Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 2: Matching of sets with headphones if either or both are offered separately, or are offered as one package equipment but with standardised connectors between the two allowing to combine components of different manufacturers or different design

This Part 2 of EN 50332 specifies methods of measuring the matching values for the use of personal music players and headphones/earphones defined for the use with those and with standardised connectors allowing to combine components of different manufacturers or different design sold separately in order to avoid possible hearing impairment by excessive sound pressure resulting from them. Compared with “one-package sets“ the sound pressure level at the ear cannot be fixed by only one condition but needs at least two characteristics, one each for player and the headphones/earphones, defined by the matching values for their connection. Requirements for protection against excessive sound pressure from personal music players are given in EN 60950-1:2006/A12:2011 and EN 60065:2002/A12:2011.

Elektroakustische Geräte: Kopfhörer und Ohrhörer in Verbindung mit tragbaren Audiogeräten - Verfahren zur Messung des maximalen Schalldruckpegels -- Teil 2: Anpassung von Geräten und Kopfhörern, wenn eine der beiden oder beide Komponenten getrennt angeboten werden

Equipement de systèmes acoustiques: Casques et écouteurs associés avec un baladeur - Méthode de mesure de niveau maximal de pression acoustique -- Part 2 : Adaptation des équipements avec des écouteurs provenant de différents fabricants, ou provenant d’un équipement complet mais avec des connecteurs normalisés entre les deux, permettant d’associer des composants provenant de différents fabricants ou bien de conception différente

Elektroakustične naprave: Naglavne in ušesne slušalke s pripadajočimi osebnimi glasbenimi predvajalniki - Metodologija za merjenje ravni največjega zvočnega tlaka - 2. del: Ujemanje elektroakustičnih naprav z naglavnimi slušalkami, če so ene ali druge ponujene ločeno ali v enem kompletu, vendar s standardiziranimi konektorji za medsebojno povezavo, ki omogočajo kombiniranje komponent različnih proizvajalcev ali različnih zasnov

General Information

Status
Published
Publication Date
03-Mar-2014
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
15-Nov-2013
Due Date
20-Jan-2014
Completion Date
04-Mar-2014

Relations

Effective Date
28-Jan-2023

SIST EN 50332-2:2014 Overview

SIST EN 50332-2:2014 is a European standard developed by the CLC (European Committee for Electrotechnical Standardization) that focuses on the safety and measurement methodology of sound system equipment, specifically headphones and earphones used with personal music players. This document is Part 2 of the series and addresses the measurement of maximum sound pressure levels when headphones and personal music players are sold separately or as a package with standardized connectors allowing the combination of components from different manufacturers or designs.

The core aim of SIST EN 50332-2:2014 is to establish a reliable methodology for measuring and defining matching values between players and headphones to prevent hearing impairment due to excessive sound pressure levels (SPL). This standard complements Part 1 of EN 50332, which covers "one-package equipment" sets.

Key Topics Covered

  • Measurement Methodology for SPL Matching
    This standard specifies methods for measuring the matching values between personal music players and headphones/earphones when combined, especially when these devices have standardized connectors.

  • Player Characteristics and Testing
    Defines how to measure the maximum output voltage of a personal music player under standardized conditions including input signals, operating conditions, and analogue/digital audio output methods.

  • Headphone/Earphone Measurement
    Specifies the use of Head and Torso Simulator (HATS) for acoustical measurements and outlines the procedure to ensure proper fit and accurate measurement of sound pressure levels to maximize safety.

  • Standardized Connectors and Combination Safety
    Addresses how headphones and players can be safely paired when sold separately yet combined through standardized connectors, ensuring that SPL does not exceed safe limits.

  • Simulated Programme Signal and Input Voltage
    Uses simulated programme signal characteristic voltage, a standardized input voltage, to replicate real-world listening conditions during tests.

  • Reference to Hearing Protection Standards
    SIST EN 50332-2:2014 is harmonized with other safety standards such as EN 60950-1 and EN 60065, ensuring comprehensive protection against excessive sound pressure from audio devices.

Applications

  • Manufacturers of Personal Music Players and Headphones
    Applying EN 50332-2 helps in designing, testing, and certifying headphones and players to ensure user safety when these products are combined.

  • Quality Control and Compliance Testing
    Enables manufacturers and testing laboratories to verify that paired devices conform to safety limits on sound pressure, preventing potential hearing damage.

  • Product Development for Interoperable Audio Equipment
    Supports creation of modular audio systems with interchangeable components from different brands or designs while maintaining acoustic safety.

  • Consumer Safety and Regulatory Compliance
    Helps retailers and importers ensure that personal audio equipment meets European regulatory requirements for auditory health protection.

