Abstract

IEC 60461:2010(E) specifies a digital time and control code for use in television, film, and accompanying audio systems operating at nominal rate of 60, 59, 94, 50, 30, 29, 97, 25, 24 and 23,98 frames per second. This International Standard specifies a time address, binary groups, and flag bit structure. In addition, the standard specifies a binary group flag assignment, a linear time code transport, and a vertical interval time code transport. It cancels and replaces the third edition published in 2001, of which it constitutes a technical revision. It includes the following significant change with regard to the previsous edition: The time code for progressive television systems with a frame rate greater than 30 frames per second is added.

Status
Published
Publication Date
29-May-2011
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
07-Apr-2011
Due Date
12-Jun-2011
Completion Date
30-May-2011

Buy Documents

Standard

SIST EN 60461:2011

English language (46 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 60461:2011, published by SIST and aligned with EN 60461:2011 / IEC 60461:2010, specifies a digital time and control code for television, film, and accompanying audio systems. It defines the time address, binary groups, flag bits, and the linear time code (LTC) and vertical interval time code (VITC) transports used to label frames, carry user data, and keep video and audio in step.

What does SIST EN 60461:2011 specify?

SIST EN 60461:2011 specifies a time and control code for nominal frame rates of 60, 59,94, 50, 30, 29,97, 25, 24, and 23,98 frames per second. The standard covers LTC for all video formats and VITC for 525/59,94 and 625/50 analogue composite and component systems.

The scope is limited to the timecode structure and its transport methods. In the scope note, digital vertical interval time code (D-VITC) is linked to SMPTE 266M, and ancillary time code (ATC) to SMPTE 12M-2 for digital systems, especially for high definition use.

AnnexWhat it covers
ZANormative references to international publications and their European publications
AExplanatory notes on time precision, leap seconds, and frames
BConverting time codes when converting video from 24 fps television systems

The document is organized into clauses for scope, references, terms, time representation, code structure, LTC, VITC, the relationship between LTC and VITC, and progressive systems above 30 fps.

What are the key requirements of SIST EN 60461:2011?

SIST EN 60461:2011 requires a unique time address for each frame, a defined bit structure for user data, and specified modulation and timing rules for LTC and VITC. In practice, implementers must generate, read, and transfer the same label in a consistent way across recording, playback, editing, and system interfacing.

Time representation and frame counting

Clause 4, Clause 5, and Clause 6 define the time address as hour, minute, second, and frame number on a 24-hour clock. For 30 fps systems, frames count 0 to 29; for 25 fps systems, 0 to 24; and for 24 fps systems, 0 to 23.

For 30 fps NTSC time, the standard allows drop frame counting to reduce drift against real time by omitting frame numbers 00 and 01 at the start of most minutes. For 25 fps and 24 fps, no drop-frame mode applies. For 50 and 60 fps progressive systems, the count advances only every other frame, so one timecode value labels a frame pair and the edit resolution is two frames.

Time address, flag bits, and binary groups

Clause 7 defines a numeric code made of sixteen four-bit groups, with eight groups for the time address and flags and eight binary groups for user data. The time address is based on binary coded decimal (BCD), and the standard names six flag bits plus eight four-bit binary groups.

The binary group flags identify how the user data is to be interpreted. The assigned combinations cover an unspecified character set, an eight-bit character set, date and time zone data, page/line multiplex data, and clock-time reference. That matters because a decoder needs the flag values to know whether the binary groups contain text, date/time information, multiplexed production data, or no defined format.

LTC requirements

Clause 8 defines LTC as an 80-bit code word. It is biphase mark encoded, so it has no DC component, can be clocked from transitions, and is suitable for recording on linear media or transporting independently of video.

The LTC bit rate is tied to the picture rate at 80 bits per frame or frame pair. The timing reference is the first transition of bit 0 relative to the associated video frame, and the standard gives alignment tolerances for the source output. It also defines interface characteristics such as rise and fall time, amplitude distortion, transition timing, and output impedance, so equipment can interoperate without depending on one vendor’s waveform shape.

