Abstract

This document specifies a method for the determination of the breaking value of cationic bituminous emulsions.
WARNING - The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this document to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

Status
Not Published
Public Enquiry End Date
26-Mar-2026
Technical Committee
VLA - Water proofing
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
28-Jul-2026
Due Date
15-Sep-2026

Buy Documents

Draft

oSIST prEN 13075-1:2026

English language (18 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN 13075-1:2026 is a CEN standard for determining the breaking value of cationic bituminous emulsions by the mineral filler method. It specifies how to add a reference filler at a controlled rate to a stirred emulsion, measure the mass needed to break it, and report the result as the breaking value (BV) for 100 g of emulsion. The method is used in laboratories working with bitumens and bituminous binders when a comparable measure of breaking behaviour is needed.

What does kSIST FprEN 13075-1:2026 specify?

kSIST FprEN 13075-1:2026 specifies a laboratory method for cationic bituminous emulsions and organises the work into clauses for scope, references, terms, principle, reagents, apparatus, sampling, procedure, calculation, precision and reporting. Annex A gives the required characteristics of the reference fillers.

AnnexWhat it covers
Annex ACharacteristics of the reference fillers

The standard focuses on the mineral filler method. It also includes a safety warning telling users to assess hazards, control risks and check regulatory limits before use.

What are the key requirements of kSIST FprEN 13075-1:2026?

kSIST FprEN 13075-1:2026 requires the test to be run with a specified emulsion mass, a controlled filler feed rate and defined equipment, then reported as a calculated BV result. In practice, the method only gives comparable results when the same filler, conditioning, weighing and stirring conditions are used.

  • Clause 4, principle - Add reference filler at a uniform rate to a stirred emulsion until the emulsion breaks, then weigh the added filler. This is the core measurement: the result depends on how much filler was needed to cause breakup.
  • Clause 5.1, reference fillers - Use Forshammer SE, Q92 or Sikaisol as the reference filler and apply the conversion factors given in Clause 9. In disputes, the laboratories must use the same filler and the same procedure, which matters when results are compared between parties.
  • Clause 6, apparatus - Use either the semi-automatic or manual equipment set, including a calibrated filler feeder, timer, balance, oven and temperature control. The feeder must deliver a continuous flow of (0,35 ± 0,10) g/s, so the test depends on keeping the feed rate in range.
  • Clause 7, sampling - Take the laboratory sample in accordance with EN 58 and prepare the test sample in accordance with EN 12594. This matters because the result only represents the sample that was correctly taken and prepared.
  • Clause 8, procedure - Condition the emulsion and filler at 25 °C for at least 1,5 h, dry the filler at 110 °C to constant mass, then run either the semi-automatic or manual mixing procedure. The procedure uses about 100 g of emulsion per test and repeats the test on a second portion from the same bottle.
  • Clauses 9 and 10, calculation and expression - Calculate BV from the added filler mass and emulsion mass, convert the value to the Forshammer equivalent, report each individual value to 0,1 and the mean to the nearest integer. This gives a single number that can be compared across tests and filler types.
  • Clause 11, precision - The stated precision comes from a CEN round robin study: repeatability is 10 % and reproducibility is 40 % of the mean value. These figures help users judge whether two results are close enough to be considered consistent.
  • Clause 12, test report - Record the sample identification, reference to the document, procedure used, feeding rate, rotational speed, filler used, result, deviations, unusual features and test date. That documentation is important for audits and technical disputes.

What terms does kSIST FprEN 13075-1:2026 define?

kSIST FprEN 13075-1:2026 gives one explicit definition in Clause 3 and uses several technical terms throughout the method.

  • Breaking value (BV) - The dimensionless number corresponding to the mass of reference filler, in grams, needed to coagulate 100 g of bituminous emulsion.
  • Reference filler - The specified filler material used to run the test and make results comparable across laboratories.
  • Forshammer equivalent - The converted result basis used in Clause 9 so results from different fillers can be expressed on one scale.
  • Semi-automatic procedure - The procedure that uses a stirrer motor and metal can arrangement.
  • Manual procedure - The procedure carried out in a dish with a spatula.
  • Repeatability, r - The closeness expected between two results from the same operator and apparatus under the same conditions.
  • Reproducibility, R - The closeness expected between two results from different laboratories under normal correct use of the method.

