Acoustics — Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels

ISO 6926:2016 specifies the acoustical performance requirements for reference sound sources: - temporal steadiness (stability) of the sound power output; - spectral characteristics; - directivity. Temporal steadiness is defined in terms of the standard deviation of repeatability (see 5.2). The spectral characteristics can be verified in either a hemi-anechoic room or a reverberation test room from measurements of the frequency band sound power levels in accordance with this International Standard (see 5.4). The performance requirements on directivity index can only be verified in a hemi-anechoic room (see 5.5.) ISO 6926:2016 also specifies procedures for providing level calibration data and uncertainty on a sound source intended for use as a reference sound source in terms of its sound power level under reference meteorological conditions as defined in Clause 4 in octave and in one-third-octave bands, and with frequency weighting A. ISO 6926:2016 is titled as a calibration standard even though the method is conducted in a testing laboratory and the level calibration results are not directly traceable to national standards of measure in a strict metrological sense. Testing laboratories performing this method are not expected to meet all requirements normally associated with a calibration laboratory. NOTE ISO/IEC 17025[15] specifies different requirements for the competence of testing laboratories and calibration laboratories respectively. Laboratories testing reference sound sources in accordance with this International Standard would typically comply with the requirements for testing laboratories but not necessarily with those for calibration laboratories. ISO 6926:2016 specifies methods to calibrate reference sound sources not only in a free field over a reflecting plane but also in reverberation test rooms at different distances from the boundary surfaces. For the position of the reference sound source on one reflecting plane, the two different test environments mentioned above are considered equivalent for frequency bands above or equal to 200 Hz. At 160 Hz and below, some systematic differences can occur (see 11.2). For frequencies below 100 Hz, an alternative calibration method using sound intensity is given. The sound source can either be placed directly on the floor or mounted on a stand to be used at a certain elevation above the floor. According to this International Standard, stand-mounted sources are calibrated in reverberation test rooms. Floor-mounted sources are either calibrated in hemi-anechoic or in reverberation test rooms. For floor-mounted sources in hemi-anechoic rooms, this International Standard is valid only for sources whose maximum vertical dimension is less than 0,5 m and whose maximum horizontal dimension is less than 0,8 m. According to this International Standard, only floor-mounted reference sound sources can be used when carrying out measurements on a measurement surface. For reference sound sources to be used or calibrated under reverberant conditions, no such restrictions on maximum dimensions apply.

Acoustique — Prescriptions relatives aux performances et à l'étalonnage des sources sonores de référence pour la détermination des niveaux de puissance acoustique

ISO 6926:2016 spécifie les exigences relatives aux performances acoustiques des sources sonores de référence: - stabilité dans le temps de la puissance acoustique émise; - caractéristiques spectrales; - directivité. La stabilité dans le temps est définie en termes d'écart-type de répétabilité (voir 5.2). Les caractéristiques spectrales peuvent être vérifiées soit dans une salle semi-anéchoïque, soit dans une salle d'essai réverbérante, à partir du mesurage des niveaux de puissance acoustique par bande de fréquences conformément à la présente Norme internationale (voir 5.4). Les exigences de performance relatives à l'indice de directivité ne peuvent être vérifiées que dans une salle semi-anéchoïque (voir 5.5). ISO 6926:2016 définit également des modes opératoires pour obtenir les données et l'incertitude de l'étalonnage des niveaux d'une source sonore destinée à être utilisée comme source sonore de référence, le résultat étant exprimé par un niveau de puissance acoustique par bandes d'octave et de tiers d'octave, et avec la pondération fréquentielle A, dans les conditions météorologiques de référence telles que définies à l'Article 4. ISO 6926:2016 est appelée norme d'étalonnage bien que la méthode soit applicable dans un laboratoire d'essai et que les résultats de l'étalonnage des niveaux ne se rapportent pas directement à des normes nationales de mesure dans un sens métrologique strict. Il n'est pas attendu que les laboratoires d'essai appliquant cette méthode satisfassent à toutes les exigences normalement associées à un laboratoire d'étalonnage. NOTE L'ISO/IEC 17025[15] spécifie différentes exigences pour les compétences respectives des laboratoires d'essai et des laboratoires d'étalonnage. Les laboratoires qui soumettent à l'essai des sources sonores de référence conformément à la présente Norme internationale doivent normalement se conformer aux exigences des laboratoires d'essai, mais pas nécessairement à celles des laboratoires d'étalonnage. ISO 6926:2016 spécifie des méthodes d'étalonnage pour les sources sonores de référence non seulement en champ libre au-dessus d'un plan réfléchissant, mais aussi dans des salles d'essais réverbérantes à diverses distances des surfaces délimitantes. Pour la position de la source sonore de référence au-dessus d'un plan réfléchissant unique, les deux environnements d'essai différents mentionnés ci-dessus sont considérés comme équivalents pour les bandes de fréquences supérieures ou égales à 200 Hz. À 160 Hz et au-dessous, des écarts systématiques peuvent exister (voir 11.2). Pour les fréquences inférieures à 100 Hz, une autre méthode d'étalonnage utilisant l'intensité acoustique est donnée. La source sonore peut être conçue spécifiquement soit pour être posée directement sur le sol, soit pour être montée sur un support afin d'être utilisée à une certaine distance du sol. Conformément à la présente Norme internationale, les sources montées sur un support sont étalonnées dans des salles d'essai réverbérantes. Les sources au sol sont étalonnées dans des salles d'essai semi-anéchoïques ou réverbérantes. Pour des sources au sol en salles semi-anéchoïques, la présente Norme internationale s'applique uniquement aux sources dont la dimension verticale maximale est inférieure à 0,5 m et dont la dimension horizontale maximale est inférieure à 0,8 m. Conformément à la présente Norme internationale, seules les sources sonores de référence posées au sol peuvent être utilisées pour effectuer des mesurages sur une surface. Les restrictions applicables aux dimensions maximales ci‑dessus ne s'appliquent pas aux sources sonores de référence destinées à être utilisées ou étalonnées dans des conditions de champ réverbéré.

General Information

Status
Published
Publication Date
11-Jan-2016
Technical Committee
ISO/TC 43/SC 1 - Noise
Current Stage
9093 - International Standard confirmed
Start Date
08-Jul-2021
Completion Date
14-Feb-2026

Relations

Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
12-Feb-2026
Effective Date
06-Jun-2022
Effective Date
24-Jul-2021
Effective Date
28-Feb-2009

Overview

ISO 6926:2016 - Acoustics - Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels - defines performance criteria and calibration procedures for reference sound sources (RSS) used in sound power determinations. It specifies how to verify temporal stability, spectral characteristics and directivity of RSS and how to provide level calibration data (including uncertainty) in octave and one‑third‑octave bands and with A‑weighting, all under defined reference meteorological conditions.

Key topics and technical requirements

  • Performance requirements
    • Temporal steadiness (stability): Expressed as the standard deviation of repeatability (see Clause 5.2).
    • Spectral characteristics: Verified by measuring frequency‑band sound power levels in either a hemi‑anechoic room or a reverberation test room (Clause 5.4).
    • Directivity: Directivity index requirements can only be verified in a hemi‑anechoic room (Clause 5.5).
  • Calibration environments
    • Methods cover both free field over a reflecting plane (hemi‑anechoic) and reverberation test rooms. Equivalence of environments applies for bands ≥ 200 Hz; systematic differences can occur at 160 Hz and below (see Clause 11.2).
    • For frequencies below 100 Hz, an alternative calibration method using sound intensity is provided (Annex B).
  • Mounting and dimensional limits
    • Stand‑mounted sources: calibrated in reverberation test rooms.
    • Floor‑mounted sources: may be calibrated in hemi‑anechoic or reverberation rooms; hemi‑anechoic validity restricted to sources with vertical dimension < 0.5 m and horizontal < 0.8 m.
  • Reporting and uncertainty
    • Calibration results are reported as sound power levels under reference meteorological conditions (Clause 4), with associated measurement uncertainty (updated alignment with GUM/ISO/IEC Guide 98‑3).
  • Practical note on calibration status
    • ISO 6926:2016 is titled a calibration standard but is intended for testing laboratories; results are not necessarily strictly traceable to national metrology institutes. Laboratories commonly comply with testing‑lab competence (ISO/IEC 17025 distinctions noted).

Applications - who uses ISO 6926:2016

  • Acoustic testing laboratories calibrating reference sound sources for comparison methods.
  • Manufacturers of RSS and acoustic test equipment.
  • Noise emission test facilities using ISO 3740‑series methods to determine sound power levels (e.g., ISO 3741, 3743, 3744, 3745, 3746, 3747).
  • Consultants and engineers performing environmental and machinery noise assessments who rely on calibrated RSS to relate sound pressure measurements to sound power.

