SIST EN 13905:2004
(Main)Low resistance shower hoses for sanitary tapware
Low resistance shower hoses for sanitary tapware
This European Standard specifies :
- the dimensional, leaktightness, mechanical and hydraulic characteristics with which shower hoses shall comply ;
- the procedures for testing these characteristics.
It applies to shower hoses of any material used for ablutionary purposes and intended for connecting shower handsets to the sanitary tapware of baths and showers. They should only be connected downstream of the obturator of the tapware.
Details of pressure and temperature are given in Table 1.
Table 1 - Conditions of use
Limits of use Recommended limits for correct operation
Dynamic pressure 0,01 L P L 0,2 MPa
(0,1 L P L 2 bar) 0,02 L P L 0,1 MPa
(0,2 L P L 1,0 bar)
Temperature T L 70 °C T L 42 °C
Hoses which are an integral part of sanitary tapware (e.g. sink mixers) or hoses intended to connect sanitary tapware to the water supplies are not covered by this standard.
Brauseschläuche für Sanitärarmaturen mit geringem Durchflusswiderstand
Diese Europäische Norm legt Folgendes fest:
- die Maße, die Anforderungen an die Dichtheit, die mechanischen und hydraulischen Anforderungen, denen Brauseschläuche entsprechen müssen,
- die Prüfverfahren, um diese Anforderungen zu überprüfen.
Sie gilt unabhängig vom verwendeten Material für Brauseschläuche zur Verbindung von Handbrausen für die Körperhygiene als Ausrüstung von Sanitärarmaturen in Bädern und Duschen. Sie sollten nur hinter dem Absperrorgan der Sanitärarmatur angeschlossen werden.
Druck- und Temperaturangaben sind in Tabelle 1 enthalten.
Tabelle 1 - Anwendungsbereich
Grenzen der Anwendung Empfohlener Bereich
der Anwendung
Fließdruck 0,01 MPa L P L 0,2 MPa 0,02 MPa L P L 0,1 MPa
(0,1 bar L P L 2,0 bar) (0,2 bar L P L 1,0 bar)
Temperatur T L 70 °C T L 42 °C
Diese Norm gilt nicht für Schläuche zur Verbindung der Armaturen mit der Installation und Schläuche, die integraler Bestandteil der Sanitärarmatur sind (z. B. Küchenmischer).
Flexibles de douches basse pression pour robinetterie sanitaire
La présente Norme européenne spécifie :
3 les caractéristiques dimensionnelles, d'étanchéité, de comportement mécanique et hydraulique auxquelles doivent répondre les flexibles de douches ;
3 les modes opératoires d'essai permettant de contrôler ces caractéristiques.
Elle s'applique aux flexibles de douches, quel que soit le matériau utilisé, destinés a raccorder les douchettes aux robinetteries sanitaires de baignoires ou de douches réservées pour l'hygiene corporelle. Il convient qu'ils ne soient raccordés qu'en aval de l'obturateur de la robinetterie.
Les exigences relatives a la pression et a la température sont données dans le Tableau 1.
Tableau 1 - Conditions d'utilisation
Limites d'utilisation Limites recommandées pour un bon fonctionnement
Pression dynamique 0,01 L P L 0,2 MPa
(0,1 L P L 2 bar) 0,02 L P L 0,1 MPa
(0,2 L P L 1,0 bar)
Température T L 70 °C T L 42 °C
Les flexibles destinés a raccorder les robinetteries sanitaires a l'installation, ainsi que ceux qui font partie de la robinetterie (par exemple, flexibles de douchettes d'évier) ne sont pas couverts par cette norme.
