SIST EN ISO 15027-2:2013
(Main)Immersion suits - Part 2: Abandonment suits, requirements including safety (ISO 15027-2:2012)
Immersion suits - Part 2: Abandonment suits, requirements including safety (ISO 15027-2:2012)
ISO 15027-2:2012 specifies performance and safety requirements for abandonment suits in emergency situations in work and leisure activities to protect the body of a user against the effects of cold water immersion, such as cold shock and hypothermia, including head, hand and feet protection.
It is applicable for dry and wet abandonment suits.
Constant wear suits are not covered by ISO 15027-2:2012. The requirements of constant wear suits are given in ISO 15027-1. Test methods are given in ISO 15027-3.
Schutzkleidung gegen Unterkühlung im Wasser - Teil 2: Seenot-Kälteschutzanzüge; Anforderungen einschließlich Sicherheit (ISO 15027-2:2012)
Dieser Teil der ISO 15027 legt Anforderungen an Leistung und Sicherheit für Seenot-Kälteschutz¬anzüge, einschließlich Kopf , Hand- und Fußschutz, für Notfälle bei Arbeits- und Freizeitaktivitäten fest, um den Körpers eines Anwenders gegen die Auswirkungen von Eintauchen in kaltes Wasser wie Kälteschock und Unterkühlung zu schützen.
Er gilt für Trocken- und Nassanzüge als Seenot-Kälteschutzanzüge.
Dieser Teil der ISO 15027 gilt nicht für Kälteschutzanzüge. Anforderungen an Kälteschutzanzüge sind ISO 15027 1:2012 zu entnehmen. Zu Prüfverfahren siehe ISO 15027 3:2012.
Combinaisons de protection thermique en cas d'immersion - Partie 2: Combinaisons d'abandon, exigences y compris la sécurité (ISO 15027-2:2012)
L'ISO 15027‑2:2012 spécifie les exigences de performances et de sécurité qui s'appliquent aux combinaisons d'abandon en conditions d'urgence pour une utilisation au travail et pour les loisirs, et destinées à protéger l'utilisateur contre les effets de l'immersion dans l'eau froide, comme le choc froid ou l'hypothermie, incluant la protection de la tête, des mains et des pieds.
Elle est applicable aux combinaisons d'abandon sèches ou humides.
Les combinaisons de port permanent ne sont pas couvertes par l'ISO 15027‑2:2012. Les exigences concernant les combinaisons de port permanent sont données dans l'ISO 15027‑1:2012. Les méthodes d'essai des combinaisons d'immersion sont données dans l'ISO 15027‑3:2012.
Potopne obleke - 2. del: Reševalne obleke, zahteve, vključno z varnostjo (ISO 15027-2:2012)
Ta del standarda ISO 15027 določa zahteve glede učinkovitosti in varnosti za reševalne obleke v nujnih primerih pri dejavnostih med delom in prostim časom, ki telo uporabnika ščitijo pred vplivi potapljanja v mrzli vodi, kot sta hladni šok in podhladitev, vključno z zaščito glave, rok in stopal. Uporablja se za suhe in mokre reševalne obleke. Stalno nošene obleke niso vključene v ta del standarda ISO 15027. Zahteve za stalno nošene obleke so navedene v standardu ISO 15027-1:2012. Preskusne metode so navedene v standardu ISO 15027-3:2012.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2013
1DGRPHãþD
SIST EN ISO 15027-2:2002
3RWRSQHREOHNHGHO5HãHYDOQHREOHNH]DKWHYHYNOMXþQR]YDUQRVWMR,62
Immersion suits - Part 2: Abandonment suits, requirements including safety (ISO 15027-
2:2012)
Schutzkleidung gegen Unterkühlung im Wasser - Teil 2: Seenot-Kälteschutzanzüge;
Anforderungen einschließlich Sicherheit (ISO 15027-2:2012)
Combinaisons de protection thermique en cas d'immersion - Partie 2: Combinaisons
d'abandon, exigences y compris la sécurité (ISO 15027-2:2012)
Ta slovenski standard je istoveten z: EN ISO 15027-2:2012
ICS:
13.340.10 Varovalna obleka Protective clothing
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 15027-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2012
ICS 13.340.10 Supersedes EN ISO 15027-2:2002
English Version
Immersion suits - Part 2: Abandonment suits, requirements
including safety (ISO 15027-2:2012)
Combinaisons de protection thermique en cas d'immersion Schutzkleidung gegen Unterkühlung im Wasser - Teil 2:
- Partie 2: Combinaisons d'abandon, exigences y compris Seenot-Kälteschutzanzüge; Anforderungen einschließlich
la sécurité (ISO 15027-2:2012) Sicherheit (ISO 15027-2:2012)
This European Standard was approved by CEN on 31 October 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2012 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 15027-2:2012: E
worldwide for CEN national Members.
