SIST EN 302 536-2 V1.1.1:2008
Electromagnetic compatibility and Radio spectrum Matters (ERM) - Short Range Devices (SRD) - Radio equipment in the frequency range 315 kHz to 600 kHz - Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
- Abstract
Develop specific standard for Ultra Low Power Animal Implantable Devices ( ULP-AID) - Animal implants operating in the frequency range of 315-600 kHz. This application is described in TR 102 316 (2004-03) The radio interface is defined in CEPT/ERC/Rec 70-03 , annex 12 , band c.The present document applies to Ultra Low Power Animal Implant (ULP-AID) transmitters and receivers operating in any part or all of the band from 315 kHz to 600 kHz and any associated radio apparatus transmitting in the frequency range of 315 kHz to 600 kHz including external programmers and related telecommunication devices using digital modulation techniques such as, but not limited to, FSK or pulse position modulation. In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive will apply to equipment within the scope of the present document.
- Status
- Published
- Publication Date
- 25-Mar-2008
- Technical Committee
- MOC - Mobile Communications
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 17-Mar-2008
- Due Date
- 22-May-2008
- Completion Date
- 26-Mar-2008
- Mandate
- M/284
SIST EN 302 536-2 V1.1.1:2008 is the Slovenian adoption of ETSI EN 302 536-2 V1.1.1, a Harmonized European Standard for short range radio equipment in the 315 kHz to 600 kHz band. It specifies the essential requirements of Article 3.2 of the R&TTE Directive for ultra low power animal implantable devices (ULP-AID), associated transmitters and receivers, and related equipment such as external programmers. Engineers, test labs, and compliance teams use it to check whether this radio equipment meets the radio spectrum requirements for its declared operating environment.
What does SIST EN 302 536-2 V1.1.1:2008 specify?
SIST EN 302 536-2 V1.1.1:2008 specifies the Article 3.2 radio spectrum requirements for ULP-AID equipment operating in any part or all of 315 kHz to 600 kHz. It also covers associated radio apparatus in that band, including external programmers and related telecommunication devices using digital modulation techniques such as FSK or pulse position modulation.
The standard is part 2 of a multi-part deliverable for radio equipment in this frequency range. Part 1, EN 302 536-1, provides the technical characteristics and test methods used throughout this part.
The document is organized into:
- Clause 1 - Scope
- Clause 2 - References
- Clause 3 - Definitions, symbols and abbreviations
- Clause 4 - Technical requirements and specifications
- Clause 5 - Testing for compliance with technical requirements
- Annexes A to C
| Annex | What it covers |
|---|---|
| A | HS Requirements and conformance Test specifications Table (HS-RTT) |
| B | EN title in the official languages |
| C | Bibliography |
What are the key requirements of SIST EN 302 536-2 V1.1.1:2008?
SIST EN 302 536-2 V1.1.1:2008 requires the equipment to meet the declared environmental profile and to stay within the stated limits whenever it operates inside that profile. In practice, the manufacturer has to define the operating environment and then show that the equipment still meets the radio requirements there.
Design and installation features
Clause 4.2.1 requires sound engineering practice, with the aim of reducing harmful disturbance to other equipment and services. It also says transmitters and receivers may be separate units or combined units, which matters when a product design integrates both functions.
Clause 4.2.1.2 requires an integral antenna, a dedicated external antenna, or both. If the equipment has an external antenna connection, the connector must be a unique type so that a different antenna cannot be connected by mistake.
Clause 4.2.1.3 keeps user-accessible adjustments from being easily reachable when a bad adjustment could increase interference. Clause 4.2.1.4 allows an automatic shut-off or battery-saving feature to be disabled for testing if it would otherwise interfere with the measurements.
Emission limits and test targets
Clause 4.2.2 sets the modulation bandwidth requirement by reference to EN 302 536-1, and clause 5.3.1 gives the corresponding test. This tells the lab what bandwidth to measure and compare against the applicable limits.
Clauses 4.2.3.1 and 4.2.3.2 cover the fundamental emission in both H-field and E-field terms, with tests in clause 5.3.2. That matters because the standard checks both magnetic and electric radiated output, depending on the equipment under test.
