of the power source shall be measured at the input terminals of the equipment.
For battery operated equipment the battery shall be removed and the test power source shall be applied as close to the battery terminals as practicable.
During tests of DC powered equipment the power source voltages shall be maintained within a tolerance of < ±1 % relative to the voltage at the beginning of each test. The value of this tolerance is critical for power measurements, using a smaller tolerance will provide better measurement uncertainty values.
5.3 Normal test conditions
5.3.1 Normal temperature and humidity
The normal temperature and humidity conditions for tests shall be any convenient combination of temperature and humidity within the following ranges:
- temperature: +15 °C to +35 °C;
- relative humidity: 20 % to 75 %.
When it is impracticable to carry out the tests under these conditions, a note to this effect, stating the ambient temperature and relative humidity during the tests, shall be added to the test report.
5.3.2 Normal test power source
5.3.2.1 Mains voltage
The normal test voltage for equipment to be connected to the mains shall be the nominal mains voltage. For the purpose of the present document, the nominal voltage shall be the declared voltage or any of the declared voltages for which the equipment was designed.
The frequency of the test power source corresponding to the ac mains shall be between 49 Hz and 51 Hz.
5.3.2.2 Regulated lead-acid battery power sources used on vehicles
When the radio equipment is intended for operation from the usual types of regulated lead-acid battery power source used on vehicles the normal test voltage shall be 1,1 times the nominal voltage of the battery (for nominal voltages of 6 V and 12 V, these are 6,6 V and 13,2 V respectively).
ETSI
14 ETSI EN 301 166-1 V1.3.2 (2009-11)
5.3.2.3 Other power sources
For operation from other power sources or types of battery (primary or secondary), the normal test voltage shall be that declared by the equipment manufacturer.
5.4 Extreme test conditions
5.4.1 Extreme temperatures
For tests at extreme temperatures, measurements shall be made in accordance with the procedures specified in clause 5.5, at the upper and lower temperatures of one of the following two ranges:
- -20 °C to +55 °C; All mobile and handportable equipment.
Base stations for outdoor/uncontrolled climate conditions.
- 0 °C to +40 °C; Base stations for indoor/controlled climate conditions.
In the case of base stations equipment, the manufacturer shall declare which conditions the equipment is intended to be installed in.
5.4.2 Extreme test source voltages
5.4.2.1 Mains voltage
The extreme test voltage for equipment to be connected to an ac mains source shall be the nominal mains voltage ±10 %.
5.4.2.2 Regulated lead-acid battery power sources used on vehicles
When the equipment is intended for operation from the usual types of regulated lead-acid battery power sources used on vehicles the extreme test voltages shall be 1,3 and 0,9 times the nominal voltage of the battery (for a nominal voltage of 6 V, these are 7,8 V and 5,4 V respectively and for a nominal voltage of 12 V, these are 15,6 V and 10,8 V respectively).
5.4.2.3 Power sources using other types of batteries
The lower extreme test voltages for equipment with power sources using batteries shall be as follows:
- for the nickel metal-hydride, leclanché or lithium type: 0,85 times the nominal battery voltage;
- for the mercury or nickel-cadmium type: 0,9 times the nominal battery voltage. No upper extreme test voltages apply.
In the case where no upper extreme test voltage the nominal voltage is applicable, the corresponding four extreme test conditions are:
- V /T , V /T ; min min min max
- (V = nominal)/T , (V = nominal)/T .
max min max max
5.4.2.4 Other power sources
For equipment using other power sources, or capable of being operated from a variety of power sources, the extreme test voltages shall be those declared by the equipment manufacturer. ETSI
15 ETSI EN 301 166-1 V1.3.2 (2009-11)
5.5 Procedure for tests at extreme temperatures
Before measurements are made the equipment shall have reached thermal balance in the test chamber. The equipment shall be switched off during the temperature stabilizing period. In the case of equipment containing temperature stabilization circuits designed to operate continuously, the temperature stabilization circuits may be switched on for 15 minutes after thermal balance has been obtained, and the equipment shall then meet the specified requirements. For such equipment the manufacturer shall provide for the power source circuit feeding the crystal oven to be independent of the power source for the rest of the equipment. If the thermal balance is not checked by measurements, a temperature stabilizing period of at least one hour, or a longer period as may be decided by the testing laboratory, shall be allowed. The sequence of measurements shall be chosen, and the humidity content in the test chamber shall be controlled so that excessive condensation does not occur.
