Switches for household and similar fixed electrical installations -- Part 2-1: Particular requirements - Electronic switches

Applies to electronic switches and to associated electronic extension units for household and similar fixed electrical installations either indoors or outdoors.

Schalter für Haushalt und ähnliche ortsfeste elektrische Installationen -- Teil 2-1: Besondere Anforderungen - Elektronische Schalter

Interrupteurs pour installations électriques fixes domestiques et analogues -- Partie 2-1: Prescriptions particulières - Interrupteurs électroniques

S'applique aux interrupteurs électroniques et aux périphériques électroniques associées pour installations domestiques et installations électriques fixes analogues soit intérieures, soit extérieures.

Stikala za gospodinjstva in podobne nepremične električne inštalacije – 2-1. del: Posebne zahteve – Elektronska stikala (IEC 60669-2-1:2002, spremenjen) (vsebuje popravek AC:2007)

General Information

Status
Published
Publication Date
31-Dec-2004
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Jan-2005
Due Date
01-Jan-2005
Completion Date
01-Jan-2005

Relations

Buy Standard

Standard
EN 60669-2-1:2005
English language
51 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60669-2-1:2005
01-januar-2005
1DGRPHãþD
SIST EN 60669-2-1:2001
SIST EN 60669-2-1:2001/A2:2003
SIST EN 60669-2-1:2001/IS1:2006
6WLNDOD]DJRVSRGLQMVWYDLQSRGREQHQHSUHPLþQHHOHNWULþQHLQãWDODFLMH±GHO
3RVHEQH]DKWHYH±(OHNWURQVNDVWLNDOD ,(&VSUHPHQMHQ  YVHEXMH
SRSUDYHN$&
Switches for household and similar fixed electrical installations -- Part 2-1: Particular
requirements - Electronic switches
Schalter für Haushalt und ähnliche ortsfeste elektrische Installationen -- Teil 2-1:
Besondere Anforderungen - Elektronische Schalter
Interrupteurs pour installations électriques fixes domestiques et analogues -- Partie 2-1:
Prescriptions particulières - Interrupteurs électroniques
Ta slovenski standard je istoveten z: EN 60669-2-1:2004
ICS:
29.120.40 Stikala Switches
SIST EN 60669-2-1:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60669-2-1:2005

---------------------- Page: 2 ----------------------

SIST EN 60669-2-1:2005
EUROPEAN STANDARD EN 60669-2-1
NORME EUROPÉENNE
EUROPÄISCHE NORM August 2004

ICS 29.120.40 Supersedes EN 60669-2-1:2000 + A2:2001 & EN 60669-2-1:2000/IS1:2004


English version


Switches for household and similar fixed electrical installations
Part 2-1: Particular requirements –
Electronic switches
(IEC 60669-2-1:2002, modified)


Interrupteurs pour installations électriques Schalter für Haushalt und ähnliche
fixes domestiques et analogues ortsfeste elektrische Installationen
Partie 2-1: Prescriptions particulières - Teil 2-1: Besondere Anforderungen -
Interrupteurs électroniques Elektronische Schalter
(CEI 60669-2-1:2002, modifiée) (IEC 60669-2-1:2002, modifiziert)






This European Standard was approved by CENELEC on 2004-07-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 60669-2-1:2004 E

---------------------- Page: 3 ----------------------

SIST EN 60669-2-1:2005
EN 60669-2-1:2004 – 2 –
Foreword
The text of the International Standard IEC 60669-2-1:2002, prepared by SC 23B, Plugs,
socket-outlets and switches, of IEC TC 23, Electrical accessories, together with the common
modifications prepared by the Technical Committee CENELEC TC 23B, Switches for household
and similar fixed electrical installations, was submitted to the formal vote and was approved by
CENELEC as EN 60669-2-1 on 2004-07-01.
This European Standard supersedes EN 60669-2-1:2000 + A2:2001 + IS1:2004.
This part 2-1 of EN 60669 is to be used in conjunction with EN 60669-1:1999. It lists the changes
necessary to convert that standard into a specific standard for electronic switches.
The following dates were fixed:
- latest date by which the EN has to be implemented
 at national level by publication of an identical
 national standard or by endorsement (dop) 2005-07-01
- latest date by which the national standards conflicting
 with the EN have to be withdrawn (dow) 2009-07-01
This European Standard was prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and supports the essential requirements
of Directive 89/336/EEC.
Annexes ZA, ZB and ZC have been added by CENELEC.
___________