Contents Page
Foreword .3
Annex ZA (informative) Relationship between this European Standard and the Essential
Requirements of EU Directive 89/686/EEC .4
Foreword
This document (EN ISO 15027-2:2012) has been prepared by Technical Committee CEN/TC 162 “Protective
clothing including hand and arm protection and lifejackets", the secretariat of which is held by DIN, in
collaboration with Technical Committee ISO/TC 188 "Small craft".
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by May 2013, and conflicting national standards shall be withdrawn at the
latest by May 2013.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN ISO 15027-2:2002.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive.
For relationship with EU Directive, see informative Annex ZA, which is an integral part of this document.
According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Annex ZA
(informative)
Relationship between this European Standard and the Essential
Requirements of EU Directive 89/686/EEC
This European Standard has been prepared under a mandate given to CEN by the European Commission
and the European Free Trade Association to provide a means of conforming to Essential Requirements of the
New Approach Directive 89/686/EEC on the approximation of the laws of the Member States relating to
personal protective equipment.
Once this standard is cited in the Official Journal of the European Union under that Directive and has been
implemented as a national standard in at least one Member State, compliance with the clauses of this
standard given in Table ZA.1 confers, within the limits of the scope of this standard, a presumption of
conformity with the corresponding Essential Requirements of that Directive and associated EFTA regulations.
Table ZA.1 — Correspondence between this standard and Directive 89/686/EEC
Clause(s)/sub- Essential Requirements (ERs) of Directive 89/686/EEC Qualifying
clause(s) of this EN remarks/Notes
4.11 1.1.1 Ergonomics
4.2.3.1, 4.11 1.1.2.1 Highest level of protection possible
4.1.2, 4.1.8, 4.1.10, 1.2.1 Absence of risks and other inherent nuisance factors
4.1.11, 4.7, 4.9
4.2.1 1.2.1.1 Suitable constituent materials
4.2.3.1 1.2.1.2 Satisfactory surface condition of all PPE parts in contact with
the user
4.11, 4.11.9 1.2.1.3 Maximum permissible user impediment
4.1.4; 4.2.2.1; 4.11.6 1.3.1 Adaptation to user's morphology
4.1.1; 4.1.5; 4.8; 1.3.2 Lightness and design strength
4.11.6; 4.12
4.1.2; 4.1.6; 4.2.2.3; 1.3.3 Compatibility of different classes or types of PPE designed
4.3; 4.4 for simultaneous use
4.1.7; 5; 6; 7 1.4 Information supplied by the manufacturer
5 h 2.4 PPE subject to ageing
4.11.3 2.7 PPE intended for emergency use or rapid installation and/or
removal
5 2.12 PPE bearing one or more identification or recognition marks
directly or indirectly relating to health and safety
4.5 2.13 PPE in the form of clothing capable of signalling the user's
presence visually
4.11.8 3.4 Protection against drowning
4.10 3.7 Protection against cold
WARNING — Other requirements and other EU Directives may be applicable to the product(s) falling
within the scope of this standard.
INTERNATIONAL ISO
STANDARD 15027-2
Second edition
2012-11-01
Immersion suits —
Part 2:
Abandonment suits, requirements
including safety
Combinaisons de protection thermique en cas d’immersion —
Partie 2: Combinaisons d’abandon, exigences y compris la sécurité
Reference number
ISO 15027-2:2012(E)
©
ISO 2012
ISO 15027-2:2012(E)
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2012 – All rights reserved
ISO 15027-2:2012(E)
Contents Page
Foreword .iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Requirements . 4
4.1 General . 4
4.2 Basic health and ergonomic requirements . 5
4.3 Accessories . 6
4.4 Buddy lines . 7
4.5 Conspicuity . 7
4.6 Foam flotation material . 9
4.7 Flammability . 9
4.8 Temperature cycling . 9
4.9 Leakage . 9
4.10 Thermal protection in water . 9
4.11 Performance requirements .10
4.12 Requirements on materials, fabrics and components . 11
5 Marking .12
6 Information supplied by the manufacturer .13
7 Consumer information at point of sale .14
7.1 Data list .14
7.2 Consumer information label .14
Annex A (informative) Guidelines for manufacturers, users, regulators and industrial inspectors about
immersion suits with respect to the application of thermal protection times relevant to the
ISO 15027 series .16
Bibliography .19
ISO 15027-2:2012(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 15027-2 was prepared by the European Committee for Standardization (CEN) Technical Committee
CEN/TC 162, Protective clothing including hand and arm protection and lifejackets, in collaboration with
Technical Committee ISO/TC 188, Small craft, Subcommittee SC 1, Personal safety equipment, in accordance
with the Agreement on technical cooperation between ISO and CEN (Vienna Agreement).