Related standards

  • ISO 3740 series (ISO 3741, ISO 3745, ISO 3743, ISO 3744, ISO 3746, ISO 3747)
  • ISO/IEC Guide 98‑3 (GUM) - measurement uncertainty
  • ISO/IEC 17025 - laboratory competence (testing vs calibration)
  • IEC 61183, ISO 9614‑3 - related electroacoustic and sound intensity methods

Keywords: ISO 6926:2016, reference sound source calibration, acoustics, sound power level, hemi‑anechoic room, reverberation test room, sound intensity, measurement uncertainty.

Buy Documents

Standard

ISO 6926:2016 - Acoustics -- Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 6926:2016 - Acoustique -- Prescriptions relatives aux performances et à l'étalonnage des sources sonores de référence pour la détermination des niveaux de puissance acoustique

French language (22 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

BSMI (Bureau of Standards, Metrology and Inspection)

Taiwan's standards and inspection authority.

TAF Taiwan Verified

Sponsored listings

Frequently Asked Questions

ISO 6926:2016 is a standard published by the International Organization for Standardization (ISO). Its full title is "Acoustics — Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels". This standard covers: ISO 6926:2016 specifies the acoustical performance requirements for reference sound sources: - temporal steadiness (stability) of the sound power output; - spectral characteristics; - directivity. Temporal steadiness is defined in terms of the standard deviation of repeatability (see 5.2). The spectral characteristics can be verified in either a hemi-anechoic room or a reverberation test room from measurements of the frequency band sound power levels in accordance with this International Standard (see 5.4). The performance requirements on directivity index can only be verified in a hemi-anechoic room (see 5.5.) ISO 6926:2016 also specifies procedures for providing level calibration data and uncertainty on a sound source intended for use as a reference sound source in terms of its sound power level under reference meteorological conditions as defined in Clause 4 in octave and in one-third-octave bands, and with frequency weighting A. ISO 6926:2016 is titled as a calibration standard even though the method is conducted in a testing laboratory and the level calibration results are not directly traceable to national standards of measure in a strict metrological sense. Testing laboratories performing this method are not expected to meet all requirements normally associated with a calibration laboratory. NOTE ISO/IEC 17025[15] specifies different requirements for the competence of testing laboratories and calibration laboratories respectively. Laboratories testing reference sound sources in accordance with this International Standard would typically comply with the requirements for testing laboratories but not necessarily with those for calibration laboratories. ISO 6926:2016 specifies methods to calibrate reference sound sources not only in a free field over a reflecting plane but also in reverberation test rooms at different distances from the boundary surfaces. For the position of the reference sound source on one reflecting plane, the two different test environments mentioned above are considered equivalent for frequency bands above or equal to 200 Hz. At 160 Hz and below, some systematic differences can occur (see 11.2). For frequencies below 100 Hz, an alternative calibration method using sound intensity is given. The sound source can either be placed directly on the floor or mounted on a stand to be used at a certain elevation above the floor. According to this International Standard, stand-mounted sources are calibrated in reverberation test rooms. Floor-mounted sources are either calibrated in hemi-anechoic or in reverberation test rooms. For floor-mounted sources in hemi-anechoic rooms, this International Standard is valid only for sources whose maximum vertical dimension is less than 0,5 m and whose maximum horizontal dimension is less than 0,8 m. According to this International Standard, only floor-mounted reference sound sources can be used when carrying out measurements on a measurement surface. For reference sound sources to be used or calibrated under reverberant conditions, no such restrictions on maximum dimensions apply.

ISO 6926:2016 specifies the acoustical performance requirements for reference sound sources: - temporal steadiness (stability) of the sound power output; - spectral characteristics; - directivity. Temporal steadiness is defined in terms of the standard deviation of repeatability (see 5.2). The spectral characteristics can be verified in either a hemi-anechoic room or a reverberation test room from measurements of the frequency band sound power levels in accordance with this International Standard (see 5.4). The performance requirements on directivity index can only be verified in a hemi-anechoic room (see 5.5.) ISO 6926:2016 also specifies procedures for providing level calibration data and uncertainty on a sound source intended for use as a reference sound source in terms of its sound power level under reference meteorological conditions as defined in Clause 4 in octave and in one-third-octave bands, and with frequency weighting A. ISO 6926:2016 is titled as a calibration standard even though the method is conducted in a testing laboratory and the level calibration results are not directly traceable to national standards of measure in a strict metrological sense. Testing laboratories performing this method are not expected to meet all requirements normally associated with a calibration laboratory. NOTE ISO/IEC 17025[15] specifies different requirements for the competence of testing laboratories and calibration laboratories respectively. Laboratories testing reference sound sources in accordance with this International Standard would typically comply with the requirements for testing laboratories but not necessarily with those for calibration laboratories. ISO 6926:2016 specifies methods to calibrate reference sound sources not only in a free field over a reflecting plane but also in reverberation test rooms at different distances from the boundary surfaces. For the position of the reference sound source on one reflecting plane, the two different test environments mentioned above are considered equivalent for frequency bands above or equal to 200 Hz. At 160 Hz and below, some systematic differences can occur (see 11.2). For frequencies below 100 Hz, an alternative calibration method using sound intensity is given. The sound source can either be placed directly on the floor or mounted on a stand to be used at a certain elevation above the floor. According to this International Standard, stand-mounted sources are calibrated in reverberation test rooms. Floor-mounted sources are either calibrated in hemi-anechoic or in reverberation test rooms. For floor-mounted sources in hemi-anechoic rooms, this International Standard is valid only for sources whose maximum vertical dimension is less than 0,5 m and whose maximum horizontal dimension is less than 0,8 m. According to this International Standard, only floor-mounted reference sound sources can be used when carrying out measurements on a measurement surface. For reference sound sources to be used or calibrated under reverberant conditions, no such restrictions on maximum dimensions apply.

ISO 6926:2016 is classified under the following ICS (International Classification for Standards) categories: 17.140.01 - Acoustic measurements and noise abatement in general. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 6926:2016 has the following relationships with other standards: It is inter standard links to EN ISO 26101-2:2024, EN ISO 7779:2018, EN ISO 3743-2:2019, EN ISO 6926:2016, ISO 9015-1:2001, ISO 6926:2016/Amd 1:2020, ISO 6926:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO 6926:2016 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 6926
Third edition
2016-01-15
Acoustics — Requirements for the
performance and calibration of
reference sound sources used for the
determination of sound power levels
Acoustique — Prescriptions relatives aux performances et à
l’étalonnage des sources sonores de référence pour la détermination
des niveaux de puissance acoustique
Reference number
©
ISO 2016
© ISO 2016, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – All rights reserved

Contents Page
Foreword .v
Introduction .vi
1 Scope . 1
2 Normative references . 2
3 Terms and definitions . 2
4 Reference meteorological conditions . 4
5 Performance requirements . 5
5.1 General . 5
5.2 Temporal steadiness (stability) of sound power output . . 5
5.3 Total broadband sound power level . 5
5.4 Spectral characteristics. 5
5.5 Directivity . 6
5.6 Recalibration . 6
6 Instrumentation . 7
6.1 General . 7
6.2 Microphone in a hemi-anechoic room . 7
6.3 Microphone in a reverberation test room . 7
6.4 Microphone frequency response correction . 7
6.5 Verification . 8
6.6 Microphone calibration check . 8
7 Installation and operation of the reference sound source during calibration .8
7.1 General . 8
7.2 Requirements in hemi-anechoic rooms . 9
7.3 Requirements in reverberation rooms . 9
8 Calibration procedure in hemi-anechoic rooms . 9
8.1 Test environment . 9
8.2 Microphone positions . 9
8.2.1 General. 9
8.2.2 Meridional paths . 9
8.2.3 Spiral path. 9
8.2.4 Fixed point array . 9
8.2.5 Coaxial circular paths . 9
8.3 Measurements .10
8.3.1 General.10
8.3.2 Directivity index .10
8.3.3 Temporal steadiness .10
8.4 Calculations .11
9 Calibration procedure in reverberation test rooms .12
9.1 Test environment .12
9.2 Microphone positions .12
9.3 Measurements .12
9.3.1 General.12
9.3.2 Temporal steadiness .13
9.4 Calculations .13
10 Alternative calibration procedure at low frequencies .13
11 Measurement uncertainty .13
11.1 General .13
11.2 Typical values of the reproducibility standard deviation .14
12 Information to be recorded .15
13 Information to be reported .15
Annex A (informative) Guidance on the determination of C .16
Annex B (normative) Alternative calibration procedure at low frequencies .18
Bibliography .19
iv © ISO 2016 – All rights reserved