---------------------- Page: 4 ----------------------

SIST EN 60669-2-1:2005
– 3 – EN 60669-2-1:2004
Endorsement notice
The text of the International Standard IEC 60669-2-1:2002 was approved by CENELEC as a
European Standard with agreed common modifications as given below.
COMMON MODIFICATIONS
2 Normative references
Replace the text of Clause 2 by:
NOTE  Normative references to international publications are listed in Annex ZA (normative).
13 Constructional requirements
13.103 Replace NOTE 2 by:
NOTE 2  See Annex ZB for special national conditions.
19 Normal operation
19.102 Add after the first paragraph:
This is not applicable to dimmers for step-down converters as these accessories are
tested according to 19.101.
101 Abnormal conditions
101.1.1.2 Add the following note:
NOTE  The tripping current of the protective devices (e.g. fuses, automatic protective devices, etc.) to
be used for the verification of electronic switches without incorporated temperature-limiting devices and
without incorporated fuses shall be in accordance with the rated current of the protective device,
specified by the manufacturer, intended to protect the electronic switch.
The manufacturers should specify in the instruction sheets provided with the products the information
regarding the protective device which is intended to protect the electronic switch.
102 Components
102.4.1.2 Replace the note by the following test requirement:
For cut-outs in electronic switches for fluorescent lamps, the tests shall be carried
out in the same way as for electronic switches for incandescent lamps.
Bibliography
Add the following note:
NOTE  Harmonized as EN 61058-1:2002 (modified)
___________

---------------------- Page: 5 ----------------------

SIST EN 60669-2-1:2005
EN 60669-2-1:2004 – 4 –
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of the
referenced document (including any amendments) applies.

NOTE When an international publication has been modified by common modifications, indicated by (mod), the
relevant EN/HD applies.
Publication Year Title EN/HD Year
IEC 60065 (mod) 2001 Audio, video and similar electronic EN 60065 2002
apparatus - Safety requirements

IEC 60085 1984 Thermal evaluation and classification HD 566 S1 1990
of electrical insulation

IEC 60127 Series Miniature fuses EN 60127 Series

IEC 60227-5 1997 Polyvinyl chloride insulated cables of - -
rated voltages up to and including
450/750 V
Part 5: Flexible cables (cords)

IEC 60317-0-1 1997 Specifications for particular types of EN 60317-0-1 1998
winding wires
Part 0-1: General requirements -
Enamelled round copper wire

IEC 60384-14 1993 Fixed capacitors for use in electronic - -
equipment
Part 14: Sectional specification: Fixed
capacitors for electromagnetic
interference suppression and
connection to the supply mains

IEC 60730 (mod) Series Automatic electrical controls for EN 60730 Series
household and similar use

IEC 61000-2-2 2002 Electromagnetic compatibility (EMC) EN 61000-2-2 2002
Part 2-2: Environment - Compatibility
levels for low-frequency conducted
disturbances and signalling in public
low-voltage power supply systems

IEC 61000-3-2 2000 Part 3-2: Limits - Limits for harmonic EN 61000-3-2 2000
(mod) current emissions (equipment input
current up to and including 16 A per
phase)

IEC 61000-3-3 1994 Part 3-3: Limits - Limitation of voltage EN 61000-3-3 1995
changes, voltage fluctuations and + Corr. July 1997
flicker in public low-voltage supply
systems, for equipment with rated
current <= 16 A per phase and not
subject to conditional connection

---------------------- Page: 6 ----------------------

SIST EN 60669-2-1:2005
– 5 – EN 60669-2-1:2004
Publication Year Title EN/HD Year
IEC 61000-4-2 1995 Part 4-2: Testing and measurement EN 61000-4-2 1995
techniques - Electrostatic discharge
immunity test

IEC 61000-4-3 2002 Part 4-3: Testing and measurement EN 61000-4-3 2002
techniques - Radiated, radio-
frequency, electromagnetic field
immunity test

IEC 61000-4-4 1995 Part 4-4: Testing and measurement EN 61000-4-4 1995
techniques - Electrical fast
transient/burst immunity test

IEC 61000-4-5 1995 Part 4-5: Testing and measurement EN 61000-4-5 1995
techniques - Surge immunity test

