SIST EN 60835-1-2:2002/A1:2002
(Amendment)Methods of measurement for equipment used in digital microwave radio transmission systems -- Part 1: Measurements common to terrestrial radio-relay systems and satellite earth stations -- Section 2: Basic characteristics
- Abstract
EN following parallel vote
- Status
- Published
- Publication Date
- 30-Sep-2002
- Technical Committee
- OMS - Equipment used in mobile services and satelite comunication systems
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Oct-2002
- Due Date
- 01-Oct-2002
- Completion Date
- 01-Oct-2002
SIST EN 60835-1-2:2002/A1:2002 is the Slovene adoption of Amendment 1 to IEC/EN 60835-1-2 for methods of measurement in digital microwave radio transmission systems. It adds measurement guidance for noise temperature and noise figure in Part 1, Section 2, for terrestrial radio-relay systems and satellite earth stations. Engineers and test labs use it to choose a suitable measurement method and to report receiver noise performance in a consistent way.
What does SIST EN 60835-1-2:2002/A1:2002 specify?
SIST EN 60835-1-2:2002/A1:2002 specifies a new Clause 6 for measuring noise temperature and noise figure. The amendment is organized as an addition to the existing Part 1, Section 2, with subclauses for definitions, general considerations, measurement methods, result presentation, and details to be stated in a detailed equipment specification.
The added clause focuses on sub-systems and combinations of sub-systems under linear conditions where suitable ports are available. In practice, that means it is aimed at receiver chains, low-noise amplifiers, down-converters, and similar microwave equipment where noise performance needs to be measured rather than assumed.
What are the key requirements of SIST EN 60835-1-2:2002/A1:2002?
Clause 6.2 defines the main performance quantities. Noise figure is treated as a receiver quality measure, and equivalent noise temperature is linked to it by the standard relationship used in the clause. For the reader, this means the result may be stated either as kelvins or decibels, depending on what the specification or report needs.
The clause also distinguishes ordinary noise figure from single-sideband noise figure when a device has gain in more than one frequency band. That matters in satellite communication systems and other heterodyne arrangements, where only the noise in the signal band should be counted.
Clause 6.3 separates the methods into broadband and narrowband techniques. Broadband methods use noise generators, while narrowband methods use a continuous wave signal generator. The document points to the Y-factor method and the 3 dB loss method as the common broadband approaches, and to the c.w. method for narrowband measurements.
The Y-factor method uses a hot and a cold noise source together with a power meter. The hot and cold sources provide known input noise levels, and the ratio of the two output readings is used to calculate the result. This is the preferred method when high accuracy is needed.
The 3 dB loss method uses a fixed 3 dB attenuator and either a variable source or a fixed source. The variable source version is described with a diode noise generator, while the fixed source version uses a calibrated attenuator and excess noise ratio (ENR). In practice, the choice depends on frequency range, source type, and the accuracy available from the instrumentation.
The c.w. method applies a known sinusoidal input at the measurement frequency and compares output power with the signal off and on. The clause says the noise bandwidth of the equipment under test must be known for this method. That makes it useful when the test setup is narrowband and the bandwidth is already characterized.
Clause 6.5 gives the required form of the result. The measurement is reported as either equivalent noise temperature in kelvins or noise figure in decibels. Clause 6.7 then lists what the detailed equipment specification should state when the measurement is required, including the method, frequency and bandwidth, permitted input level, interface points, maximum permitted noise figure or equivalent noise temperature, ambient temperature, and ENR if applicable.
What terms does SIST EN 60835-1-2:2002/A1:2002 define?
Noise figure (NF) - The ratio used to show how much a device reduces signal-to-noise ratio between input and output under matched conditions.
Equivalent noise temperature (TE) - A fictitious temperature that gives the same output noise power density as the actual device.
Average noise figure - The noise figure taken over a stated bandwidth, unless another meaning is specified.
Y-factor - The ratio of the output noise levels obtained with the hot and cold noise sources.
Excess noise ratio (ENR) - A way of characterizing a fixed noise source based on how much its noise temperature exceeds 290 K.
Continuous wave (c.w.) - An unmodulated sine-wave signal used in the narrowband measurement method.
Who uses SIST EN 60835-1-2:2002/A1:2002?
SIST EN 60835-1-2:2002/A1:2002 is used by test engineers, RF measurement specialists, and laboratory staff working on digital microwave radio transmission equipment. It is also relevant to designers of terrestrial radio-relay systems and satellite earth stations who need to specify or verify receiver noise performance.
Quality managers and buyers use it when they need a measurable noise requirement in a product specification. It helps them state the test method, operating frequency range, bandwidth, and acceptable noise limit clearly enough for supplier testing.
What changed in SIST EN 60835-1-2:2002/A1:2002 from the previous edition?
SIST EN 60835-1-2:2002/A1:2002 adds Clause 6, titled Noise temperature and noise figure. The amendment also updates the contents page to include that clause and provides the related definitions, equations, measurement arrangements, result presentation, and specification details.
What does the SIST EN 60835-1-2:2002/A1:2002 document contain?