Clauses 4.2.4 and 4.2.5 cover spurious emissions from transmitters and spurious radiation from receivers. These clauses keep unwanted emissions outside the intended signal under control, which is what prevents interference to other radio users.
Test conditions and reporting
Clause 5 requires tests at representative points within the declared environmental profile, including a variety of conditions where performance changes with temperature, humidity, or other factors. Clause 5.2 also requires measurement uncertainty to be recorded in the test report and kept within the limits given in the document, using the method from TR 100 028.
Clause 5.3 ties the compliance tests to the corresponding methods in EN 302 536-1 and covers normal and extreme test conditions, the test power source, and the choice of samples. In practice, the test plan follows the companion part and the manufacturer’s declared operating conditions.
What terms does SIST EN 302 536-2 V1.1.1:2008 define?
- ULP-AID (Ultra Low Power Animal Implant Device) - an animal implant radio device operating in the 315 kHz to 600 kHz band.
- SRD (Short Range Devices) - the ETSI category for short-range radio equipment covered by this series.
- R&TTE Directive - the EU directive whose Article 3.2 essential requirements are addressed by this standard.
- H-field - the radiated magnetic field used for the fundamental emission requirement and test.
- E-field - the radiated electric field used for the fundamental emission requirement and test.
- EUT (equipment under test) - the sample being measured during compliance testing.
Who uses SIST EN 302 536-2 V1.1.1:2008?
SIST EN 302 536-2 V1.1.1:2008 is used by manufacturers of ULP-AID transmitters and receivers, and by designers of external programmers and related telecommunication devices. Test laboratories use it to run the radio tests, while regulatory and conformity teams use it to prepare technical documentation and support presumption of conformity under Article 3.2.
It is also relevant to quality managers, compliance engineers, and buyers in the animal implant and short-range radio equipment sectors. They use it to check whether a product is designed for the 315 kHz to 600 kHz ULP-AID band and whether the supplier can show the required test evidence.
Which standards are used with SIST EN 302 536-2 V1.1.1:2008?
| Document | What it contributes |
|---|---|
| ETSI EN 302 536-1 V1.1.1 | Technical characteristics and test methods, including the definitions and limits used by this part |
| ETSI TR 100 028 V1.4.1 (all parts) | Method for calculating measurement uncertainty in the test report |
| CEPT/ERC/Rec 70-03, annex 12, band c | Radio interface context for the ULP-AID application |
| TR 102 316 (2004-03) | Application description for ultra low power animal implantable devices |
What does the SIST EN 302 536-2 V1.1.1:2008 document contain?
SIST EN 302 536-2 V1.1.1:2008 contains the technical requirements for environmental profile, design, antenna arrangements, control accessibility, shut-off facilities, modulation bandwidth, fundamental emission, and spurious emissions. It also contains the compliance testing section that links each requirement to the relevant test method.
Annex A gives the HS Requirements and conformance Test specifications Table and shows which requirements are unconditional, which tests are essential, and how the requirements map to test clauses. Annex B provides the EN title in the official languages, and Annex C lists the bibliography. Clause 5.2 also includes the measurement uncertainty table used in test reporting.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 302 536-2 V1.1.1:2008 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility and Radio spectrum Matters (ERM) - Short Range Devices (SRD) - Radio equipment in the frequency range 315 kHz to 600 kHz - Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive". This standard covers: Develop specific standard for Ultra Low Power Animal Implantable Devices ( ULP-AID) - Animal implants operating in the frequency range of 315-600 kHz. This application is described in TR 102 316 (2004-03) The radio interface is defined in CEPT/ERC/Rec 70-03 , annex 12 , band c.The present document applies to Ultra Low Power Animal Implant (ULP-AID) transmitters and receivers operating in any part or all of the band from 315 kHz to 600 kHz and any associated radio apparatus transmitting in the frequency range of 315 kHz to 600 kHz including external programmers and related telecommunication devices using digital modulation techniques such as, but not limited to, FSK or pulse position modulation. In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive will apply to equipment within the scope of the present document.