5.5.1 Procedure for equipment designed for continuous transmission
If the manufacturer states that the equipment is designed for continuous transmission, the test procedure shall be as follows.
Before tests at the upper extreme temperature, the equipment shall be placed in the test chamber, and left until thermal balance is attained. The equipment shall then be switched on in the transmit condition for a period of half an hour, after which the equipment shall meet the specified requirements.
Before tests at the lower extreme temperature, the equipment shall be left in the test chamber until thermal balance is attained, then switched to the standby or receive condition for a period of one minute, after which the equipment shall meet the specified requirements.
5.5.2 Procedure for equipment designed for intermittent transmission
If the manufacturer states that the equipment is designed for intermittent transmission, the test procedure shall be as follows.
Before tests at the upper extreme temperature, the equipment shall be placed in the test chamber, and left until thermal balance is attained. The equipment shall then be switched on for one minute in the transmit condition, followed by four minutes in the receive condition, after which the equipment shall meet the specified requirements. For tests at the lower extreme temperature, the equipment shall be left in the test chamber until thermal balance is attained, then switched to the standby or receive condition for one minute, after which the equipment shall meet the specified requirements.
5.6 Testing of equipment that does not have an external 50 Ω
RF connector (integral antenna equipment) Where equipment has an internal 50 Ω connector it shall be permitted to perform the tests at this connector. Equipment may also have a temporary internal 50 Ω connector installed for the purposes of testing. No connection shall be made to any internal permanent or temporary antenna connector during the performance of radiated emissions measurements, unless such action forms an essential part of the normal intended operation of the equipment, as declared by the manufacturer.
ETSI
16 ETSI EN 301 166-1 V1.3.2 (2009-11)
6 General test conditions
6.1 Test signals
6.1.1 Transmitter test signals
The manufacturer shall declare details of the modulation scheme used and identify how the percentage modulation can be measured or specified.
...
Contents
- 1 Scope
- 2 References
- 9 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 2.1 Normative references
- 2.2 Informative references
- 3 Definitions, symbols and abbreviations
- 3.1 Definitions
- 10 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 11 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 3.2 Symbols
- 3.3 Abbreviations
- 12 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 4 General
- 4.1 Presentation of equipment for testing purposes
- 13 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 5 Test conditions, power sources and ambient
- 5.1 Normal and extreme test conditions
- 5.2 Test power source
- 5.3 Normal test conditions
- 14 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 5.4 Extreme test conditions
- 15 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 5.5 Procedure for tests at extreme temperatures
- 5.6 Testing of equipment that does not have an external 50 Ω
- 16 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 6 General test conditions
- 6.1 Test signals
- 17 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 6.2 Test load (artificial antenna)
- 6.3 PEP
- 6.4 Encoders
- 6.5 Modulation processing
- 18 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 6.6 Test sites and general arrangements for radiated
- 6.7 Transmitter automatic shut-off facility
- 6.8 Arrangement for analogue test signals at the input of the
- 6.9 Arrangement for test signals at the input of the receiver
- 6.10 Receiver mute or squelch facility
- 6.11 Receiver rated audio output power
- 6.12 Facilities for access
- 19 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 6.13 Duplex equipment
- 20 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7 Technical characteristics of the transmitter
- 7.1 Maximum power (PX) (conducted)
- 7.2 Maximum effective radiated power
- 21 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 22 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7.3 Adjacent and alternate channels power
- 23 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 24 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7.4 Unwanted emissions in the spurious domain
- 25 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 26 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 27 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 30 MHz to 1 GHz 100 kHz
- 1 GHz to 12,75 GHz 1 MHz
- 28 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7.5 Intermodulation attenuation
- 29 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7.6 Transient power
- 30 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 7.7 Frequency error
- 31 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 32 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 8 Technical characteristics of the receiver
- 8.1 Maximum usable sensitivity (analogue, conducted)
- 33 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 8.2 Maximum usable sensitivity (analogue, field strength)
- 34 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 8.3 Maximum usable sensitivity (digital, conducted)
- 35 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 36 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 8.4 Maximum usable sensitivity (digital, field strength)
- 37 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 38 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 39 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 8.5 Adjacent channel selectivity
- 40 ETSI EN 301 166-1 V1.3.2 (2009-11)
- 41 ETSI EN 301 166-1 V1.3.2 (2009-11)
1 Scope
The present document covers the technical requirements for radio transmitters and receivers used in stations in the Private Mobile Radio (PMR) service. It applies to use in the land mobile service, operating on radio frequencies between 30 MHz and 3 GHz, with narrow channel separations (CSP) (less than 10 kHz) and intended for speech and/or data. It is the intention of the present document to cover any Channel Bandwidths (CBW) permitted by National Administrations for such systems, e.g. 6,25 kHz.