This second edition cancels and replaces the first edition (ISO 15027-2:2002), which has been technically
revised. The main technical changes are:
a) addition of terms and definitions from ISO 15027-1:2012;
b) revision of requirements for buddy lines;
c) revision of requirements regarding conspicuity;
d) addition of Clause 6 “Information supplied by the manufacturer”;
e) revision of consumer information label;
f) revision of requirements regarding thermal protection in water.
ISO 15027 consists of the following parts, under the general title Immersion suits:
— Part 1: Constant wear suits, requirements including safety
— Part 2: Abandonment suits, requirements including safety
— Part 3: Test methods
iv © ISO 2012 – All rights reserved
ISO 15027-2:2012(E)
Introduction
This part of ISO 15027 has been prepared to meet the needs of persons engaged in certain activities on or
near water. Abandonment suits manufactured and maintained according to this part of ISO 15027 will provide
protection from cold shock and delay the onset of hypothermia.
The complete immersion system (suit and clothes worn under the suit) should be able to keep the user alive long
enough for the rescue services to find and recover them. An individual’s estimated thermal protection time will
depend on water temperature and wave state as well as their physiology. Detailed in this part of ISO 15027 are
the minimum recommended insulation levels and the associated water temperatures in which they are to be used.
This part of ISO 15027 is intended to serve as a minimum performance requirement for manufacturers,
purchasers and users of such safety equipment and seeks to ensure that the equipment provides effective
performance in use. The abandonment suit should not jeopardize safety by causing undue discomfort which
could result in a degradation of performance.
The abandonment suit shall have no features which will be likely to have any detrimental effect on the operation
of other life-saving equipment that may be used. In particular, any part of the suit which might pose a snagging
hazard shall be suitably covered, protected or restrained.
The primary aims in wearing an abandonment suit are:
a) to reduce the risk of cold shock and delay the onset of hypothermia;
b) to enable the user to propel himself in the water and extricate himself from the water without it becoming
an encumbrance;
c) to make the user sufficiently conspicuous in the water so as to aid his recovery.
Many circumstances may alter the performance of the suit, such as wave action or the wearing of additional
equipment. Users, owners and employers should ensure that equipment is correctly maintained according to
the manufacturer’s instructions.
An abandonment suit may often be worn with a lifejacket as it will provide extra flotation and may help to bring
a user to a face-up position.
INTERNATIONAL STANDARD ISO 15027-2:2012(E)
Immersion suits —
Part 2:
Abandonment suits, requirements including safety
1 Scope
This part of ISO 15027 specifies performance and safety requirements for abandonment suits in emergency
situations in work and leisure activities to protect the body of a user against the effects of cold water immersion,
such as cold shock and hypothermia, including head, hand and feet protection.
It is applicable for dry and wet abandonment suits.
Constant wear suits are not covered by this part of ISO 15027. The requirements of constant wear suits are
given in ISO 15027-1:2012. Test methods are given in ISO 15027-3:2012.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
1)
CIE 15:2004, Colorimetry
EN 340, Protective clothing — General requirements
ISO 105-A02, Textiles — Tests for colour fastness — Part A02: Grey scale for assessing change in colour
ISO 105-E02, Textiles — Tests for colour fastness — Part E02: Colour fastness to sea water
ISO 105-X12, Textiles — Tests for colour fastness — Part X12: Colour fastness to rubbing
ISO 188, Rubber, vulcanized or thermoplastic — Accelerated ageing and heat resistance tests
ISO 1421, Rubber- or plastics-coated fabrics — Determination of tensile strength and elongation at break
ISO 2411:2000, Rubber- or plastics-coated fabrics — Determination of coating adhesion
ISO 3801:1977, Textiles — Woven fabrics — Determination of mass per unit length and mass per unit area
ISO 4674-1:2003, Rubber- or plastics-coated fabrics — Determination of tear resistance — Part 1: Constant
rate of tear methods
ISO 7854:1995, Rubber- or plastics-coated fabrics — Determination of resistance to damage by flexing
ISO 9227, Corrosion tests in artificial atmospheres — Salt spray tests
ISO 12401, Small craft — Deck safety harness and safety line — Safety requirements and test methods
ISO 12402-2, Personal flotation devices — Part 2: Lifejackets, performance level 275 — Safety requirements
ISO 12402-3, Personal flotation devices — Part 3: Lifejackets, performance level 150 — Safety requirements
ISO 12402-4, Personal flotation devices — Part 4: Lifejackets, performance level 100 — Safety requirements
1) Available from http://www.cie.co.at/main/publist.html.