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical
Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information
The committee responsible for this document is ISO/TC 43, Acoustics, Subcommittee SC 1, Noise.
This third edition cancels and replaces the second edition (ISO 6926:1999), which has been technically
revised with the following changes:
— the clause on measurement uncertainty has been updated with stricter reference to
ISO/IEC Guide 98-3 and moved backwards in the standard to be more in line with ISO 3745;
— the corrections for meteorological conditions have been brought in line with ISO 3745 and a new
Annex A on the acoustic radiation impedance correction has been introduced;
— an alternative method using sound intensity for low frequency calibration in hemi-anechoic rooms
not fully qualified for low frequencies has been introduced in a new Annex B.
Introduction
Reference sound sources are used extensively in “comparison methods” for determining the noise
emissions of physically stationary sound sources. A reference sound source, of known sound power
output, is used to establish the numerical relationship between the sound power level of a source, in a
given location in a given acoustic environment and the space- and time-averaged sound pressure level
at a set of microphone positions. Once that relationship is established, it is straightforward to measure
the average sound pressure level produced by an “unknown source” and to determine the sound power
level produced by that source.
This International Standard defines the important physical and performance characteristics of
reference sound sources and specifies procedures for their calibration, primarily to determine the
sound power level of other sound sources.
This International Standard supplements a group or family of International Standards, the ISO 3740
group, which describes various methods for determining the sound power levels of machines
and equipment. This group of International Standards specifies the acoustical requirements for
measurements that are appropriate for different test environments.
Five International Standards in the ISO 3740 group include procedures in which a reference sound
source is used: ISO 3741, ISO 3743-1, ISO 3744, ISO 3746 and ISO 3747. ISO 3740 gives guidelines for the
use of all the International Standards in the group.
Note that the sound power output of reference sound sources will vary, in particular at low frequencies,
with the distance from the source to nearby reflecting planes. Sound power data of reference sound
sources are thus valid only for the position used during the calibration.
In addition to being useful for determining sound power levels by the comparison method, reference
sound sources can be used for qualification tests on an acoustic environment and to estimate the
influence of an acoustic environment on the sound pressure levels produced by one or more sound
sources located in that environment. Examples of International Standards referring to reference sound
sources with these applications are ISO/TR 11690-3 and ISO 14257. Requirements other than those of
this International Standard can be applicable in these cases.
vi © ISO 2016 – All rights reserved

INTERNATIONAL STANDARD ISO 6926:2016(E)
Acoustics — Requirements for the performance and
calibration of reference sound sources used for the
determination of sound power levels
1 Scope
This International Standard specifies the acoustical performance requirements for reference sound
sources:
— temporal steadiness (stability) of the sound power output;
— spectral characteristics;
— directivity.
Temporal steadiness is defined in terms of the standard deviation of repeatability (see 5.2). The
spectral characteristics can be verified in either a hemi-anechoic room or a reverberation test room
from measurements of the frequency band sound power levels in accordance with this International
Standard (see 5.4). The performance requirements on directivity index can only be verified in a hemi-
anechoic room (see 5.5.)
This International Standard also specifies procedures for providing level calibration data and
uncertainty on a sound source intended for use as a reference sound source in terms of its sound power
level under reference meteorological conditions as defined in Clause 4 in octave and in one-third-octave
bands, and with frequency weighting A.
This International Standard is titled as a calibration standard even though the method is conducted in
a testing laboratory and the level calibration results are not directly traceable to national standards of
measure in a strict metrological sense. Testing laboratories performing this method are not expected
to meet all requirements normally associated with a calibration laboratory.
[15]
NOTE ISO/IEC 17025 specifies different requirements for the competence of testing laboratories and
calibration laboratories respectively. Laboratories testing reference sound sources in accordance with this
International Standard would typically comply with the requirements for testing laboratories but not necessarily
with those for calibration laboratories.
This International Standard specifies methods to calibrate reference sound sources not only in a
free field over a reflecting plane but also in reverberation test rooms at different distances from the
boundary surfaces. For the position of the reference sound source on one reflecting plane, the two
different test environments mentioned above are considered equivalent for frequency bands above or
equal to 200 Hz. At 160 Hz and below, some systematic differences can occur (see 11.2). For frequencies
below 100 Hz, an alternative calibration method using sound intensity is given.
The sound source can either be placed directly on the floor or mounted on a stand to be used at a
certain elevation above the floor. According to this International Standard, stand-mounted sources are
calibrated in reverberation test rooms. Floor-mounted sources are either calibrated in hemi-anechoic
or in reverberation test rooms. For floor-mounted sources in hemi-anechoic rooms, this International
Standard is valid only for sources whose maximum vertical dimension is less than 0,5 m and whose
maximum horizontal dimension is less than 0,8 m. According to this International Standard, only floor-
mounted reference sound sources can be used when carrying out measurements on a measurement
surface. For reference sound sources to be used or calibrated under reverberant conditions, no such
restrictions on maximum dimensions apply.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 3741:2010, Acoustics — Determination of sound power levels and sound energy levels of noise sources
using sound pressure — Precision methods for reverberation test rooms
ISO 3744:2010, Acoustics — Determination of sound power levels and sound energy levels of noise sources
using sound pressure — Engineering methods for an essentially free field over a reflecting plane
ISO 3745:2012, Acoustics — Determination of sound power levels and sound energy levels of noise sources
using sound pressure — Precision methods for anechoic rooms and hemi-anechoic rooms
ISO 9613-1:1993, Acoustics — Attenuation of sound during propagation outdoors — Part 1: Calculation of
the absorption of sound by the atmosphere
ISO 9614-3, Acoustics — Determination of sound power levels of noise sources using sound intensity —
Part 3: Precision method for measurement by scanning
IEC 60942:2003, Electroacoustics — Sound calibrators
IEC 61094-1, Measurement microphones — Part 1: Specifications for laboratory standard microphones
IEC 61094-4, Measurement microphones — Part 4: Specifications for working standard microphones
IEC 61183, Electroacoustics — Random-incidence and diffuse-field calibration of sound level meters
IEC 61260-1, Electroacoustics — Octave-band and fractional-octave-band filters — Part 1: Specifications
IEC 61672-1, Electroacoustics — Sound level meters — Part 1: Specifications
IEC 61672-3:2013, Electroacoustics — Sound level meters — Part 3: Periodic tests
IEC 62585, Electroacoustics — Methods to determine corrections to obtain the free-field response of a
sound level meter
ISO/IEC Guide 98-3, Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in
measurement (GUM:1995)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
reference sound source
RSS
portable, generally electroacoustical or aerodynamic sound source or other noise-generating device,
and associated control circuitry giving a broadband stable output complying with the requirements of
this International Standard
3.2
free sound field over a reflecting plane
sound field in a homogeneous, isotropic medium in the half-space above an infinite, reflecting plane in
the absence of other reflecting obstacles
3.3
hemi-anechoic room
test room in which a free sound field over a reflecting plane is obtained
2 © ISO 2016 – All rights reserved