IEC 61000-4-6 1996 Part 4-6: Testing and measurement EN 61000-4-6 1996
techniques - Immunity to conducted
disturbances, induced by radio-
frequency fields

IEC 61000-4-8 1993 Part 4-8: Testing and measurement EN 61000-4-8 1993
techniques - Power frequency
magnetic field immunity test

IEC 61000-4-11 1994 Part 4-11: Testing and measurement EN 61000-4-11 1994
techniques - Voltage dips, short
interruptions and voltage variations
immunity tests

1) 2)
IEC 61032 - Protection of persons and equipment EN 61032 1998
by enclosures - Probes for verification

CISPR 14 Series Electromagnetic compatibility - EN 55014 Series
Requirements for household
appliances, electric tools and similar
apparatus

CISPR 15 2000 Limits and methods of measurement EN 55015 2000
of radio disturbance characteristics of
electrical lighting and similar
equipment

ISO 306 1994 Plastics - Thermoplastic materials - EN ISO 306 1994
Determination of Vicat softening
temperature (VST)



1)
Undated reference.
2)
Valid edition at date of issue.

---------------------- Page: 7 ----------------------

SIST EN 60669-2-1:2005
EN 60669-2-1:2004 – 6 –
Annex ZB
(normative)

Special national conditions

Special national condition: National characteristic or practice that cannot be changed even
over a long period, e.g. climatic conditions, electrical earthing conditions.

NOTE  If it affects harmonization, it forms part of the European Standard.

For the countries in which the relevant special national conditions apply these provisions are
normative, for other countries they are informative.

Clause Special national condition
101.1.1.2 Belgium, France, Spain, Switzerland
Electronic switches designed without an associated incorporated protection are
loaded for one hour with the conventional tripping current of the associated
protection of the lighting circuit (10 A for fuses and 16 A for CB's).
102.1 United Kingdom
Fuses according to BS 646 and BS 1362 are deemed to satisfy this requirement.
13.103 Denmark, Finland, Norway, Sweden, Switzerland, United Kingdom
Flexible cables complying with electrical strength test only are not allowed for
external use.
__________

---------------------- Page: 8 ----------------------

SIST EN 60669-2-1:2005
– 7 – EN 60669-2-1:2004
Annex ZC
(informative)

A-deviations

A-deviation: National deviation due to regulations, the alteration of which is for the time being
outside the competence of the CENELEC national member.

This European Standard falls under Directives 73/23/EEC and 89/336/EEC.

NOTE (from CEN/CENELEC IR Part 2:2002, 2.17)  Where standards fall under EC Directives, it is the view of the
Commission of the European Communities (OJ No C 59, 1982-03-09) that the effect of the decision of the Court of
Justice in case 815/79 Cremonini/Vrankovich (European Court Reports 1980, p. 3583) is that compliance with A-
deviations is no longer mandatory and that the free movement of products complying with such a standard should not
be restricted except under the safeguard procedure provided for in the relevant Directive.

A-deviations in an EFTA-country are valid instead of the relevant provisions of the European
Standard in that country until they have been removed.

Clause Deviation
13.103 Denmark
(Stærkstømbekendtgørelsen- Elektriske Installationer 2001, § 521.7.4)
The insulation of external flexible cable shall comply with or be at least electrically
and mechanically equivalent to that of flexible cables according to HD 21 or HD 22.
Finland

(Electrical Safety Act 410/1996, Degree of Ministry of Trade and Industry
No. 1193/99, paragraph 4 Publication S10-2002 of the Finnish Safety Technology
Authority, Finnish wiring rules SFS 6000-5-52 (HD 384.5.52), Clause 521,
Table 52F)
The insulation of external flexible cable shall comply with or be at least electrically
and mechanically equivalent to that of flexible cables according to HD 21 or HD 22.
Norway
(DSB: FEL 1998 §28 and §10, NEK 400:2002 Clauses 520.1 and 521.1 and
Table 52A)
Cables with basic insulation are not accepted as wiring external to the switch. The
insulation of external flexible cable shall comply with or be at least electrically and
mechanical equivalent to that of flexible cables according to HD 21 or HD 22.
Cables complying with the electric strength test only are regarded as internal cables
and are accepted to be installed in enclosures, conduits, ducting and trunking
systems and the like.
Sweden