VITC requirements

Clause 9 defines VITC as a 90-bit code word arranged in nine groups of ten bits. Each group starts with a fixed synchronization bit pair, and the last group carries a CRC code for error detection.

VITC is NRZ modulated and inserted on a selected line in the vertical interval. The standard gives the allowed line ranges and preferred lines for 525/59,94 and 625/50 systems, and it says that in analogue component systems the VITC code word is carried in the Y channel. This matters for machine setup because the line choice, signal level, and timing must match the target television system.

LTC and VITC relationship

Clause 10 explains how to move time address and binary group data between LTC and VITC. The basic rule is to transfer the time address one frame ahead so the receiving form stays aligned with the next frame, while keeping drop frame and colour frame information when applicable.

The same clause also gives guidance for transferring binary group data. When the data format allows it, a one-frame update can be used; when it does not, the transfer can produce a one-frame delay. For plants that convert between transports, this is the practical rule that keeps labels and user data consistent.

Progressive systems above 30 fps

Clause 11 adds guidance for 50 and 60 fps progressive systems. Because the time address cannot count every frame individually at those rates, the code increments every other frame, and the VITC field mark flag is used to distinguish the first and second frame of the pair.

What terms does SIST EN 60461:2011 define?

  • Binary coded decimal (BCD) system - A way of encoding decimal digits in groups of binary bits, used for the time address.
  • Frame - A complete picture made from the video lines needed for one image.
  • Field - One of the two interlaced parts of a frame in interlaced video.
  • Linear time code (LTC) - A code word format and modulation system normally used on linear recording media or over a separate interface.
  • Vertical interval time code (VITC) - A code word format and modulation system inserted into an active line in the vertical blanking interval of analogue SDTV.
  • Time and control code - The full system of time address, flag bits, binary groups, and the two modulation methods.
  • Original source - The device that generates the time and control code in sync with its associated video or audio.

Who uses SIST EN 60461:2011?

SIST EN 60461:2011 is used by television, film, and audio system designers, broadcasters, post-production facilities, and equipment manufacturers. It is also relevant to integrators and test engineers who need to generate, decode, transfer, or verify time code.

In practice, users rely on it when they label recorded frames, preserve user data in binary groups, move between LTC and VITC, or align time code with analogue video signals. Quality teams use it to check that equipment handles frame counting, flag bits, CRC protection, and timing tolerances in a compatible way.

What changed in SIST EN 60461:2011 from the previous edition?

SIST EN 60461:2011 supersedes SIST EN 60461:2005 and EN 60461:2001. The significant change stated for this edition is the addition of time code for progressive television systems with a frame rate greater than 30 frames per second.

Which standards are used with SIST EN 60461:2011?

Clause 2 names the standards needed to apply SIST EN 60461:2011 correctly:

  • ISO/IEC 646 - Supplies the 7-bit character set used for eight-bit binary group encoding.
  • ISO/IEC 2022 - Provides character code structure and extension techniques.
  • ITU-R BT.1700-1 - Gives composite video characteristics and supports PAL colour-sequence handling.
  • SMPTE 170M - Defines NTSC composite analogue video characteristics and colour-field references.
  • SMPTE 258M - Covers transfer of edit decision lists and standard frame-based display formats.
  • SMPTE 262M - Defines the page/line multiplex system for binary groups.
  • SMPTE 309M - Defines date and time zone information in binary groups.

The scope note also points to SMPTE 266M for D-VITC and SMPTE 12M-2 for ATC in digital video systems.

What does the SIST EN 60461:2011 document contain?

The document contains detailed bit assignments, timing diagrams, and waveform examples for both LTC and VITC. Tables 1 to 11 map flag meanings, bit positions, synchronization words, and CRC bits, while Figures 1 to 9 illustrate waveforms, code alignment, and progressive-system labeling.

Annex A explains time precision, leap second handling, and how frame duration relates to video and audio systems. Annex B gives worked conversion guidance for moving time codes when converting 24 fps television material to 25 fps or 30 fps systems, including example pull-down cases shown in Figures B.1 and B.2.

