SIST EN 302 066-2 V1.1.1:2006
(Main)Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Ground- and Wall- Probing Radar applications; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive
- Abstract
The present document specifies the requirements for Ground- and Wall- Probing Radar applications operating in all or part of the frequency band from 30 MHz to 12,4 GHz. Ground Probing Radars (GPR) and Wall Probing Radars (WPR) are used in survey and detection applications. The scope is limited to radars operated as short range devices (because of their usage and design), in which the system is in close proximity to the materials being investigated. It does not include radars operated from aircraft or spacecraft. The radar applications in the present document are not intended for communications purposes. Their intended usage excludes radiation into the free space and means shall be taken to keep it to a minimum.
NOTE 1: Equipment using the frequencies typically below 100 MHz may use higher output power for geophysical applications and therefore, may not fulfil the emission requirements set out in the present document.
NOTE 2: Equipment covered by the present document is used by competent professional personnel. The present document applies to:
• Ground Probing Radars (GPR) operating over approximately one decade in the frequency range 30 MHz to 12,4 GHz radiating directly downwards into the ground. Any horizontal radiation from this equipment is caused by leakage and is considered as undesired emission.
• Wall Probing Radars (WPR) operating in the frequency range 30 MHz to 12,4 GHz radiating directly into a "wall". The "wall" is a building material structure, the side of a bridge, the wall of a mine or another physical structure that absorbs a significant part of the signal transmitted by the radar.
• Equipment fitted with integral antennas and without antenna connector.
• Equipment which uses different imaging heads (antennas) with an antenna connector, to allow operation at different frequencies.
The document does not necessarily include all the characteristics which may be required by a user, nor does it necessarily represent the optimum performance achievable.
The present document contains the technical characteristics and test methods for Ground- and Wall- Probing Radar applications.
The present document is intended to cover the provisions of Directive 1999/5/EC [1] (R&TTE Directive) article 3.2, which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive [1] will apply to equipment within the scope of the present document. The document responds to the EC mandate M/329 for Harmonized Standards covering Ultra-WideBand (UWB) applications [5].
- Status
- Published
- Publication Date
- 28-Feb-2006
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Mar-2006
- Due Date
- 01-Mar-2006
- Completion Date
- 01-Mar-2006
- Mandate
- M/284
SIST EN 302 066-2 V1.1.1:2006 is the Slovenian adoption of ETSI EN 302 066-2 V1.1.1, published by SIST. It covers Ground- and Wall-Probing Radar applications and specifies the radio-spectrum requirements and test methods used to show conformity with article 3.2 of the R&TTE Directive. It is aimed at equipment used by competent professional personnel for survey and detection work.
What does SIST EN 302 066-2 V1.1.1:2006 specify?
SIST EN 302 066-2 V1.1.1:2006 specifies requirements for Ground- and Wall-Probing Radar applications operating in all or part of the 30 MHz to 12.4 GHz band. The document is limited to short-range radar used close to the material being investigated, and it excludes radars operated from aircraft or spacecraft and use for communications purposes.
The standard is organized into five clauses plus two annexes:
| Clause / annex | What it covers |
|---|---|
| Clause 1 | Scope |
| Clause 2 | References |
| Clause 3 | Definitions, symbols and abbreviations |
| Clause 4 | Technical requirements specifications |
| Clause 5 | Testing for compliance with technical requirements |
| Annex A | EN Requirements Table (EN-RT) |
| Annex B | EN title in the official languages |
Annex A is the conformity-assessment table, and Annex B gives the title in many European languages.
What are the key requirements of SIST EN 302 066-2 V1.1.1:2006?
The core of SIST EN 302 066-2 V1.1.1:2006 is in Clause 4 and Clause 5. It ties the radar's declared operating conditions to the limits and tests in ETSI EN 302 066-1, so a user must verify both the intended operating range and the emitted radiation under the declared conditions.
Operating conditions
Clause 4.1 says the equipment has to meet the requirements within the declared environmental profile. In practice, the provider has to declare the environmental conditions for operation, and compliance has to hold anywhere inside those limits.
Clause 4.1.2 extends that idea to power supply conditions. The equipment has to satisfy the requirements over all declared operating power-supply conditions, whether it uses an external battery or a stabilized supply. That matters because the same radar may be used in different field setups.
Spectrum use and emissions
Clause 4.2.1 requires the frequency band of operation to stay within the limits in EN 302 066-1, clause 8.1.3. Clause 5.2.1 points to the corresponding test in EN 302 066-1, clause 8.1.2. In practice, this means the transmitter has to be checked against its intended band of operation.