The document contains the amendment foreword, the updated contents entry, and the full text of Clause 6 with subclauses 6.1 to 6.7. It includes the practical measurement methods for Y-factor, 3 dB loss with a variable source, 3 dB loss with a fixed source, and the c.w. method.
It also includes the calculation relationships used to derive TE, NF, Y-factor, and ENR, together with notes on when each method is suitable. Figures 7 to 10 show the measurement arrangements for the four methods, which is useful when setting up a test bench or writing a laboratory procedure.
Relations
- Effective Date
- 21-Sep-2010
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 60835-1-2:2002/A1:2002 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Methods of measurement for equipment used in digital microwave radio transmission systems -- Part 1: Measurements common to terrestrial radio-relay systems and satellite earth stations -- Section 2: Basic characteristics". This standard covers: EN following parallel vote
EN following parallel vote
SIST EN 60835-1-2:2002/A1:2002 is classified under the following ICS (International Classification for Standards) categories: 33.060.30 - Radio relay and fixed satellite communications systems. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 60835-1-2:2002/A1:2002 has the following relationships with other standards: It is inter standard links to SIST EN 60835-1-2:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 60835-1-2:2002/A1:2002 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2002
Methods of measurement for equipment used in digital microwave radio
transmission systems - Part 1: Measurements common to terrestrial radio-relay
systems and satellite earth stations - Section 2: Basic characteristics -
Amendment A1 (IEC 60835-1-2:1992/A1:1995
Methods of measurement for equipment used in digital microwave radio transmission
systems -- Part 1: Measurements common to terrestrial radio-relay systems and satellite
earth stations -- Section 2: Basic characteristics
Meßverfahren für Geräte in digitalen Mikrowellen-Funkübertragungssystemen -- Teil 1:
Messungen an terrestrischen Richtfunksystemen und Satelliten-Erdfunkstellen --
Hauptabschnitt 2: Grundlegende Eigenschaften
Méthodes de mesure applicables au matériel utilisé pour les systèmes de transmission
numérique en hyperfréquence -- Partie 1: Mesures communes aux faisceaux hertziens
terrestres et aux stations terriennes de télécommunications par satellite -- Section 2:
Caractéristiques de base
Ta slovenski standard je istoveten z: EN 60835-1-2:1993/A1:1995
ICS:
33.060.30 Radiorelejni in fiksni satelitski Radio relay and fixed satellite
komunikacijski sistemi communications systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
NORME
CEI
INTERNATIONALE
IEC
INTERNATIONAL
60835-1-2
STANDARD
AMENDEMENT 1
AMENDMENT 1
1995-02
Amendement 1
Méthodes de mesure applicables au matériel
utilisé pour les systèmes de transmission
numérique en hyperfréquence
Partie 1:
Mesures communes aux faisceaux hertziens
terrestres et aux stations terriennes de
télécommunications par satellite
Section 2: Caractéristiques de base
Amendment 1
Methods of measurement for equipment used
in digital microwave radio transmission systems
Part 1:
Measurements common to terrestrial radio-relay
systems and satellite earth stations
Section 2: Basic characteristics
© CEI 1995 Droits de reproduction réservés — Copyright – all rights reserved
rn Genève, Suisse
Bureau Central de la Commission Electrotechnique Inte ationale 3, rue de Varembé
CODE PRIX
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
IEC MeregyHapo uiaa 3nexrporexHu4ecsan KoMHCCHA
Pour prix, voir catalogue en vigueur
•
For price, see current catalogue
835-1-2 Amend. 1 © IEC:1995 - 3 -
FOREWORD
This amendment has been prepared by sub-committee 12E: Radio relay and satellite
communication systems, of IEC technical committee 12: Radiocommunications.
The text of this amendment is based on the following documents:
DIS
Report on voting
12E(CO)164 12E/250/RVD
Full information on the voting for the approval of this amendment can be found in the
report on voting indicated in the above table.
Page 3
CONTENTS
Add the title of clause 6 as follows:
6 Noise temperature and noise figure
Page 29
Add, after 5.2.5, the following new clause:
6 Noise temperature and noise figure
Introduction
6.1
This clause concentrates on the methods of measurement to be used in order to evaluate
the noise figure of sub-systems and/or combinations of sub-systems under linear
conditions where appropriate ports are available.
Noise temperature is an important parameter in satellite systems and is a convenient
indication of the noise power produced by a system or sub-system. It is usually expressed
in terms of an "equivalent" temperature rather than an "actual" temperature, since it is a
measure of the effects of all the thermal and non-thermal noise sources.
6.2 Definitions
The performance of a receiver is generally characterized by its noise figure NF, expressed
in decibels. For a two-port device it is defined as the ratio of the signal-to-noise ratio at
the input to the signal-to-noise ratio at the output under matched conditions. The noise
figure therefore indicates how much the signal-to-noise ratio at the output is lower than at
the input. NF
is therefore always greater than 0 dB.