Relations

Effective Date
13-May-2010

Buy Documents

Standard

SIST EN 60461:2011

English language (46 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 60461:2011 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Time and control code (IEC 60461:2010)". This standard covers: IEC 60461:2010(E) specifies a digital time and control code for use in television, film, and accompanying audio systems operating at nominal rate of 60, 59, 94, 50, 30, 29, 97, 25, 24 and 23,98 frames per second. This International Standard specifies a time address, binary groups, and flag bit structure. In addition, the standard specifies a binary group flag assignment, a linear time code transport, and a vertical interval time code transport. It cancels and replaces the third edition published in 2001, of which it constitutes a technical revision. It includes the following significant change with regard to the previsous edition: The time code for progressive television systems with a frame rate greater than 30 frames per second is added.

IEC 60461:2010(E) specifies a digital time and control code for use in television, film, and accompanying audio systems operating at nominal rate of 60, 59, 94, 50, 30, 29, 97, 25, 24 and 23,98 frames per second. This International Standard specifies a time address, binary groups, and flag bit structure. In addition, the standard specifies a binary group flag assignment, a linear time code transport, and a vertical interval time code transport. It cancels and replaces the third edition published in 2001, of which it constitutes a technical revision. It includes the following significant change with regard to the previsous edition: The time code for progressive television systems with a frame rate greater than 30 frames per second is added.

SIST EN 60461:2011 is classified under the following ICS (International Classification for Standards) categories: 33.160.40 - Video systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 60461:2011 has the following relationships with other standards: It is inter standard links to SIST EN 60461:2005. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 60461:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and reserved
  • 3.1 Terms and definitions
  • 3.1.1 binary coded decimal system
  • 3.1.2 frame
  • 3.1.3 field
  • 3.1.4 linear time code
  • 3.1.5 vertical interval time code
  • 3.1.6 time and control code
  • 3.1.7 time code source
  • 3.1.8 original source
  • 3.2 Reserved
  • 4 Time representation in 30 frames per second and 60 frames per second
  • 4.1 Definitions of real time and NTSC time
  • 4.2 Time address of a frame
  • 4.3 Colour frame identification in NTSC analogue composite television systems
  • 5 Time representation in 25 frames per second and 50 frames per second
  • 5.1 Definition of real time
  • 5.2 Time address of a frame
  • 5.3 Colour frame identification in PAL analogue composite television systems
  • 6 Time representation in 24-frame systems
  • 6.1 Definitions of real time and NTSC time
  • 6.2 Time address of a frame
  • 7 Structure of the time address and control bits
  • 7.1 Numeric code
  • 7.2 Time address
  • 7.3 Flag bits
  • 7.4 Use of the binary groups
  • 7.5 Clock time reference – Binary group flag combinations
  • 8 Linear time code application
  • 8.1 Code word format
  • 8.2 Code word data content
  • 8.3 Modulation method
  • 8.4 Bit rate
  • 8.5 Timing of the code word relative to a television signal
  • 8.6 Linear time code interface electrical and mechanical characteristics
  • 2 MSB
  • 9 Vertical interval application – Analogue television systems
  • 9.1 Code word format
  • 9.2 Code word data content
  • 9.3 Modulation method
  • 9.4 Bit timing
  • 9.5 Timing of the code word relative to the television signal
  • 9.6 Location of the address code signal in the vertical interval
  • 9.7 Redundancy
  • 9.8 Vertical interval time code waveform characteristics
  • 10 Relationship between LTC and VITC
  • 10.1 Time address data
  • 10.2 Binary group data
  • 10.3 VITC and LTC code word comparison
  • 11 Progressive systems with frame rates greater than 30 frames per second
  • 11.1 Time address of a frame pair in 50 and 60 frames per second progressive systems
  • 11.2 Implementation guidelines
  • Annex A
  • Annex B
  • Bibliography

INTRODUCTION IEC 60461 was originally developed for analogue television recording systems and thus dealt only with interlaced television systems operating with frame rates up to 30 frames per second. It is, however, flexible enough in design to be used in digital television systems, both standard definition and high definition. The support for progressive video systems with frame rates above 30 frames per second is described in this International Standard. Clauses 4, 5, and 6 specify the manner in which time is represented in frame-based systems. Clause 7 specifies the structure of the time address and control bits of the code, and sets guidelines for storage of user data in the code. Clause 8 specifies the modulation method and interface characteristics of a linear time code (LTC) source. Clause 9 specifies the modulation method for inserting the code into the vertical interval of a television signal. Clause 10 summarises the relationship between the two forms of time and control code. Clause 11 summarises time code implementations for video formats with frame rates greater than 30 fps.

