Abstract

The present document covers the technical requirements for radio transmitters and receivers used in stations in the Private Mobile Radio (PMR) service. It applies to use in the land mobile service, operating on radio frequencies between 30 MHz and 3 GHz, with channel separations of 25 kHz, 50 kHz, 100 kHz and 150 kHz.
It applies to equipment for continuous and/or discontinuous transmission of data and/or digital speech. The equipment comprises a transmitter and associated encoder and modulator and/or a receiver and associated demodulator and decoder. The types of equipment covered by the present document are as follows:
base station (equipment fitted with an antenna connector, intended for use in a fixed location);
mobile station (equipment fitted with an antenna connector, normally used in a vehicle or as a transportable);
and those hand portable stations:
a) fitted with an antenna connector; or
b) without an external antenna connector (integral antenna equipment), but fitted with a permanent internal or a temporary internal 50 Ω Radio Frequency (RF) connector which allows access to the transmitter output and the receiver input. Hand portable equipment without an external or internal RF connector and without the possibility of having a temporary internal 50 Ω RF connector is not covered by the present document. These specifications do not necessarily include all the characteristics which may be required by a user of equipment, nor do they necessarily represent the optimum performance achievable. The present document is intended to cover the provisions of article 3.2 of Directive 1999/5/EC [i.4] (R&TTE Directive), which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive [i.4] may apply to equipment within the scope of the present document.

Status
Published
Public Enquiry End Date
31-Jul-2009
Publication Date
18-Jan-2010
Technical Committee
MOC - Mobile Communications
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
09-Dec-2009
Due Date
13-Feb-2010
Completion Date
19-Jan-2010
Mandate
M/284

Buy Documents

Standard

ETSI EN 302 561 V1.2.1 (2009-05) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment using constant or non-constant envelope modulation operating in a channel bandwidth of 25 kHz, 50 kHz, 100 kHz or 150 kHz; Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive

English language (62 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI EN 302 561 V1.2.1 (2009-09) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment using constant or non-constant envelope modulation operating in a channel bandwidth of 25 kHz, 50 kHz, 100 kHz or 150 kHz; Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive

English language (62 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI EN 302 561 V1.2.1 (2009-12) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment using constant or non-constant envelope modulation operating in a channel bandwidth of 25 kHz, 50 kHz, 100 kHz or 150 kHz; Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive

English language (63 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

SIST EN 302 561 V1.2.1:2010

English language (63 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 302 561 V1.2.1:2010 is the Slovenian adoption of ETSI EN 302 561 V1.2.1, published by SIST for Private Mobile Radio (PMR) equipment. It specifies radio test requirements for transmitters and receivers used in the land mobile service with constant or non-constant envelope modulation in 25 kHz, 50 kHz, 100 kHz or 150 kHz channels, so manufacturers, test labs and conformity assessors can check spectrum use and radio performance under article 3.2 of the R&TTE Directive.

What does SIST EN 302 561 V1.2.1:2010 specify?

SIST EN 302 561 V1.2.1:2010 covers technical requirements for PMR radio equipment operating from 30 MHz to 3 GHz and sending data and/or digital speech in continuous or discontinuous transmission. It applies to base stations, mobile stations and certain hand portable stations, including integral-antenna equipment only when a 50 Ω RF test access is available.

The document is organized into general clauses, transmitter requirements, receiver requirements, measurement uncertainty, and normative annexes for conformity and test practice.

AnnexWhat it covers
Annex AHS Requirements and conformance Test specifications Table (HS-RTT)
Annex BRadiated measurement methods and test sites
Annex CSpectrum analyser specification
Annex DEN title in the official languages
Annex EBibliography

What are the key requirements of SIST EN 302 561 V1.2.1:2010?

Clause 4 requires the provider or manufacturer to declare the operating frequency ranges, operating conditions and power requirements, and to supply enough technical documentation and operating information for testing. In practice, the test lab needs those declarations to set up the right bands, modes and power conditions.

Clause 4.2 requires measurements on each implemented channel bandwidth when the equipment supports more than one mode. That matters because a multimode radio may pass in one bandwidth and fail in another.

Clause 5 defines the test environment. Normal tests use declared mains or battery voltages and ordinary laboratory temperature and humidity, while extreme tests use the specified temperature and voltage ranges for mobile, hand portable and base station equipment. This is what makes the results representative of real field conditions.

Clause 6 defines the common measurement setup: artificial load, wanted and unwanted test signals, encoder settings, impedance, PEP, duplex operation and transmitter operating modes. These definitions matter because the transmitter and receiver limits are only meaningful if the test signals and loading are arranged consistently.

Clause 7 sets the transmitter requirements. It covers conducted output power for equipment with an antenna port, maximum effective radiated power for integral-antenna equipment, adjacent and alternate channel power, spurious emissions, intermodulation attenuation for base stations, adjacent channel transient power, and frequency error. For a buyer or engineer, this is the main section that shows whether the radio is spectrally clean enough and stays on frequency.

Clause 8 covers receiver performance. It includes conducted sensitivity for equipment with an external antenna connector, field-strength sensitivity for equipment without one, blocking or desensitization, adjacent channel selectivity, spurious radiations, co-channel rejection, and intermodulation response rejection. Annex A makes clear that several receiver immunity tests apply only when the equipment uses Listen Before Transmit mode (LBT), so the applicability depends on the radio’s operating concept.

Clause 9 requires measurement uncertainty to be reported separately for each parameter and kept within the values given in the document. In practice, this is important for test reports and pass/fail decisions because the measured value is what is compared to the limit.

What terms does SIST EN 302 561 V1.2.1:2010 define?

  • Private Mobile Radio (PMR) - the service class covered by the standard, used for private land mobile radio systems.
  • Equipment Under Test (EUT) - the device being measured in a test setup.
  • Listen Before Transmit mode (LBT) - a channel-monitoring mode where the radio checks for activity before it transmits.
  • Peak Envelope Power (PEP) - the maximum power at the signal envelope peak.
  • Base station - equipment with an antenna connector intended for fixed installation.
  • Hand portable station - equipment carried or held by a person, with an antenna connector or integral antenna.
  • Integral antenna - an antenna built into the equipment rather than attached through an external 50 Ω connector.

Who uses SIST EN 302 561 V1.2.1:2010?

Manufacturers use SIST EN 302 561 V1.2.1:2010 when designing PMR transmitters and receivers and preparing technical files. Test laboratories use it for type testing, radiated measurements, and receiver and transmitter conformance checks.

Quality managers and procurement teams use it to define acceptance criteria for radio equipment purchases. Regulators and conformity assessors use it as a harmonized basis for article 3.2 radio spectrum compliance.

Which standards are used with SIST EN 302 561 V1.2.1:2010?

  • ITU-T Recommendation O.153 - basic parameters for error performance measurements.
  • ETSI TR 100 028 - measurement uncertainty guidance for mobile radio equipment.
  • ETSI TR 102 273 - guidance on radiated methods of measurement and test-site uncertainty.
  • ANSI C63.5 - antenna calibration for radiated emission measurements.
  • ETSI EN 300 392-2 - TETRA Voice plus Data air interface, referenced for one of the related radio technologies.
  • ITU-R Recommendation SM.329-10 and CEPT/ERC/REC 74-01 - background references on unwanted emissions in the spurious domain.
  • ETSI EG 201 399 - guide to the modular structure used for harmonized standards under the R&TTE Directive.

What does the SIST EN 302 561 V1.2.1:2010 document contain?

The document contains detailed test methods, setup diagrams and limit tables for transmitter and receiver measurements. It includes conducted and radiated arrangements, spectrum-analyser settings, substitution methods, and step-by-step procedures for sensitivity, blocking, selectivity, spurious emissions and frequency error.

Annex B describes practical radiated test sites such as anechoic chambers, ground-plane chambers and open area test sites, plus antenna and cabling guidance. Annex C gives the spectrum-analyser requirements used by the transient-power measurements. Annex A ties the technical clauses to the harmonized-standard conformity table used for presumption of conformity.