ISO 15027-2:2012(E)
ISO 12402-5, Personal flotation devices — Part 5: Buoyancy aids (level 50) — Safety requirements
ISO 12402-6, Personal flotation devices — Part 6: Special purpose lifejackets and buoyancy aids — Safety
requirements and additional test methods
ISO 12402-7:2006, Personal flotation devices — Part 7: Materials and components — Safety requirements
and test methods
ISO 12402-8, Personal flotation devices — Part 8: Accessories — Safety requirements and test methods
ISO 12402-9:2006, Personal flotation devices — Part 9: Test methods
ISO 13934-1, Textiles — Tensile properties of fabrics — Part 1: Determination of maximum force and elongation
at maximum force using the strip method
ISO 13935-2, Textiles — Seam tensile properties of fabrics and made-up textile articles — Part 2: Determination
of maximum force to seam rupture using the grab method
ISO 15027-3:2012, Immersion suits — Part 3: Test methods
2) 3)
Resolution A.658(16) adopted by the IMO Assembly to amend the International Convention for the Safety of
Life at Sea (SOLAS), 1974, Use and fitting of retro-reflective materials on life-saving appliances
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
immersion suit
suit designed to protect the user’s body from the cooling effects of unintended immersion in water
Note 1 to entry: Cooling effects include cold shock (3.21) and hypothermia (3.14).
[SOURCE: ISO 15027-1:2012, 3.1]
3.2
constant wear suit
immersion suit designed to be routinely worn for activities on or near water in anticipation of accidental
immersion in water, but permitting physical activity to such an extent that actions can be undertaken without
undue encumbrance and thus, head, hands and feet need not be covered
[SOURCE: ISO 15027-1:2012, 3.2]
3.3
abandonment suit
immersion suit including head, hand and feet protection designed to permit rapid donning in the event of an
imminent immersion in water
[SOURCE: ISO 15027-1:2012, 3.3]
3.4
dry suit
immersion suit designed to protect the user against the effect of cold water immersion by precluding the entry
of water upon immersion
[SOURCE: ISO 15027-1:2012, 3.4]
2) Accessible at http://www.imo.org/KnowledgeCentre/HowAndWhereToFindIMOInformation/IndexofIMOResolutions/
Pages/Assembly-(A).aspx.
3) IMO is the abbreviation for International Maritime Organization. It is based in London, UK. IMO issues regulations
which are then published as laws by the member states.
2 © ISO 2012 – All rights reserved
ISO 15027-2:2012(E)
3.5
wet suit
immersion suit designed to protect the user against the effect of cold water immersion by providing insulation
and limiting the entry and exit of water upon immersion
[SOURCE: ISO 15027-1:2012, 3.5]
3.6
primary suit closure
closure used in the donning of the suit
[SOURCE: ISO 15027-1:2012, 3.6]
3.7
secondary suit closure
additional closure which can be operated by the user to enhance the fit of the suit
[SOURCE: ISO 15027-1:2012, 3.7]
3.8
inherent buoyant material
material that provides buoyancy, forming a permanent part of the suit, with a density less than that of water
[SOURCE: ISO 15027-1:2012, 3.8]
3.9
exterior fabric
outer fabric of a suit, either in the form of a single or composite fabric
[SOURCE: ISO 15027-1:2012, 3.9]
3.10
retro‑reflective material
material that reflects light beams back to their point of origin
[SOURCE: ISO 15027-1:2012, 3.10]
3.11
sprayhood
cover brought or placed in front of the face of the user in order to reduce or eliminate the splashing of water from
waves or the like onto the airways, and thereby promoting the survival of the user in rough water conditions
[SOURCE: ISO 15027-1:2012, 3.11]
3.12
buddy line
length of cord which can be tied or otherwise fixed to another person, or to that person’s personal flotation
device or other objects, so as to keep a user in the vicinity of that person or object with a view to making
location and thus rescue easier
[SOURCE: ISO 15027-1:2012, 3.12]
3.13
clo value
unit to express the relative thermal insulation values of various clothing assemblies
2 –1
Note 1 to entry: One clo is equal to 0,155 Km W .