SIST EN 60461:2011

TIME AND CONTROL CODE

1 Scope

This International Standard specifies a digital time and control code for use in television, film, and accompanying audio systems operating at nominal rate of 60, 59,94, 50, 30, 29,97, 25, 24 and 23,98 frames per second. This International Standard specifies a time address, binary groups, and flag bit structure. In addition, the standard specifies a binary group flag assignment, a linear time code transport, and a vertical interval time code transport. This International Standard defines primary data transport structures for linear time code (LTC) and vertical interval time code (VITC). This standard specifies the LTC modulation and timing for all video formats. This standard also defines the VITC modulation and location for 525/59,94 and 625/50 analogue composite and component systems only. NOTE The digital representation of analogue VITC (D-VITC) is specified in SMPTE 266M and is defined for 525/59,94 and 625/50 digital component systems only. High definition formats, such as those documented in SMPTE 274M and SMPTE 296M, should use ancillary time code (ATC) as specified in SMPTE 12M-2 (formerly SMPTE RP 188) for transport of time code in the digital video data stream. For future implementations of time code for digital standard definition formats, the use of ATC rather than D-VITC is encouraged.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

ISO/IEC 646:1991, Information processing – ISO 7-bit coded character set for information interchange ISO/IEC 2022:1994, Information technology – Character code structure and extension techniques ITU-R BT.1700-1(2005), Annex 2, Characteristics of composite video signals for conventional analogue television systems SMPTE 170M:2004, Television – Composite Analog Video Signal – NTSC for Studio Applications SMPTE 258M:1993, Television – Transfer of Edit Decision Lists SMPTE 262M:1995, Television, Audio and Film – Binary Groups of Time and Control Codes – Storage and Transmission of Data SMPTE 309M:1999, Television – Transmission of Date and Time Zone Information in Binary Groups of Time and Control Code

3 Terms, definitions and reserved

3.1 Terms and definitions

For the purposes of this document the following terms and definitions apply.

SIST EN 60461:2011

3.1.1 binary coded decimal system

BCD system means for encoding decimal numbers as groups of binary bits NOTE 1 Each decimal digit (0-9) is represented by a unique four-bit code. The four bits are weighted with the digit's decimal weight multiplied by successive powers of two. 0 1 2 3 NOTE 2 For example, the bit weights for a "units" digit would be 1 × 2 , 1 × 2 , 1 × 2 , and 1 × 2 , while the bit 0 1 2 3 weights for a "tens" digit would be 10 × 2 , 10 × 2 , 10 × 2 , and 10 × 2 .

3.1.2 frame

contains all of the lines of spatial information of a video signal required to make up one complete picture (including any necessary associated synchronization lines) NOTE For progressive video, these lines contain picture samples, captured at one time instant, starting from the top of the frame and continuing through successive lines to the bottom of the frame.

3.1.3 field

frame consists of two fields for interlaced video: one of these fields will commence one field period later than the other NOTE See SMPTE 170M for an example of such a system. Composite television standards might require multiple fields in a “colour sequence,” but that does not alter this standard’s nominal terminology.

3.1.4 linear time code

LTC code word format and modulation system which is normally used to record the time code signal on a linear recording medium or to transport the serial signal over an interface independent of any video signal

3.1.5 vertical interval time code

VITC code word format and modulation system used to insert the time code signal in an active line within the vertical blanking interval of an analogue standard definition television (SDTV) signal

3.1.6 time and control code

encompasses all aspects of the time address, flag bits, and binary groups for user-defined data codes, as well as two methods of modulation of the resulting code words NOTE It is commonly abbreviated as “time code” (note also that some users spell this “timecode”).

3.1.7 time code source

any device which generates a time and control code signal, or regenerates a time and control code signal from a recorded medium or transmission channel

3.1.8 original source

refers specifically to a device which is generating the time and control code signal in synchronization with its associated video and/or audio NOTE The time address and binary group (“user data”) payload is attached to a particular frame or frame pairs either directly or by reference within the user’s system. For frame-based systems the time address that forms part of the time code is primarily intended as a label to identify discrete frames. It also may imply that a particular frame

SIST EN 60461:2011

has had, has now, or will have, a temporal relationship to something else, such as the frame's position in a sequence of frames or synchronization to a reference signal.

3.2 Reserved

Indicates a provision that it is not defined at this time, shall not be used, and may be defined in future.

4 Time representation in 30 frames per second and 60 frames per second

systems

4.1 Definitions of real time and NTSC time

4.1.1 Definition of real time

In a system running at a frame rate of 30 frames per second (fps), exactly one second of real time elapses during the scanning of 30 frames. In a system operating at a frame rate of 60 fps, exactly one second of real time elapses during the duration of 60 frames.

4.1.2 Definition of NTSC time

In an NTSC television system operating at a vertical field rate of 60/1,001 fields per second (≈59,94 Hz), one second of NTSC time elapses during the scanning of 60 television fields or 30 television frames. Because of the difference in vertical scanning rates, the relationship between real time and NTSC time is 1 s = 1,001 s

NTSC REAL NOTE 1 There are other television systems (such as some HDTV systems) which operate at 24/1,001, 30/1,001, or 60/1,001 frames per second. The term “NTSC time” is used to indicate its historical origins and to describe the common frame time base of all of these systems.

NOTE 2 The results of dividing the integer frame rates by 1,001 do not result in precise decimal numbers, for example, 30/1,001 is 29,970 029 970 029... (to 12 decimals). This is commonly abbreviated as 29,97. In a similar manner, it is common to abbreviate 24/1,001 as 23,98, and 60/1,001 as 59,94. These abbreviations are used throughout this standard. Sufficient precision is necessary in calculations to assure that rounding or truncation operations will not create errors in the end result. This is particularly important when calculating audio sample alignments or when long-term time keeping is required.

4.2 Time address of a frame

4.2.1 Definition of time address of a frame

Each frame shall be identified by a unique and complete address consisting of an hour, minute, second, and frame number. For systems operating at 60 frames per second, each frame pair shall be identified by a unique and complete address consisting of an hour, minute, second, and frame number. Refer to SMPTE 258M for standard formats used to display frame-based time.

The hours, minutes, and seconds follow the ascending progression of a 24-hour clock beginning with 0 hours, 0 minutes, and 0 seconds to 23 hours, 59 minutes, and 59 seconds. The frames shall be numbered successively according to the counting mode (drop frame or non-drop frame) as described below:

NOTE See Clause 11 for additional information regarding television systems which operate at 60 frames per second.

SIST EN 60461:2011

4.2.2 Non-drop frame – Uncompensated mode

Frames shall be numbered 0 through 29, successively, with no omissions.

4.2.3 Drop frame – NTSC time compensated mode

Because the vertical field rate of an NTSC television signal is 60/1,001 fields per second (≈59,94 Hz), straightforward counting at 30 frames per second will yield an error of approximately +108 frames (+3,6 s) in one hour of running time. REAL To minimize the NTSC time error, the first two frame numbers (00 and 01) shall be omitted from the count at the start of each minute except minutes 00, 10, 20, 30, 40, and 50. Because the frame rate of a progressive NTSC-time related 60 frames per second television signal is actually 60/1,001 frames per second, and each time code count references a frame pair, the same counting mechanism may be applied as well. See Clause 11 for additional information on this subject.

When drop-frame compensation is applied to an NTSC television time code, the total error accumulated after one hour is reduced to –3,6 ms. The total error accumulated over a 24-hour period is –86 ms.

