SIST EN 12384:1999
(Main)Copper and copper alloys - Determination of spring bending limit on strip
- BACK
- 31-Oct-1999
- 77.150.30
- 89/106/EEC
- INEK
Copper and copper alloys - Determination of spring bending limit on strip
This European standard specifies test methods to determine the modulus of elasticity E and the spring bending limit O fb of strip in thicknesses from 0,05 mm up to and including 1,0 mm. This standard applies to strip specified in EN 1654.
Kupfer und Kupferlegierungen - Bestimmung der Federbiegegrenze von Bändern
Diese Europäische Norm legt Prüfverfahren zur Bestimmung des Elastizitätsmodulus E und der Federbiegegrenze O fb von Bändern mit einer Dicke von 0,05 mm bis einschließlich 1,0 mm fest. Diese Norm gilt für Bänder nach EN 1654.
Cuivre et alliages de cuivre - Détermination de la limite élastique en flexion de bande
La présente norme européenne spécifie les méthodes d'essai pour déterminer le module d'élasticité E et la limite élastique en flexion O fb sur des bandes dont l'épaisseur est comprise entre 0,05 mm et 1,0 mm inclus. La présente norme s'applique aux bandes spécifiées dans l'EN 1654.
Baker in bakrove zlitine - Ugotavljanje vzmetne upogibnosti trakov
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Baker in bakrove zlitine - Ugotavljanje vzmetne upogibnosti trakovKupfer und Kupferlegierungen - Bestimmung der Federbiegegrenze von BändernCuivre et alliages de cuivre - Détermination de la limite élastique en flexion de bandeCopper and copper alloys - Determination of spring bending limit on strip77.150.30Bakreni izde
...
This May Also Interest You
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for general purposes supplied in the size range from 3 mm up to and including 450 mm outside diameter and from 0,3 mm up to and including 20 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
NOTE Tubes having an outside diameter less than 80 mm and/or a wall thickness greater than 2 mm in certain alloys are most frequently used for free machining purposes which are specified in EN 12168.
- Standard51 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft50 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the composition and property requirements for cathodes of two copper grades, designated Cu-CATH-1 (CR001A) and Cu-CATH-2 (CR002A).
Annex A (normative) describes methods for sampling cathodes for use in cases of dispute between the purchaser and the supplier. Annex B (informative) gives information on the relationships between electrical resistivity and conductivity of copper.
- Standard17 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft17 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the composition, property requirements including electrical properties, and tolerances on dimensions and form for copper rod, bar and wire for general electrical purposes. Cross sections and size ranges are:
- round, square and hexagonal rod with diameters or widths across flats from 2 mm up to and including 160 mm;
- bar with thicknesses from 2 mm up to and including 40 mm and widths from 3 mm up to and including 250 mm;
- round, square, hexagonal and rectangular wire with diameters or widths across flats from 2 mm up to and including 25 mm, as well as thicknesses from 0,5 mm up to and including 12 mm with widths from 1 mm up to and including 250 mm.
The sampling procedures and test methods for verification of conformity to the requirements of this standard are also specified.
NOTE Drawn, round copper wire - plain or tinned, single or multiline - for the manufacture of electrical conductors is specified in EN 13602.
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft28 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies methods for assessing the tin coating on drawn round copper wire for the manufacture of electrical conductors, e.g. according to EN 13602.
This European Standard includes test methods for the determination of the following characteristics:
a) thickness of the unalloyed tin coating;
b) continuity of the tin coating;
c) adherence of the tin coating.
WARNING - This European Standard can involve the use of hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with their use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard22 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft22 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the composition, property requirements including electrical properties, and tolerances on dimensions and form for copper profiles and profiled wire for electrical purposes, which would fit within a circumscribing circle of maximum 180 mm diameter.
The sampling procedures, the test methods for verification of conformity to the requirements of this standard, and the delivery conditions are also specified.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft29 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies product characteristics, assessment methods, compliance criteria and a designation system for fittings with radial and axial press ends for use with plastics and multilayer pipes. The fitting ends have a size range from 10 mm to 160 mm. The fittings are designed for a service lifetime up to fifty.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings for use with plastic and multilayer pipes may combine press ends with fitting ends defined in the other parts of EN 1254.