3.4
reverberation test room
test room meeting the requirements of ISO 3741
3.5
measurement surface
hypothetical surface of area, S, on which the microphone positions are located at which the sound
pressure levels are measured, enveloping the source under test and, in the case of a hemi-anechoic
room, terminating on the reflecting plane on which the source is located
Note 1 to entry: The measurement surface area is expressed in metres squared.
3.6
surface sound pressure level
L
p
energy-average of the time-averaged sound pressure levels at all the microphone positions, or traverses,
on the measurement surface, with the background noise corrections, K , applied at each microphone
position or traverse
Note 1 to entry: Surface sound pressure level is expressed in decibels.
Note 2 to entry: For definition and calculation of K , see ISO 3745.
3.7
sound power level
L
W
ten times the logarithm to the base 10 of the ratio of the sound power of a source, P, to a reference value,
P , expressed in decibels
P
L =10lg dB
W
P
where the reference value, P , is 1 pW
Note 1 to entry: If a specific frequency weighting as specified in IEC 61672–1, and/or specific frequency bands are
applied, this should be indicated by appropriate subscripts; e.g. L denotes the A-weighted sound power level.
WA
[17]
Note 2 to entry: This definition is technically in accordance with ISO 80000-8:2007, 8-23.
[SOURCE: ISO/TR 25417:2007, 2.9]
3.8
measurement radius
r
radius of a hemi-spherical measurement surface
3.9
directivity index
D
Ii
measure of the extent to which a source radiates sound in a particular direction, relative to the mean
sound radiation over the measurement surface, where for fixed microphones, the direction is from
the source to the position of the microphone, and for traverses, the direction is from the source to the
position along the microphone path at which the highest sound pressure level is recorded
Note 1 to entry: The directivity index of direction, i, is calculated from measurements in a hemi-anechoic room
by the following formula:
DL=−L
Ii pi p
where
L is the sound pressure level for each one-third-octave band at the ith
pi
microphone position on the measurement surface, in decibels;
L is the maximum sound pressure level for each one-third-octave
pi
band that is recorded during the ith microphone traverse (see 8.2) on the measurement sur-
face, in decibels;
is the surface sound pressure level averaged over the same measurement surface, in decibels.
L
p
Note 2 to entry: With the above ”operational“ definition, the directivity index is a measure of the uniformity of
sound radiation from the source over the particular measurement surface being employed and as it is installed in
the test environment. Definitions for the “theoretical” directivity index appearing in textbooks and the literature
usually represent the uniformity of sound radiation by comparing the source under test in its test environment to
a point source of the same sound power radiating into a full sphere in a totally free field. When such definitions are
applied to sources located in a free field above a reflecting plane, they include a constant “+3 dB” to account for the
hemispherical radiation. Care should be taken when comparing or using different definitions of directivity index.
3.10
frequency range of interest
frequency range of one-third-octave bands with nominal mid-band frequencies from 100 Hz to 10 000 Hz
Note 1 to entry: The frequency range of interest in one-third-octave bands may be extended up to as much as
20 000 Hz or down to as low as 50 Hz, provided the requirements of this International Standard are still met.
3.11
comparison method
method in which the sound power level is calculated by comparing the measured sound pressure levels
produced by the source under test in an environment with the sound pressure levels produced by a
reference sound source of known sound power output in the same environment
3.12
direct method
method in reverberation test rooms where the sound power level is calculated using the equivalent
sound absorption area determined from measurements of the reverberation time
3.13
reverberation time
T
time that is required for the sound pressure level to decrease by 60 dB after the sound source has stopped
Note 1 to entry: If the reverberation time is evaluated from the decay of the first 10 dB or 15 dB, it is denoted T
or T , respectively.
Note 2 to entry: It is expressed in seconds.
3.14
repeatability condition
condition where independent test results are obtained with the same method on identical test items in
the same laboratory by the same operator using the same equipment within short intervals of time
4 Reference meteorological conditions
Reference meteorological conditions for the purpose of calculating the sound power level, corresponding
−3
to a reference characteristic acoustic impedance of air ρc = 411,5 Nsm (where ρ is the density of air
and c is the speed of sound) are the following:
air temperature: 23,0 °C;
static pressure: 1,013 25 × 10 Pa;
4 © ISO 2016 – All rights reserved

relative humidity: 50 %.
5 Performance requirements
5.1 General
A manufacturer may only state that its RSS is in compliance with this International Standard if all of the
requirements laid out in this Clause are met.
5.2 Temporal steadiness (stability) of sound power output
The sound power level of the reference sound source shall be stable over time such that the measured
standard deviations under repeatability conditions, σ (see 8.3.3 and 9.3.2), do not exceed those
r
given in Table 1.
Table 1 — Maximum value of the standard deviation of the sound power level under repeatability
conditions for a reference sound source in accordance with this International Standard
Standard deviation
One-third-octave
under repeatability
midband frequency
conditions, σ
r
Hz
dB
50 to 80 0,8
100 to 160 0,4
200 to 20 000 0,2
NOTE 1 For special purposes, a reference sound source may have a more limited frequency range.
A reference sound source meeting the requirements of this International Standard shall include
information on the range of variation of the source of electrical or mechanical power (e.g. the line
voltage) within which the sound power level in any one-third-octave band within the frequency range
of interest shall not vary by more than ±0,3 dB.
NOTE 2 The sound power level of a reference sound source depends on the static pressure and the air temperature.
For the RSS to be used at different temperatures or altitudes, it is expected that information concerning appropriate
corrections, and their uncertainties, for the influence of air temperature and static pressure on sound power
emitted by the RSS, is included. For an aerodynamic fan RSS, the rotational speed and variations due to changing
meteorological conditions during the qualification test are found according to 8.4 and 9.4.
5.3 Total broadband sound power level
There are no specific requirements placed on the total broadband sound power level produced by
the RSS. However, if the total broadband sound power level is reported, either as an unweighted or
frequency-weighted quantity, the corresponding frequency range shall also be reported.
5.4 Spectral characteristics
The RSS shall produce broadband steady sound over the frequency range in which it is intended for
use, but at least for one-third-octave midband frequencies between 100 Hz and 10 000 Hz. Over this
frequency range, all of the one-third-octave-band sound power levels, when measured in conformity
with the requirements of Clause 8 and Clause 9, as applicable, shall be within a range of 12 dB. Under
these same measuring conditions, and over this same frequency range, the sound power level in each
one-third-octave band shall not deviate by more than 3 dB from the sound power level in the adjacent
higher or lower one-third-octave bands (the higher band only in the case of the 100 Hz band, and the
lower band only in the case of the 10 000 Hz band). If the frequency range is extended beyond 100 Hz to
10 000 Hz, then the requirements for the extended range are 16 dB and 4 dB, respectively.
It may be desirable for special sound sources to meet these criteria over a more limited frequency
range or for a different spectrum shape. However, if a RSS does not comply with the requirements of
this International Standard over at least the frequency range from 100 Hz to 10 000 Hz, it shall not be
labelled or declared as being in compliance with the frequency range of this International Standard.
5.5 Directivity
The highest value of the directivity index of the source in any one-third-octave band with midband
frequency between 100 Hz and 10 000 Hz shall not exceed +6 dB when measured in a hemi-anechoic
room complying with Clause 8.
If the RSS is to be used exclusively in reverberation test rooms complying with ISO 3741, these
requirements do not apply but in that case, the RSS shall be labelled “For use as a reference sound
source in reverberation test rooms complying with ISO 3741”.
5.6 Recalibration
5.6.1 Whenever any mechanical damage has been inflicted on the reference sound source, it shall be
recalibrated. For aerodynamic sound sources, measure the rotational speed (RPM) of the fanwheel. If
the present RPM after a few minutes stabilization deviates less than 1% from that found during the last
calibration, then the RSS is not electrically damaged.
5.6.2 The user manual for the reference sound source should provide the recommended maximum
time interval between successive calibrations such that changes in the sound power levels of the
specified model of the reference sound source is not expected to exceed 2,83 times the values in Table 1
(presumably from qualified historical tracking by the manufacturer). If this time interval is provided, it
shall be considered a requirement of this International Standard. If it is not provided in the user manual,
the maximum time interval shall be two years.
NOTE If the difference between two consecutive calibrations is less than 2,83 times the standard deviation,
[7]
there is, e.g. see ISO 5725-2 , a probability of 95 % that the temporal stability of the RSS complies with the
values given in Table 1.
5.6.3 In order to determine whether or not recalibration of a reference sound source is necessary
before the maximum time interval has expired, one-third-octave-band sound pressure levels shall be
measured regularly at one or more fixed reference points with the source operating at a specific location
in a specified test environment as a check of its temporal stability. The user manual for the reference
sound source should specify the time interval between such regular measurements. If this time interval
is provided, it shall be considered a requirement of this International Standard. If it is not provided in the
user manual, the time interval shall be a maximum of six months. If, after using manufacturer-specified
procedures to adjust the measured sound pressure levels to constant environmental conditions when
necessary, changes in any one-third-octave-band sound pressure level between successive checks exceed
2,83 times the values in Table 1, the reference sound source shall be recalibrated.
NOTE If the above check indicates the need for recalibration, confidence may be diminished in any data that
may have been taken with the reference sound source during the intervening time interval. In view of this, the
laboratory may decide on a much shorter time interval, or select a variable time interval based on the number of
tests it performs.
5.6.4 For laboratories using a reference sound source in a generally fixed location, in a controlled
environment without transporting it, calibration intervals may be extended beyond the maximum time
interval in 5.6.2 if changes in the surface time average band sound pressure levels measured at a maximum
of one-year intervals over positions 1 to 10 of ISO 3744:2010, Table B.1, using a fixed measurement radius
of at least 1 m, in an environment that has been qualified for broadband sound power level determination
in accordance with ISO 3745:2012, Annex A do not exceed 2,83 times the values in Table 1. Alternatively,
an equivalent test may be carried out with the RSS in one specified location in a reverberation room
following the procedures specified for measurements of sound pressure levels from a RSS in ISO 3741.
For this measurement, the reference sound source shall each time be measured at the same temperature,
6 © ISO 2016 – All rights reserved