Cevi za sanitarne armature z majhnim notranjim pretočnim uporom
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Brauseschläuche für Sanitärarmaturen mit geringem DurchflusswiderstandFlexibles de douches basse pression pour robinetterie sanitaireLow resistance shower hoses for sanitary tapware91.140.70Sanitarne napraveSanitary installationsICS:Ta slovenski standard je istoveten z:EN 13905:2003SIST EN 13905:2004en01-maj-2004SIST EN 13905:2004SLOVENSKI
STANDARD
SIST EN 13905:2004
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13905September 2003ICS 91.140.70English versionLow resistance shower hoses for sanitary tapwareFlexibles de douches basse pression pour robinetteriesanitaireBrauseschläuche für Sanitärarmaturen mit geringemDurchflusswiderstandThis European Standard was approved by CEN on 1 August 2003.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and UnitedKingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2003 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13905:2003 ESIST EN 13905:2004
EN 13905:2003(E)2ContentspageForeword.31Scope.52Normative references.53Terms and definitions.54Designation.65Marking.66Materials.66.1Chemical and hygiene requirements.66.2Exposed surface condition and quality of coating.67Dimensional characteristics.67.1General.67.2Connecting dimensions.77.3Special cases.88Hydraulic characteristics.88.1General.88.2Test method.89Mechanical and leaktightness characteristics.109.1General.109.2Tensile strength.109.3Pressure resistance at elevated temperature.119.4Flexing durability test.139.5Thermal shock test.1510Rotary connection.1610.1General.1610.2Test method.16Annex A (informative)
Low resistance fittings.18Bibliography.20SIST EN 13905:2004
EN 13905:2003(E)3ForewordThis document (EN 13905:2003) has been prepared by Technical Committee CEN/TC 164 “Water supply”,the secretariat of which is held by AFNOR.This European Standard shall be given the status of a national standard, either by publication of an identicaltext or by endorsement, at the latest by March 2004, and conflicting national standards shall be withdrawn atthe latest by March 2004.Annex A is informative.This document includes a Bibliography.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark,Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands,Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and the United Kingdom.SIST EN 13905:2004
EN 13905:2003(E)4IntroductionIn respect of potential adverse effects on the quality of water intended for human consumption caused by theproduct covered by this standard:1) This standard provides no information as to whether the product may be used without restriction inany of the Member States of the EU or EFTA.2) It should be noted that, while awaiting the adoption of verifiable European criteria, existing nationalregulations concerning the use and/or the characteristics of this product remain in force.This European Standard specifies requirements for "low resistance" shower hoses suitable for use in lowpressure water supply systems as described in informative annex A.Requirements for shower hoses suitable for use in high pressure water supply systems are specified in EN1113.SIST EN 13905:2004
EN 13905:2003(E)51 ScopeThis European Standard specifies :¾ the dimensional, leaktightness, mechanical and hydraulic characteristics with which shower hoses shallcomply ;¾ the procedures for testing these characteristics.It applies to shower hoses of any material used for ablutionary purposes and intended for connecting showerhandsets to the sanitary tapware of baths and showers. They should only be connected downstream of theobturator of the tapware.Details of pressure and temperature are given in Table 1.Table 1 — Conditions of useLimits of useRecommended limits for correctoperationDynamic pressure0,01 £ P £ 0,2 MPa(0,1 £ P £ 2 bar)0,02 £ P £ 0,1 MPa(0,2 £ P £ 1,0 bar)TemperatureT £ 70 °CT £ 42 °CHoses which are an integral part of sanitary tapware (e.g. sink mixers) or hoses intended to connect sanitarytapware to the water supplies are not covered by this standard.2 Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications.These normative references are cited at the appropriate places in the text, and the publications are listedhereafter. For dated references, subsequent amendments to or revisions of any of these publications apply tothis European Standard only when incorporated in it by amendment or revision. For undated references thelatest edition of the publication referred to applies (including amendments).EN 248 Sanitary tapware - General specification for electrodeposited coatings of Ni-Cr.ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions,tolerances and designation.3 Terms and definitionsFor the purposes of this European Standard, the following terms and definitions apply.3.1shower hoseflexible supply pipe which connects sanitary tapware to a shower handsetSIST EN 13905:2004
EN 13905:2003(E)64 DesignationHoses complying with this standard, are designated by :¾ the connecting thread dimensions G 1/2 ´ G 1/2 or G 1/2 ´ G 3/4 ;¾ the length ;¾ the material of the external sheath (plastic, metal) ;¾ the type of nuts and if conical the dimension C ;¾ reference to this standard EN 13905 ;¾ flow rate Class (see 8.2.4).EXAMPLEShower hose G 1/2, cone 26 ´ G 3/4, length 1,5 m, metal sheath, EN 13905, Class H.5 MarkingHoses complying with this standard shall be marked permanently and legibly with the manufacturer's mark orthe supplier's mark.The designation shall appear on the packaging.6 Materials6.1 Chemical and hygiene requirementsAll materials coming into contact with water intended for human consumption shall not present any health riskup to a temperature of 90 °C. They shall not cause any deterioration to the water intended for humanconsumption in terms of quality, appearance, smell or taste.Within the recommended limits for correct operation given in clause 1 of this standard the materials shall notundergo any change which would impair the performance of the hose. Parts subjected to pressure shallwithstand the pressures given in Table 1. Materials without adequate resistance to corrosion shall beprotected against corrosion.6.2 Exposed surface condition and quality of coatingVisible chromium plated surfaces and Ni-Cr coatings shall comply with the requirements of EN 248.7 Dimensional characteristics7.1 GeneralGeneral comment on design :¾ the design and construction of components without defined dimensions permits various design solutionsto be adopted by the manufacturer,¾ permitted deviations from the defined dimensions are given in 7.3.SIST EN 13905:2004
EN 13905:2003(E)77.2 Connecting dimensionsThe connecting dimensions of shower hoses are specified in Table 2 and Figures 1 to 3.Table 2 — Connecting dimensionsDimensionsValues in mmCommentsAG 1/2 or G 3/4Connecting thread (tap side) ISO 228-1BG 1/2Connecting thread (shower side)ISO 228-1CÆ 23 5010,,
+-orÆ 26 5010
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.