Buy Documents

Standard

ETSI EN 302 561 V1.2.1 (2009-05) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment using constant or non-constant envelope modulation operating in a channel bandwidth of 25 kHz, 50 kHz, 100 kHz or 150 kHz; Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive

English language (62 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI EN 302 561 V1.2.1 (2009-09) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment using constant or non-constant envelope modulation operating in a channel bandwidth of 25 kHz, 50 kHz, 100 kHz or 150 kHz; Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive

English language (62 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI EN 302 561 V1.2.1 (2009-12) - Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment using constant or non-constant envelope modulation operating in a channel bandwidth of 25 kHz, 50 kHz, 100 kHz or 150 kHz; Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive

English language (63 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

SIST EN 302 561 V1.2.1:2010

English language (63 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 302 561 V1.2.1:2010 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility and Radio spectrum Matters (ERM) - Land Mobile Service - Radio equipment using constant or non-constant envelope modulation operating in a channel bandwidth of 25 kHz, 50 kHz, 100 kHz or 150 kHz - Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive". This standard covers: The present document covers the technical requirements for radio transmitters and receivers used in stations in the Private Mobile Radio (PMR) service. It applies to use in the land mobile service, operating on radio frequencies between 30 MHz and 3 GHz, with channel separations of 25 kHz, 50 kHz, 100 kHz and 150 kHz. It applies to equipment for continuous and/or discontinuous transmission of data and/or digital speech. The equipment comprises a transmitter and associated encoder and modulator and/or a receiver and associated demodulator and decoder. The types of equipment covered by the present document are as follows: base station (equipment fitted with an antenna connector, intended for use in a fixed location); mobile station (equipment fitted with an antenna connector, normally used in a vehicle or as a transportable); and those hand portable stations: a) fitted with an antenna connector; or b) without an external antenna connector (integral antenna equipment), but fitted with a permanent internal or a temporary internal 50 Ω Radio Frequency (RF) connector which allows access to the transmitter output and the receiver input. Hand portable equipment without an external or internal RF connector and without the possibility of having a temporary internal 50 Ω RF connector is not covered by the present document. These specifications do not necessarily include all the characteristics which may be required by a user of equipment, nor do they necessarily represent the optimum performance achievable. The present document is intended to cover the provisions of article 3.2 of Directive 1999/5/EC [i.4] (R&TTE Directive), which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive [i.4] may apply to equipment within the scope of the present document.

The present document covers the technical requirements for radio transmitters and receivers used in stations in the Private Mobile Radio (PMR) service. It applies to use in the land mobile service, operating on radio frequencies between 30 MHz and 3 GHz, with channel separations of 25 kHz, 50 kHz, 100 kHz and 150 kHz. It applies to equipment for continuous and/or discontinuous transmission of data and/or digital speech. The equipment comprises a transmitter and associated encoder and modulator and/or a receiver and associated demodulator and decoder. The types of equipment covered by the present document are as follows: base station (equipment fitted with an antenna connector, intended for use in a fixed location); mobile station (equipment fitted with an antenna connector, normally used in a vehicle or as a transportable); and those hand portable stations: a) fitted with an antenna connector; or b) without an external antenna connector (integral antenna equipment), but fitted with a permanent internal or a temporary internal 50 Ω Radio Frequency (RF) connector which allows access to the transmitter output and the receiver input. Hand portable equipment without an external or internal RF connector and without the possibility of having a temporary internal 50 Ω RF connector is not covered by the present document. These specifications do not necessarily include all the characteristics which may be required by a user of equipment, nor do they necessarily represent the optimum performance achievable. The present document is intended to cover the provisions of article 3.2 of Directive 1999/5/EC [i.4] (R&TTE Directive), which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive [i.4] may apply to equipment within the scope of the present document.

SIST EN 302 561 V1.2.1:2010 is classified under the following ICS (International Classification for Standards) categories: 33.060.99 - Other equipment for radiocommunications; 33.070.01 - Mobile services in general; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 302 561 V1.2.1:2010 is associated with the following European legislation: EU Directives/Regulations: 1999/5/EC, TRRTP124; Standardization Mandates: M/284. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 302 561 V1.2.1:2010 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 7 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 1 Scope
  • 8 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 2 References
  • 2.1 Normative references
  • 2.2 Informative references
  • 9 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 3 Definitions, symbols and abbreviations
  • 3.1 Definitions
  • 10 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 3.2 Symbols
  • 3.3 Abbreviations
  • 11 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 4 General
  • 4.1 Presentation of equipment for testing purposes
  • 4.2 Multi-Mode equipment
  • 12 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 4.3 Testing of equipment that does not have an external 50 Ω
  • 5 Test conditions, power sources and ambient
  • 5.1 Normal and extreme test conditions
  • 5.2 Test power source
  • 5.3 Normal test conditions
  • 13 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 5.4 Extreme test conditions
  • 14 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 5.5 Procedure for tests at extreme temperatures
  • 15 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 6 General test conditions
  • 6.1 Arrangements for test signals applied to the receiver input
  • 6.2 Test load (artificial antenna)
  • 6.3 Test signals (wanted and unwanted signals)
  • 16 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 6.4 Encoder
  • 17 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 6.5 Transceiver data interface
  • 6.6 Impedance
  • 6.7 PEP
  • 6.8 Duplex equipment
  • 6.9 Modes of operation of the transmitter
  • 18 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 6.10 Measurement filter definition
  • 7 Technical characteristics of the transmitter
  • 7.1 Transmitter output power (conducted)
  • 19 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 7.2 Maximum effective radiated power
  • 20 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 21 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 7.3 Adjacent and alternate channel power
  • 22 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 23 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 7.4 Unwanted emissions in the spurious domain
  • 24 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 25 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 26 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 30 MHz to 1 GHz 100 kHz
  • 1 GHz to 12,75 GHz 1 MHz
  • 27 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 28 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 7.5 Intermodulation attenuation
  • 29 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 7.6 Adjacent channel transient power measurements
  • 30 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 7.7 Frequency error
  • 31 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 8 Technical characteristics of the receiver
  • 8.1 Receiver sensitivity (conducted)
  • 32 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 33 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 8.2 Maximum usable sensitivity (field strength)
  • 34 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 35 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 36 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 37 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 8.3 Blocking or desensitization
  • 38 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 39 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 40 Draft ETSI EN 302 561 V1.2.1 (2009-05)
  • 8.4 Adjacent channel selectivity
  • 41 Draft ETSI EN 302 561 V1.2.1 (2009-05)

Introduction

The present document is part of a set of standards developed by ETSI and is designed to fit in a modular structure to cover all radio and telecommunications terminal equipment within the scope of the R&TTE Directive [i.4]. The modular structure is shown in EG 201 399 [i.3].

ETSI

7 Draft ETSI EN 302 561 V1.2.1 (2009-05)

1 Scope

The present document covers the technical requirements for radio transmitters and receivers used in stations in the Private Mobile Radio (PMR) service.

It applies to use in the land mobile service, operating on radio frequencies between 30 MHz and 3 GHz, with channel separations of 25 kHz, 50 kHz, 100 kHz and 150 kHz.

Table 1: Radiocommunications service frequency bands Radiocommunications service frequency bands Transmit 30 MHz to 3 000 MHz Receive 30 MHz to 3 000 MHz

It applies to equipment for continuous and/or discontinuous transmission of data and/or digital speech. The equipment comprises a transmitter and associated encoder and modulator and/or a receiver and associated demodulator and decoder. The types of equipment covered by the present document are as follows:

  • base station (equipment fitted with an antenna connector, intended for use in a fixed location);
  • mobile station (equipment fitted with an antenna connector, normally used in a vehicle or as a transportable);
  • and those hand portable stations:

a) fitted with an antenna connector; or b) without an external antenna connector (integral antenna equipment), but fitted with a permanent internal or a temporary internal 50 Ω Radio Frequency (RF) connector which allows access to the transmitter output and the receiver input.

Hand portable equipment without an external or internal RF connector and without the possibility of having a temporary internal 50 Ω RF connector is not covered by the present document. These specifications do not necessarily include all the characteristics which may be required by a user of equipment, nor do they necessarily represent the optimum performance achievable. The present document is intended to cover the provisions of article 3.2 of Directive 1999/5/EC (R&TTE Directive) [i.4], which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive [i.4] may apply to equipment within the scope of the present document.

NOTE: A list of such ENs is included on the web site http://www.newapproach.org. ETSI

8 Draft ETSI EN 302 561 V1.2.1 (2009-05)

2 References

References are either specific (identified by date of publication and/or edition number or version number) or non-specific.

  • For a specific reference, subsequent revisions do not apply.
  • Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
  • if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document;
  • for informative references.

Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.

NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.

2.1 Normative references

The following referenced documents are indispensable for the application of the present document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.

[1] ITU-T Recommendation O.153 (1992): "Basic parameters for the measurement of error performance at bit rates below the primary rate".

[2] ETSI TR 100 028 (1.4.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". [3] ETSI TR 102 273 (1.2.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Improvement on Radiated Methods of Measurement (using test site) and evaluation of the corresponding measurement uncertainties".

[4] ANSI C63.5 (2004): "American National Standard for Electromagnetic Compatibility-Radiated Emission Measurements in Electromagnetic Interference (EMI) Control-Calibration of Antennas (9 kHz to 40 GHz)".

[5] ETSI EN 300 392-2 (V3.2.1): "Terrestrial Trunked Radio (TETRA); Voice plus Data (V+D); Part 2: Air Interface (AI)".

2.2 Informative references

The following referenced documents are not essential to the use of the present document but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the referenced document (including any amendments) applies.