Table 1: Radiocommunications service frequency bands Radiocommunications service frequency bands Transmit 30 MHz to 3 000 MHz Receive 30 MHz to 3 000 MHz
In the present document different requirements are given for the different radio frequency bands, environmental conditions and types of equipment where appropriate.
In the present document, data transmission systems are defined as systems which transmit and/or receive data and/or digitized voice. The equipment comprises a transmitter and associated encoder and modulator and/or a receiver and associated demodulator and decoder.
The present document covers equipment which may use constant envelope or non-constant envelope modulation. The types of equipment covered by the present document are as follows:
- base station: equipment fitted with antenna connector;
- mobile station: equipment fitted with antenna connector.
Handportable stations:
a) either fitted with an antenna connector; or b) without an external antenna connector but fitted with a permanent internal or a temporary internal 50 Ω RF connector which allows access to the transmitter output and the receiver input. Handportable station equipment without an external or internal Radio Frequency (RF) connector and without the possibility of having a temporary internal 50 Ω RF connector is not covered by the present document.
2 References
References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
- if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document;
- for informative references.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.
ETSI
SIST EN 301 166-1 V1.3.2:2010
9 ETSI EN 301 166-1 V1.3.2 (2009-11)
2.1 Normative references
The following referenced documents are indispensable for the application of the present document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.
[1] ANSI C63.5-2004: "American National Standard for Electromagnetic Compatibility-Radiated Emission Measurements in Electromagnetic Interference (EMI) Control-Calibration of Antennas (9 kHz to 40 GHz)".
[2] ITU-T Recommendation O.153: "Basic parameters for the measurement of error performance at bit rates below the primary rate".
[3] IEC 60489-3 (1988): "Methods of measurement for radio equipment used in the mobile services. Part 3: Receivers for A3E or F3E emissions", appendix F.
[4] ITU-R Recommendation SM.329-10 (2003): "Unwanted emissions in the spurious domain". [5] ITU-T Recommendation O.41 (1994): "Psophometer for use on telephone-type circuits".
2.2 Informative references
The following referenced documents are not essential to the use of the present document but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the referenced document (including any amendments) applies.
[i.1] ETSI TR 100 028 (V1.4.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". [i.2] ETSI TR 102 273 (V1.2.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Improvement on Radiated Methods of Measurement (using test site) and evaluation of the corresponding measurement uncertainties".
3 Definitions, symbols and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply:
50 Ω: 50 ohm non-reactive impedance adjacent and alternate channels:
- adjacent channels are those two channels offset from the wanted channel by the channel spacing
- alternate channels are those two channels offset from the wanted channel by double the channel spacing ETSI
SIST EN 301 166-1 V1.3.2:2010
10 ETSI EN 301 166-1 V1.3.2 (2009-11)
f
Upper Lower Wanted Upper Lower Alternate Channel Adjacent Alternate Adjacent
Figure 1: Adjacent and alternate channel definitions audio frequency input socket: socket normally intended for connection to a microphone for the purpose of voice transmission NOTE: In some cases, this socket could be expected to be used for the input of an audio sub-carrier, modulated to carry data, such as FFSK.
