SIST EN ISO 5943:2007
(Main)Cheese and processed cheese products - Determination of chloride content - Potentiometric titration method (ISO 5943:2006)
- Abstract
The International Standard describes a method for the determination of chloride content using a potentiometric titration method.
- Status
- Published
- Publication Date
- 20-Jun-2007
- Technical Committee
- KŽP - Agricultural food products
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 14-Jun-2007
- Due Date
- 19-Aug-2007
- Completion Date
- 21-Jun-2007
SIST EN ISO 5943:2007 is the Slovenian adoption of EN ISO 5943:2006, published by SIST. It specifies a potentiometric titration method for determining chloride content in cheese and processed cheese products. The method is intended for analytical laboratories, quality control, and product verification for cheeses and processed cheese products containing more than 0.2 % chloride ion.
What does SIST EN ISO 5943:2007 specify?
SIST EN ISO 5943:2007 specifies how to measure chloride content in cheese and processed cheese products by potentiometric titration. It also sets the context for sampling, sample preparation, calculation, precision, and reporting so results can be compared consistently.
The document is organized into 11 clauses:
- Scope
- Terms and definitions
- Principle
- Reagents
- Apparatus
- Sampling
- Preparation of test sample
- Procedure
- Calculation and expression of results
- Precision
- Test report
Clause 1 limits the method to products with more than 0.2 % chloride ion. In practice, that tells the reader when the method is suitable and when another approach may be needed.
What are the key requirements of SIST EN ISO 5943:2007?
SIST EN ISO 5943:2007 is built around a wet-chemistry titration on a prepared cheese sample. The most important requirements are the sample condition, the titration sequence, the endpoint criterion, and the way the result is calculated and reported.
Sample handling and preparation
Clause 6 says the sample should reach the laboratory representative of the product and not be damaged or changed during transport or storage. Clause 7 then requires removing rind, smear, or mouldy surface layers so the test sample reflects the cheese as usually consumed.
The sample is ground, grated, or otherwise mixed thoroughly, then placed in an airtight container and analysed as soon as possible. If storage is unavoidable, the document gives a holding temperature of 10 °C to 12 °C. This matters because moisture loss, surface contamination, or poor mixing can shift the chloride result.
Reagents and apparatus
Clause 4 requires analytical-grade reagents and water of suitable purity. The method uses a silver nitrate standard solution and nitric acid, with the silver nitrate solution standardized against dried sodium chloride.
Clause 5 lists the needed equipment: grinder or grater, analytical balance, blender, potentiometer with suitable electrodes, vessel, cylinders, burette, and stirrer. In practice, this means the laboratory needs controlled weighing and a reliable electrochemical setup to detect the titration endpoint.
Titration procedure
Clause 8 weighs a 2 g to 5 g test portion, suspends it in warm water, acidifies it, and titrates with silver nitrate while stirring continuously. The endpoint is reached at the maximum potential difference between successive equal additions of titrant.
A blank test is required in parallel. That blank corrects for reagent and procedure effects, so the final chloride value reflects the sample rather than the chemicals used in the analysis.
Calculation, expression, and precision
Clause 9 calculates chloride content as a mass fraction using the blank-corrected titration result and the test portion mass. The result may be expressed as chloride ion, sodium chloride, or potassium chloride by using the appropriate molar mass, and it is reported to two decimal places.
Clause 10 gives repeatability and reproducibility data based on an interlaboratory test. Clause 11 requires the test report to identify the sample, the sampling method if known, the method used, any optional or unusual operating details, and the final result with its form of expression.
What terms does SIST EN ISO 5943:2007 define?
- Chloride content - the mass fraction of substances determined by the procedure in this standard, expressed as chloride ion, sodium chloride, or another chloride form.
- Test portion - the weighed amount of prepared sample taken for analysis in Clause 8.
- Blank test - a run with reagents but without the test portion, used to correct the measurement.
- Potentiometric titration - a titration method that follows the change in electrode potential to find the endpoint.
- Repeatability - closeness of agreement between results from the same laboratory, operator, equipment, and short time interval.
- Reproducibility - closeness of agreement between results from different laboratories and operators using different equipment.
Who uses SIST EN ISO 5943:2007?
SIST EN ISO 5943:2007 is used by dairy laboratories, cheese manufacturers, contract testing labs, and quality control teams that need a standard chloride measurement. It is also relevant to buyers and inspection bodies that check product composition or compare results across laboratories.
Typical tasks include routine quality control on cheese and processed cheese products, verification of salt-related composition, method-based testing, and reporting results in a standardized form.
What changed in SIST EN ISO 5943:2007 from the previous edition?