(ELSÄK-FS: 1999:5, Clauses 520.1 and 521.1 and Table 52-1)
Cables with basic insulation are not accepted as wiring external to the switch. The
insulation of external flexible cable shall comply with or be at least electrically and
mechanical equivalent to that of flexible cables according to HD 21 or HD 22.
Cables complying with the electric strength test only are regarded as internal cables
and are accepted to be installed in enclosures, conduits, ducting and trunking
systems and the like.
__________

---------------------- Page: 9 ----------------------

SIST EN 60669-2-1:2005

Corrigendum to EN 60669-2-1:2004
English version
___________

Annex ZC
Replace the reference of the Swedish A-deviation by:
(ELSÄK-FS: 2004:1, Swedish National Electrical Safety Boards Regulations regarding design and erection
of electrical installations)
___________
December 2007

---------------------- Page: 10 ----------------------

SIST EN 60669-2-1:2005
NORME CEI
INTERNATIONALE IEC
60669-2-1
INTERNATIONAL
Quatrième édition
STANDARD
Fourth edition
2002-09
Interrupteurs pour installations électriques
fixes domestiques et analogues –
Partie 2-1:
Prescriptions particulières –
Interrupteurs électroniques
Switches for household and similar
fixed electrical installations –
Part 2-1:
Particular requirements –
Electronic switches
 IEC 2002 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch  Web: www.iec.ch
CODE PRIX
X
Commission Electrotechnique Internationale PRICE CODE
International Electrotechnical Commission
Международная Электротехническая Комиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

---------------------- Page: 11 ----------------------

SIST EN 60669-2-1:2005
60669-2-1 © IEC:2002 − 3 −
CONTENTS
FOREWORD . 7
1 Scope .11
2 Normative references.13
3 Definitions.15
4 General requirements.17
5 General notes on tests .17
6 Rating.19
7 Classification .19
8 Marking.21
9 Checking of dimensions .27
10 Protection against electric shock .27
11 Provision for earthing .29
12 Terminals.31
13 Constructional requirements.31
14 Mechanism .35
15 Resistance to ageing, protection provided by enclosures of switches, and resistance
to humidity .35
16 Insulation resistance and electric strength .35
17 Temperature rise .35
18 Making and breaking capacity .41
19 Normal operation .45
20 Mechanical strength .49
21 Resistance to heat .49
22 Screws, current-carrying parts and connections.49
23 Creepage distances, clearances and distances through sealing compound .51
24 Resistance of insulating material to abnormal heat, to fire and to tracking.51
25 Resistance to rusting.51
26 EMC requirements .51
101 Abnormal conditions.63
102 Components .69
Annex A (normative) Survey of specimens needed for tests .79
Annex B (normative) Additional requirements for switches having facilities for the outlet
and retention of flexible cables .81
Annex AA (informative)  Examples of types of electronic switches and their functions.83
Bibliography .85

---------------------- Page: 12 ----------------------

SIST EN 60669-2-1:2005
60669-2-1 © IEC:2002 − 5 −
Figure 101 – Test pin for checking the protection against electric shock.77
Figure 102 – Circuit diagram for testing electronic switches according to 101.3 .77
Table 101 – Number of specimens.19
Table 102 – Permissible temperature rise values (This table is based on table 3 of
IEC 60065).39
Table 103 – Relationship between rated current and capacitance.47
Table 104 – Immunity tests.53
Table 105 – Voltage dip and short-interruption test values .55
Table 106 – Fast transient test values.57
Table 107 – Capacitors.71

---------------------- Page: 13 ----------------------

SIST EN 60669-2-1:2005
60669-2-1 © IEC:2002 − 7 −
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
SWITCHES FOR HOUSEHOLD AND SIMILAR
FIXED ELECTRICAL INSTALLATIONS –
Part 2-1: Particular requirements –
Electronic switches
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60669-2-1 has been prepared by subcommittee 23B: Plugs, socket-
outlets and switches, of IEC technical committee 23: Electrical accessories.
This fourth edition cancels and replaces the third edition published in 1996, amendment 1
(1997) and amendment 2 (1999). It constitutes a technical revision.
The text of this standard is based on the third edition, amendments 1 and 2, and on the
following documents:
FDIS Report on voting
23B/668/FDIS 23B/682/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
This part of IEC 60669-2 shall be used in conjunction with IEC 60669-1. It lists the changes
necessary to convert that standard into a specific standard for electronic switches.