[SOURCE: ISO 15027-1:2012, 3.13]
ISO 15027-2:2012(E)
3.14
hypothermia
condition where body core temperature is below 35 °C
[SOURCE: ISO 15027-1:2012, 3.14]
3.15
working environment
environment in which the user of a suit system would engage in normal work
[SOURCE: ISO 15027-1:2012, 3.15]
3.16
helicopter transit suit
constant wear suit worn by helicopter occupants
[SOURCE: ISO 15027-1:2012, 3.16]
3.17
offshore installation
structure or vessel that is permanently or temporarily sited at sea or away from the shore in a fresh water lake
or river and which is not covered under other international regulations
[SOURCE: ISO 15027-1:2012, 3.17]
3.18
suit system
combination of a suit and any other products which are used in conjunction with it
[SOURCE: ISO 15027-1:2012, 3.18]
3.19
underclothing
clothes worn under the suit system
[SOURCE: ISO 15027-1:2012, 3.19]
Note 1 to entry: The underclothing to be worn with the suit system shall be specified by the manufacturer. If not specified
by the manufacturer, it shall be according to ISO 15027-3:2012, 3.8.1.3.
3.20
heat strain
increase of body temperature induced by sustained heat stress which cannot be fully compensated by
temperature regulation, or activation of thermoeffective activities in response to heat stress which cause
sustained changes in the state of other, nonthermal, regulatory systems
[SOURCE: ISO 15027-1:2012, 3.20]
3.21
cold shock
short transitory phase lasting about 2 to 3 min upon sudden immersion in cold water and characterized by an
uncontrollable hyperventilation accompanied by other cardio-respiratory distress
[SOURCE: ISO 15027-1:2012, 3.21]
4 Requirements
4.1 General
4.1.1 The suit system declared to be an abandonment suit shall meet all requirements of this part of
ISO 15027. The suit shall not be damaged or fail in its determined function when tested in accordance with all
4 © ISO 2012 – All rights reserved
ISO 15027-2:2012(E)
tests in ISO 15027-3:2012, Clause 3. The test sequence shall start with the temperature cycling in accordance
with ISO 15027-3:2012, 3.9, followed by the rotating shock bin test in accordance with ISO 15027-3:2012, 3.6.
4.1.2 The manufacturer shall specify the components of the suit system including underclothing and additional
items. The abandonment suit shall cover the whole body with the exception of the face. The hood shall make a
tight fit around the face to limit water ingress. Hand covering shall be provided either by integral hand protection
or by permanently attached hand protection/gloves. Test by visual inspection.
The abandonment suit may incorporate additional items compliant with ISO 12402-8, none of which shall impair
its performance with respect to the rquirements of this part of ISO 15027, either by their presence or their use.
4.1.3 The risk of heat stress and discomfort shall be taken into account in the design and use of the suit
system. This should be accompanied in the information supplied by the manufacturer by specific advice or
warnings according to Clause 6.
NOTE In general, the higher the protection against cold shock and hypothermia, the higher is the possibility of heat
strain. The user of an abandonment suit needs to balance those two effects when choosing a device.
4.1.4 The size of the suit shall fit size(s) of the intended user(s). When multiple size ranges are provided,
the size ranges should overlap. If an adult universally sized suit is provided, it shall be sized to fit at least every
person between 1,50 m and 1,95 m. Test in accordance with ISO 15027-3:2012.
4.1.5 The rotating shock bin test according to ISO 15027-3:2012, 3.6 shall be performed on each suit before
performing the relevant tests according to ISO 15027-3:2012, Clause 3. There shall be no visible migration of
insulation material and no visible wear-and-tear damage after the rotating shock bin test.
4.1.6 Unless the suit system has been designed to be used without a PFD, the suit system shall not prevent
the donning of a personal flotation device (PFD) in accordance with ISO 12402-2 or ISO 12402-3, and the
manufacturer of the suit system shall specify the type of PFD (inflatable and/or inherent) to be used.
4.1.7 The performance requirements shall be met after cleaning in accordance with ISO 15027-3:2012,
3.7.1.1. The cleaning shall be performed according to the specification of the manufacturer.
4.1.8 The suit system shall be designed in such a way as to minimize the risk of snagging. Test in accordance
with ISO 15027-3:2012, 3.1.