SIST EN ISO 5943:2007 replaces SIST EN ISO 5943:2006.
Which standards are used with SIST EN ISO 5943:2007?
- ISO 707|IDF 50 - gives guidance on sampling; Clause 6 points users to it for recommended sampling practice.
- ISO 5725:1986 - was used to calculate the precision data reported in Clause 10.
- ISO 5725-1:1994 - provides general principles and definitions for accuracy, trueness, and precision.
- ISO 5725-2:1994 - gives the basic method for determining repeatability and reproducibility of a standard measurement method.
What does the SIST EN ISO 5943:2007 document contain?
The document contains the full analytical procedure, from principle through reporting. It covers reagent preparation, required apparatus, sample preparation, the titration sequence, the blank determination, and the calculation of chloride content.
It also includes the precision statement based on an interlaboratory study, so users can judge how close repeated results should be. The final clause defines what the laboratory report has to record for traceable use of the method.
Relations
- Effective Date
- 22-Dec-2008
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

Bureau Veritas
Bureau Veritas is a world leader in laboratory testing, inspection and certification services.

DNV
DNV is an independent assurance and risk management provider.
Sponsored listings
Frequently Asked Questions
SIST EN ISO 5943:2007 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Cheese and processed cheese products - Determination of chloride content - Potentiometric titration method (ISO 5943:2006)". This standard covers: The International Standard describes a method for the determination of chloride content using a potentiometric titration method.
The International Standard describes a method for the determination of chloride content using a potentiometric titration method.
SIST EN ISO 5943:2007 is classified under the following ICS (International Classification for Standards) categories: 67.100.30 - Cheese. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN ISO 5943:2007 has the following relationships with other standards: It is inter standard links to SIST EN ISO 5943:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN ISO 5943:2007 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Terms and definitions
- 2.1 chloride content of cheese and processed cheese products
- 3 Principle
- 4 Reagents
- 5 Apparatus
- 6 Sampling
- 7 Preparation of test sample
- 8 Procedure
- 8.1 Test portion
- 8.2 Determination
- 8.3 Blank test
- 9 Calculation and expression of results
- 9.1 Calculation
- 9.2 Expression of results
- 10 Precision
- 10.1 Interlaboratory test
- 10.2 Repeatability
- 10.3 Reproducibility
- 11 Test report
- Bibliography
1 Scope
This International Standard specifies a potentiometric titration method for the determination of the chloride content of cheese and processed cheese products.
The method is applicable to all cheeses and processed cheese products containing more than 0,2 % (mass fraction) of chloride ion.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
2.1 chloride content of cheese and processed cheese products
mass fraction of substances determined by the procedure specified in this International Standard NOTE It is expressed as a mass fraction, in percent, of chloride ion or sodium chloride or any other chloride.
3 Principle
A test portion is suspended in water. The suspension is acidifed with nitric acid then the chloride ions are titrated potentiometrically with a silver nitrate standard solution.
4 Reagents
Use only reagents of recognized analytical grade, unless otherwise specified, and distilled or demineralized water or water of at least equivalent purity.
4.1 Silver nitrate standard solution, c(AgNO ) = 0,08 mol/l to 0,12 mol/l.
Dissolve 13,6 g to 20,4 g of silver nitrate in water which is practically free from carbon dioxide and dilute to 1 000 ml. Standardize the solution against sodium chloride (NaCl), which has previously been dried at 300 °C, expressing the concentration of the silver nitrate standard solution to four decimal places. Store the solution away from direct light.
4.2 Nitric acid, c(HNO ) ≈ 4 mol/l.
ISO 5943:2006(E) IDF 88:2006(E)
5 Apparatus
5.1 Device for grinding or grating cheese, capable of being cleaned easily. 5.2 Analytical balance, capable of weighing to the nearest 1 mg, with a readability of 0,1 mg. 5.3 Blender.
5.4 Potentiometer, provided with a measuring electrode suitable for the determination of chloride (e.g. a silver electrode) and a reference electrode [e.g. a mercury(l) sulfate electrode]. 5.5 Vessel, suitable for blending and titrating.
5.6 Graduated cylinders, of capacity 10 ml and 50 ml.
5.7 Burette, graduated in divisions of 0,1 ml, of capacity 50 ml, or an automatic plunger burette, readable to the nearest 0,01 ml. The burette, or automatic plunger burette, should preferably be made of brown glass. 5.8 Stirrer.
6 Sampling
A representative sample should have been sent to the laboratory. It should not have been damaged or changed during transport or storage.
Sampling is not part of the method specified in this International Standard. A recommended sampling method [1] is given in ISO 707⎪IDF 50 .
...