base station: equipment fitted with an antenna connector, for use with an external antenna and intended for use in a fixed location bit: binary digit block: smallest quantity of information that is sent over the radio channel NOTE: A constant number of useful bits are always sent together with the corresponding redundancy bits. conducted measurements: measurements which are made using direct 50 Ω connection to the equipment under test data transmission systems: systems which transmit and/or receive data and/or digitized voice facilities socket: any socket intended for purposes other than the transmission of voice NOTE 1: The purpose of the socket and required input signals are specified by the manufacturer. NOTE 2: The audio frequency input socket and the facilities socket may be the same physical socket in some implementations.
handportable station: equipment either fitted with an antenna connector or an integral antenna, or both, normally used on a stand-alone basis, to be carried on a person or held in the hand integral antenna: antenna designed to be connected to the equipment without the use of a 50 Ω external connector and considered to be part of the equipment NOTE: An integral antenna may be fitted internally or externally to the equipment. Listen Before Transmit mode (LBT): monitoring mode in which the RF channel is checked for activity before transmitting message: user data to be transferred in one or more packets in a session mobile station: mobile equipment fitted with an antenna connector, for use with an external antenna, normally used in a vehicle or as a transportable station necessary bandwidth: for a given class of emission, the width of the frequency band which is just sufficient to ensure the transmission of information at the rate and with the quality required under specified conditions NOTE: See ITU-R Recommendation SM.329-10 [4].
ETSI
SIST EN 301 166-1 V1.3.2:2010
11 ETSI EN 301 166-1 V1.3.2 (2009-11)
packet: one block or a contiguous stream of blocks sent by one (logical) transmitter to one particular receiver or one particular group of receivers radiated measurements: measurements which involve the absolute measurement of a radiated field session: set of inter-related exchange of packets occupying one or several windows or part thereof (if applicable) NOTE: A session corresponds to a complete interactive procedure for interchanging data between users, comprising initiation, data transmission and termination procedures. The session can be short (e.g. 2 packets), or long (e.g. one full page of text).
switching range: maximum frequency range, as specified by the manufacturer, over which the receiver or the transmitter can be operated within the alignment range without reprogramming or realignment transmission (physical): one or several packets transmitted between power on and power off of a particular transmitter window: set of inter-related transmissions which may be limited in time by an appropriate access protocol and corresponding occupation rules
3.2 Symbols
For the purposes of the present document, the following symbols apply:
AR Alignment Range NOTE: See clause 4.1.
dB decibel dBm dB relative to 1 mW dBμV dB relative to 1 μV f Channel centre frequency
st f I1 1 intermediate frequency nd f I2 2 intermediate frequency th f In n intermediate frequency f LO Local oscillator frequency M1, M2, etc. names of test signals defined in clause 6.1 PR rms power PX Maximum power Vmin Minimum extreme test voltage Vmax Maximum extreme test voltage Tmin Minimum extreme test temperature Tmax Maximum extreme test temperature λ wavelength
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
ac alternating current Bit Binary digit CBW Channel BandWidth CSP Channel SeParation CTCSS Continuous Tone Control Squelch System CW Continuous Wave DC Direct Current EMC ElectroMagnetic Compatibility emf electromotive force EUT Equipment Under Test FFSK Fast Frequency Shift Keying GMSK Gaussian Minimum Shift Keying ETSI
SIST EN 301 166-1 V1.3.2:2010
12 ETSI EN 301 166-1 V1.3.2 (2009-11)
IF Intermediate Frequency LBT Listen Before Transmit OATS Open Area Test Site PEP Peak Envelope Power PMR Professional Mobile Radio RF Radio Frequency rms root mean square RSSI Receiver Signal Strength Indicator SINAD (signal + noise + distortion)/(noise + distortion) sr switching range Tx Transmitter VSWR Voltage Standing Wave Radio
4 General
4.1 Presentation of equipment for testing purposes
Each equipment to be tested submitted for testing shall fulfil the requirements of the present document on all frequencies over which it is intended to operate.