Clause 4.2.2 requires undesired emissions to stay within the limits in EN 302 066-1, clause 8.2.3, and Clause 5.2.2 points to the test in clause 8.2.2. This is important because Ground- and Wall-Probing Radar is intended to radiate mainly into the ground or wall, with leakage and other unwanted radiation kept to a minimum.
Deactivation and testing
Clause 4.2.3 says the deactivation mechanism requirements are defined in EN 302 066-1, Annex B. Annex A marks this as a mandatory EN requirement, so the disable or shut-off function has to be considered in conformity assessment.
Clause 5.1 requires testing at representative points within the declared environmental profile, and at enough different conditions when performance changes with the environment. Clause 5.3 then sends users to EN 302 066-1, clause 4.5, for interpretation of results and measurement uncertainty. That means pass/fail decisions must use the same uncertainty treatment as the companion part.
Annex A turns these requirements into an EN Requirements Table (EN-RT) for static conformity assessment. It lists frequency range of operation, emissions, and deactivation mechanism requirements as mandatory entries.
What terms does SIST EN 302 066-2 V1.1.1:2006 define?
- Environmental profile - the range of environmental conditions under which the equipment must comply with the standard.
- Ground Probing Radars (GPR) - radars that radiate directly downward into the ground for survey and detection work.
- Wall Probing Radars (WPR) - radars that radiate into a wall or another physical structure that absorbs a significant part of the signal.
- EN Requirements Table (EN-RT) - the tabular summary used to record the requirements and support conformity assessment.
- Deactivation mechanism - the function covered by EN 302 066-1, Annex B, for disabling the equipment.
- Measurement uncertainty - the uncertainty treatment used when interpreting test results for compliance.
Who uses SIST EN 302 066-2 V1.1.1:2006?
SIST EN 302 066-2 V1.1.1:2006 is used by manufacturers and providers of GPR and WPR equipment, compliance engineers, and test laboratories. It is also relevant to professional users in survey and detection applications who need equipment matched to the declared operating conditions and spectrum limits.
Buyers and quality managers use it to check whether a radar product is the right type of short-range device and what evidence should exist for conformity assessment.
Which standards are used with SIST EN 302 066-2 V1.1.1:2006?
| Reference | What it contributes |
|---|---|
| Directive 1999/5/EC (R&TTE Directive) | The legal framework for article 3.2 spectrum use that this standard addresses. |
| ETSI EN 302 066-1 | The companion part that supplies technical characteristics, definitions, symbols, abbreviations, limits, test clauses, measurement uncertainty rules, and Annex B on deactivation mechanisms. |
| EC Mandate M/329 | The mandate for Harmonized Standards covering Ultra-WideBand (UWB) applications. |
| Directive 98/34/EC | The procedure for notifying technical standards and regulations, cited in the foreword. |
What does the SIST EN 302 066-2 V1.1.1:2006 document contain?
The document contains the scope, the reference list, definitions, technical requirements, and compliance test clauses for Ground- and Wall-Probing Radar applications. It also includes a modular-structure figure showing how article 3.2 standards fit into the R&TTE framework.
Annex A provides the EN Requirements Table for conformity assessment, and Annex B gives the title in official languages. The document also includes the publication history and the ETSI foreword that explains its harmonized-standard context.
Relations
- Official Journal Project Relation
SIST EN 302 066-2 V1.2.1:2008 - Electromagnetic compatibility and Radio spectrum Matters (ERM) - Ground- and Wall- Probing Radar applications (GPR/WPR) imaging systems - Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive - Effective Date
- 25-Jan-2010
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 302 066-2 V1.1.1:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Ground- and Wall- Probing Radar applications; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive". This standard covers: The present document specifies the requirements for Ground- and Wall- Probing Radar applications operating in all or part of the frequency band from 30 MHz to 12,4 GHz. Ground Probing Radars (GPR) and Wall Probing Radars (WPR) are used in survey and detection applications. The scope is limited to radars operated as short range devices (because of their usage and design), in which the system is in close proximity to the materials being investigated. It does not include radars operated from aircraft or spacecraft. The radar applications in the present document are not intended for communications purposes. Their intended usage excludes radiation into the free space and means shall be taken to keep it to a minimum. NOTE 1: Equipment using the frequencies typically below 100 MHz may use higher output power for geophysical applications and therefore, may not fulfil the emission requirements set out in the present document. NOTE 2: Equipment covered by the present document is used by competent professional personnel. The present document applies to: • Ground Probing Radars (GPR) operating over approximately one decade in the frequency range 30 MHz to 12,4 GHz radiating directly downwards into the ground. Any horizontal radiation from this equipment is caused by leakage and is considered as undesired emission. • Wall Probing Radars (WPR) operating in the frequency range 30 MHz to 12,4 GHz radiating directly into a "wall". The "wall" is a building material structure, the side of a bridge, the wall of a mine or another physical structure that absorbs a significant part of the signal transmitted by the radar. • Equipment fitted with integral antennas and without antenna connector. • Equipment which uses different imaging heads (antennas) with an antenna connector, to allow operation at different frequencies. The document does not necessarily include all the characteristics which may be required by a user, nor does it necessarily represent the optimum performance achievable. The present document contains the technical characteristics and test methods for Ground- and Wall- Probing Radar applications. The present document is intended to cover the provisions of Directive 1999/5/EC [1] (R&TTE Directive) article 3.2, which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive [1] will apply to equipment within the scope of the present document. The document responds to the EC mandate M/329 for Harmonized Standards covering Ultra-WideBand (UWB) applications [5].