[i.1] ITU-R Recommendation SM.329-10 (2003): "Unwanted emissions in the spurious domain". [i.2] CEPT/ERC/REC 74-01 (2005): "Unwanted Emissions in the Spurious domain". [i.3] ETSI EG 201 399 (V2.1.1): "Electromagnetic compatibility and Radio spectrum Matters (ERM); A guide to the production of candidate Harmonized Standards for application under the R&TTE Directive".

[i.4] Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R&TTE Directive).

ETSI

9 Draft ETSI EN 302 561 V1.2.1 (2009-05)

[i.5] Directive 98/34/EC of the European Parliament and of the Council of 22 June 1998 laying down a procedure for the provision of information in the field of technical standards and regulations.

3 Definitions, symbols and abbreviations

3.1 Definitions

For the purposes of the present document, the following terms and definitions apply:

base station: equipment fitted with an antenna connector, for use with an external antenna, and intended for use in a fixed location bit: binary digit block: the smallest quantity of information that is sent over the radio channel NOTE: A constant number of useful bits are always sent together with the corresponding redundancy bits. burst or transmission (physical): one or several packets transmitted between power on and power off of a particular transmitter conducted measurements: measurements which are made using direct 50 Ω connection to the equipment under test data transmission systems: systems which transmit and/or receive data and/or digitized voice hand portable station: equipment either fitted with an antenna connector or integral antenna, or both, normally used on a stand-alone basis, to be carried on a person or held in the hand integral antenna: antenna designed to be connected to the equipment without the use of a 50 Ω external connector and considered to be part of the equipment NOTE: An integral antenna may be fitted internally or externally to the equipment. Listen Before Transmit mode (LBT): monitoring mode in which the RF channel is checked for activity before transmitting NOTE: Examples for LBT are transceivers or systems implementing squelch or RSSI (Receiver Signal Strength Indicator) algorithms for evaluating the status of the channel. message: user data to be transferred in one or more packets in a session mobile station: mobile equipment fitted with an antenna connector, for use with an external antenna, normally used in a vehicle or as a transportable station packet: one block or a contiguous stream of blocks sent by one (logical) transmitter to one particular receiver or one particular group of receivers radiated measurements: measurements which involve the absolute measurement of a radiated field receive band of the equipment: maximum frequency range (declared by the manufacturer) over which the receiver can be operated without reprogramming or realignment session: set of inter-related exchange of packets occupying one or several windows or part thereof (if applicable) NOTE: It corresponds to a complete interactive procedure for interchanging data between users, comprising initiation, data transmission and termination procedures. The session can be short (e.g. 2 packets), or long (e.g. one full page of text).

spurious emissions: unwanted emissions in the spurious domain switching range (sr): maximum frequency range, as specified by the manufacturer, over which the receiver or the transmitter can be operated within the alignment range without reprogramming or realignment ETSI

10 Draft ETSI EN 302 561 V1.2.1 (2009-05)

testing laboratory: laboratory that performs tests transmit band of the equipment: maximum frequency range (declared by the manufacturer) over which the transmitter can be operated without reprogramming or realignment window: set of inter-related transmissions which may be limited in time by an appropriate access protocol and corresponding occupation rules

3.2 Symbols

For the purposes of the present document, the following symbols apply:

α Filter rolloff factor dB decibel dBm dB relative to 1 mW dBμV dB relative to 1 μV f channel centre frequency

f LO Local Oscillator frequency f the frequency offset corresponding to the near edge of the receive band rb M1, M2, etc names of test signals defined in clause 6.3 PR rms power PX maximum Power (Peak Envelope Power) V minimum extreme test Voltage min V maximum extreme test Voltage max T minimum extreme test Temperature min T maximum extreme test Temperature max λ wavelength

3.3 Abbreviations

For the purposes of the present document, the following abbreviations apply:

ac alternating current ARQ Automatic Repeat reQuest BS Base Station BW BandWidth CBW Channel BandWidth CSP Channel SeParation CW Continuous Wave dBc decibels relative to the transmitter power EUT Equipment Under Test GMSK Gaussian Minimum Shift Keying IF Intermediate Frequency LBT Listen Before Transmit MBW Measurement BandWidth MS Mobile Station OATS Open Area Test Site PEP Peak Envelope Power PMR Private Mobile Radio ppm parts per million RF Radio Frequency rms root mean square RSSI Received Signal Strength Indicator Rx Receiver sr switching range Tx Transmitter VSWR Voltage Standing Wave Ratio ETSI

11 Draft ETSI EN 302 561 V1.2.1 (2009-05)

4 General

4.1 Presentation of equipment for testing purposes

Each equipment submitted to be tested shall fulfil the requirements of the present document on all frequencies over which it is intended to operate.

The radio tests shall be performed on the lowest, the highest and the middle radio frequency channels of either the transmit or receive band of the equipment, whichever is appropriate. The provider or manufacturer shall declare the frequency ranges, the range of operating conditions and power requirements as applicable, to establish the appropriate test conditions. Information related to radio sub-system of equipment includes the transmit and receive frequency bands, first local oscillator frequency and intermediate frequencies of the receiver.

Additionally, technical documentation and operating manuals, sufficient to make the test, shall be supplied.

4.1.1 Choice of model for testing

The provider or manufacturer shall provide one or more samples of the equipment, as appropriate for testing. Stand-alone equipment shall be complete with any ancillary equipment needed for testing. If an equipment has several optional features, considered not to affect the RF parameters then the tests need only to be performed on the equipment configured with the combination of features considered to be the most complex. Where practicable, equipment to be tested shall provide a 50 Ω connector for conducted RF power level measurements. In the case of integral antenna equipment, if the equipment does not have an internal permanent 50 Ω connector then it is permissible to supply a second sample of the equipment with a temporary antenna connector fitted to facilitate testing.

The test connector shall also provide any test signalling data. The performance of the equipment to be tested shall be representative of the performance of the corresponding production model.

4.1.1.1 Auxiliary test equipment

All necessary test signal sources, setting up instructions and other product information shall accompany the equipment to be tested.

4.1.1.2 Declarations by the provider

The provider or manufacturer shall declare the necessary information of the equipment with respect to all technical requirements set by the present document.

4.2 Multi-Mode equipment

In the case of equipment supporting more than one channel bandwidth, measurements shall be performed on each channel bandwidth implemented.

ETSI

12 Draft ETSI EN 302 561 V1.2.1 (2009-05)

4.3 Testing of equipment that does not have an external 50 Ω

RF connector (integral antenna equipment) Where equipment has an internal 50 Ω connector it shall be permitted to perform the tests at this connector. Equipment may also have a temporary internal 50 Ω connector installed for the purposes of testing. No connection shall be made to any internal permanent or temporary antenna connector during the performance of radiated emissions measurements, unless such action forms an essential part of the normal intended operation of the equipment, as declared by the manufacturer.

5 Test conditions, power sources and ambient

temperatures

5.1 Normal and extreme test conditions

Testing shall be performed under normal test conditions, and also, where stated, under extreme test conditions. The test conditions and procedures shall be as specified in clauses 5.2 to 5.5.

5.2 Test power source

During testing the power source of the equipment shall be replaced by a test power source capable of producing normal and extreme test voltages as specified in clauses 5.3.2 and 5.4.2. The internal impedance of the test power source shall be low enough for its effect on the test results to be negligible. For the purpose of tests, the voltage of the power source shall be measured at the input terminals of the equipment.

For battery operated equipment the battery shall be removed and the test power source shall be applied as close to the battery terminals as practicable.

During tests of DC powered equipment the power source voltages shall be maintained within a tolerance of < ±1 % relative to the voltage at the beginning of each test. The value of this tolerance is critical for power measurements, using a smaller tolerance will provide better measurement uncertainty values.

5.3 Normal test conditions

5.3.1 Normal temperature and humidity

The normal temperature and humidity conditions for tests shall be any convenient combination of temperature and humidity within the following ranges:

temperature: +15 °C to +35 °C; relative humidity: 20 % to 75 %.

When it is impracticable to carry out the tests under these conditions, a note to this effect, stating the ambient temperature and relative humidity during the tests, shall be added to the test report. ETSI

13 Draft ETSI EN 302 561 V1.2.1 (2009-05)

5.3.2 Normal test power source
5.3.2.1 Mains voltage

The normal test voltage for equipment to be connected to the mains shall be the nominal mains voltage. For the purpose of the present document, the nominal voltage shall be the declared voltage or any of the declared voltages for which the equipment was designed.

The frequency of the test power source corresponding to the ac mains shall be between 49 Hz and 51 Hz.

5.3.2.2 Regulated lead-acid battery power sources used on vehicles

When the radio equipment is intended for operation from the usual types of regulated lead-acid battery power source used on vehicles the normal test voltage shall be 1,1 times the nominal voltage of the battery (for nominal voltages of 6 V and 12 V, these are 6,6 V and 13,2 V respectively).

5.3.2.3 Other power sources

For operation from other power sources or types of battery (primary or secondary), the normal test voltage shall be that declared by the equipment manufacturer.