Related Standards

  • EN 50332-1:2013 – Defines maximum sound pressure level measurement methodology for "one-package" headphone and personal music player equipment.

  • EN 60268-7:2011 – Details headphone and earphone specifications relevant to electroacoustics.

  • EN 60950-1:2006/A12:2011 and EN 60065:2002/A12:2011 – Provide general requirements for protection against excessive sound pressure from audio devices.

  • EN 61672-1 – Defines specifications for sound level meters used during acoustic measurements.

  • EN 61260 – Relates to octave-band and fractional-octave-band filters critical for analyzing sound signals.

Practical Value

Implementing SIST EN 50332-2:2014 enables the safe integration of audio components, ensuring personal music players and headphones deliver sound within safe pressure levels. This standard is essential for manufacturers and testing facilities to prevent hearing damage risks when customers mix and match headphones and players from different sources. It supports the evolving trend toward modular consumer audio equipment while maintaining consistent hearing protection standards. By adhering to this standard, companies not only comply with European safety laws but also promote responsible product design prioritizing user auditory health.

Frequently Asked Questions

SIST EN 50332-2:2014 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 2: Matching of sets with headphones if either or both are offered separately, or are offered as one package equipment but with standardised connectors between the two allowing to combine components of different manufacturers or different design". This standard covers: This Part 2 of EN 50332 specifies methods of measuring the matching values for the use of personal music players and headphones/earphones defined for the use with those and with standardised connectors allowing to combine components of different manufacturers or different design sold separately in order to avoid possible hearing impairment by excessive sound pressure resulting from them. Compared with “one-package sets“ the sound pressure level at the ear cannot be fixed by only one condition but needs at least two characteristics, one each for player and the headphones/earphones, defined by the matching values for their connection. Requirements for protection against excessive sound pressure from personal music players are given in EN 60950-1:2006/A12:2011 and EN 60065:2002/A12:2011.

This Part 2 of EN 50332 specifies methods of measuring the matching values for the use of personal music players and headphones/earphones defined for the use with those and with standardised connectors allowing to combine components of different manufacturers or different design sold separately in order to avoid possible hearing impairment by excessive sound pressure resulting from them. Compared with “one-package sets“ the sound pressure level at the ear cannot be fixed by only one condition but needs at least two characteristics, one each for player and the headphones/earphones, defined by the matching values for their connection. Requirements for protection against excessive sound pressure from personal music players are given in EN 60950-1:2006/A12:2011 and EN 60065:2002/A12:2011.

SIST EN 50332-2:2014 is classified under the following ICS (International Classification for Standards) categories: 17.140.50 - Electroacoustics; 33.160.50 - Accessories. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 50332-2:2014 has the following relationships with other standards: It is inter standard links to SIST EN 50332-2:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase SIST EN 50332-2:2014 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2014
1DGRPHãþD
SIST EN 50332-2:2004
(OHNWURDNXVWLþQHQDSUDYH1DJODYQHLQXãHVQHVOXãDONHVSULSDGDMRþLPLRVHEQLPL
JODVEHQLPLSUHGYDMDOQLNL0HWRGRORJLMD]DPHUMHQMHUDYQLQDMYHþMHJD]YRþQHJD
WODNDGHO8MHPDQMHHOHNWURDNXVWLþQLKQDSUDY]QDJODYQLPLVOXãDONDPLþHVR
HQHDOLGUXJHSRQXMHQHORþHQRDOLYHQHPNRPSOHWXYHQGDUVVWDQGDUGL]LUDQLPL
NRQHNWRUML]DPHGVHERMQRSRYH]DYRNLRPRJRþDMRNRPELQLUDQMHNRPSRQHQW
UD]OLþQLKSURL]YDMDOFHYDOLUD]OLþQLK]DVQRY
Sound system equipment: Headphones and earphones associated with personal music
players - Maximum sound pressure level measurement methodology - Part 2: Matching
of sets with headphones if either or both are offered separately, or are offered as one
package equipment but with standardised connectors between the two allowing to
combine components of different manufacturers or different design
Elektroakustische Geräte: Kopfhörer und Ohrhörer in Verbindung mit tragbaren
Audiogeräten - Verfahren zur Messung des maximalen Schalldruckpegels -- Teil 2:
Anpassung von Geräten und Kopfhörern, wenn eine der beiden oder beide
Komponenten getrennt angeboten werden
Ta slovenski standard je istoveten z: EN 50332-2:2013
ICS:
17.140.50 Elektroakustika Electroacoustics
33.160.50 Pribor Accessories
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 50332-2
NORME EUROPÉENNE
October 2013
EUROPÄISCHE NORM
ICS 17.140.50; 33.160.50 Supersedes EN 50332-2:2003
English version
Sound system equipment: Headphones and earphones associated with
personal music players -
Maximum sound pressure level measurement methodology -
Part 2: Matching of sets with headphones if either or both are offered
separately, or are offered as one package equipment but with standardised
connectors between the two allowing to combine components of different
manufacturers or different design