Develop specific standard for Ultra Low Power Animal Implantable Devices ( ULP-AID) - Animal implants operating in the frequency range of 315-600 kHz. This application is described in TR 102 316 (2004-03) The radio interface is defined in CEPT/ERC/Rec 70-03 , annex 12 , band c.The present document applies to Ultra Low Power Animal Implant (ULP-AID) transmitters and receivers operating in any part or all of the band from 315 kHz to 600 kHz and any associated radio apparatus transmitting in the frequency range of 315 kHz to 600 kHz including external programmers and related telecommunication devices using digital modulation techniques such as, but not limited to, FSK or pulse position modulation. In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive will apply to equipment within the scope of the present document.
SIST EN 302 536-2 V1.1.1:2008 is classified under the following ICS (International Classification for Standards) categories: 33.060.20 - Receiving and transmitting equipment; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 302 536-2 V1.1.1:2008 is associated with the following European legislation: EU Directives/Regulations: 2014/53/EU, TRRTP124; Standardization Mandates: M/284. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 302 536-2 V1.1.1:2008 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-maj-2008
(OHNWURPDJQHWQD]GUXåOMLYRVWLQ]DGHYHY]YH]L]UDGLMVNLPVSHNWURP(50
1DSUDYHNUDWNHJDGRVHJD65'5DGLMVNDRSUHPDNLGHOXMHYIUHNYHQþQHP
REPRþMXRGN+]GRN+]GHO+DUPRQL]LUDQL(1NL]DMHPDELVWYHQH
]DKWHYHþOHQDGLUHNWLYH5 77(
Electromagnetic compatibility and Radio spectrum Matters (ERM) - Short Range Devices
(SRD) - Radio equipment in the frequency range 315 kHz to 600 kHz - Part 2:
Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
Ta slovenski standard je istoveten z: EN 302 536-2 Version 1.1.1
ICS:
33.060.20 Sprejemna in oddajna Receiving and transmitting
oprema equipment
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
Harmonized European Standard (Telecommunications series)
Electromagnetic compatibility
and Radio spectrum Matters (ERM);
Short Range Devices (SRD);
Radio equipment in the frequency range 315 kHz to 600 kHz;
Part 2: Harmonized EN covering essential requirements
of article 3.2 of the R&TTE Directive
2 ETSI EN 302 536-2 V1.1.1 (2007-11)
Reference
DEN/ERM-TG30-004-2
Keywords
inductive, magnetic, regulation, SRD, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2007.
All rights reserved.
TM TM TM
DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.
TM
TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
ETSI
3 ETSI EN 302 536-2 V1.1.1 (2007-11)
Contents
Intellectual Property Rights.5
Foreword.5
1 Scope.6
2 References.6
3 Definitions, symbols and abbreviations .6
3.1 Definitions.6
3.2 Symbols.6
3.3 Abbreviations.6
4 Technical requirements and specifications.7
4.1 Environmental profile.7
4.2 Conformance requirements.7
4.2.1 Mechanical and electrical design .7
4.2.1.1 General.7
4.2.1.2 Antennas.7
4.2.1.3 Controls.7
4.2.1.4 Transmitter shut-off facility.7
4.2.2 Permitted frequency range of the modulation bandwidth .7
4.2.2.1 Definition.7
4.2.2.2 Limits.7
4.2.2.3 Conformance.7
4.2.3 Effective radiated field strength of the fundamental emission.8
4.2.3.1 H-field.8
4.2.3.1.1 Definition.8
4.2.3.1.2 Limit.8
4.2.3.1.3 Conformance .8
4.2.3.2 E-field.8
4.2.3.2.1 Definition.8
4.2.3.2.2 Limit.8
4.2.3.2.3 Conformance .8
4.2.4 Spurious emissions.8
4.2.4.1 Definition.8
4.2.4.2 Limits.8
4.2.4.3 Conformance.8
4.2.5 Spurious radiation of receivers .8
4.2.5.1 Definition.8
4.2.5.2 Limits.8
4.2.5.3 Conformance.9
5 Testing for compliance with technical requirements.9
5.1 Environmental conditions for testing .9
5.2 Interpretation of the measurement results .9
5.3 Essential radio test suites.9
5.3.1 Permitted frequency range of the modulation bandwidth .9
5.3.2 Effective radiated field strength of the fundamental emission.10
5.3.3 Spurious emissions.10
5.3.4 Spurious radiation of receivers .10
5.3.5 Normal and extreme test-conditions .10
5.3.6 Test power source .10
5.3.7 Choice of samples for test suites.10
Annex A (normative): HS Requirements and conformance Test specifications Table
(HS-RTT).11
Annex B (informative): The EN title in the official languages .13
ETSI
4 ETSI EN 302 536-2 V1.1.1 (2007-11)
Annex C (informative): Bibliography.15
History .16
ETSI
5 ETSI EN 302 536-2 V1.1.1 (2007-11)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This Harmonized European Standard (Telecommunications series) has been produced by ETSI Technical Committee
Electromagnetic compatibility and Radio spectrum Matters (ERM).