5.4 Extreme test conditions

5.4.1 Extreme temperatures

For tests at extreme temperatures, measurements shall be made in accordance with the procedures specified in clause 5.5, at the upper and lower temperatures of one of the following two ranges:

  • -20 °C to +55 °C; All mobile and hand portable equipment.

Base stations for outdoor/uncontrolled climate conditions.

  • 0 °C to +40 °C; Base stations for indoor/controlled climate conditions.

In the case of base stations equipment, the manufacturer shall declare which conditions the equipment is intended to be installed in.

5.4.2 Extreme test source voltages
5.4.2.1 Mains voltage

The extreme test voltage for equipment to be connected to an ac mains source shall be the nominal mains voltage ± 10 %.

5.4.2.2 Regulated lead-acid battery power sources used on vehicles

When the equipment is intended for operation from the usual types of regulated lead-acid battery power sources used on vehicles the extreme test voltages shall be 1,3 and 0,9 times the nominal voltage of the battery (for a nominal voltage of 6 V, these are 7,8 V and 5,4 V respectively and for a nominal voltage of 12 V, these are 15,6 V and 10,8 V respectively).

ETSI

14 Draft ETSI EN 302 561 V1.2.1 (2009-05)

5.4.2.3 Power sources using other types of batteries

The lower extreme test voltages for equipment with power sources using batteries shall be as follows:

  • for the nickel metal-hydride, leclanché or lithium type: 0,85 times the nominal battery voltage;
  • for the mercury or nickel-cadmium type: 0,9 times the nominal battery voltage. No upper extreme test voltages apply.

In the case where no upper extreme test voltage the nominal voltage is applicable, the corresponding four extreme test conditions are:

  • V /T , V /T ; min min min max
  • (V = nominal)/T , (V = nominal)/T .

max min max max

5.4.2.4 Other power sources

For equipment using other power sources, or capable of being operated from a variety of power sources, the extreme test voltages shall be those declared by the equipment manufacturer.

5.5 Procedure for tests at extreme temperatures

Before measurements are made the equipment shall have reached thermal balance in the test chamber. The equipment shall be switched off during the temperature stabilizing period. In the case of equipment containing temperature stabilization circuits designed to operate continuously, the temperature stabilization circuits may be switched on for 15 minutes after thermal balance has been obtained, and the equipment shall then meet the specified requirements. For such equipment the manufacturer shall provide for the power source circuit feeding the crystal oven to be independent of the power source for the rest of the equipment. If the thermal balance is not checked by measurements, a temperature stabilizing period of at least one hour, or a longer period as may be decided by the testing laboratory, shall be allowed. The sequence of measurements shall be chosen, and the humidity content in the test chamber shall be controlled so that excessive condensation does not occur.

5.5.1 Procedure for equipment designed for continuous transmission

If the manufacturer states that the equipment is designed for continuous transmission, the test procedure shall be as follows.

Before tests at the upper extreme temperature, the equipment shall be placed in the test chamber, and left until thermal balance is attained. The equipment shall then be switched on in the transmit condition with modulation M1 or M2 (as appropriate, see clause 6.3.1), for a period of half an hour, after which the equipment shall meet the specified requirements.

...

Contents

  • Introduction
  • 7 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 1 Scope
  • 2 References
  • 8 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 2.1 Normative references
  • 2.2 Informative references
  • 9 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 3 Definitions, symbols and abbreviations
  • 3.1 Definitions
  • 10 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 3.2 Symbols
  • 3.3 Abbreviations
  • 11 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 4 General
  • 4.1 Presentation of equipment for testing purposes
  • 4.2 Multi-Mode equipment
  • 12 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 4.3 Testing of equipment that does not have an external 50 Ω
  • 5 Test conditions, power sources and ambient
  • 5.1 Normal and extreme test conditions
  • 5.2 Test power source
  • 5.3 Normal test conditions
  • 13 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 5.4 Extreme test conditions
  • 14 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 5.5 Procedure for tests at extreme temperatures
  • 15 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 6 General test conditions
  • 6.1 Arrangements for test signals applied to the receiver input
  • 6.2 Test load (artificial antenna)
  • 6.3 Test signals (wanted and unwanted signals)
  • 16 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 6.4 Encoder
  • 17 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 6.5 Transceiver data interface
  • 6.6 Impedance
  • 6.7 PEP
  • 6.8 Duplex equipment
  • 6.9 Modes of operation of the transmitter
  • 6.10 Measurement filter definition
  • 18 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 7 Technical characteristics of the transmitter
  • 7.1 Transmitter output power (conducted)
  • 7.2 Maximum effective radiated power
  • 19 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 20 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 7.3 Adjacent and alternate channel power
  • 21 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 22 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 7.4 Unwanted emissions in the spurious domain
  • 23 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 24 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 25 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 26 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 30 MHz to 1 GHz 100 kHz
  • 1 GHz to 12,75 GHz 1 MHz
  • 27 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 28 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 7.5 Intermodulation attenuation
  • 29 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 7.6 Adjacent channel transient power measurements
  • 30 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 7.7 Frequency error
  • 31 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 8 Technical characteristics of the receiver
  • 8.1 Receiver sensitivity (conducted)
  • 32 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 33 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 8.2 Maximum usable sensitivity (field strength)
  • 34 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 35 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 36 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 37 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 8.3 Blocking or desensitization
  • 38 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 39 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 8.4 Adjacent channel selectivity
  • 40 Final draft ETSI EN 302 561 V1.2.1 (2009-09)
  • 41 Final draft ETSI EN 302 561 V1.2.1 (2009-09)

Introduction

The present document is part of a set of standards developed by ETSI and is designed to fit in a modular structure to cover all radio and telecommunications terminal equipment within the scope of the R&TTE Directive [i.4]. The modular structure is shown in EG 201 399 [i.3].

ETSI

7 Final draft ETSI EN 302 561 V1.2.1 (2009-09)

1 Scope

The present document covers the technical requirements for radio transmitters and receivers used in stations in the Private Mobile Radio (PMR) service.

It applies to use in the land mobile service, operating on radio frequencies between 30 MHz and 3 GHz, with channel separations of 25 kHz, 50 kHz, 100 kHz and 150 kHz.

Table 1: Radiocommunications service frequency bands Radiocommunications service frequency bands Transmit 30 MHz to 3 000 MHz Receive 30 MHz to 3 000 MHz

It applies to equipment for continuous and/or discontinuous transmission of data and/or digital speech. The equipment comprises a transmitter and associated encoder and modulator and/or a receiver and associated demodulator and decoder. The types of equipment covered by the present document are as follows:

  • base station (equipment fitted with an antenna connector, intended for use in a fixed location);
  • mobile station (equipment fitted with an antenna connector, normally used in a vehicle or as a transportable);
  • and those hand portable stations:

a) fitted with an antenna connector; or b) without an external antenna connector (integral antenna equipment), but fitted with a permanent internal or a temporary internal 50 Ω Radio Frequency (RF) connector which allows access to the transmitter output and the receiver input.

Hand portable equipment without an external or internal RF connector and without the possibility of having a temporary internal 50 Ω RF connector is not covered by the present document. These specifications do not necessarily include all the characteristics which may be required by a user of equipment, nor do they necessarily represent the optimum performance achievable. The present document is intended to cover the provisions of article 3.2 of Directive 1999/5/EC [i.4] (R&TTE Directive), which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive [i.4] may apply to equipment within the scope of the present document.

NOTE: A list of such ENs is included on the web site http://www.newapproach.org.

2 References

References are either specific (identified by date of publication and/or edition number or version number) or non-specific.

  • For a specific reference, subsequent revisions do not apply.
  • Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
  • if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document; ETSI

8 Final draft ETSI EN 302 561 V1.2.1 (2009-09)

  • for informative references.

Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.

NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.

2.1 Normative references

The following referenced documents are indispensable for the application of the present document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.

[1] ITU-T Recommendation O.153 (1992): "Basic parameters for the measurement of error performance at bit rates below the primary rate".

[2] ETSI TR 100 028 (V1.4.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". [3] ETSI TR 102 273 (V1.2.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Improvement on Radiated Methods of Measurement (using test site) and evaluation of the corresponding measurement uncertainties".

[4] ANSI C63.5 (2004): "American National Standard for Electromagnetic Compatibility-Radiated Emission Measurements in Electromagnetic Interference (EMI) Control-Calibration of Antennas (9 kHz to 40 GHz)".

[5] ETSI EN 300 392-2 (V3.2.1): "Terrestrial Trunked Radio (TETRA); Voice plus Data (V+D); Part 2: Air Interface (AI)".

2.2 Informative references

The following referenced documents are not essential to the use of the present document but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the referenced document (including any amendments) applies.

[i.1] ITU-R Recommendation SM.329-10 (2003): "Unwanted emissions in the spurious domain". [i.2] CEPT/ERC/REC 74-01 (2005): "Unwanted Emissions in the Spurious domain". [i.3] ETSI EG 201 399 (V2.1.1): "Electromagnetic compatibility and Radio spectrum Matters (ERM); A guide to the production of candidate Harmonized Standards for application under the R&TTE Directive".