Equipement de systèmes acoustiques: Elektroakustische Geräte: Kopfhörer und
Casques et écouteurs associés avec un Ohrhörer in Verbindung mit tragbaren
baladeur - Audiogeräten -
Méthode de mesure de niveau maximal de Verfahren zur Messung des maximalen
pression acoustique - Schalldruckpegels -
Part 2 : Adaptation des équipements avec des Teil 2: Anpassung von Geräten und
écouteurs provenant de différents fabricants, Kopfhörern, wenn eine der beiden oder beide
ou provenant d’un équipement complet mais Komponenten getrennt angeboten werden
avec des connecteurs normalisés entre les
deux, permettant d’associer des composants
provenant de différents fabricants ou bien de
conception différente
This European Standard was approved by CENELEC on 2013-09-23. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50332-2:2013 E
Contents Page
Foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Basic conditions for specifications and measurements . 5
5 Player characteristics and methods of measurement . 5
5.1 Maximum output voltage V . 5
m
5.2 Method of measurement and conditions . 5
5.2.1 Input signal . 5
5.2.2 Operating conditions . 5
5.2.3 Method of measurement for analogue audio outputs . 5
5.2.4 Method of measurement for digital audio outputs . 5
6 Headphone/Earphone characteristics and methods of measurement . 6
6.1 Measuring equipment . 6
6.2 Simulated programme signal characteristic voltage . 6
6.3 Method of measurement arrangement and conditions . 6
6.3.1 Input signal . 6
6.3.2 Source impedance of analogue input devices . 6
6.3.3 Acoustical measurement method . 6
6.3.4 Headphones/earphones fit . 6
6.3.5 Measurement and evaluation . 6
Annex A (informative) Example test procedure for acoustic safety of listening devices . 7
A.1 Acoustic coupling between listening device’s receiver and the ear simulator on HATS
(head and torso simulator) . 7
A.1.1 General. 7
A.1.2 Circum-aural, Supra-aural and Supra-concha listening devices . 7
A.1.3 Intra-concha listening devices . 7
A.1.4 Insert type listening devices . 7
A.2 Measurement and Analysis (General) . 7
A.3 Corded analogue listening device . 8
A.4 Corded digital listening device . 8
A.5 Cordless digital listening device . 8
A.6 Listening device with multiple operating modes . 8
Bibliography . 9

- 3 - EN 50332-2:2013
Foreword
This document (EN 50332-2:2013) has been prepared by CLC/TC 108X, "Safety of electronic
equipment within the fields of Audio/Video, Information Technology and Communication Technology".
The following dates are fixed:
• latest date by which this document has to be
(dop) 2014-09-23
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards
(dow) 2016-09-23
conflicting with this document have to
be withdrawn
This document supersedes EN 50332-2:2003.
EN 50332-2:2003:
- deletion of limits;
- addition of digital signals;
- adaptations to use the term "personal music players".
EN 50332, Sound system equipment: Headphones and earphones associated with personal music
players  Maximum sound pressure level measurement methodology, is composed with the following
parts:
− Part 1: General method for "one package equipment";
− Part 2: Matching of sets with headphones if either or both are offered separately, or are offered as
one package equipment but with standardised connectors between the two allowing to combine
components of different manufacturers or different design.
The Part 1 of this standard describes conditions and procedures for combination of player units and
headphones sold as “one-package sets”. The sound pressure limitation (SPL) of these sets is lost
when players or headphones with standardised sockets and plugs are arbitrarily combined.
This Part 2 provides measurement methods for the matching values which guarantee the SPL limit
also for the aforementioned condition.
__________
1 Scope
This Part 2 of EN 50332 specifies methods of measuring the matching values for the use of personal
music players and headphones/earphones defined for the use with those and with standardised
connectors or interfaces allowing to combine components of different manufacturers or different
design sold separately in order to avoid possible hearing impairment by excessive sound pressure
resulting from them.
Compared with “one-package sets“ the sound pressure level at the ear cannot be fixed by only one
condition but needs at least two characteristics, one each for player and the headphones/earphones,
defined by the matching values for their connection.
Requirements for protection against excessive sound pressure from personal music players are given
in EN 60950-1:2006/A12:2011 and EN 60065:2002/A12:2011.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition ci
...

Questions, Comments and Discussion