The provider or manufacturer shall declare the frequency ranges, the range of operating conditions and power requirements as applicable, to establish the appropriate test conditions. Additionally, technical documentation and operating manuals, sufficient to make the test, shall be supplied.
4.1.1 Choice of model for testing
The provider or manufacturer shall provide one or more samples of the equipment, as appropriate for testing. Stand alone equipment shall be complete with any ancillary equipment needed for testing. If an equipment has several optional features, considered not to affect the RF parameters then the tests need only to be performed on the equipment configured with that combination of features considered to be the most complex. Where practicable, equipment to be tested shall provide a 50 Ω connector for conducted RF power level measurements. In the case of integral antenna equipment, if the equipment does not have a internal permanent 50 Ω connector then it is permissible to supply a second sample of the equipment with a temporary antenna connector fitted to facilitate testing. The performance of the equipment to be tested shall be representative of the performance of the corresponding production model.
4.1.1.1 Auxiliary test equipment
All necessary test signal sources, setting up instructions and other product information shall accompany the equipment to be tested.
4.1.1.2 Declarations by the provider
The provider or manufacturer shall declare the necessary information of the equipment with respect to all technical requirements set by the present document.
In the case of hand portable equipment without a 50 Ω external antenna connector see clause 5.6. ETSI
SIST EN 301 166-1 V1.3.2:2010
13 ETSI EN 301 166-1 V1.3.2 (2009-11)
5 Test conditions, power sources and ambient
temperatures
5.1 Normal and extreme test conditions
Testing shall be performed under normal test conditions, and also, where stated, under extreme test conditions. The test conditions and procedures shall be as specified in clauses 5.2 to 5.5.
5.2 Test power source
During testing the power source of the equipment shall be replaced by a test power source capable of producing normal and extreme test voltages as specified in clauses 5.3.2 and 5.4.2. The internal impedance of the test power source shall be low enough for its effect on the test results to be negligible. For the purpose of tests, the voltage of the power source shall be measured at the input terminals of the equipment.
For battery operated equipment the battery shall be removed and the test power source shall be applied as close to the battery terminals as practicable.
During tests of DC powered equipment the power source voltages shall be maintained within a tolerance of < ±1 % relative to the voltage at the beginning of each test. The value of this tolerance is critical for power measurements, using a smaller tolerance will provide better measurement uncertainty values.
5.3 Normal test conditions
5.3.1 Normal temperature and humidity
The normal temperature and humidity conditions for tests shall be any convenient combination of temperature and humidity within the following ranges:
- temperature: +15 °C to +35 °C;
- relative humidity: 20 % to 75 %.
When it is impracticable to carry out the tests under these conditions, a note to this effect, stating the ambient temperature and relative humidity during the tests, shall be added to the test report.
5.3.2 Normal test power source
5.3.2.1 Mains voltage
The normal test voltage for equipment to be connected to the mains shall be the nominal mains voltage. For the purpose of the present document, the nominal voltage shall be the declared voltage or any of the declared voltages for which the equipment was designed.
The frequency of the test power source corresponding to the ac mains shall be between 49 Hz and 51 Hz.
5.3.2.2 Regulated lead-acid battery power sources used on vehicles
When the radio equipment is intended for operation from the usual types of regulated lead-acid battery power source used on vehicles the normal test voltage shall be 1,1 times the nominal voltage of the battery (for nominal voltages of 6 V and 12 V, these are 6,6 V and 13,2 V respectively).
ETSI
SIST EN 301 166-1 V1.3.2:2010
14 ETSI EN 301 166-1 V1.3.2 (2009-11)
5.3.2.3 Other power sources
For operation from other power sources or types of battery (primary or secondary), the normal test voltage shall be that declared by the equipment manufacturer.
5.4 Extreme test conditions
5.4.1 Extreme temperatures
For tests at extreme temperatures, measurements shall be made in accordance with the procedures specified in clause 5.5, at the upper and lower temperatures of one of the following two ranges:
- -20 °C to +55 °C; All mobile and handportable equipment.
Base stations for outdoor/uncontrolled climate conditions.