The present document specifies the requirements for Ground- and Wall- Probing Radar applications operating in all or part of the frequency band from 30 MHz to 12,4 GHz. Ground Probing Radars (GPR) and Wall Probing Radars (WPR) are used in survey and detection applications. The scope is limited to radars operated as short range devices (because of their usage and design), in which the system is in close proximity to the materials being investigated. It does not include radars operated from aircraft or spacecraft. The radar applications in the present document are not intended for communications purposes. Their intended usage excludes radiation into the free space and means shall be taken to keep it to a minimum. NOTE 1: Equipment using the frequencies typically below 100 MHz may use higher output power for geophysical applications and therefore, may not fulfil the emission requirements set out in the present document. NOTE 2: Equipment covered by the present document is used by competent professional personnel. The present document applies to: • Ground Probing Radars (GPR) operating over approximately one decade in the frequency range 30 MHz to 12,4 GHz radiating directly downwards into the ground. Any horizontal radiation from this equipment is caused by leakage and is considered as undesired emission. • Wall Probing Radars (WPR) operating in the frequency range 30 MHz to 12,4 GHz radiating directly into a "wall". The "wall" is a building material structure, the side of a bridge, the wall of a mine or another physical structure that absorbs a significant part of the signal transmitted by the radar. • Equipment fitted with integral antennas and without antenna connector. • Equipment which uses different imaging heads (antennas) with an antenna connector, to allow operation at different frequencies. The document does not necessarily include all the characteristics which may be required by a user, nor does it necessarily represent the optimum performance achievable. The present document contains the technical characteristics and test methods for Ground- and Wall- Probing Radar applications. The present document is intended to cover the provisions of Directive 1999/5/EC [1] (R&TTE Directive) article 3.2, which states that "… radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communications and orbital resources so as to avoid harmful interference". In addition to the present document, other ENs that specify technical requirements in respect of essential requirements under other parts of article 3 of the R&TTE Directive [1] will apply to equipment within the scope of the present document. The document responds to the EC mandate M/329 for Harmonized Standards covering Ultra-WideBand (UWB) applications [5].
SIST EN 302 066-2 V1.1.1:2006 is classified under the following ICS (International Classification for Standards) categories: 33.060.99 - Other equipment for radiocommunications; 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 302 066-2 V1.1.1:2006 has the following relationships with other standards: It is inter standard links to SIST EN 302 066-2 V1.2.1:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 302 066-2 V1.1.1:2006 is associated with the following European legislation: EU Directives/Regulations: 1999/5/EC; Standardization Mandates: M/284. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 302 066-2 V1.1.1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 3.2 New radio harmonized standards
- 6 ETSI EN 302 066-2 V1.1.1 (2005-09)
- 7 ETSI EN 302 066-2 V1.1.1 (2005-09)
- 1 Scope
- 8 ETSI EN 302 066-2 V1.1.1 (2005-09)
- 2 References
- 3 Definitions, symbols and abbreviations
- 3.1 Definitions
- 3.2 Symbols
- 3.3 Abbreviations
- 9 ETSI EN 302 066-2 V1.1.1 (2005-09)
- 4 Technical requirements specifications
- 4.1 Environmental conditions
- 4.2 Conformance requirements
- 5 Testing for compliance with technical requirements
- 5.1 Environmental conditions for testing
- 5.2 Essential radio test suites
- 10 ETSI EN 302 066-2 V1.1.1 (2005-09)
- 5.3 Interpretation of results and measurement uncertainty
- 11 ETSI EN 302 066-2 V1.1.1 (2005-09)
- 12 ETSI EN 302 066-2 V1.1.1 (2005-09)
- 13 ETSI EN 302 066-2 V1.1.1 (2005-09)
Introduction
The present document is part of a set of standards designed to fit in a modular structure to cover all radio and telecommunications terminal equipment under the R&TTE Directive [1]. Each standard is a module in the structure. The modular structure is shown in figure 1.