[i.4] Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R&TTE Directive).

[i.5] Directive 98/34/EC of the European Parliament and of the Council of 22 June 1998 laying down a procedure for the provision of information in the field of technical standards and regulations. ETSI

9 Final draft ETSI EN 302 561 V1.2.1 (2009-09)

3 Definitions, symbols and abbreviations

3.1 Definitions

For the purposes of the present document, the following terms and definitions apply:

base station: equipment fitted with an antenna connector, for use with an external antenna, and intended for use in a fixed location bit: binary digit block: the smallest quantity of information that is sent over the radio channel NOTE: A constant number of useful bits are always sent together with the corresponding redundancy bits. burst or transmission (physical): one or several packets transmitted between power on and power off of a particular transmitter conducted measurements: measurements which are made using direct 50 Ω connection to the equipment under test data transmission systems: systems which transmit and/or receive data and/or digitized voice hand portable station: equipment either fitted with an antenna connector or integral antenna, or both, normally used on a stand-alone basis, to be carried on a person or held in the hand integral antenna: antenna designed to be connected to the equipment without the use of a 50 Ω external connector and considered to be part of the equipment NOTE: An integral antenna may be fitted internally or externally to the equipment. Listen Before Transmit mode (LBT): monitoring mode in which the RF channel is checked for activity before transmitting NOTE: Examples for LBT are transceivers or systems implementing squelch or RSSI (Receiver Signal Strength Indicator) algorithms for evaluating the status of the channel. message: user data to be transferred in one or more packets in a session mobile station: mobile equipment fitted with an antenna connector, for use with an external antenna, normally used in a vehicle or as a transportable station packet: one block or a contiguous stream of blocks sent by one (logical) transmitter to one particular receiver or one particular group of receivers radiated measurements: measurements which involve the absolute measurement of a radiated field receive band of the equipment: maximum frequency range (declared by the manufacturer) over which the receiver can be operated without reprogramming or realignment session: set of inter-related exchange of packets occupying one or several windows or part thereof (if applicable) NOTE: It corresponds to a complete interactive procedure for interchanging data between users, comprising initiation, data transmission and termination procedures. The session can be short (e.g. 2 packets), or long (e.g. one full page of text).

spurious emissions: unwanted emissions in the spurious domain switching range (sr): maximum frequency range, as specified by the manufacturer, over which the receiver or the transmitter can be operated within the alignment range without reprogramming or realignment testing laboratory: laboratory that performs tests transmit band of the equipment: maximum frequency range (declared by the manufacturer) over which the transmitter can be operated without reprogramming or realignment ETSI

10 Final draft ETSI EN 302 561 V1.2.1 (2009-09)

window: set of inter-related transmissions which may be limited in time by an appropriate access protocol and corresponding occupation rules

3.2 Symbols

For the purposes of the present document, the following symbols apply:

α Filter rolloff factor dB decibel dBm dB relative to 1 mW dBμV dB relative to 1 μV f channel centre frequency

f LO Local Oscillator frequency f the frequency offset corresponding to the near edge of the receive band rb M1, M2, etc names of test signals defined in clause 6.3 PR rms power PX maximum Power (Peak Envelope Power) V minimum extreme test Voltage min V maximum extreme test Voltage max T minimum extreme test Temperature min T maximum extreme test Temperature max λ wavelength

3.3 Abbreviations

For the purposes of the present document, the following abbreviations apply:

ac alternating current ARQ Automatic Repeat reQuest BS Base Station BW BandWidth CBW Channel BandWidth CSP Channel SeParation CW Continuous Wave dBc decibels relative to the transmitter power EUT Equipment Under Test GMSK Gaussian Minimum Shift Keying IF Intermediate Frequency LBT Listen Before Transmit MBW Measurement BandWidth MS Mobile Station OATS Open Area Test Site PEP Peak Envelope Power PMR Private Mobile Radio ppm parts per million RF Radio Frequency rms root mean square RSSI Received Signal Strength Indicator Rx Receiver sr switching range Tx Transmitter VSWR Voltage Standing Wave Ratio ETSI

11 Final draft ETSI EN 302 561 V1.2.1 (2009-09)

4 General

4.1 Presentation of equipment for testing purposes

Each equipment submitted to be tested shall fulfil the requirements of the present document on all frequencies over which it is intended to operate.

The radio tests shall be performed on the lowest, the highest and the middle radio frequency channels of either the transmit or receive band of the equipment, whichever is appropriate. The provider or manufacturer shall declare the frequency ranges, the range of operating conditions and power requirements as applicable, to establish the appropriate test conditions. Information related to radio sub-system of equipment includes the transmit and receive frequency bands, first local oscillator frequency and intermediate frequencies of the receiver.

Additionally, technical documentation and operating manuals, sufficient to make the test, shall be supplied.

4.1.1 Choice of model for testing

The provider or manufacturer shall provide one or more samples of the equipment, as appropriate for testing. Stand-alone equipment shall be complete with any ancillary equipment needed for testing. If an equipment has several optional features, considered not to affect the RF parameters then the tests need only to be performed on the equipment configured with the combination of features considered to be the most complex. Where practicable, equipment to be tested shall provide a 50 Ω connector for conducted RF power level measurements. In the case of integral antenna equipment, if the equipment does not have an internal permanent 50 Ω connector then it is permissible to supply a second sample of the equipment with a temporary antenna connector fitted to facilitate testing.

The test connector shall also provide any test signalling data. The performance of the equipment to be tested shall be representative of the performance of the corresponding production model.

4.1.1.1 Auxiliary test equipment

All necessary test signal sources, setting up instructions and other product information shall accompany the equipment to be tested.

4.1.1.2 Declarations by the provider

The provider or manufacturer shall declare the necessary information of the equipment with respect to all technical requirements set by the present document.

4.2 Multi-Mode equipment

In the case of equipment supporting more than one channel bandwidth, measurements shall be performed on each channel bandwidth implemented.

ETSI

12 Final draft ETSI EN 302 561 V1.2.1 (2009-09)

4.3 Testing of equipment that does not have an external 50 Ω

RF connector (integral antenna equipment) Where equipment has an internal 50 Ω connector it shall be permitted to perform the tests at this connector. Equipment may also have a temporary internal 50 Ω connector installed for the purposes of testing. No connection shall be made to any internal permanent or temporary antenna connector during the performance of radiated emissions measurements, unless such action forms an essential part of the normal intended operation of the equipment, as declared by the manufacturer.

5 Test conditions, power sources and ambient

temperatures

5.1 Normal and extreme test conditions

Testing shall be performed under normal test conditions, and also, where stated, under extreme test conditions. The test conditions and procedures shall be as specified in clauses 5.2 to 5.5.

5.2 Test power source

During testing the power source of the equipment shall be replaced by a test power source capable of producing normal and extreme test voltages as specified in clauses 5.3.2 and 5.4.2. The internal impedance of the test power source shall be low enough for its effect on the test results to be negligible. For the purpose of tests, the voltage of the power source shall be measured at the input terminals of the equipment.

For battery operated equipment the battery shall be removed and the test power source shall be applied as close to the battery terminals as practicable.

During tests of DC powered equipment the power source voltages shall be maintained within a tolerance of < ±1 % relative to the voltage at the beginning of each test. The value of this tolerance is critical for power measurements, using a smaller tolerance will provide better measurement uncertainty values.

5.3 Normal test conditions

5.3.1 Normal temperature and humidity

The normal temperature and humidity conditions for tests shall be any convenient combination of temperature and humidity within the following ranges:

temperature: +15 °C to +35 °C; relative humidity: 20 % to 75 %.

When it is impracticable to carry out the tests under these conditions, a note to this effect, stating the ambient temperature and relative humidity during the tests, shall be added to the test report. ETSI

13 Final draft ETSI EN 302 561 V1.2.1 (2009-09)

5.3.2 Normal test power source
5.3.2.1 Mains voltage

The normal test voltage for equipment to be connected to the mains shall be the nominal mains voltage. For the purpose of the present document, the nominal voltage shall be the declared voltage or any of the declared voltages for which the equipment was designed.

The frequency of the test power source corresponding to the ac mains shall be between 49 Hz and 51 Hz.

5.3.2.2 Regulated lead-acid battery power sources used on vehicles

When the radio equipment is intended for operation from the usual types of regulated lead-acid battery power source used on vehicles the normal test voltage shall be 1,1 times the nominal voltage of the battery (for nominal voltages of 6 V and 12 V, these are 6,6 V and 13,2 V respectively).

5.3.2.3 Other power sources

For operation from other power sources or types of battery (primary or secondary), the normal test voltage shall be that declared by the equipment manufacturer.