The present document has been produced by ETSI in response to a mandate from the European Commission issued
under Council Directive 98/34/EC (as amended) laying down a procedure for the provision of information in the field of
technical standards and regulations.
The present document is intended to become a Harmonized Standard, the reference of which will be published in the
Official Journal of the European Communities referencing the Directive 1999/5/EC of the European Parliament and of
the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual
recognition of their conformity ("the R&TTE Directive").
Technical specifications relevant to Directive 1999/5/EC are given in annex A.
The present document is part 2 of a multi-part deliverable covering Radio Equipment in the frequency range 315 kHz to
600 kHz for Ultra Low Power Animal Implant Devices and accessory peripheral systems including devices that are
intended to be outside the body but in very close proximity to it in normal operation, as identified below:
Part 1: "Technical characteristics and test methods";
Part 2: "Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive".
National transposition dates
Date of adoption of this EN: 19 October 2007
Date of latest announcement of this EN (doa): 31 January 2008
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 July 2008
Date of withdrawal of any conflicting National Standard (dow): 31 July 2009
ETSI
6 ETSI EN 302 536-2 V1.1.1 (2007-11)
1 Scope
The present document applies to Ultra Low Power Animal Implant (ULP-AID) transmitters and receivers operating in
any part or all of the band from 315 kHz to 600 kHz and any associated radio apparatus transmitting in the frequency
range of 315 kHz to 600 kHz including external programmers and related telecommunication devices using digital
modulation techniques such as, but not limited to, FSK or pulse position modulation.
In addition to the present document, other ENs that specify technical requirements in respect of essential requirements
under other parts of article 3 of the R&TTE Directive will apply to equipment within the scope of the present document.
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication and/or edition number or version number) or
non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee
their long term validity.
[1] ETSI EN 302 536-1 (V1.1.1): "Electromagnetic compatibility and Radio spectrum Matters (ERM);
Short Range Devices (SRD); Radio equipment in the frequency range 315 kHz to 600 kHz;
Part 1: Technical characteristics and test methods".
[2] ETSI TR 100 028 (V1.4.1) (all parts): "Electromagnetic compatibility and Radio Spectrum Matters
(ERM); Uncertainties in the measurement of mobile radio equipment characteristics".
3 Definitions, symbols and abbreviations
3.1 Definitions
For the purposes of the present document, the terms and definitions given in the R&TTE Directive and
EN 302 536-1 [1] apply.
3.2 Symbols
For the purposes of the present document, the symbols given in EN 302 536-1 [1] apply.
3.3 Abbreviations
For the purposes of the present document, the abbreviations given in EN 302 536-1 [1] apply.
ETSI
7 ETSI EN 302 536-2 V1.1.1 (2007-11)
4 Technical requirements and specifications
4.1 Environmental profile
The technical requirements of the present document apply under the environmental profile for operation of the
equipment, which shall be declared by the manufacturer. The equipment shall comply with all the technical
requirements of the present document at all times when operating within the boundary limits of the declared operational
environmental profile.
4.2 Conformance requirements
4.2.1 Mechanical and electrical design
4.2.1.1 General
The equipment shall be designed, constructed and manufactured in accordance with sound engineering practice and
with the aim of minimizing harmful disturbance to other equipment and services and should not be disturbed by harmful
interference from other electronic devices. Transmitters and receivers may be individual or combination units.
4.2.1.2 Antennas
Equipment operating in the ULP-AID band shall have an integral antenna, an external dedicated antenna or both. If
provision for an external antenna connection is made, the connector shall be a unique type to prevent use of an antenna
other than a dedicated antenna supplied by the manufacturer.
4.2.1.3 Controls
Those controls that, if maladjusted, might increase the disturbing potentialities o
...