4.1.9 Materials, fabrics and components shall conform with the requirements of 4.11.
4.1.10 The suit shall not contain or be accompanied by any component likely to injure or impede the user within
the context of normal use. Test in accordance with ISO 15027-3:2012, 3.10.
4.1.11 A dry suit requires a tight fit around neck or face, wrists and ankles. This is tested in the leakage test (see 4.9).
4.2 Basic health and ergonomic requirements
4.2.1 Innocuousness
The suit system shall not adversely affect the health or hygiene of the user. The materials shall not, in the
foreseeable conditions of normal use, release substances generally known to be toxic, carcinogenic, mutagenic,
allergenic, toxic to reproduction or otherwise harmful.
NOTE 1 More information can be found in ISO 13688.
ISO 15027-2:2012(E)
NOTE 2 Materials should be selected to minimize the environmental impact of the production and disposal of protective
4)
clothing (see ISO 13688:— , Annex F).
The examination, in combination with the following requirements in 4.2, shall determine whether the claim
that the materials are suitable for use in the protective clothing or protective equipment is justified. Particular
attention has to be paid to the presence of plasticizers, unreacted components, heavy metals, impurities and
the chemical identity of pigments and dyes.
4.2.2 Design
4.2.2.1 The design of the suit system shall facilitate its correct positioning on the user and shall ensure
that it remains in place for the foreseeable period of use, taking into account ambient factors, together with
the movements and postures that the wearer could adopt during the course of work or other activity. For this
purpose, appropriate means, such as adequate adjustment systems or adequate size ranges shall be provided
so as to enable protective clothing to be adapted to the morphology of the user.
4.2.2.2 The design shall ensure that no parts of the body get uncovered by expected movements by the user.
When testing according to ISO 15027-3:2012, 3.10 it shall be proven that
— the suit system can be put on and taken off easily,
— arm and knee and bending movements are possible,
— unprotected body areas do not appear during movements, and
— the manufacturer’s information is adequate to explain the correct usage.
4.2.2.3 The design of the suit system shall take into account other additional items to be worn with it. The
appropriate level of protection shall be provided at interface areas, for example sleeve to glove, trouser to
footwear, hood and respirator combinations. There may be other combinations.
4.2.3 Comfort
4.2.3.1 The suit system shall provide users with a level of comfort consistent with the level of protection against
hazards for which it is provided, the ambient conditions, the level of the user’s activity, and the anticipated
duration of use of the protective clothing.
The suit system shall not
— have rough, sharp or hard surfaces that irritate or injure the user;
— be so tight, loose and/or heavy that it restricts normal movement.
4.2.3.2 If applicable, the suit system shall be made of materials with low water vapour resistance and/or high
air permeability and/or shall be sufficiently ventilated to minimize discomfort and thermal stress.
4.2.3.3 The suit system that imposes significant ergonomic burdens such as heat stress, or is inherently
uncomfortable because of the need to provide adequate protection, should be accompanied by specific advice
or warnings in the information supplied by the manufacturer. Specific advice on the appropriate duration for
continuous use of the clothing in the intended application(s) should be given.
4.3 Accessories
If the suit is provided with accessories, such as a sprayhood, safety harnesses or safety lines, whistles, lights or
buddy lines, they shall comply with ISO 12401 and/or ISO 12402-8 and the relevant clauses of this part of ISO 15027.
4) To be published. (Revision of ISO 13688:1998.)
6 © ISO 2012 – All rights reserved
ISO 15027-2:2012(E)
If the suit is intended to be used without a personal flotation device, the suit shall be provided with a permanently
attached whistle and a light.
If the suit is intended to be used with a personal flotation device (PFD), the PFD shall be fitted with a light.
4.4 Buddy lines
A buddy line, if provided, shall be made from synthetic cord or webbing and shall be at least 1 500 mm in
length. The line shall have attached securely to the free end a releasable means for attachment to another
person or object, such as a loop, a snap hook, or a wooden or plastic toggle. The buddy line, if provided,
shall be readily accessible to at least one of the user’s gloved hands as confirmed during device testing. The
attachment means and line shall be stowed in such a way that they do not create a hazard or affect the normal
operation of the immersion suit. If hardware is provided as an attachment means, it shall not have sharp edges.