5.4 Extreme test conditions

5.4.1 Extreme temperatures

For tests at extreme temperatures, measurements shall be made in accordance with the procedures specified in clause 5.5, at the upper and lower temperatures of one of the following two ranges:

  • -20 °C to +55 °C; All mobile and hand portable equipment.

Base stations for outdoor/uncontrolled climate conditions.

  • 0 °C to +40 °C; Base stations for indoor/controlled climate conditions.

In the case of base stations equipment, the manufacturer shall declare which conditions the equipment is intended to be installed in.

5.4.2 Extreme test source voltages
5.4.2.1 Mains voltage

The extreme test voltage for equipment to be connected to an ac mains source shall be the nominal mains voltage ±10 %.

5.4.2.2 Regulated lead-acid battery power sources used on vehicles

When the equipment is intended for operation from the usual types of regulated lead-acid battery power sources used on vehicles the extreme test voltages shall be 1,3 and 0,9 times the nominal voltage of the battery (for a nominal voltage of 6 V, these are 7,8 V and 5,4 V respectively and for a nominal voltage of 12 V, these are 15,6 V and 10,8 V respectively).

ETSI

14 Final draft ETSI EN 302 561 V1.2.1 (2009-09)

5.4.2.3 Power sources using other types of batteries

The lower extreme test voltages for equipment with power sources using batteries shall be as follows:

  • for the nickel metal-hydride, leclanché or lithium type: 0,85 times the nominal battery voltage;
  • for the mercury or nickel-cadmium type: 0,9 times the nominal battery voltage. No upper extreme test voltages apply.

In the case where no upper extreme test voltage the nominal voltage is applicable, the corresponding four extreme test conditions are:

  • V /T , V /T ; min min min max
  • (V = nominal)/T , (V = nominal)/T .

max min max max

5.4.2.4 Other power sources

For equipment using other power sources, or capable of being operated from a variety of power sources, the extreme test voltages shall be those declared by the equipment manufacturer.

5.5 Procedure for tests at extreme temperatures

Before measurements are made the equipment shall have reached thermal balance in the test chamber. The equipment shall be switched off during the temperature stabilizing period. In the case of equipment containing temperature stabilization circuits designed to operate continuously, the temperature stabilization circuits may be switched on for 15 minutes after thermal balance has been obtained, and the equipment shall then meet the specified requirements. For such equipment the manufacturer shall provide for the power source circuit feeding the crystal oven to be independent of the power source for the rest of the equipment. If the thermal balance is not checked by measurements, a temperature stabilizing period of at least one hour, or a longer period as may be decided by the testing laboratory, shall be allowed. The sequence of measurements shall be chosen, and the humidity content in the test chamber shall be controlled so that excessive condensation does not occur.

5.5.1 Procedure for equipment designed for continuous transmission

If the manufacturer states that the equipment is designed for continuous transmission, the test procedure shall be as follows.

Before tests at the upper extreme temperature, the equipment shall be placed in the test chamber, and left until thermal balance is attained. The equipment shall then be switched on in the transmit condition with modulation M1 or M2 (as appropriate, see clause 6.3.1), for a period of half an hour, after which the equipment shall meet the specified requirements.

...

Contents

  • Introduction
  • 7 ETSI EN 302 561 V1.2.1 (2009-12)
  • 1 Scope
  • 8 ETSI EN 302 561 V1.2.1 (2009-12)
  • 2 References
  • 2.1 Normative references
  • 2.2 Informative references
  • 9 ETSI EN 302 561 V1.2.1 (2009-12)
  • 3 Definitions, symbols and abbreviations
  • 3.1 Definitions
  • 10 ETSI EN 302 561 V1.2.1 (2009-12)
  • 3.2 Symbols
  • 3.3 Abbreviations
  • 11 ETSI EN 302 561 V1.2.1 (2009-12)
  • 4 General
  • 4.1 Presentation of equipment for testing purposes
  • 4.2 Multi-Mode equipment
  • 12 ETSI EN 302 561 V1.2.1 (2009-12)
  • 4.3 Testing of equipment that does not have an external 50 Ω
  • 5 Test conditions, power sources and ambient
  • 5.1 Normal and extreme test conditions
  • 5.2 Test power source
  • 5.3 Normal test conditions
  • 13 ETSI EN 302 561 V1.2.1 (2009-12)
  • 5.4 Extreme test conditions
  • 14 ETSI EN 302 561 V1.2.1 (2009-12)
  • 5.5 Procedure for tests at extreme temperatures
  • 15 ETSI EN 302 561 V1.2.1 (2009-12)
  • 6 General test conditions
  • 6.1 Arrangements for test signals applied to the receiver input
  • 6.2 Test load (artificial antenna)
  • 6.3 Test signals (wanted and unwanted signals)
  • 16 ETSI EN 302 561 V1.2.1 (2009-12)
  • 6.4 Encoder
  • 17 ETSI EN 302 561 V1.2.1 (2009-12)
  • 6.5 Transceiver data interface
  • 6.6 Impedance
  • 6.7 PEP
  • 6.8 Duplex equipment
  • 6.9 Modes of operation of the transmitter
  • 18 ETSI EN 302 561 V1.2.1 (2009-12)
  • 6.10 Measurement filter definition
  • 7 Technical characteristics of the transmitter
  • 7.1 Transmitter output power (conducted)
  • 19 ETSI EN 302 561 V1.2.1 (2009-12)
  • 7.2 Maximum effective radiated power
  • 20 ETSI EN 302 561 V1.2.1 (2009-12)
  • 21 ETSI EN 302 561 V1.2.1 (2009-12)
  • 7.3 Adjacent and alternate channel power
  • 22 ETSI EN 302 561 V1.2.1 (2009-12)
  • 23 ETSI EN 302 561 V1.2.1 (2009-12)
  • 7.4 Unwanted emissions in the spurious domain
  • 24 ETSI EN 302 561 V1.2.1 (2009-12)
  • 25 ETSI EN 302 561 V1.2.1 (2009-12)
  • 26 ETSI EN 302 561 V1.2.1 (2009-12)
  • 30 MHz to 1 GHz 100 kHz
  • 1 GHz to 12,75 GHz 1 MHz
  • 27 ETSI EN 302 561 V1.2.1 (2009-12)
  • 28 ETSI EN 302 561 V1.2.1 (2009-12)
  • 7.5 Intermodulation attenuation
  • 29 ETSI EN 302 561 V1.2.1 (2009-12)
  • 7.6 Adjacent channel transient power measurements
  • 30 ETSI EN 302 561 V1.2.1 (2009-12)
  • 7.7 Frequency error
  • 31 ETSI EN 302 561 V1.2.1 (2009-12)
  • 8 Technical characteristics of the receiver
  • 8.1 Receiver sensitivity (conducted)
  • 32 ETSI EN 302 561 V1.2.1 (2009-12)
  • 33 ETSI EN 302 561 V1.2.1 (2009-12)
  • 8.2 Maximum usable sensitivity (field strength)
  • 34 ETSI EN 302 561 V1.2.1 (2009-12)
  • 35 ETSI EN 302 561 V1.2.1 (2009-12)
  • 36 ETSI EN 302 561 V1.2.1 (2009-12)
  • 37 ETSI EN 302 561 V1.2.1 (2009-12)
  • 8.3 Blocking or desensitization
  • 38 ETSI EN 302 561 V1.2.1 (2009-12)
  • 39 ETSI EN 302 561 V1.2.1 (2009-12)
  • 40 ETSI EN 302 561 V1.2.1 (2009-12)
  • 8.4 Adjacent channel selectivity
  • 41 ETSI EN 302 561 V1.2.1 (2009-12)

Introduction

The present document is part of a set of standards developed by ETSI and is designed to fit in a modular structure to cover all radio and telecommunications terminal equipment within the scope of the R&TTE Directive [i.4]. The modular structure is shown in EG 201 399 [i.3].

ETSI

7 ETSI EN 302 561 V1.2.1 (2009-12)

1 Scope

The present document covers the technical requirements for radio transmitters and receivers used in stations in the Private Mobile Radio (PMR) service.

It applies to use in the land mobile service, operating on radio frequencies between 30 MHz and 3 GHz, with channel separations of 25 kHz, 50 kHz, 100 kHz and 150 kHz.

Table 1: Radiocommunications service frequency bands Radiocommunications service frequency bands Transmit 30 MHz to 3 000 MHz Receive 30 MHz to 3 000 MHz

It applies to equipment for continuous and/or discontinuous transmission of data and/or digital speech. The equipment comprises a transmitter and associated encoder and modulator and/or a receiver and associated demodulator and decoder. The types of equipment covered by the present document are as follows:

  • base station (equipment fitted with an antenna connector, intended for use in a fixed location);
  • mobile station (equipment fitted with an antenna connector, normally used in a vehicle or as a transportable);
  • and those hand portable stations:

a) fitted with an antenna connector; or b) without an external antenna connector (integral antenna equipment), but fitted with a permanent internal or a temporary internal 50 Ω Radio Frequency (RF) connector which allows access to the transmitter output and the receiver input.