Press fittings for use with plastic and multilayer pipes may also have flanged end connections according to EN 1092-3.
Press fittings for use with plastic and multilayer pipes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845;
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard33 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft35 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies product characteristics, assessment methods, compliance criteria and a designation system for threaded fittings. These threaded ends exist with metallic and with non-metallic sealing elements for the purposes of joining with tubes, pipes, fittings or valves, the threaded ends have a size range from 3,175 mm (1/8") to 101,6 mm (4"). The threaded fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Threaded fittings may also have flanged end connections according to EN 1092-3.
Threaded fittings may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this document are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard18 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft24 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies product characteristics, assessment methods, compliance criteria of test results and a designation system for fittings with compression ends for use with plastic and multilayer pipes which are defined in the applicable pipe standard. For the purposes of joining plastics pipes, the fitting ends have a size range from 10 mm to 160 mm. The fittings are designed for a service lifetime up to fifty years.
The compression fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This European Standard applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Adaptor fittings for use with plastic and multilayer pipes may combine compression ends with fitting ends defined in the other parts of EN 1254.
Compression fittings for use with plastic and multilayer pipes may also have flanged end connections according to EN 1092-3.
Compression fittings for use with plastic and multilayer pipes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- Hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
b) gas applications (not valid for multilayer pipes):
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft36 pagesEnglish languagesale 10% offe-Library read for×1 day
This document contains definitions, thread dimension, reference data (minimum bore), supporting information (assembling instructions) and describes the test methods referenced by other parts of the EN 1254 series.
Thread dimensions comprise: wall thickness at threaded portions of fittings, dimensions of tail pipe ends for swivel fittings, dimensions of gas union connectors, thread dimensions and thread profile.
Test methods comprise: leak tightness under internal hydrostatic pressure, leak tightness under internal pneumatic pressure, resistance of joints to static flexural strength, resistance to pull out of joints, leak tightness of joints under vacuum, the resistance of joints to temperature cycling, resistance of joints with metallic tube to vibration, integrity of fabricated fitting bodies or having an 'as cast' microstructure, resistance to stress corrosion, detection of a carbon film on the surface of copper fittings, determination of mean depth of dezincification, resistance of joints to pressure cycling, disconnection and re-use, determining if the diameter and/or the length of engagement of a capillary end is/are within the specified tolerance, determining the minimum length of engagement of an integral solder or brazing ring socket having a formed groove.
- Standard65 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft60 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies product characteristics, assessment methods, compliance criteria of the test results and a designation system for compression fittings for connecting with copper tubes. Compression fittings exist with sealing elements - metallic and/or non-metallic - called non manipulative (commonly referenced as type A) and without sealing elements, called manipulative (commonly referenced as type B). For the purposes of joining copper tubes, the fitting ends have a size range from 6 mm to 108 mm. The compression fittings are designed for a service lifetime up to fifty years.
The fittings are used up to the operating temperatures and maximum operating pressures as indicated in Annex A.
This document applies to copper alloy fittings. A non-exhaustive list of these copper alloys is given in CEN/TS 13388.
Compression fitting ends, Type A, are used with copper tubes to EN 1057 in all material hardness conditions.
NOTE 1 Compression fittings, Type A, will possibly require an internal support when used with R220 (annealed) copper tube and the manufacturer’s advice should be sought.
Compression fitting ends, Type B, are used with R220 (annealed) or R250 (half-hard) copper tube to EN 1057.
NOTE 2 Compression fittings, Type B, may be used with R290 (hard) copper tube and the manufacturer’s advice should be sought.
Adaptor fittings for use with copper tubes may combine compression ends with fitting ends defined in the other parts of EN 1254.
Compression fittings for use with copper tubes may also have flanged end connections according to EN 1092-3.
Compression fittings for use with copper tubes may also have a plated or other decorative surface coating.
Fittings can be produced by machining, metal forming, casting, or fabrication.
Products covered by this standard are intended to be used in:
a) liquid applications:
- hot, cold or combined hot and cold water systems according to EN 806;
- closed heating systems according to EN 12828 and cooling systems;
- drainage systems;
- sprinkler systems according to EN 12845.
b) gas applications:
- natural gas and liquefied petroleum gas systems with a maximum operating pressure less than or equal to 5 bar according to EN 1775;
- compressed air systems.
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft32 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion