SIST EN 300 220-2 V1.2.1:2003
(Main)ElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Short range devices; Technical characteristics and test methods for radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 2: Supplementary parameters not intended for regulatory purposes
- Abstract
Revision and upgrade to EN of I-ETS 300 220 (8/93). Covers a wide range of telecommand, telemetry and generic non-speech applications, such as alarm systems, identification, detection, remote control etc. in the frequency band 25-1000 MHz, including European ISM bands. Additional aspects related to the radio characteristics of equipment to be used in social alarm systems, to ensure adequate reliability for the purposes of CENELEC TC79 standardization in this field.
- Status
- Published
- Publication Date
- 30-Nov-2003
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Dec-2003
- Due Date
- 01-Dec-2003
- Completion Date
- 01-Dec-2003
- Mandate
- T-353
SIST EN 300 220-2 V1.2.1:2003 is the Slovenian adoption of ETSI EN 300 220-2 V1.2.1, a European Telecommunications Standard for short range devices. It covers supplementary technical characteristics and test methods for radio equipment operating from 25 MHz to 1 000 MHz with power levels up to 500 mW. The document is aimed at manufacturers, test labs, and users who need receiver performance guidance, especially for alarms, identification, telecommand, telemetry, and related non-speech applications.
What does SIST EN 300 220-2 V1.2.1:2003 specify?
SIST EN 300 220-2 V1.2.1:2003 specifies supplementary parameters for short range devices, not parameters intended for regulatory purposes. In practice, it tells you how to judge receiver performance and what minimum receiver characteristics are expected for reasonable link reliability.
The scope covers equipment with an RF output connection and/or an integral antenna, and it applies to fixed, mobile, and portable stations. It also notes that the document is a product family standard, so specific application standards may add more requirements.
| Annex | What it covers |
|---|---|
| Annex A | Social alarm systems, including minimum effective radiated power and related receiver parameters |
The document is organized into scope, normative references, definitions/symbols/abbreviations, receiver parameters, and Annex A for social alarm systems.
What are the key requirements of SIST EN 300 220-2 V1.2.1:2003?
The core of SIST EN 300 220-2 V1.2.1:2003 is clause 4, which sets receiver performance limits and the test concepts behind them. These are the figures that matter when you design, select, or evaluate SRD receivers.
Receiver sensitivity and usable signal level
Clause 4.1 defines maximum usable sensitivity for conducted tests. The receiver is assessed with a carrier at the nominal frequency and normal test signal modulation, and the output must meet one of the stated quality criteria: SND/ND performance, bit error ratio, or message acceptance ratio. In practice, this tells you the weakest input signal the receiver must still handle.
Clause 4.2 covers average usable sensitivity for equipment with an integral or dedicated antenna. The measurement uses multiple receiver orientations, which matters because antenna position affects real-world performance. The limits vary by frequency band and by antenna arrangement, so you need to match the test setup to the product design.
Receiver selectivity and interference resistance
Clause 4.3 sets co-channel rejection, which checks how well the receiver handles an unwanted signal on the same channel. Clause 4.4 sets adjacent channel selectivity, which checks performance against signals on neighboring channels. For users, these requirements show whether the receiver can survive dense radio environments without losing the wanted link.
Clauses 4.5 to 4.7 cover spurious response rejection, intermodulation response rejection, and blocking or desensitization. These tests check behavior when strong unwanted signals are present away from the wanted channel. In practice, they are the main indicators of how robust the receiver is near other transmitters.
Social alarm systems
Annex A applies to social alarm systems in domestic or residential environments. It covers fixed, mobile, or portable transmitters working into fixed receivers, and it takes building losses, reflections, antenna patterns, and a typical distance into account. It also classifies effective radiated power into four levels and ties receiver requirements back to clause 4, so it is the part to consult when the application is personal safety or assistance alarms.
What terms does SIST EN 300 220-2 V1.2.1:2003 define?
- alarm - radio communication used to indicate an alarm condition at a distant location.
- conducted measurements - measurements made through a direct 50 ohm connection to the equipment under test.
- dedicated antenna - a removable antenna supplied and type tested with the radio equipment as an indispensable part of it.
- integral antenna - a permanent fixed antenna built into the equipment as an indispensable part of it.
- fixed station - equipment intended for use in one fixed location.
- portable station - equipment intended to be carried, attached, or implanted.
- telecommand - radio communication used to start, change, or stop equipment functions at a distance.
- telemetry - radio communication used to indicate or record data at a distance.
Who uses SIST EN 300 220-2 V1.2.1:2003?
SIST EN 300 220-2 V1.2.1:2003 is used by radio equipment manufacturers, test laboratories, and compliance engineers working on SRD products. It is also relevant to buyers and technical evaluators who need to compare receiver performance across alarms, identification devices, remote control equipment, and telemetry systems. Annex A is especially relevant to designers of social alarm systems.
What changed in SIST EN 300 220-2 V1.2.1:2003 from the previous edition?
SIST EN 300 220-2 V1.2.1:2003 is identified in the document history as the version published after ETS 300 220-2 edition 2 and the earlier 1993 edition. The foreword states that this part specifies supplementary parameters not intended for regulatory purposes and that Annex A provides specifications concerning social alarm systems.
Which standards are used with SIST EN 300 220-2 V1.2.1:2003?
- CEPT/ERC Recommendation 70-03 - gives the SRD frequency use framework referenced by the scope.
- ETS 300 113 - provides receiver measurement conditions for equipment with an antenna connector.
- ETS 300 390 - provides receiver measurement conditions for equipment using an integral antenna.
- ITU-T Recommendation 0.41 - defines the psophometric weighting network used in the SND/ND measurement.
- EN 300 220-1 - gives the spectrum-utilization requirements and the measurement method for ERP used in Annex A.
What does the SIST EN 300 220-2 V1.2.1:2003 document contain?
The document contains receiver test definitions, limit statements, and cross-references to measurement methods in related ETS standards. Table 1 gives average usable sensitivity limits by frequency range and antenna arrangement, while table 2 sets the adjacent-channel test conditions. Clause 4 also includes the formulas and procedures used to evaluate sensitivity and rejection performance. Annex A adds an application-specific power classification for social alarm systems and points readers to EN 300 220-1 for ERP measurement.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 300 220-2 V1.2.1:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "ElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Short range devices; Technical characteristics and test methods for radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 2: Supplementary parameters not intended for regulatory purposes". This standard covers: Revision and upgrade to EN of I-ETS 300 220 (8/93). Covers a wide range of telecommand, telemetry and generic non-speech applications, such as alarm systems, identification, detection, remote control etc. in the frequency band 25-1000 MHz, including European ISM bands. Additional aspects related to the radio characteristics of equipment to be used in social alarm systems, to ensure adequate reliability for the purposes of CENELEC TC79 standardization in this field.
Revision and upgrade to EN of I-ETS 300 220 (8/93). Covers a wide range of telecommand, telemetry and generic non-speech applications, such as alarm systems, identification, detection, remote control etc. in the frequency band 25-1000 MHz, including European ISM bands. Additional aspects related to the radio characteristics of equipment to be used in social alarm systems, to ensure adequate reliability for the purposes of CENELEC TC79 standardization in this field.