Who uses kSIST FprEN 13075-1:2026?

kSIST FprEN 13075-1:2026 is used by laboratories testing cationic bituminous emulsions, by manufacturers of bitumens and bituminous binders, and by quality control staff who need to compare breaking behaviour. It is also relevant for technical buyers, specifiers and dispute-resolution laboratories because the standard fixes the filler type, procedure and reporting format.

In practice, users apply it to incoming-material checks, product comparison, process control and customer-supplier disagreements about emulsion performance.

What changed in kSIST FprEN 13075-1:2026 from the previous edition?

kSIST FprEN 13075-1:2026 supersedes EN 13075-1:2016. The stated changes are:

  • the name “Caolin” for the Q92 filler was removed from Clause 5.1
  • Clause 6 was updated and revised to use the metrological concept of maximum permissible measurement error
  • the stirrer description in 6.2.2 was clarified
  • Sikaisol was moved to third place in the reference fillers list in Annex A
  • the particle size distribution envelope for Q92 in Annex A was updated and tightened

Which standards are used with kSIST FprEN 13075-1:2026?

StandardWhat it contributes
EN 58Sampling bituminous binders
EN 12594Preparation of test samples
EN 12597Terminology for bitumens and bituminous binders
EN 1430Note on determining whether an emulsion is cationic or anionic
EN 933-1Constant mass and particle size distribution by sieving method
EN 933-10Grading of filler aggregates for the Forshammer SE filler
ISO 5725-2Precision framework used for the round robin evaluation
EN 13075-2Related companion part on fines mixing time of cationic bituminous emulsions

What does the kSIST FprEN 13075-1:2026 document contain?

kSIST FprEN 13075-1:2026 contains the test principle, detailed reagent and apparatus requirements, and separate procedures for semi-automatic and manual operation. It also includes the calculation formula for BV, conversion factors to the Forshammer equivalent, precision statements and the test report items.

Annex A provides the characteristics and grading limits of the reference fillers, including Forshammer SE, Q92 and Sikaisol. The document also includes figures showing the equipment set-up, stirrer design and filler grading envelopes, which support correct setup and calibration in the laboratory.

Relations

Effective Date
18-Nov-2026
Effective Date
18-Nov-2026
Effective Date
18-Nov-2026
Effective Date
19-Jan-2023
Effective Date
18-Jan-2023
Effective Date
14-Dec-2022

Buy Documents

Draft

oSIST prEN 13075-1:2026

English language (18 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Element Materials Technology

Materials testing and product certification.

UKAS United Kingdom Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN 13075-1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Bitumens and bituminous binders - Determination of breaking behaviour - Part 1: Determination of breaking value of cationic bituminous emulsions, mineral filler method". This standard covers: This document specifies a method for the determination of the breaking value of cationic bituminous emulsions. WARNING - The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this document to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

This document specifies a method for the determination of the breaking value of cationic bituminous emulsions. WARNING - The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this document to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

kSIST FprEN 13075-1:2026 is classified under the following ICS (International Classification for Standards) categories: 75.140 - Waxes, bituminous materials and other petroleum products; 91.100.50 - Binders. Sealing materials. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN 13075-1:2026 has the following relationships with other standards: It is inter standard links to SIST EN 13108-31:2019, SIST EN 14733:2005+A1:2011, SIST EN 13808:2005, SIST EN 13075-1:2017, SIST EN 13075-1:2017, SIST EN 13075-1:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN 13075-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 breaking value
  • 4 Principle
  • 5 Reagents and materials
  • 5.1 Reference fillers
  • 6 Apparatus
  • 6.1 General
  • 6.2 Equipment for semi-automatic procedure
  • 6.3 Equipment for manual procedure
  • 6.4 Equipment for both procedures
  • 1 M6 metric thread
  • 7 Sampling
  • 8 Procedure
  • 8.1 General
  • 8.2 Semi-automatic procedure
  • 8.3 Manual procedure
  • 9 Calculation
  • 10 Expression of results
  • 11 Precision
  • 11.1 General
  • 11.2 Repeatability, r
  • 11.3 Reproducibility, R
  • 12 Test report
  • Annex A
  • 30 TÄBY, Sweden
  • Bibliography

1 Scope

This document specifies a method for the determination of the breaking value of cationic bituminous emulsions.