Hand portable equipment without an external or internal RF connector and without the possibility of having a temporary internal 50 Ω RF connector is not covered by the present document. These specifications do not necessarily include all the characteristics which may be required by a user of equipment, nor do they necessarily represent the optimum performance achievable. The present document is intended to cover the provisions of article 3.2 of Directive 1999/5/EC [i.4] (R&TTE Directive), which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive [i.4] may apply to equipment within the scope of the present document.

NOTE: A list of such ENs is included on the web site http://www.newapproach.org. ETSI

8 ETSI EN 302 561 V1.2.1 (2009-12)

2 References

References are either specific (identified by date of publication and/or edition number or version number) or non-specific.

  • For a specific reference, subsequent revisions do not apply.
  • Non-specific reference may be made only to a complete document or a part thereof and only in the following cases:
  • if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document;
  • for informative references.

Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.

NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity.

2.1 Normative references

The following referenced documents are indispensable for the application of the present document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies.

[1] ITU-T Recommendation O.153 (1992): "Basic parameters for the measurement of error performance at bit rates below the primary rate".

[2] ETSI TR 100 028 (V1.4.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics". [3] ETSI TR 102 273 (V1.2.1) (all parts): "Electromagnetic compatibility and Radio spectrum Matters (ERM); Improvement on Radiated Methods of Measurement (using test site) and evaluation of the corresponding measurement uncertainties".

[4] ANSI C63.5 (2004): "American National Standard for Electromagnetic Compatibility-Radiated Emission Measurements in Electromagnetic Interference (EMI) Control-Calibration of Antennas (9 kHz to 40 GHz)".

[5] ETSI EN 300 392-2 (V3.2.1): "Terrestrial Trunked Radio (TETRA); Voice plus Data (V+D); Part 2: Air Interface (AI)".

2.2 Informative references

The following referenced documents are not essential to the use of the present document but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the referenced document (including any amendments) applies.

[i.1] ITU-R Recommendation SM.329-10 (2003): "Unwanted emissions in the spurious domain". [i.2] CEPT/ERC/REC 74-01 (2005): "Unwanted Emissions in the Spurious domain". [i.3] ETSI EG 201 399 (V2.1.1): "Electromagnetic compatibility and Radio spectrum Matters (ERM); A guide to the production of candidate Harmonized Standards for application under the R&TTE Directive".

[i.4] Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R&TTE Directive).

ETSI

9 ETSI EN 302 561 V1.2.1 (2009-12)

[i.5] Directive 98/34/EC of the European Parliament and of the Council of 22 June 1998 laying down a procedure for the provision of information in the field of technical standards and regulations.

3 Definitions, symbols and abbreviations

3.1 Definitions

For the purposes of the present document, the following terms and definitions apply:

base station: equipment fitted with an antenna connector, for use with an external antenna, and intended for use in a fixed location bit: binary digit block: the smallest quantity of information that is sent over the radio channel NOTE: A constant number of useful bits are always sent together with the corresponding redundancy bits. burst or transmission (physical): one or several packets transmitted between power on and power off of a particular transmitter conducted measurements: measurements which are made using direct 50 Ω connection to the equipment under test data transmission systems: systems which transmit and/or receive data and/or digitized voice hand portable station: equipment either fitted with an antenna connector or integral antenna, or both, normally used on a stand-alone basis, to be carried on a person or held in the hand integral antenna: antenna designed to be connected to the equipment without the use of a 50 Ω external connector and considered to be part of the equipment NOTE: An integral antenna may be fitted internally or externally to the equipment. Listen Before Transmit mode (LBT): monitoring mode in which the RF channel is checked for activity before transmitting NOTE: Examples for LBT are transceivers or systems implementing squelch or RSSI (Receiver Signal Strength Indicator) algorithms for evaluating the status of the channel. message: user data to be transferred in one or more packets in a session mobile station: mobile equipment fitted with an antenna connector, for use with an external antenna, normally used in a vehicle or as a transportable station packet: one block or a contiguous stream of blocks sent by one (logical) transmitter to one particular receiver or one particular group of receivers radiated measurements: measurements which involve the absolute measurement of a radiated field receive band of the equipment: maximum frequency range (declared by the manufacturer) over which the receiver can be operated without reprogramming or realignment session: set of inter-related exchange of packets occupying one or several windows or part thereof (if applicable) NOTE: It corresponds to a complete interactive procedure for interchanging data between users, comprising initiation, data transmission and termination procedures. The session can be short (e.g. 2 packets), or long (e.g. one full page of text).

spurious emissions: unwanted emissions in the spurious domain switching range (sr): maximum frequency range, as specified by the manufacturer, over which the receiver or the transmitter can be operated within the alignment range without reprogramming or realignment ETSI

10 ETSI EN 302 561 V1.2.1 (2009-12)

testing laboratory: laboratory that performs tests transmit band of the equipment: maximum frequency range (declared by the manufacturer) over which the transmitter can be operated without reprogramming or realignment window: set of inter-related transmissions which may be limited in time by an appropriate access protocol and corresponding occupation rules

3.2 Symbols

For the purposes of the present document, the following symbols apply:

α Filter rolloff factor dB decibel dBm dB relative to 1 mW dBμV dB relative to 1 μV f channel centre frequency

f LO Local Oscillator frequency f the frequency offset corresponding to the near edge of the receive band rb M1, M2, etc names of test signals defined in clause 6.3 PR rms power PX maximum Power (Peak Envelope Power) V minimum extreme test Voltage min V maximum extreme test Voltage max T minimum extreme test Temperature min T maximum extreme test Temperature max λ wavelength

3.3 Abbreviations

For the purposes of the present document, the following abbreviations apply:

ac alternating current ARQ Automatic Repeat reQuest BS Base Station BW BandWidth CBW Channel BandWidth CSP Channel SeParation CW Continuous Wave dBc decibels relative to the transmitter power EUT Equipment Under Test GMSK Gaussian Minimum Shift Keying IF Intermediate Frequency LBT Listen Before Transmit MBW Measurement BandWidth MS Mobile Station OATS Open Area Test Site PEP Peak Envelope Power PMR Private Mobile Radio ppm parts per million RF Radio Frequency rms root mean square RSSI Received Signal Strength Indicator Rx Receiver sr switching range Tx Transmitter VSWR Voltage Standing Wave Ratio ETSI

11 ETSI EN 302 561 V1.2.1 (2009-12)

4 General

4.1 Presentation of equipment for testing purposes

Each equipment submitted to be tested shall fulfil the requirements of the present document on all frequencies over which it is intended to operate.

The radio tests shall be performed on the lowest, the highest and the middle radio frequency channels of either the transmit or receive band of the equipment, whichever is appropriate. The provider or manufacturer shall declare the frequency ranges, the range of operating conditions and power requirements as applicable, to establish the appropriate test conditions. Information related to radio sub-system of equipment includes the transmit and receive frequency bands, first local oscillator frequency and intermediate frequencies of the receiver.

Additionally, technical documentation and operating manuals, sufficient to make the test, shall be supplied.

4.1.1 Choice of model for testing

The provider or manufacturer shall provide one or more samples of the equipment, as appropriate for testing. Stand-alone equipment shall be complete with any ancillary equipment needed for testing. If an equipment has several optional features, considered not to affect the RF parameters then the tests need only to be performed on the equipment configured with the combination of features considered to be the most complex. Where practicable, equipment to be tested shall provide a 50 Ω connector for conducted RF power level measurements. In the case of integral antenna equipment, if the equipment does not have an internal permanent 50 Ω connector then it is permissible to supply a second sample of the equipment with a temporary antenna connector fitted to facilitate testing.

The test connector shall also provide any test signalling data. The performance of the equipment to be tested shall be representative of the performance of the corresponding production model.

4.1.1.1 Auxiliary test equipment

All necessary test signal sources, setting up instructions and other product information shall accompany the equipment to be tested.

4.1.1.2 Declarations by the provider

The provider or manufacturer shall declare the necessary information of the equipment with respect to all technical requirements set by the present document.

4.2 Multi-Mode equipment

In the case of equipment supporting more than one channel bandwidth, measurements shall be performed on each channel bandwidth implemented.

ETSI

12 ETSI EN 302 561 V1.2.1 (2009-12)

4.3 Testing of equipment that does not have an external 50 Ω

RF connector (integral antenna equipment) Where equipment has an internal 50 Ω connector it shall be permitted to perform the tests at this connector. Equipment may also have a temporary internal 50 Ω connector installed for the purposes of testing. No connection shall be made to any internal permanent or temporary antenna connector during the performance of radiated emissions measurements, unless such action forms an essential part of the normal intended operation of the equipment, as declared by the manufacturer.

5 Test conditions, power sources and ambient

temperatures

5.1 Normal and extreme test conditions

Testing shall be performed under normal test conditions, and also, where stated, under extreme test conditions. The test conditions and procedures shall be as specified in clauses 5.2 to 5.5.