---------------------- Page: 14 ----------------------

SIST EN 60669-2-1:2005
60669-2-1 © IEC:2002 − 9 −
In this publication, the following print types are used:
− requirements proper: in roman type.
− test specifications: in italic type.
− notes: in smaller roman type.
Subclauses, figures, tables or notes which are additional to those in part 1 are numbered
starting from 101.
Annex AA is for information only.
The committee has decided that the contents of this publication will remain unchanged until 2007.
At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.

---------------------- Page: 15 ----------------------

SIST EN 60669-2-1:2005
60669-2-1 © IEC:2002 − 11 −
SWITCHES FOR HOUSEHOLD AND SIMILAR
FIXED ELECTRICAL INSTALLATIONS –
Part 2-1: Particular requirements –
Electronic switches
1 Scope
This clause of part 1 applies except as follows.
Replacement:
This standard applies to electronic switches and to associated electronic extension units for
household and similar fixed electrical installations either indoors or outdoors.
It applies to electronic switches for a.c. only, for the operation of lamp circuits and the control
of the brightness of lamps (dimmers) as well as the control of the speed of motors (for
example, those used in ventilating fans) and for other purposes (for example, heating controls),
with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A.
The operation and control as mentioned above are performed by a person via an actuating
member, a sensing surface or a sensing unit, by means of touch, proximity, turn, optical,
acoustic, thermal or any other influence.
This standard also applies to electronic switches where the operation or control is made by
physical means, for example, light, wind velocity, presence of persons, etc.
This standard also applies to boxes for electronic switches, with the exception of mounting
boxes for flush-type electronic switches.
Electronic switches complying with this standard are suitable for use at ambient temperature
not normally exceeding 25 °C but occasionally reaching 35 °C.
In locations where special conditions prevail, such as in ships, vehicles and the like and in
hazardous locations, for example, where explosions are liable to occur, special constructions
may be required.
NOTE 1 This standard is not intended to cover devices which are designed to be incorporated in appliances or are
intended to be delivered together with a specific appliance and which are within the scope of IEC 60730 or
IEC 61058-1.
Examples of designs of electronic switches and functions are shown in annex AA.
NOTE 2 Electronic switches without a mechanical switch in the main circuit do not provide a “full off-state”.
Therefore, the circuit on the load side should be considered to be live.

---------------------- Page: 16 ----------------------

SIST EN 60669-2-1:2005
60669-2-1 © IEC:2002 − 13 −
2 Normative references
This clause of part 1 applies except as follows.
Addition:
IEC 60065:2001, Audio, video and similar electronic apparatus – Safety requirements
IEC 60085:1984, Thermal evaluation and classification of electrical insulation
IEC 60127 (all parts), Miniature fuses
IEC 60227-5:1997, Polyvinyl chloride insulated cables of rated voltages up to and including
1)
450/750 V – Part 5: Flexible cables (cords)
IEC 60317-0-1:1997, Specifications for particular types of winding wires – Part 0: General
1)
requirements – Section 1: Enamelled round copper wire
IEC 60384-14:1993, Fixed capacitors for use in electronic equipment – Part 14: Sectional
specification: Fixed capacitors for electromagnetic interference suppression and connection to
the supply mains
IEC 60730 (all parts), Automatic electrical controls for household and similar use
IEC 61000-2-2:2002, Electromagnetic compatibility (EMC) – Part 2-2: Environment –
Compatibility levels for low-frequency conducted disturbances and signalling in public low-
voltage power supply systems
IEC 61000-3-2:2000, Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for
1)
harmonic current emissions (equipment input current ≤ 16A per phase)
IEC 61000-3-3:1994, Electromagnetic compatibility (EMC) – Part 3: Limits – Section 3:
Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with
1)
rated current ≤ 16 A
IEC 61000-4-2:1995, Electromagnetic compatibility (EMC) − Part 4: Testing and measurement
1)
techniques − Section 2: Electrostatic discharge immunity test
IEC 61000-4-3:2002, Electromagnetic compatibility (EMC) − Part 4-3: Testing and measure-
ment techniques − Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4:1995, Electromagnetic compatibility (EMC) − Part 4: Testing and mea
...

Questions, Comments and Discussion