pressure, and humidity within the tolerances specified in ISO 3741. The change in sound pressure levels
is hereby defined as the difference between the latest measurement and a reference measurement using
exactly the same test procedure that was carried out in connection with the arrival of the reference sound
source directly after the latest accredited calibration in full compliance with this International Standard.
Each check shall be documented.
However, the maximum permissible extension using this procedure is 10 years. After this period,
the reference sound source shall be subject to a new calibration by an authorized laboratory in full
compliance with this International Standard.
6 Instrumentation
6.1 General
For measurements conducted with a sound level meter, the instrument for measuring sound pressure
levels, including microphone(s) as well as cable(s), windscreen(s), recording devices and other
accessories, if used, shall meet the requirements of IEC 61672-1 for a class 1 sound level meter.
For measurements conducted using computerized data acquisition systems the complete measurement
system, including hardware and software components, shall be validated in accordance with the
periodic test requirements of IEC 61672-3. The validation shall be conducted for the requirements
specified in IEC 61672-3:2013, Clauses 8, 9, 10, 11, 14, 15, 16, 17, 18, and 20 at conditions that are
representative of those present in the environment where the measurements are conducted.
Proportional octave band filters for sound level meters or computerized data acquisition systems shall
meet the requirements of IEC 61260-1, class 1.
6.2 Microphone in a hemi-anechoic room
Use either a microphone with a nominally flat frequency response at normal incidence mounted with the
axis of the microphone (that runs perpendicular through the plane of the diaphragm) pointing towards
the centre of the measurement hemisphere, or a microphone with a nominally flat frequency response at
grazing incidence mounted with the axis of the microphone perpendicular to the line pointing towards
the centre of the measurement hemisphere. Microphones used as part of a sound level meter shall meet
the requirements of IEC 61672-1 for a class 1 sound level meter. Microphones used with computerized
data acquisition systems shall be of type LS or WS and shall have free field (F), pressure (P), or diffuse
field (D) response as defined by IEC 61094-1 and IEC 61094-4 respectively. Microphones shall be
validated in accordance with the periodic testing requirements of IEC 61672- 3:2013 for a class 1 sound
level meter and be individually frequency-corrected according to 6.4.
6.3 Microphone in a reverberation test room
Microphones used as a part of a sound level meter shall be of random incidence type (or corrected
to random incidence) and shall be calibrated in accordance with IEC 61183 and shall meet the
requirements of IEC 61672-1 for a class 1 sound level meter. Microphones used with computerized
data acquisition systems shall be of type WS and shall have diffuse field (D) response as defined by
IEC 61094-4. Microphones shall be validated in accordance with the periodic testing requirements of
IEC 61672-3 for a class 1 sound level meter and be individually frequency-corrected according to 6.4.
6.4 Microphone frequency response correction
Microphones for use in hemi-anechoic rooms shall be provided with frequency response corrections
obtained in accordance with IEC 62585. Microphones for use in reverberation rooms shall be provided
with frequency response corrections obtained in accordance with IEC 61183.
The microphone response shall be corrected (usually using one-third-octave-band corrections obtained
from an accredited microphone calibration performed in an accredited or otherwise nationally
authorized laboratory) with a precision of 0,1 dB to give a nominally flat frequency response, in a
hemi-anechoic room at normal incidence or grazing incidence and in a reverberation room at random
incidence over the frequency range of interest.
If the frequency range is extended above the 10 000 Hz one-third-octave band, there may be a
small difference in frequency response accuracy between the two microphone types. The data on
measurement uncertainty given in Table 2 are based on measurements using microphones with a
nominally flat frequency response at grazing incidence.
6.5 Verification
Compliance of the sound pressure level measuring instrument, the filters, microphone and the sound
calibrator with the requirements specified herein shall be verified by the existence of a valid certificate
of compliance with the measurement parameters specified in the test method.
All certificates of compliance shall state that compliance testing was conducted by a laboratory being
accredited or otherwise nationally authorized to perform the relevant tests and calibrations and
ensuring metrological traceability to the appropriate measurement standards.
Unless national regulations dictate otherwise, it is recommended that
— the sound calibrator should be calibrated at intervals not exceeding one year,
— the compliance of the instrumentation system with the requirements stated in 6.1 should be verified
at intervals not exceeding two years, and
— the compliance of an analog filter set should be verified with the requirements of IEC 61260-
1 at intervals not exceeding two years. Digital filter sets should be verified with a certificate of
compliance with the requirements of IEC 61260-1 and should be updated any time the algorithms
associated with the filters are changed.
Periodic calibration shall be conducted by a laboratory being accredited or otherwise nationally
authorized to perform the relevant tests and calibrations and ensuring metrological traceability to the
appropriate measurement standards.
6.6 Microphone calibration check
At the beginning and at the end of every measurement session, the entire sound pressure level
measuring system shall be checked at one or more frequencies by means of a sound calibrator meeting
the requirements for a class 1 calibrator as specified in IEC 60942. Without any further adjustment, the
difference between the readings of two consecutive checks shall not exceed 0,2 dB. If this value is exceeded,
the results of all measurements obtained after the previous satisfactory check shall be discarded.
7 Installation and operation of the reference sound source during calibration
7.1 General
The RSS under test shall be operated in accordance with the manufacturer’s instructions. The essential
characteristics of the source of mechanical or electrical power (e.g. line voltage and frequency) and the
relevant operating parameters of the reference sound source (e.g. rotational speed of an aerodynamic
source) shall be recorded.
NOTE It might be necessary to use auxiliary equipment to measure the relevant operating parameters (e.g. a
stroboscope to determine rotational speed).
The RSS shall be in a stable operating condition before any measurements (either of acoustic properties
or of operating parameters) are made.
8 © ISO 2016 – All rights reserved

7.2 Requirements in hemi-anechoic rooms
In a hemi-anechoic room, place the RSS to be calibrated on the reflecting plane, oriented as in normal
usage and at least 1,0 m from the nearest wall.
Reference sound sources in positions more than 0,5 m from the reflecting plane cannot be calibrated in
hemi-anechoic rooms.
7.3 Requirements in reverberation rooms
In a reverberation test room, place the RSS on the floor unsymmetrically in relation to the walls and at
least 1,5 m from the nearest wall. Use four such positions at least 2 m from each other. Alternatively, the
RSS can be calibrated in specified positions above the floor and close to the walls.
8 Calibration procedure in hemi-anechoic rooms
8.1 Test environment
The test environment shall be a hemi-anechoic room meeting the broadband qualification requirements
of ISO 3745:2012, Annex A, over the frequency range of interest.
8.2 Microphone positions
8.2.1 General
Use a hemispherical measurement surface with a radius of 2 m. Centre it over the geometrical centre
of the projection of the top surface of the RSS on the reflecting plane. Use one of the sets of microphone
positions given in 8.2.2, 8.2.3, 8.2.4 or 8.2.5. Take care that the mechanical arrangement for fixing or
traversing the microphone does not affect the measurements.
8.2.2 Meridional paths
Follow the procedures of ISO 3745:2012, 9.3.5 and Annex G. For sources with rotational symmetry,
use three traverses at 120° increments around the vertical axis of the measurement surface. For other
sources, use at least eight traverses.
NOTE 1 W
...


NORME ISO
INTERNATIONALE 6926
Troisième édition
2016-01-15
Acoustique — Prescriptions relatives
aux performances et à l’étalonnage
des sources sonores de référence
pour la détermination des niveaux de
puissance acoustique
Acoustics — Requirements for the performance and calibration of
reference sound sources used for the determination of sound power
levels
Numéro de référence
©
ISO 2016
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2016, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – Tous droits réservés

Sommaire Page
Avant-propos .v
Introduction .vi
1 Domaine d’application . 1
2 Références normatives . 2
3 Termes et définitions . 2
4 Conditions météorologiques de référence . 5
5 Exigences de performance . 5
5.1 Généralités . 5
5.2 Stabilité dans le temps de la puissance acoustique émise . 5
5.3 Niveau global de puissance acoustique à large bande . 6
5.4 Caractéristiques spectrales . 6
5.5 Directivité . 6
5.6 Réétalonnage . 6
6 Appareillage . 7
6.1 Généralités . 7
6.2 Microphone dans une salle semi-anéchoïque . 8
6.3 Microphone dans une salle d’essai réverbérante . 8
6.4 Correction de la réponse en fréquence d’un microphone . 8
6.5 Vérification de la conformité . 8
6.6 Contrôle de l’étalonnage d’un microphone . 9
7 Installation et fonctionnement de la source sonore de référence pendant l’étalonnage .9
7.1 Généralités . 9
7.2 Exigences applicables aux salles semi-anéchoïques . 9
7.3 Exigences applicables aux salles réverbérantes . 9
8 Mode opératoire d’étalonnage en salle semi-anéchoïque .10
8.1 Environnement d’essai . .10
8.2 Positions des microphones .10
8.2.1 Généralités .10
8.2.2 Trajets méridiens .10
8.2.3 Trajet en spirale .10
8.2.4 Configuration à points fixes .10
8.2.5 Trajets circulaires coaxiaux .10
8.3 Mesurages .11
8.3.1 Généralités .11
8.3.2 Indice de directivité . .11
8.3.3 Stabilité dans le temps .11
8.4 Calculs .12
9 Mode opératoire d’étalonnage en salles d’essai réverbérantes .13
9.1 Environnement d’essai . .13
9.2 Positions des microphones .13
9.3 Mesurages .13
9.3.1 Généralités .13
9.3.2 Stabilité dans le temps .14
9.4 Calculs .14
10 Mode opératoire de remplacement pour l’étalonnage aux basses fréquences .14
11 Incertitude de mesure .14
11.1 Généralités .14
11.2 Valeurs types de l’écart-type de reproductibilité .15
12 Informations à consigner .16
13 Informations à fournir dans le rapport d’essai .16
Annexe A (informative) Guide de détermination de C .18
Annexe B (normative) Mode opératoire de remplacement pour l’étalonnage aux
basses fréquences .20
Bibliographie .21
iv © ISO 2016 – Tous droits réservés

Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www.
iso.org/directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer
un engagement.
Pour une explication de la signification des termes et expressions spécifiques de l’ISO liés à
l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion de l’ISO aux principes
de l’OMC concernant les obstacles techniques au commerce (OTC), voir le lien suivant: Avant-propos —
Informations supplémentaires.
Le comité chargé de l’élaboration du présent document est l’ISO/TC 43, Acoustique, sous-comité SC 1, Bruit.
Cette troisième édition annule et remplace la deuxième édition (ISO 6926:1999), qui a fait l’objet des
modifications techniques suivantes:
— mise à jour de l’article relatif à l’incertitude de mesure avec une référence plus stricte au
Guide ISO/IEC 98-3 et repositionnement de cet article dans la norme afin d’offrir une meilleure
cohérence avec l’ISO 3745;
— alignement des corrections associées aux conditions météorologiques avec celles de l’ISO 3745 et
introduction d’une nouvelle Annexe A sur la correction d’impédance de rayonnement acoustique;
— introduction dans une nouvelle Annexe B d’une méthode utilisant l’intensité acoustique pour
l’étalonnage à basse fréquence dans des salles semi-anéchoïques qui ne sont pas complètement
qualifiées pour les basses fréquences.
Introduction
L’emploi de sources sonores de référence pour la détermination, par des méthodes dites de comparaison,
de l’émission sonore des sources fixes est largement répandu. Ces méthodes utilisent une source sonore
de référence de puissance acoustique connue pour établir la relation numérique existant entre le niveau
de puissance acoustique d’une source sonore, en un point donné et dans un environnement défini, et
la moyenne dans le temps et dans l’espace du niveau de pression acoustique mesuré à un ensemble
de positions de microphone. Une fois cette relation établie, il suffit de mesurer le niveau de pression
acoustique moyen émis par une « source inconnue » pour déterminer son niveau de puissance acoustique.
La présente Norme internationale définit les caractéristiques physiques importantes et celles
relatives aux performances des sources sonores de référence et prescrit les méthodes d’étalonnage de
ces sources, principalement en vue de leur utilisation pour la détermination du niveau de puissance
acoustique d’autres sources sonores.
La présente Norme internationale complète le groupe ou la famille de Normes internationales ISO 3740,
qui décrivent diverses méthodes de détermination des niveaux de puissance acoustique des machines
et équipements. Ce groupe de Normes internationales spécifie, pour différents environnements d’essai,
les exigences acoustiques s’appliquant aux mesurages.
Cinq des Normes internationales du groupe ISO 3740 définissent des modes opératoires faisant intervenir
une source sonore de référence: ISO 3741, ISO 3743-1, ISO 3744, ISO 3746 et ISO 3747. L’ISO 3740 établit
les lignes directrices pour l’utilisation de l’ensemble des Normes internationales de ce groupe.
Noter que la puissance acoustique des sources sonores de référence varie, en particulier aux fréquences
basses, en fonction de la distance entre la source et les plans réfléchissants avoisinants. Par conséquent,
les données de puissance acoustique des sources sonores de référence ne sont valables que pour la
position utilisée pendant l’étalonnage.
Outre leur utilité pour la détermination des niveaux de puissance acoustique par la méthode
de comparaison, les sources sonores de référence peuvent servir aux essais de qualification
d’environnements acoustiques et à l’évaluation de l’influence d’un environnement acoustique sur
les niveaux de pression acoustique produits par une ou plusieurs sources sonores situées dans cet
environnement. Les Normes internationales ISO/TR 11690-3 et ISO 14257, par exemple, font appel à des
sources sonores de référence pour ce type d’applications. D’autres exigences que celles de la présente
Norme internationale peuvent s’appliquer à ces sources.
vi © ISO 2016 – Tous droits réservés

NORME INTERNATIONALE ISO 6926:2016(F)
Acoustique — Prescriptions relatives aux performances
et à l’étalonnage des sources sonores de référence pour la
détermination des niveaux de puissance acoustique
1 Domaine d’application
La présente Norme internationale spécifie les exigences relatives aux performances acoustiques des
sources sonores de référence:
— stabilité dans le temps de la puissance acoustique émise;
— caractéristiques spectrales;
— directivité.
La stabilité dans le temps est définie en termes d’écart-type de répétabilité (voir 5.2). Les
caractéristiques spectrales peuvent être vérifiées soit dans une salle semi-anéchoïque, soit dans une
salle d’essai réverbérante, à partir du mesurage des niveaux de puissance acoustique par bande de
fréquences conformément à la présente Norme internationale (voir 5.4). Les exigences de performance
relatives à l’indice de directivité ne peuvent être vérifiées que dans une salle semi-anéchoïque (voir 5.5).
La présente Norme internationale définit également des modes opératoires pour obtenir les données
et l’incertitude de l’étalonnage des niveaux d’une source sonore destinée à être utilisée comme source
sonore de référence, le résultat étant exprimé par un niveau de puissance acoustique par bandes
d’octave et de tiers d’octave, et avec la pondération fréquentielle A, dans les conditions météorologiques
de référence telles que définies à l’Article 4.
La présente Norme internationale est appelée norme d’étalonnage bien que la méthode soit applicable
dans un laboratoire d’essai et que les résultats de l’étalonnage des niveaux ne se rapportent pas
directement à des normes nationales de mesure dans un sens métrologique strict. Il n’est pas attendu
que les laboratoires d’essai appliquant cette méthode satisfassent à toutes les exigences normalement
associées à un laboratoire d’étalonnage.
[15]
NOTE L’ISO/IEC 17025 spécifie différentes exigences pour les compétences respectives des laboratoires
d’essai et des laboratoires d’étalonnage. Les laboratoires qui soumettent à l’essai des sources sonores de
référence conformément à la présente Norme internationale doivent normalement se conformer aux exigences
des laboratoires d’essai, mais pas nécessairement à celles des laboratoires d’étalonnage.
La présente Norme internationale spécifie des méthodes d’étalonnage pour les sources sonores de
référence non seulement en champ libre au-dessus d’un plan réfléchissant, mais aussi dans des salles
d’essais réverbérantes à diverses distances des surfaces délimitantes. Pour la position de la source
sonore de référence au-dessus d’un plan réfléchissant unique, les deux environnements d’essai
différents mentionnés ci-dessus sont considérés comme équivalents pour les bandes de fréquences
supérieures ou égales à 200 Hz. À 160 Hz et au-dessous, des écarts systématiques peuvent exister
(voir 11.2). Pour les fréquences inférieures à 100 Hz, une autre méthode d’étalonnage utilisant
l’intensité acoustique est donnée.
La source sonore peut être conçue spécifiquement soit pour être posée directement sur le sol, soit
pour être montée sur un support afin d’être utilisée à une certaine distance du sol. Conformément à
la présente Norme internationale, les sources montées sur un support sont étalonnées dans des salles
d’essai réverbérantes. Les sources au sol sont étalonnées dans des salles d’essai semi-anéchoïques ou
réverbérantes. Pour des sources au sol en salles semi-anéchoïques, la présente Norme internationale
s’applique uniquement aux sources dont la dimension verticale maximale est inférieure à 0,5 m et
dont la dimension horizontale maximale est inférieure à 0,8 m. Conformément à la présente Norme
internationale, seules les sources sonores de référence posées au sol peuvent être utilisées pour
effectuer des mesurages sur une surface. Les restrictions applicables aux dimensions maximales
ci-dessus ne s’appliquent pas aux sources sonores de référence destinées à être utilisées ou étalonnées
dans des conditions de champ réverbéré.
2 Références normatives
Les documents ci-après, dans leur intégralité ou non, sont des références normatives indispensables à
l’application du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les
références non datées, la dernière édition du document de référence s’applique (y compris les éventuels
amendements).
ISO 3741:2010, Acoustique — Détermination des niveaux de puissance acoustique et des niveaux d’énergie
acoustique émis par les sources de bruit à partir de la pression acoustique — Méthodes de laboratoire en
salles d’essais réverbérantes.
ISO 3744:2010, Acoustique — Détermination des niveaux de puissance acoustique et des niveaux d’énergie
acoustique émis par les sources de bruit à partir de la pression acoustique — Méthodes d’expertise pour des
conditions approchant celles du champ libre sur plan réfléchissant.
ISO 3745:2012, Acoustique — Détermination des niveaux de puissance acoustique et des niveaux d’énergie
acoustique émis par les sources de bruit à partir de la pression acoustique — Méthodes de laboratoire pour
les salles anéchoïques et les salles semi-anéchoïques
ISO 9613-1:1993, Acoustique — Atténuation du son lors de sa propagation à l’air libre — Partie 1: Calcul de
l’absorption atmosphérique
ISO 9614-3, Acoustique — Détermination par intensimétrie des niveaux de puissance acoustique émis par
les sources de bruit — Partie 3: Méthode de précision pour mesurage par balayage.
IEC 60942:2003, Électroacoustique — Calibreurs acoustiques.
IEC 61094-1, Microphones de mesure — Partie 1: Spécifications des microphones étalons de laboratoire.
IEC 61094-4, Microphones de mesure — Partie 4: Spécifications des microphones étalons de travail.
IEC 61183, Électroacoustique — Étalonnage des sonomètres sous incidence aléatoire et en champ diffus.
IEC 61260-1,Électroacoustique — Filtres de bande d’octave et de bande d’une fraction d’octave — Partie 1:
Spécifications.
IEC 61672-1, Électroacoustique — Sonomètres — Partie 1: Spécifications.
IEC 61672-3:2013,Électroacoustique — Sonomètres — Partie 3: Essais périodiques.
IEC 62585,Électroacoustique — Méthodes de détermination de corrections pour obtenir la réponse en
champ libre d’un sonomètre.
Guide ISO/IEC 98-3, Incertitude de mesure — Partie 3: Guide pour l’expression de l’incertitude de
mesure (GUM:1995).
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
3.1
source sonore de référence
RSS
source sonore portable, généralement électroacoustique ou aérodynamique ou tout autre dispositif
générateur de bruit, ainsi que le circuit de commande associé, donnant une émission sonore stable à
large bande conformément aux exigences de la présente Norme internationale
2 © ISO 2016 – Tous droits réservés