5.2 Test power source

During testing the power source of the equipment shall be replaced by a test power source capable of producing normal and extreme test voltages as specified in clauses 5.3.2 and 5.4.2. The internal impedance of the test power source shall be low enough for its effect on the test results to be negligible. For the purpose of tests, the voltage of the power source shall be measured at the input terminals of the equipment.

For battery operated equipment the battery shall be removed and the test power source shall be applied as close to the battery terminals as practicable.

During tests of DC powered equipment the power source voltages shall be maintained within a tolerance of < ±1 % relative to the voltage at the beginning of each test. The value of this tolerance is critical for power measurements, using a smaller tolerance will provide better measurement uncertainty values.

5.3 Normal test conditions

5.3.1 Normal temperature and humidity

The normal temperature and humidity conditions for tests shall be any convenient combination of temperature and humidity within the following ranges:

temperature: +15 °C to +35 °C; relative humidity: 20 % to 75 %.

When it is impracticable to carry out the tests under these conditions, a note to this effect, stating the ambient temperature and relative humidity during the tests, shall be added to the test report. ETSI

13 ETSI EN 302 561 V1.2.1 (2009-12)

5.3.2 Normal test power source
5.3.2.1 Mains voltage

The normal test voltage for equipment to be connected to the mains shall be the nominal mains voltage. For the purpose of the present document, the nominal voltage shall be the declared voltage or any of the declared voltages for which the equipment was designed.

The frequency of the test power source corresponding to the ac mains shall be between 49 Hz and 51 Hz.

5.3.2.2 Regulated lead-acid battery power sources used on vehicles

When the radio equipment is intended for operation from the usual types of regulated lead-acid battery power source used on vehicles the normal test voltage shall be 1,1 times the nominal voltage of the battery (for nominal voltages of 6 V and 12 V, these are 6,6 V and 13,2 V respectively).

5.3.2.3 Other power sources

For operation from other power sources or types of battery (primary or secondary), the normal test voltage shall be that declared by the equipment manufacturer.

5.4 Extreme test conditions

5.4.1 Extreme temperatures

For tests at extreme temperatures, measurements shall be made in accordance with the procedures specified in clause 5.5, at the upper and lower temperatures of one of the following two ranges:

  • -20 °C to +55 °C; All mobile and hand portable equipment.

Base stations for outdoor/uncontrolled climate conditions.

  • 0 °C to +40 °C; Base stations for indoor/controlled climate conditions.

In the case of base stations equipment, the manufacturer shall declare which conditions the equipment is intended to be installed in.

5.4.2 Extreme test source voltages
5.4.2.1 Mains voltage

The extreme test voltage for equipment to be connected to an ac mains source shall be the nominal mains voltage ±10 %.

5.4.2.2 Regulated lead-acid battery power sources used on vehicles

When the equipment is intended for operation from the usual types of regulated lead-acid battery power sources used on vehicles the extreme test voltages shall be 1,3 and 0,9 times the nominal voltage of the battery (for a nominal voltage of 6 V, these are 7,8 V and 5,4 V respectively and for a nominal voltage of 12 V, these are 15,6 V and 10,8 V respectively).

ETSI

14 ETSI EN 302 561 V1.2.1 (2009-12)

5.4.2.3 Power sources using other types of batteries

The lower extreme test voltages for equipment with power sources using batteries shall be as follows:

  • for the nickel metal-hydride, leclanché or lithium type: 0,85 times the nominal battery voltage;
  • for the mercury or nickel-cadmium type: 0,9 times the nominal battery voltage. No upper extreme test voltages apply.

In the case where no upper extreme test voltage the nominal voltage is applicable, the corresponding four extreme test conditions are:

  • V /T , V /T ; min min min max
  • (V = nominal)/T , (V = nominal)/T .

max min max max

5.4.2.4 Other power sources

For equipment using other power sources, or capable of being operated from a variety of power sources, the extreme test voltages shall be those declared by the equipment manufacturer.

5.5 Procedure for tests at extreme temperatures

Before measurements are made the equipment shall have reached thermal balance in the test chamber. The equipment shall be switched off during the temperature stabilizing period. In the case of equipment containing temperature stabilization circuits designed to operate continuously, the temperature stabilization circuits may be switched on for 15 minutes after thermal balance has been obtained, and the equipment shall then meet the specified requirements. For such equipment the manufacturer shall provide for the power source circuit feeding the crystal oven to be independent of the power source for the rest of the equipment. If the thermal balance is not checked by measurements, a temperature stabilizing period of at least one hour, or a longer period as may be decided by the testing laboratory, shall be allowed. The sequence of measurements shall be chosen, and the humidity content in the test chamber shall be controlled so that excessive condensation does not occur.

5.5.1 Procedure for equipment designed for continuous transmission

If the manufacturer states that the equipment is designed for continuous transmission, the test procedure shall be as follows.

Before tests at the upper extreme temperature, the equipment shall be placed in the test chamber, and left until thermal balance is attained. The equipment shall then be switched on in the transmit condition with modulation M1 or M2 (as appropriate, see clause 6.3.1), for a period of half an hour, after which the equipment shall meet the specified requirements.

...


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Electromagnetic compatibility and Radio spectrum Matters (ERM) - Land Mobile Service - Radio equipment using constant or non-constant envelope modulation operating in a channel bandwidth of 25 kHz, 50 kHz, 100 kHz or 150 kHz - Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive33.100.01Elektromagnetna združljivost na splošnoElectromagnetic compatibility in general33.070.01Mobilni servisi na splošnoMobile services in general33.060.99Druga oprema za radijske komunikacijeOther equipment for radiocommunicationsICS:Ta slovenski standard je istoveten z:EN 302 561 Version 1.2.1SIST EN 302 561 V1.2.1:2010en01-februar-2010SIST EN 302 561 V1.2.1:2010SLOVENSKI
STANDARD
ETSI ETSI EN 302 561 V1.2.1 (2009-12) 2
Reference REN/ERM-TGDMR-277 Keywords data, mobile, PMR, radio ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C Association à but non lucratif enregistrée à la Sous-Préfecture de Grasse (06) N° 7803/88
Important notice Individual copies of the present document can be downloaded from: http://www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http://portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http://portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2009. All rights reserved.
DECTTM, PLUGTESTSTM, UMTSTM, TIPHONTM, the TIPHON logo and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. LTE™ is a Trade Mark of ETSI currently being registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association. SIST EN 302 561 V1.2.1:2010

ETSI ETSI EN 302 561 V1.2.1 (2009-12) 3 Contents Intellectual Property Rights . 6 Foreword . 6 Introduction . 6 1 Scope . 7 2 References . 8 2.1 Normative references . 8 2.2 Informative references . 8 3 Definitions, symbols and abbreviations . 9 3.1 Definitions . 9 3.2 Symbols . 10 3.3 Abbreviations . 10 4 General . 11 4.1 Presentation of equipment for testing purposes . 11 4.1.1 Choice of model for testing . 11 4.1.1.1 Auxiliary test equipment . 11 4.1.1.2 Declarations by the provider . 11 4.2 Multi-Mode equipment . 11 4.3 Testing of equipment that does not have an external 50 Ω RF connector (integral antenna equipment) . 12 5 Test conditions, power sources and ambient temperatures . 12 5.1 Normal and extreme test conditions . 12 5.2 Test power source . 12 5.3 Normal test conditions . 12 5.3.1 Normal temperature and humidity . 12 5.3.2 Normal test power source . 13 5.3.2.1 Mains voltage . 13 5.3.2.2 Regulated lead-acid battery power sources used on vehicles . 13 5.3.2.3 Other power sources . 13 5.4 Extreme test conditions . 13 5.4.1 Extreme temperatures . 13 5.4.2 Extreme test source voltages . 13 5.4.2.1 Mains voltage . 13 5.4.2.2 Regulated lead-acid battery power sources used on vehicles . 13 5.4.2.3 Power sources using other types of batteries . 14 5.4.2.4 Other power sources . 14 5.5 Procedure for tests at extreme temperatures . 14 5.5.1 Procedure for equipment designed for continuous transmission. 14 5.5.2 Procedure for equipment designed for intermittent transmission . 14 6 General test conditions . 15 6.1 Arrangements for test signals applied to the receiver input . 15 6.2 Test load (artificial antenna) . 15 6.3 Test signals (wanted and unwanted signals) . 15 6.3.1 Transmitter test signals . 15 6.3.2 Receiver test signals. 16 6.3.3 Transmitter effective radiated power test signal (C1) . 16 6.4 Encoder . 16 6.4.1 Encoder for receiver measurements . 16 6.4.2 Encoder for transmitter measurements . 17 6.5 Transceiver data interface. 17 6.6 Impedance . 17 6.7 PEP . 17 6.8 Duplex equipment . 17 6.9 Modes of operation of the transmitter . 17 SIST EN 302 561 V1.2.1:2010
...