Abstract

This document specifies requirements and classification of air permeability of both fixed and openable parts of curtain walling, under positive and negative static air pressure.
This document applies to curtain walling as specified in EN 13830.
NOTE   This version of EN 12152:2023 will supersede EN 12152:2002. Existing test results according to EN 12152:2002 could be considered still valid compared with this version of EN 12152.

Status
Not Published
Public Enquiry End Date
19-Nov-2026
Technical Committee
ISTP - Doors and windows
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
02-Oct-2026
Due Date
19-Feb-2027

Buy Documents

Draft

SIST EN 12152:2023/oprA1:2026

English language (5 pages)
Preview
Preview
e-Library read for
×1 day

Overview

SIST EN 12152:2023/oprA1:2026 is a CEN draft amendment for curtain walling air permeability. It addresses performance requirements and classification for the air permeability of both fixed parts and openable parts of curtain wall systems under positive and negative static air pressure.

This document applies to curtain walling specified in EN 13830 and is relevant to designers, manufacturers, test laboratories, and specifiers working with modern façade systems. As a draft amendment, it is submitted for enquiry and may still change before final approval. It is intended to modify EN 12152:2023, and the existing test results from EN 12152:2002 may still be considered valid in relation to this updated version.

For projects where building envelope performance, façade airtightness, and curtain wall classification matter, this standard supports consistent evaluation and comparison.

Key Topics

The amendment focuses on improving clarity and alignment in the terminology and classification framework used for curtain walling air permeability.

Key areas include:

  • Air permeability definition

    • Clarifies how air permeability is expressed and related to overall area or fixed joint length
  • Fixed joint and openable joint

    • Refines the distinction between joints in fixed areas and joints in openable elements
  • Requirements

    • Updates the way air permeability is assessed for fixed areas under both positive and negative pressure conditions
  • Classification

    • Revises classification language to support consistent interpretation of performance categories
  • Figure references and terminology

    • Corrects figure keys and titles to improve readability and technical accuracy

These updates are important for ensuring that curtain wall performance requirements are applied consistently across testing, documentation, and product classification.

Applications

SIST EN 12152:2023/oprA1:2026 is especially useful in the following contexts:

  • Curtain wall design and specification

    • Helps define air permeability targets for façade systems
  • Product testing and evaluation

    • Supports laboratory assessment of curtain wall air leakage performance
  • Quality assurance

    • Assists manufacturers in comparing products against European performance classes
  • Compliance and procurement

    • Useful for project teams seeking standardized façade performance criteria
  • Building envelope engineering

    • Contributes to better control of airflow through curtain walling assemblies

In practice, the standard helps stakeholders evaluate how curtain wall systems behave under pressure differences, supporting more reliable façade selection and performance reporting.

Related Standards

Several standards are closely connected to SIST EN 12152:2023/oprA1:2026:

  • EN 13830 - Curtain walling standard referenced in the scope
  • EN 12207 - Relevant for openable parts and joint classification
  • EN 12152:2023 - The base standard modified by this draft amendment
  • EN 12152:2002 - Previous edition referenced in the note on continued validity of test results

For professionals working with European façade standards, air permeability classification, and curtain wall testing, SIST EN 12152:2023/oprA1:2026 is a key document to monitor during the standardization process.

Relations

Effective Date
17-Jun-2026

Buy Documents

Draft

SIST EN 12152:2023/oprA1:2026

English language (5 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

SIST EN 12152:2023/oprA1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Curtain walling - Air permeability - Performance requirements and classification". This standard covers: This document specifies requirements and classification of air permeability of both fixed and openable parts of curtain walling, under positive and negative static air pressure. This document applies to curtain walling as specified in EN 13830. NOTE This version of EN 12152:2023 will supersede EN 12152:2002. Existing test results according to EN 12152:2002 could be considered still valid compared with this version of EN 12152.

This document specifies requirements and classification of air permeability of both fixed and openable parts of curtain walling, under positive and negative static air pressure. This document applies to curtain walling as specified in EN 13830. NOTE This version of EN 12152:2023 will supersede EN 12152:2002. Existing test results according to EN 12152:2002 could be considered still valid compared with this version of EN 12152.

SIST EN 12152:2023/oprA1:2026 is classified under the following ICS (International Classification for Standards) categories: 91.060.10 - Walls. Partitions. Facades. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 12152:2023/oprA1:2026 has the following relationships with other standards: It is inter standard links to SIST EN 12152:2023. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 12152:2023/oprA1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2026
Obešene fasade - Prepustnost zraka - Zahteve in klasifikacija - Dopolnilo A1
Curtain walling - Air permeability - Performance requirements and classification
Vorhangfassaden - Luftdurchlässigkeit - Leistungsanforderungen und Klassifizierung
Façades rideaux - Perméabilité à l'air - Exigences de performance et classification
Ta slovenski standard je istoveten z: EN 12152:2023/prA1
ICS:
91.060.10 Stene. Predelne stene. Walls. Partitions. Facades
Fasade
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
EN 12152:2023
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
September 2026
ICS 91.060.10
English Version
Curtain walling - Air permeability - Performance
requirements and classification
Façades rideaux - Perméabilité à l'air - Exigences de Vorhangfassaden - Luftdurchlässigkeit -
performance et classification Leistungsanforderungen und Klassifizierung
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 33.

This draft amendment A1, if approved, will modify the European Standard EN 12152:2023. If this draft becomes an amendment,
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of
this amendment into the relevant national standard without any alteration.

This draft amendment was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12152:2023/prA1:2026 E
worldwide for CEN national Members.

Contents Page
European foreword . 3
1 Modifications to 3.4, air permeability . 4
2 Modifications to 3.5, fixed joint . 4
3 Modifications to 3.7, openable joint . 4
4 Modifications to Clause 5, Requirements . 4
5 Modification to key of Figure 1 . 4
6 Modification to Clause 7, Classif
...