4.3 Colour frame identification in NTSC analogue composite television systems

If colour frame identification in the time code is required, the even units of frame numbers shall identify colour fields I and II, and the odd units of frame numbers shall identify colour fields III and IV.

NOTE Even though a component system does not have a colour sequence, the time code may carry colour sequence information from an original video source so that recoding of a composite signal into a component signal and back can preserve the original colour sequence relationship.

5 Time representation in 25 frames per second and 50 frames per second

systems

5.1 Definition of real time

In a system running at a frame rate of 25 frames per second, exactly one second of real time elapses during the scanning of 25 frames. An example of such a system is a 625/50 television system. In a system running at a frame rate of 50 frames per second, exactly one second of real time elapses during the duration of 50 frames.

5.2 Time address of a frame

Each frame shall be identified by a unique and complete address consisting of an hour, minute, second, and frame number. For systems operating at 50 frames per second, each frame pair shall be identified by a unique and complete address consisting of an hour, minute, second, and frame number.

The hours, minutes, and seconds follow the ascending progression of a 24-hour clock beginning with 0 hours, 0 minutes, and 0 seconds to 23 hours, 59 minutes, and 59 seconds. The frames (or frame pairs for 50 frames per second systems) shall be numbered successively 0 through 24.

There is no counting mode such as drop frame (which is applicable only to 30 frame counting) that is applicable to 25 frame counting.

SIST EN 60461:2011

NOTE See Clause 11 for additional information regarding television systems which operate at frame rates of 50 frames per second.

5.3 Colour frame identification in PAL analogue composite television systems

5.3.1 Colour frame identification

If identification of the eight-field colour sequence in the time code is required, the time address shall bear a predictable relationship with the eight-field colour sequence (as specified in ITU-R BT.1700). This relationship can be expressed using either logical or arithmetic notations as 5.3.2 and 5.3.3, r es pec tively.

given in

5.3.2 Logical relationship

Given that the frame and second numbers of the time address are expressed as BCD digit pairs, the value of the logical expression (A|B) ^ C ^ D ^ E ^ F shall be:

"1" for fields 1, 2, 3, and 4; "0" for fields 5, 6, 7, and 8 where A equals the value of the 1's bit of the frame number; B equals the value of the 1's bit of the second number; C equals the value of the 2's bit of the frame number; D equals the value of the 10's bit of the frame number; E equals the value of the 2's bit of the second number; F equals the value of the 10's bit of the second number; | represents the logical OR operation; ^ represents the logical EXCLUSIVE OR operation.

5.3.3 Arithmetic relationship

The remainder of the quotient:

(S +P)

shall be 0 for fields 7 and 8; 1 for fields 1 and 2; 2 for fields 3 and 4; 3 for fields 5 and 6 where S equals the decimal value of the "seconds" digits of the time address, and P equals the decimal value of the frames digits of the time address.

6 Time representation in 24-frame systems

6.1 Definitions of real time and NTSC time

6.1.1 Definition of real time

In a system running at a frame rate of 24 frames per second, exactly one second of real time elapses during the passing of 24 frames. An example of such a system is a film system.

SIST EN 60461:2011

6.1.2 Definition of NTSC time

In a NTSC-time related television signal operating at 24/1,001 frames per second (approximately 23,976), straightforward counting at 24 frames per second will yield a deviation of approximately 86 frames (3,6 s) in one hour of elapsed time. Where it is desired to maintain a correspondence with 30 frame per second systems the 30 non-drop frame count mode should be used. For additional details refer to Annex B.1.

6.2 Time address of a frame

Each frame shall be identified by a unique and complete address consisting of an hour, minute, second, and frame number. The hours, minutes, and seconds follow the ascending progression of a 24 hour clock beginning with 0 hours, 0 minutes, and 0 seconds to 23 hours, 59 minutes, and 59 seconds. The frames shall be numbered successively 0 through 23. There is no counting mode such as drop frame (which is applicable only to 30 frame counting) that is applicable to 24 frame counting.

7 Structure of the time address and control bits

7.1 Numeric code

The numeric code consists of sixteen four-bit groups, eight groups containing time address and flag bits, and eight four-bit binary groups for user-defined data and control codes.