WARNING — Use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this document to identify the hazards and assess the risks involved in performing this test method and to implement sufficient control measures to protect individual operators (and the environment). This includes appropriate safety and health practices and determination of the applicability of regulatory limitations prior to use.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 58, Bitumen and bituminous binders — Sampling bituminous binders EN 12594, Bitumens and bituminous binders — Preparation of test samples EN 12597, Bitumens and bituminous binders — Terminology

3 Terms and definitions

For the purposes of this document, the terms and definitions given in EN 12597 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp
  • IEC Electropedia: available at https://www.electropedia.org/

3.1 breaking value

BV dimensionless number corresponding to the mass of reference filler, in grams, needed to coagulate 100 g of bituminous emulsion

4 Principle

A reference filler is added at a uniform rate to a specified quantity of stirred cationic bituminous emulsion. When the emulsion has completely broken, the mass of added filler is determined by weighing. The mass of filler (in grams), multiplied by 100 and divided by the mass of emulsion (in grams), is the breaking value (3.1).

NOTE The cationic or anionic nature of an emulsion can be determined with EN 1430 [1].

oSIST prEN 13075-1:2026 prEN 13075-1:2026 (E)

5 Reagents and materials

5.1 Reference fillers

1 1 1 The Forshammer SE filler , the Q92 filler or the Sikaisol filler shall be used as reference fillers while applying the conversion factors given in Clause 9 and shall comply with the respective characteristics given in Annex A.

In case of dispute, the same filler and the same procedure (manual or semi-automatic) shall be used by the testing laboratories.

5.2 Cleaning agents, as used conventionally in laboratories.

6 Apparatus

6.1 General

The usual laboratory apparatus and glassware, together with the specific equipment described in 6.2 or 6.3, depending on the used procedure (semi-automatic or manual) and 6.4, shall be used. For the semi-automatic procedure, an explanatory sketch of the equipment set-up is described in Figure 1.

6.2 Equipment for semi-automatic procedure

6.2.1 Stirrer motor, as shown in Figure 1, with an output power of at least 25 W, and a speed of

(260 ± 60) r/min.

6.2.2 Stirrer, with blades having the dimensions given in Figure 4 and Figure 5. An example of a stirrer is shown in Figure 2 and Figure 3.

6.2.3 Metal cans, cylindrical, having an approximate capacity of 500 ml, an approximate height of 95 mm and an approximate internal diameter of 90 mm. Ensure that the internal diameter of the metal allows the stirrer blades to be below the surface of the emulsion during the test.

6.3 Equipment for manual procedure

6.3.1 Enamelled or stainless steel dish, having an approximate inner diameter of 20 cm and an

approximate height of 10 cm.

6.3.2 Spatula, made of nickel or stainless steel, having an approximate length of 20 cm.

6.4 Equipment for both procedures

6.4.1 Oven, capable of maintaining a temperature of 110 °C with a maximal permissible measurement error of ± 5 °C.

This information is given for the convenience of users of this document and does not constitute an endorsement by CEN of the products named. Equivalent products may be used if they can be shown to lead to the same results, or if a correlation between the products has been established.

oSIST prEN 13075-1:2026 prEN 13075-1:2026 (E) 6.4.2 Filler feeder, capable of supplying a continuous flow of filler at a rate of (0,35 ± 0,10) g/s during a period of time between 100 s and 600 s. Its storage capacity shall allow filler to be delivered without interruption of the flow rate over the entire duration of a test. This equipment shall be calibrated. The calibration shall be achieved by weighing the mass of the filler poured during a period of time between 100 s and 600 s depending on the anticipated test duration and measured with a maximal permissible measurement error of ± 0,2 s. The feeding rate q, in g/s, shall be calculated by using Formula (1):

m f (1) q= t where m is the added mass of filler, in g; f t is the analysis time, in s.

6.4.3 Timer or stop watch, with a maximal permissible measurement error of ± 0,2 s over a time

interval of 600 s.

6.4.4 Bottles, for storing the emulsion samples, having a capacity of approximately 500 ml, made of a material that will not react with the emulsion and having tight fitting lids.

6.4.5 Constant temperature bath or climatic chamber, capable of maintaining the sample in the

bottles at 25 °C with a maximal permissible measurement error of ± 1 °C. If the bath is used to condition the emulsion sample bottles, it should be equipped with a frame or device to prevent the plastic bottles from moving in the water bath.

6.4.6 Balance, having a suitable range, capable of weighting the test samples with a maximal

permissible measurement error of ± 0,1 g.

oSIST prEN 13075-1:2026 prEN 13075-1:2026 (E)

...