The assembly shall float in fresh water. Hardware on the buddy line shall either not be broken, or if broken,
not expose sharp edges after pull testing. Weathering testing is not required when the buddy line is normally
stowed inside a pocket,
If provided, a buddy line of the length provided by the manufacturer shall be tested as indicated for an immersion
+1
suit in accordance with ISO 12402-9:2006, 5.5.1.5 and withstand a (750 ± 50) N load for at least 3 min
without any damage. The force required to separate the buddy line from the suit shall be greater than 750 N
and less than 1 500 N. The separation of the buddy line from the immersion suit shall not adversely affect the
integrity of the immersion suit. This shall be verified by visual inspection.
The buddy line, if provided, shall be in accordance with ISO 12402-8:2006, 5.4. The buddy line, if provided,
shall be marked with “ISO 12402-8”, suffixed with the words “buddy line” at least in the official language(s) of
the country of destination. Additionally, a marking shall be included on the buddy line or the outside of a pocket
in which a buddy line is stowed, in letters at least 12 mm high, with the words “NOT FOR LIFTING” at least in
the official language(s) of the country of destination.
4.5 Conspicuity
4.5.1 Colour
4.5.1.1 The colour of the exposed portions (excluding components such as webbing, zips and other fittings)
of the suits when deployed in face-up floating position shall be in the colour range from yellow to red and the
chromaticity coordinates for non-fluorescent colours shall lie within one of the areas defined in Table 1 and
the luminance factor shall exceed the corresponding value in Table 1. The chromaticity coordinates and the
luminance factor for fluorescent colours shall comply with Table 2.
The face-up floating position is defined during in-water test according to ISO 15027-3:2012, 3.10.6.3.
4.5.1.2 The colour of the material samples shall be measured with the procedures defined in CIE 15:2004 with
polychromatic illumination D and 45/0 geometry and 2° standard observer. The specimen shall have a black
underlay with reflectance of less than 0,04. The specimens shall be conditioned for at least 24 h at (20 ± 2) °C
and (65 ± 5) % relative humidity. If the test is carried out in other conditions, the test shall be conducted within
5 min after withdrawal from the conditioning atmosphere.
4.5.1.3 The colour fastness (dry and wet) of suit material when determined in accordance with ISO 105-A02
shall be resistant to rubbing (wet and dry), when tested in accordance with ISO 105-X12 to at least step 4, and
to salt water when tested in accordance with ISO 105-E02 to at least step 4.
ISO 15027-2:2012(E)
Table 1 — Chromaticity coordinates x and y and luminance factor β for yellow, orange and red
non‑fluorescent colours of suit material
Chromaticity coordinates Luminance factor
Colour
x y β
Yellow 0,389 0,610 > 0,35
0,320 0,490
0,405 0,400
0,500 0,500
Orange 0,500 0,500 > 0,25
0,405 0,400
0,470 0,330
0,600 0,400
Red 0,610 0,400 > 0,15
0,470 0,330
0,525 0,270
0,700 0,300
Table 2 — Chromaticity coordinates x and y and luminance factor β for yellow, yellow-orange,
orange, orange‑red and red fluorescent colours of suit material
Chromaticity coordinates Luminance factor
Colour
x y
β
Fluorescent yellow 0,380 0,610 > 0,60
0,320 0,490
0,370 0,440
0,440 0,550
Fluorescent yellow- 0,440 0,550 > 0,50
orange 0,370 0,440
0,420 0,390
0,505 0,490
Fluorescent orange 0,505 0,490 > 0,40
0,420 0,390
0,460 0,350
0,575 0,425
Fluorescent orange-red 0,575 0,425 > 0,30
0,460 0,350
0,488 0,320
0,630 0,360
Fluorescent red 0,630 0,360 > 0,20
0,488 0,320
0,525 0,280
0,695 0,300
4.5.2 Retro‑reflective material
A passive light system of retro-reflective material shall be provided. This shall conform to the specification
detailed in IMO Resolution A.658(16), Annex 2. If it is the only light system, then a total area of not less than
2 2 2
400 cm shall be provided. At least 100 cm shall be affixed to the hood and in addition at least 250 cm shall
be clear of the water and visible in the suit’s normal in-water position as tested in ISO 15027-3:2012, 3.10.6.4.1.
At least one piece of 50 cm shall be affixed to the back of the suit.
The performance of the retro-reflective material shall not be degraded by the method used to apply it to the suit.
Test in accordance with ISO 15027-3:2012, 3.10.6.4.2.