3.2
champ acoustique libre au-dessus d’un plan réfléchissant
dans un milieu homogène et isotrope, champ acoustique dans le demi-espace situé au-dessus d’une
surface plane réfléchissante infinie en l’absence d’autres obstacles réfléchissants
3.3
salle semi-anéchoïque
salle d’essai dans laquelle un champ acoustique libre au-dessus d’un plan réfléchissant est obtenu
3.4
salle d’essai réverbérante
salle d’essai conforme aux exigences de l’ISO 3741
3.5
surface de mesurage
surface fictive d’aire S, sur laquelle sont situées les positions de microphone auxquelles les niveaux
de pression acoustique sont mesurés, entourant la source soumise à l’essai et, dans le cas d’une salle
semi-anéchoïque, se terminant sur le plan réfléchissant sur lequel est située la source
Note 1 à l’article: L’aire de la surface de mesurage est exprimée en mètres carrés.
3.6
niveau de pression acoustique surfacique
L
p
moyenne énergétique des niveaux de pression acoustique temporels moyens à toutes les positions de
microphone, ou trajets microphoniques, sur la surface de mesurage, avec la correction du bruit de fond,
K , appliquée à chaque position ou déplacement de microphone
Note 1 à l’article: Le niveau de pression acoustique surfacique est exprimé en décibels.
Note 2 à l’article: Pour la définition et le calcul de K , voir l’ISO 3745.
3.7
niveau de puissance acoustique
L
W
dix fois le logarithme décimal du rapport de la puissance acoustique d’une source, P, à une valeur de
référence, P , exprimé en décibels
P
L =10lg dB
W
P
où la valeur de référence, P , est 1 pW
Note 1 à l’article: Si une pondération spécifique telle que spécifiée dans l’IEC 61672–1 et/ou des bandes de
fréquences spécifiques sont appliquées, il convient que cela soit indiqué par des indices appropriés; par ex. L
WA
représente le niveau de puissance acoustique pondéré A.
[17]
Note 2 à l’article: Cette définition est techniquement en conformité avec l’ISO 80000-8:2007, 8-23.
[SOURCE: ISO/TR 25417:2007, 2.9]
3.8
rayon de mesurage
r
rayon d’une surface de mesurage hémisphérique
3.9
indice de directivité
D
Ii
mesure du degré de rayonnement d’une source sonore dans une direction donnée, par rapport au
rayonnement sonore moyen sur la surface de mesurage, où pour des microphones fixes, la direction est
orientée de la source vers la position du microphone, et pour des trajets microphoniques, la direction
est orientée de la source vers la position le long du trajet microphonique sur lequel le niveau de pression
acoustique le plus élevé est enregistré
Note 1 à l’article: L’indice de directivité dans la direction i se calcule à partir des mesures obtenues en salle semi-
anéchoïque avec la formule suivante:
DL=−L
Ii pi p

L est le niveau de pression acoustique dans chaque bande de
pi
ème
tiers d’octave à la i position du microphone sur la surface de mesurage, en décibels;
L est le niveau maximal de la pression acoustique
pi
ème
pour chaque bande de tiers d’octave qui est enregistrée pendant le i déplacement du
microphone (voir 8.2) sur la surface de mesurage, en décibels;
est la moyenne du niveau de pression acoustique surfacique sur la même surface de mesu-
L
p
rage, en décibels.
Note 2 à l’article: Avec la définition «opérationnelle» ci-dessus, l’indice de directivité est une mesure de
l’uniformité du rayonnement sonore de la source sur la surface de mesurage spécifique employée et telle qu’elle
est installée dans l’environnement d’essai. Les définitions de l’indice de directivité «théorique» figurant dans les
livres et la littérature représentent généralement l’uniformité du rayonnement sonore en comparant la source
soumise à l’essai dans son environnement d’essai à une source ponctuelle de la même puissance acoustique
rayonnant dans une sphère complète, dans un champ complètement libre. Lorsque de telles définitions sont
appliquées aux sources situées dans un champ libre au-dessus d’un plan réfléchissant, elles incluent une
constante de «+3 dB» pour tenir compte du rayonnement hémisphérique. Il convient d’être vigilant lors de la
comparaison ou de l’utilisation de définitions différentes de l’indice de directivité.
3.10
domaine de fréquences représentatif
le domaine de fréquences des bandes de tiers d’octave dont les fréquences médianes nominales sont
comprises entre 100 Hz et 10 000 Hz
Note 1 à l’article: Le domaine de fréquences représentatif des bandes de tiers d’octave peut être étendu jusqu’à
20 000 Hz ou réduit jusqu’à 50 Hz, sous réserve que les exigences de la présente Norme internationale soient
toujours respectées.
3.11
méthode de comparaison
méthode par laquelle le niveau de puissance acoustique est calculé en comparant les niveaux de pression
acoustique produits par la source soumise à l’essai, dans un environnement donné, avec les niveaux
de pression acoustique produits, dans le même environnement, par une source sonore de référence de
puissance acoustique connue
3.12
méthode directe
méthode utilisée dans les salles d’essai réverbérantes où le niveau de puissance acoustique est calculé
à l’aide de la surface d’absorption acoustique équivalente déterminée à partir des mesurages du temps
de réverbération
4 © ISO 2016 – Tous droits réservés