SIST EN 300 220-2 V1.2.1:2003 is classified under the following ICS (International Classification for Standards) categories: 33.060.20 - Receiving and transmitting equipment; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 220-2 V1.2.1:2003 is associated with the following European legislation: Standardization Mandates: T-353. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 300 220-2 V1.2.1:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.UHJXODWLYHElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Short range devices; Technical characteristics and test methods for radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 2: Supplementary parameters not intended for regulatory purposes33.100.01Elektromagnetna združljivost na splošnoElectromagnetic compatibility in general33.060.20Sprejemna in oddajna opremaReceiving and transmitting equipmentICS:Ta slovenski standard je istoveten z:EN 300 220-2 Version 1.2.1SIST EN 300 220-2 V1.2.1:2003en01-december-2003SIST EN 300 220-2 V1.2.1:2003SLOVENSKI
STANDARD
European Telecommunications Standards Institute EN 300 220-2 V1.2.1 (1997-11)European Standard (Telecommunications series)Electromagnetic compatibility andRadio spectrum Matters (ERM);Short range devices;Technical characteristics and test methods for radioequipment to be used in the 25 MHz to 1 000 MHz frequencyrange with power levels ranging up to 500 mW;Part 2: Supplementary parametersnot intended for regulatory purposesSIST EN 300 220-2 V1.2.1:2003
EN 300 220-2 V1.2.1 (1997-11)2ReferenceREN/ERM-RP08-0107-2 (21ci0ioo.PDF)formerly REN/RES-08-0107-2KeywordsRadio, testing, SRDETSI SecretariatPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88X.400c= fr; a=atlas; p=etsi; s=secretariatInternetsecretariat@etsi.frhttp://www.etsi.frCopyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1997.All rights reserved.SIST EN 300 220-2 V1.2.1:2003
EN 300 220-2 V1.2.1 (1997-11)3ContentsIntellectual Property Rights.4Foreword.41Scope.52Normative references.53Definitions, symbol and abbreviations.63.1Definitions.63.2Symbol.63.3Abbreviations.64Receiver parameters.74.1Maximum usable sensitivity (conducted).74.1.1Definition.74.1.2Limits.74.2Average usable sensitivity (field strength).74.2.1Definition.74.2.2Limits.74.3Co-channel rejection.84.3.1Definition.84.3.2Limits.84.4Adjacent channel selectivity.84.4.1Definition.84.4.2Limits.84.5Spurious response rejection.94.5.1Definition.94.5.2Limits.94.6Intermodulation response rejection.94.6.1Definition.94.6.2Limits.94.7Blocking or desensitization.94.7.1Definition.94.7.2Limits.9Annex A (normative):Application: Social alarm systems.10A.1General.10A.2Minimum effective radiated power.10A.2.1Definition.10A.2.2Method of measurement.10A.2.3Classification of effective radiated power levels.10A.3Receiver parameters.11History.12SIST EN 300 220-2 V1.2.1:2003
EN 300 220-2 V1.2.1 (1997-11)4Intellectual Property RightsETSI has not been informed of the existence of any Intellectual Property Right (IPR) which could be, or could becomeessential to the present document. However, pursuant to the ETSI Interim IPR Policy, no investigation, including IPRsearches, has been carried out. No guarantee can be given as to the existence of any IPRs which are, or may be, or maybecome, essential to the present document.ForewordThis European Standard (Telecommunications series) has been produced by ETSI Technical CommitteeElectromagnetic compatibility and Radio spectrum matters (ERM).The technical parameters which are relevant to the EMC Directive are listed in annex B.The present document consists of two parts as follows:Part 1:"Parameters intended for regulatory purposes";Part 2:"Supplementary parameters not intended for regulatory purposes".This part specifies supplementary parameters for specific applications not related to effective use of the spectrum.Annex A provides specifications concerning social alarm systems.National transposition datesDate of adoption of this EN:24 October 1997Date of latest announcement of this EN (doa):28 February 1998Date of latest publication of new National Standardor endorsement of this EN (dop/e):31 August 1998Date of withdrawal of any conflicting National Standard (dow):31 August 1998SIST EN 300 220-2 V1.2.1:2003
EN 300 220-2 V1.2.1 (1997-11)51ScopeThe present document covers the minimum characteristics considered necessary for Short Range Devices (SRD) in orderto make the best use of the available frequencies. The term "The present document" refers to EN 300 220-2 only.These parameters specified in this part are not intended to be measured for regulatory purposes. However, they are providedto give guidance to manufacturers and users regarding reasonable reliability of the radio link and performance of thereceiver.The present document contains the technical characteristics for radio equipment referencing relevant CEPT/ERCDecisions and Recommendation CEPT ERC/Recommendation 70-03 [1].The present document does not necessarily include all the characteristics which may be required by a user, nor does itnecessarily represent the optimum performance achievable. It is a product family standard which may be completely orpartially superseded by specific standards covering specific applications.The present document applies to short range devices:-either with a Radio Frequency (RF) output connection and/or with an integral antenna;-for alarms, identification, telecommand, telemetry, etc., applications;-with or without speech;-operating on radio frequencies between 25 MHz and 1 000 MHz, with power levels up to 500 mW, radiated orconducted.The present document covers fixed stations, mobile stations and portable stations. In the present document basicrequirements
...