- 5 -
835-1-2 Amend. 1 © IEC:1995
The equivalent noise temperature, TE, is related to the noise figure F, expressed in linear
numerals, by the expression:
(7-1)
TE = 290 (F-1)
The noise figure NF, expressed in decibels, is defined as:
T
NF= 10 log o (7-2)
(1 + 290 )
6.2.1
Equivalent noise temperature of a two-port device
The equivalent noise temperature T E of a two-port device is a fictitious noise temperature
which, when added to that of the input source connected to a theoretically ideal noise-free,
two-po rt device having the same input impedance and gain as the actual device, will
produce the same output noise power density as the actual device.
o of a two-po rt device with an equivalent noise tempera-
The output noise power density N
ture TE when connected to a noise source of temperature T is given by:
SOURCE
(7-3)
TE ) kG (W/Hz)
No = (TSOURCE +
where
k is the Boltzmann's constant, 1,38 x 10-23 Ws/K;
G is the gain of the two-po rt device.
input noise temperature over a given bandwidth B, the
If TE is the equivalent average
output noise power Pm:, of a two-port device is then:
+ TE ) k GB (7-4)
Pno = (TSOURCE
where B is the noise bandwidth in hertz.
is assumed constant over the noise bandwidth B.
TSOURCE
Unless otherwise specified, the term "equivalent noise temperature" will be taken to mean
the average input noise temperature over a given bandwidth.
6.2.2
Average noise figure
The average noise figure F of a two-port device is the ratio of the total noise power P0
delivered by the device into a matched load, when the noise temperature of its input
termination is 290 K, to the noise power PS available under the same conditions at the
output port of an ideal noise-free device.
(7-5)
F. = Po - Po
PS kTGB
where T is equal to 290 K.
835-1-2 Amend. 1 © IEC:1995 -
7 -
For equipment having gain in more than one frequency band, such as an image frequency
in a heterodyne system, the denominator P S includes only the noise power from the input
termination which lies in the same frequency band as the modulated signal. This case is
applicable to satellite communication systems and is known as the "single-sideband noise
figure".
F and the average equivalent input
The relationship between the average noise figure
noise temperature TE can be obtained as follows:
Po = kGB • 290 + k TE GB = kGB (290 + TE ) (7-6)
From the above equations:
F kGB (290 + TE)
E
T
-
1 + (7-7)
kGB • 290
where
TE = 290 (F-1) (7-8)
Unless otherwise specified, the term "noise figure" will be taken to mean the average
noise figure over a given bandwidth.
6.3 General considerations
F are divided into two groups: broad-
The methods employed to measure the noise figure
band and narrowband techniques. Broadband techniques typically use noise generators as
measurement signals, whereas narrowband techniques employ continuous wave (c.w.)
signal generators.
The most widely used methods for broadband measurements are:
a) the Y-factor method;
b) the 3 dB loss method.
As a narrowband technique the c.w. method using an unmodulated signal is the most
widely used single-sideband measurement. This method is applicable from very low
frequencies to tens of GHz.
Automatic noise figure measuring equipment is available which uses the above
measurement techniques. Such equipment usually switches the noise generator (or signal
generator) periodically between two known output levels and measures the receiver output
noise levels. The noise figure is then computed automatically and is displayed directly on
an indicator.
The choice of method for a given situation will depend upon many factors including:
a) desired accuracy;
b) instrumentation required;
835-1-2 Amend. 1 © IEC:1995 - 9 -
c) frequency range;
d) type of equipment under test;
e) convenience;
f)
speed of measurement.
These methods are described in 6.4 together with their advantages and disadvantages,
with the intention of providing a general understanding of the basic procedures involved
for each method. The "equipment under test" can therefore be either a single sub-system,
for example a low-noise amplifier, or a combination of sub-systems, for example a low-
noise amplifier followed by a down-converter.
6.4 Method of measurement
Methods for measuring the noise figure are presented in the following subclauses. If
required, the equivalent noise temperature can then be calculated by equation (7-1) given
in 6.2.
All measurements are based on methods where either a broadband noise or sinusoidal
c.w. signal is applied to the input of the equipment under test and the increase in output
power due to the applied signal is recorded. The noise figure is then obtained either by
calculation or by directly reading a display, depending on the specific method used, as
given in the following.
6.4.1
Y-factor method
A pair of random noise generators and a power-meter are connected to the equipment
under test as shown in figure 7. One of the noise generators, designated "hot", has a
higher noise temperature, Th , than that of the other generator, designated "cold", which
has a noise temperature, Tc.
NOTE 1 — "Hot" or "cold" noise generator means the relative difference in noise temperatures between the
generators. The noise generator may be a simple matched load of ambient temperature.
Examples of cold and hot noise generator are as follows:
cold: a matched load cooled in the liquid nitrogen;
hot: a matched load heated in the oven, a current-saturated diode or a gas discharge
tube.
The hot and the cold noise generators provide known available noise powers to the equip-
ment under test. The output noise power levels of the equipment under test are measured
by the power meter. The Y-factor is the ratio of the two noise output power levels,
corresponding to the two input conditions. TE and F are calculated from the measured
Y-factor and the known noise temperature of the two noise sources.
The method is capable of high accuracy and measurement uncertainties as small as 1
(0,04 dB) are possible under optimum conditions. Typical me
...