- 0 °C to +40 °C; Base stations for indoor/controlled climate conditions.
In the case of base stations equipment, the manufacturer shall declare which conditions the equipment is intended to be installed in.
5.4.2 Extreme test source voltages
5.4.2.1 Mains voltage
The extreme test voltage for equipment to be connected to an ac mains source shall be the nominal mains voltage ±10 %.
5.4.2.2 Regulated lead-acid battery power sources used on vehicles
When the equipment is intended for operation from the usual types of regulated lead-acid battery power sources used on vehicles the extreme test voltages shall be 1,3 and 0,9 times the nominal voltage of the battery (for a nominal voltage of 6 V, these are 7,8 V and 5,4 V respectively and for a nominal voltage of 12 V, these are 15,6 V and 10,8 V respectively).
5.4.2.3 Power sources using other types of batteries
The lower extreme test voltages for equipment with power sources using batteries shall be as follows:
- for the nickel metal-hydride, leclanché or lithium type: 0,85 times the nominal battery voltage;
- for the mercury or nickel-cadmium type: 0,9 times the nominal battery voltage. No upper extreme test voltages apply.
In the case where no upper extreme test voltage the nominal voltage is applicable, the corresponding four extreme test conditions are:
- V /T , V /T ; min min min max
- (V = nominal)/T , (V = nominal)/T .
max min max max
5.4.2.4 Other power sources
For equipment using other power sources, or capable of being operated from a variety of power sources, the extreme test voltages shall be those declared by the equipment manufacturer. ETSI
SIST EN 301 166-1 V1.3.2:2010
15 ETSI EN 301 166-1 V1.3.2 (2009-11)
5.5 Procedure for tests at extreme temperatures
Before measurements are made the equipment shall have reached thermal balance in the test chamber. The equipment shall be switched off during the temperature stabilizing period. In the case of equipment containing temperature stabilization circuits designed to operate continuously, the temperature stabilization circuits may be switched on for 15 minutes after thermal balance has been obtained, and the equipment shall then meet the specified requirements. For such equipment the manufacturer shall provide for the power source circuit feeding the crystal oven to be independent of the power source for the rest of the equipment. If the thermal balance is not checked by measurements, a temperature stabilizing period of at least one hour, or a longer period as may be decided by the testing laboratory, shall be allowed. The sequence of measurements shall be chosen, and the humidity content in the test chamber shall be controlled so that excessive condensation does not occur.
5.5.1 Procedure for equipment designed for continuous transmission
If the manufacturer states that the equipment is designed for continuous transmission, the test procedure shall be as follows.
Before tests at the upper extreme temperature, the equipment shall be placed in the test chamber, and left until thermal balance is attained. The equipment shall then be switched on in the transmit condition for a period of half an hour, after which the equipment shall meet the specified requirements.
Before tests at the lower extreme temperature, the equipment shall be left in the test chamber until thermal balance is attained, then switched to the standby or receive condition for a period of one minute, after which the equipment shall meet the specified requirements.
5.5.2 Procedure for equipment designed for intermittent transmission
If the manufacturer states that the equipment is designed for intermittent transmission, the test procedure shall be as follows.
Before tests at the upper extreme temperature, the equipment shall be placed in the test chamber, and left until thermal balance is attained. The equipment shall then be switched on for one minute in the transmit condition, followed by four minutes in the receive condition, after which the equipment shall meet the specified requirements. For tests at the lower extreme temperature, the equipment shall be left in the test chamber until thermal balance is attained, then switched to the standby or receive condition for one minute, after which the equipment shall meet the specified requirements.
5.6 Testing of equipment that does not have an external 50 Ω
RF connector (integral antenna equipment) Where equipment has an internal 50 Ω connector it shall be permitted to perform the tests at this connector. Equipment may also have a temporary internal 50 Ω connector installed for the purposes of testing. No connection shall be made to any internal permanent or temporary antenna connector during the performance of radiated emissions measurements, unless such action forms an essential part of the normal intended operation of the equipment, as declared by the manufacturer.
ETSI
SIST EN 301 166-1 V1.3.2:2010
...