Disability* 3.3f Emergency* 3.3e Fraud* 3.3d 3.3c Privacy* No harm to the network* 3.3b * If needed Scoped by Inter-working via the network* equipment 3.3a class or type Inter-working with the network Use of spectrum
3.2 New radio harmonized standards
Spectrum Scoped by frequency and/or equipment type Radio Product EMC EN 301 489 multi-part EMC standard 3.1b EMC Generic and product standards also notified under EMC Directive - If needed, new standards for human exposure to Electromagnetic Fields, - if needed, new standards for acoustic safety 3.1a Standards also notified under LV Directive Safety Non-radio Radio (RE) TTE Non-TTE
Figure 1: Modular structure for the various standards used under the R&TTE Directive [1] ETSI
SIST EN 302 066-2 V1.1.1:2006
6 ETSI EN 302 066-2 V1.1.1 (2005-09)
The left hand edge of the figure 1 shows the different clauses of article 3 of the R&TTE Directive [1]. For article 3.3 various horizontal boxes are shown. Dotted lines indicate that at the time of publication of the present document essential requirements in these areas have to be adopted by the Commission. If such essential requirements are adopted, and as far and as long as they are applicable, they will justify individual standards whose scope is likely to be specified by function or interface type.
The vertical boxes show the standards under article 3.2 for the use of the radio spectrum by radio equipment. The scopes of these standards are specified either by frequency (normally in the case where frequency bands are harmonized) or by radio equipment type.
For article 3.1b the diagram shows EN 301 489, the multi-part product EMC standard for radio used under the EMC Directive [2].
For article 3.1a the diagram shows the existing safety standards currently used under the LV Directive [3] and new standards covering human exposure to electromagnetic fields. New standards covering acoustic safety may also be required.
The bottom of the figure shows the relationship of the standards to radio equipment and telecommunications terminal equipment. Particular equipment may be radio equipment, telecommunications terminal equipment or both. A radio spectrum standard will apply if it is radio equipment. An article 3.3 standard will apply as well only if the relevant essential requirement under the R&TTE Directive [1] is adopted by the Commission and if the equipment in question is covered by the scope of the corresponding standard. Thus, depending on the nature of the equipment, the essential requirements under the R&TTE Directive [1] may be covered in a set of standards. The modularity principle has been taken because:
- it minimizes the number of standards needed. Because equipment may, in fact, have multiple interfaces and functions it is not practicable to produce a single standard for each possible combination of functions that may occur in an equipment;
- it provides scope for standards to be added:
- under article 3.2 when new frequency bands are agreed; or
- under article 3.3 should the Commission take the necessary decisions without requiring alteration of standards that are already published;
- it clarifies, simplifies and promotes the usage of Harmonized Standards as the relevant means of conformity assessment.
ETSI
SIST EN 302 066-2 V1.1.1:2006
7 ETSI EN 302 066-2 V1.1.1 (2005-09)
1 Scope
The present document specifies the requirements for Ground- and Wall- Probing Radar applications operating in all or part of the frequency band from 30 MHz to 12,4 GHz.
Ground Probing Radars (GPR) and Wall Probing Radars (WPR) are used in survey and detection applications. The scope is limited to radars operated as short range devices (because of their usage and design), in which the system is in close proximity to the materials being investigated. It does not include radars operated from aircraft or spacecraft. The radar applications in the present document are not intended for communications purposes. Their intended usage excludes radiation into the free space and means shall be taken to keep it to a minimum. NOTE 1: Equipment using the frequencies typically below 100 MHz may use higher output power for geophysical applications and therefore, may not fulfil the emission requirements set out in the present document. NOTE 2: Equipment covered by the present document is used by competent professional personnel. The present document applies to:
- Ground Probing Radars (GPR) operating over approximately one decade in the frequency range 30 MHz to 12,4 GHz radiating directly downwards into the ground. Any horizontal radiation from this equipment is caused by leakage and is considered as undesired emission.
- Wall Probing Radars (WPR) operating in the frequency range 30 MHz to 12,4 GHz radiating directly into a "wall". The "wall" is a building material structure, the side of a bridge, the wall of a mine or another physical structure that absorbs a significant part of the signal transmitted by the radar.
- Equipment fitted with integral antennas and without antenna connector.
- Equipment which uses different imaging heads (antennas) with an antenna connector, to allow operation at different frequencies.
The document does not necessarily include all the characteristics which may be required by a user, nor does it necessarily represent the optimum performance achievable.
The present document contains the technical characteristics and test methods for Ground- and Wall- Probing Radar applications.
...