An active light system shall be provided if the abandonment suit is intended to be used without a PFD. An active
light system may be provided if the abandonment suit is intended to be used with a PFD. The active light system
shall conform to the standard for emergency lights in ISO 12402-8. When an active light system is provided,
8 © ISO 2012 – All rights reserved
ISO 15027-2:2012(E)
the area covered by the passive light system may be reduced, but a minimum of 300 cm of the passive light
2 2
system should always be provided. At least 100 cm of which should be affixed to the hood and 150 cm clear
of the water and visible in the suit’s normal in-water position as tested in ISO 15027-3:2012, 3.10.6.4. At least
one piece of 50 cm shall be affixed to the back of the suit.
Alternative systems to provide conspicuity to assist search and rescue operations, such as combinations of
active light systems (emergency lights) and passive light systems (retro-reflective material) will be acceptable if
they meet the specifications for both emergency lights and retro-reflective material as defined above.
4.6 Foam flotation material
Foam flotation material used to assist the buoyancy performance of the suit system shall comply with
ISO 12402-7:2006, 4.8.
4.7 Flammability
When tested in accordance with ISO 15027-3:2012, 3.5, the abandonment suit material shall not sustain burning
nor continue melting 6 s after being removed from the flames.
4.8 Temperature cycling
The suit system shall be resistant to damage caused by changes in ambient temperature.
After temperature cycling and donning in accordance with ISO 15027-3:2012, 3.9, the suit system shall show
no visible damage to the external and internal construction components.
Additionally after temperature cycling and donning, dry suits shall be subjected to the leak test in accordance
with ISO 15027-3:2012, 3.7.
4.9 Leakage
The leakage of a dry abandonment suit system during jumping shall be measured in accordance with
ISO 15027-3:2012, 3.7.1 and the mass of measured water shall not exceed 500 g.
The leakage of a dry abandonment suit system during swimming shall also be measured in accordance with
ISO 15027-3:2012, 3.7.2 and the mass of measured water shall not exceed 200 g.
4.10 Thermal protection in water
The suit system with the underclothing specified by the manufacturer or with standard underclothing according
to ISO 15027-3:2012, 3.8.1.3 shall provide the user with thermal protection in a hydrostatical compressed state
as defined by its flotation position. The thermal insulation of the dry underclothing shall be no more than 1 Clo,
measured with the thermal manikin in air. This part of ISO 15027 recognizes the need for different levels of
thermal protection depending upon the water temperature in which the suit will be used. The conditions of
thermal protection are shown in Table 3. Testing shall be in accordance with ISO 15027-3:2012, 3.8.
None of the six human test subjects’ core temperatures shall fall more than 2 °C. Each human test subject’s
skin temperature shall not be lower than 10 °C for a time period of more than 15 min. If either of these two
requirements is not fulfilled, the suit system shall be deemed to have failed.
NOTE See Annex A for more information on thermal protection time.
ISO 15027-2:2012(E)
Table 3 — Test conditions for the different suit performance levels
a
Suit performance level
A B C D
Period of 6 4 2 2
immersion (h)
Water 2 2 5 10
temperature
(°C)
a
Tests are performed in calm water. Rough conditions (e.g. wind, waves) will decrease the stated
period of immersion.
There are two options for measuring thermal protection provided that the results are equivalent:
a) using a thermal manikin, in accordance with ISO 15027-3:2012, 3.8.1;
The validation of the thermal manikin test results shall be accompanied by an exchange of experience
between the manikin testing laboratories based on round robin testing, and the correlation of results
between the tests with human test subject and manikin.
b) using human test subjects, in accordance with ISO 15027-3:2012, 3.8.2.
4.11 Performance requirements
4.11.1 Walking
A user wearing the suit system correctly donned shall be able to walk easily as tested in accordance with
ISO 15027-3:2012, 3.10.3.2.
4.11.2 Climbing
A user wearing the suit system correctly donned shall be able to climb freely as tested in accordance with
ISO 15027-3:2012, 3.10.4.2.
4.11.3 Donning
The suit system shall be donned with all primary closures secured and any inflatable chambers inflated, if
fitted. The donning shall be tested in accordance with ISO 15027-3:2012, 3.10.2.1 a) without any damage or
impairment to the performance of the suit. The donning at (20 ± 2) °C shall be performed within 2 min. The
donning at (– 30 ± 2) °C shall be performed within 5 min. When the marking according to 5 c) 1) specifies the
suit to be worn with a personal flotation device (PFD), the donning shall be performed with the uninflated PFD.
4.11.4 Dexterity and mobility
The suit system, when correctly donned and adjusted, shall not prevent the user from bending over (without
squatting), picking up a rope, passing it around the waist and tying a double overhand knot in front of the body,
picking u
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...