7.2 Time address

The basic structure of the time address is based upon the BCD system, using units and tens in digit pairs for hours, minutes, seconds, and frames. Some of the digits are limited to values that do not require all four bits to be significant. These bits are omitted from the time address and include the "80s" and "40s" of hours, "80s" of minutes, "80s" of seconds, and the "80s" and "40s" of frames. Thus the entire time address is coded into 26 bits.

7.3 Flag bits

7.3.1 Definition of flag bits

Six bits are reserved for the storage of flags which define the operational mode of the time and control code. A device which decodes a time and control code may utilize these flags to interpret properly the time address and binary group data.

7.3.2 Drop frame flag (NTSC composite television system only)

This flag shall be set to 1 when drop frame compensation is being performed as specified in 4.2.3. When the count is not drop frame compensated, this flag bit shall be set to 0.

7.3.3 Colour frame flag (NTSC and PAL composite television systems only)

If colour frame identification has intentionally been applied to the time and control code by the original source, as defined in 4.3 or 5.3, this flag shall be set to 1. If this flag is set to logical zero then there is no implied relationship between the colour frame sequence and the time address.

NOTE Colour frame identification may be forced by an original source of time and control code by halting the time address until the colour field to time code relationship is satisfied, after which the time address is incremented normally each frame. As long as neither the time address counting sequence nor the colour field sequence is changed, the relationship will remain satisfied.

SIST EN 60461:2011

7.3.4 Binary group flags

Three flags provide eight unique combinations which specify the use of the binary groups (see 7.4). Three combinations of these flags also specify the time address reference as an external precision clock time reference (see 7.5) and these also select subsets of the binary group applications.

NOTE The term binary group flags represents its historical origins, however these flags now also signal time address count parameters.

7.3.5 Modulation method specific flag

The remaining flag bit is reserved for use by each modulation method. This flag is defined in 8.2.6 and 9.2.5.

7.4 Use of the binary groups

7.4.1 Binary group flag assignments

The binary groups are intended for storage and transmission of data by the users. The format of the data contained in the binary groups is specified by the value of three binary group flag bits BGF2, BGF1, and BGF0. The following subclauses define the current assignments of the binary group flag states. Table 1 summarises the present assigned combinations. NOTE The binary groups are commonly referred to as "user bits" Table 1 – Binary group flag assignments BGF2 BGF1 BGF0 Time address Binary group Reference 0 0 0 Unspecified Unspecified 7. 4. 2 0 0 1 Unspecified 8-bit codes 7. 4. 3 1 0 0 Unspecified Date and time zone 7. 4. 4 1 0 1 Unspecified Page/line 7. 4. 5 0 1 0 Clock time Unspecified 7. 4. 6, 7. 5 0 1 1 Unassigned Reserved 7. 4. 7 1 1 0 Clock time Date and time zone 7. 4. 8, 7. 5 1 1 1 Clock time Page/line 7. 4. 9, 7. 5

7.4.2 Character set not specified and unspecified clock time

(BGF2=0, BGF1=0, BGF0=0) This combination of binary group flags signifies that the time address is not referenced to an external clock and that the binary groups contain an unspecified character set. If the character set used for the data insertion is unspecified, the 32 bits within the eight binary groups may be assigned in any manner without restriction.

7.4.3 Eight-bit character set and unspecified clock time

(BGF2=0, BGF1=0, BGF0=1) This combination signifies that the time address is not referenced to an external clock and that the binary groups contain an eight-bit character set conforming to ISO/IEC 646 or ISO/IEC 2022. If the seven-bit ISO codes are being used, they shall be converted to eight-bit codes by setting the eighth bit to 0.

SIST EN 60461:2011

Four ISO codes may be encoded in the binary groups, each occupying two binary groups. The first ISO code is contained in binary groups 7 and 8, with the least significant four bits in binary group 7 and the most significant four bits in binary group 8. The three remaining ISO codes are stored in binary groups 5/6, 3/4, and 1/2 accordingly.

...