3.13
temps de réverbération
T
temps nécessaire pour que le niveau de pression acoustique diminue de 60 dB après l’arrêt de la
source sonore
Note 1 à l’article: T ou T sont respectivement les temps de réverbération calculés à partir des premiers 10 dB
10 15
ou 15 dB d’atténuation.
Note 2 à l’article: Il est exprimé en secondes.
3.14
condition de répétabilité
condition dans laquelle des résultats d’essais indépendants sont obtenus avec la même méthode, sur
des éléments d’essai identiques, dans le même laboratoire, par le même opérateur utilisant le même
équipement à des intervalles de temps brefs
4 Conditions météorologiques de référence
Les conditions météorologiques de référence pour les besoins du calcul du niveau de puissance
−3
acoustique, correspondant à une impédance acoustique caractéristique de l’air ρc = 411,5 Nsm (où ρ
est la densité de l’air et c est la vitesse du son) sont les suivantes:
température de l’air: 23,0 °C;
pression statique: 1,013 25 × 10 Pa;
humidité relative: 50 %.
5 Exigences de performance
5.1 Généralités
Un fabricant ne peut annoncer que sa source sonore de référence est conforme à la présente Norme
internationale que si toutes les exigences spécifiées dans le présent article sont satisfaites.
5.2 Stabilité dans le temps de la puissance acoustique émise
Le niveau de puissance acoustique de la source sonore de référence doit être stable dans le temps,
de sorte que les écarts-types mesurés dans des conditions de répétabilité, σ (voir 8.3.3 et 9.3.2), ne
r
dépassent pas les valeurs indiquées dans le Tableau 1.
Tableau 1 — Valeurs maximales dans des conditions de répétabilité de l’écart-type des niveaux
de puissance acoustique des sources sonores de référence conformément à la présente Norme
internationale
Fréquence médiane Écart-type dans des conditions
des bandes de tiers d’octave de répétabilité, σ
r
Hz dB
50 à 80 0,8
100 à 160 0,4
200 à 20 000 0,2
NOTE 1 Pour des applications spécifiques, une source sonore de référence peut couvrir un domaine de
fréquences plus limité.
Une source sonore de référence satisfaisant aux exigences de la présente Norme internationale doit
être accompagnée d’informations relatives à la plage de variation de la source d’énergie électrique ou
mécanique (par exemple la tension du réseau) qui correspond à une variation maximale de ± 0,3 dB du
niveau de puissance acoustique, quelle que soit la bande de tiers d’octave considérée du domaine de
fréquences représentatif.
NOTE 2 Le niveau de puissance acoustique d’une source sonore de référence dépend de la pression statique et
de la température de l’air. Pour l’utilisation de la source sonore de référence à d’autres températures ou altitudes,
il est attendu que les informations relatives aux corrections appropriées et aux incertitudes correspondantes,
permettant de rendre compte de l’influence de la température de l’air et de la pression statique sur le niveau de
puissance acoustique émis par la source sonore de référence, soient incluses. Pour une source sonore de référence
à ventilateur aérodynamique, la vitesse de rotation et les variations dues aux conditions météorologiques
variables pendant l’essai de qualification sont obtenues conformément à 8.4 et 9.4.
5.3 Niveau global de puissance acoustique à large bande
Il n’est pas fixé d’exigences spécifiques pour le niveau global de puissance acoustique à large bande
émis par une source sonore de référence. Si toutefois une valeur est inscrite dans la notice, qu’elle soit
pondérée en fréquence ou non, le domaine de fréquences correspondant doit être également indiqué.
5.4 Caractéristiques spectrales
La source sonore de référence doit émettre un son stable en bande large dans le domaine de fréquences
pour lequel son utilisation est prévue, mais au moins dans les bandes de tiers d’octave de fréquences
médianes comprises entre 100 Hz et 10 000 Hz. Dans ce domaine de fréquences, tous les niveaux de
puissance acoustique par bande de tiers d’octave, mesurés conformément aux exigences de l’Article 8
et de l’Article 9, suivant le cas, doivent être compris dans un intervalle de 12 dB. Dans ces mêmes
conditions de mesurage, et sur le même domaine de fréquences, le niveau de puissance acoustique dans
chaque bande de tiers d’octave ne doit pas s’écarter de plus de 3 dB du niveau de puissance acoustique
dans les bandes de tiers d’octave supérieure ou inférieure adjacentes (bande supérieure uniquement
dans le cas de la bande de 100 Hz et bande inférieure uniquement dans le cas de la bande de 10 000 Hz).
Si le domaine de fréquences s’étend au-delà de la plage 100 Hz à 10 000 Hz, les exigences pour l’extension
du domaine sont alors respectivement de 16 dB et 4 dB.
Il peut être souhaitable, pour des sources sonores spéciales, de répondre à ces critères dans un
domaine de fréquences plus limité ou pour un spectre de forme différente. Cependant, si une source
sonore de référence n’est pas conforme aux exigences de la présente Norme internationale au moins sur
le domaine de fréquences compris entre 100 Hz et 10 000 Hz, elle ne doit pas être étiquetée ou déclarée
comme étant en conformité avec le domaine de fréquences de la présente Norme internationale.
5.5 Directivité
Quelle que soit la bande de tiers d’octave de fréquence médiane comprise entre 100 Hz et 10 000 Hz
considérée, la valeur maximale de l’indice de directivité de la source ne doit pas dépasser +6 dB lorsque
celui-ci est mesuré en salle semi-anéchoïque conformément aux exigences de l’Article 8.
Si la source sonore de référence doit être utilisée exclusivement en salles d’essai réverbérantes
conformes à l’ISO 3741, ces exigences ne s’appliquent pas, mais dans ce cas, la source sonore de référence
doit porter une étiquette précisant «Source sonore de référence utilisable uniquement en salle d’essai
réverbérante conforme à l’ISO 3741».
5.6 Réétalonnage
5.6.1 Si la source sonore de référence a subi des dommages mécaniques, elle doit faire l’objet d’un
réétalonnage. Pour les sources sonores aérodynamiques, mesurer la vitesse de rotation (tours par
minute) du ventilateur. Si, après une stabilisation de quelques minutes, la vitesse de rotation s’écarte de
moins de 1 % de celle relevée lors du dernier étalonnage, la source sonore de référence n’a pas subi de
dommages électriques.
6 © ISO 2016 – Tous droits réservés

5.6.2 Il convient que le manuel d’utilisation de la source sonore de référence indique le délai maximal
recommandé entre des étalonnages successifs de sorte que les variations des niveaux de puissance
acoustique du modèle de source sonore de référence spécifié ne dépassent pas 2,83 fois les valeurs du
Tableau 1 (indication établie à partir d’un historique qualifié réalisé par le fabricant). Lorsque ce délai
est indiqué, il doit être considéré comme une exigence de la présente Norme internationale. Si le manuel
d’utilisation ne le spécifie pas, le délai maximal doit être de deux ans.
NOTE Si la différence entre deux étalonnages consécutifs est inférieure à 2,83 fois l’écart-type, il existe (par
ex. voir l’ISO 5725-2 [7]) une probabilité de 95 % que la stabilité dans le temps de la source sonore de référence
soit conforme aux valeurs du Tableau 1.
5.6.3 Pour déterminer s’il est nécessaire ou non de procéder au réétalonnage d’une source sonore
de référence avant l’expiration du délai maximal, les niveaux de pression acoustique par bande de tiers
d’octave doivent être mesurés à intervalle régulier en un ou plusieurs points de référence fixes, la source
fonctionnant en un emplacement spécifique dans un environnement d’essai spécifié afin de vérifier sa
stabilité dans le temps. Il convient que le manuel d’utilisation de la source sonore de référence précise le
délai à respecter entre ces mesurages réguliers. Lorsque ce délai est indiqué, il doit être considéré comme
une exigence de la présente Norme internationale. Si le manuel d’utilisation ne le spécifie pas, le délai
doit être au maximum de six mois. Si, après application des méthodes spécifiées par le fabricant pour
l’ajustement des valeurs mesurées du niveau de pression acoustique à des conditions d’environnement
constantes, les variations du niveau de pression acoustique dans une bande de tiers d’octave entre des
vérifications successives dépassent 2,83 fois les valeurs du Tableau 1, la source sonore de référence doit
faire l’objet d’un réétalonnage.
NOTE Si la nécessité d’un réétalonnage apparaît suite à ces vérifications, le degré de confiance des données
obtenues avec la source sonore de référence pendant cet intervalle peut être réduit. À cet égard, le laboratoire
peut décider de réduire le délai entre les vérifications, ou encore de choisir un délai variable en fonction du
nombre d’essais réalisés.
5.6.4 Pour les laboratoires utilisant une source sonore de référence fonctionnant en un emplacement
fixe dans un environnement contrôlé et sans aucun déplacement, les intervalles d’étalonnage peuvent
être étendus au-delà du délai maximal indiqué en 5.6.2 à condition que les variations des niveaux de
pression acoustique surfaciques temporels moyens mesurés tous les douze mois au maximum, aux
emplacements 1 à 10 de l’ISO 3744:2010, Tableau B.1, avec un rayon de mesurage minimal de 1 m, dans
un environnement qualifié pour la détermination du niveau de puissance acoustique à large bande
conformément à l’ISO 3745:2012, Annexe A, ne soient pas supérieures à 2,83 fois les valeurs du Tableau 1.
Autrement, un essai équivalent peut être réalisé avec la source sonore de référence positionnée à un
emplacement spécifié dans une salle réverbérante selon les modes opératoires de mesurage des niveaux
de pression acoustique à partir d’une source sonore de référence définis dans l’ISO 3741. Dans ce cas,
les mesurages doivent tous être réalisés dans des conditions identiques de température, de pression
et d’humidité en tenant compte des tolérances spécifiées dans l’ISO 3741. La variation des niveaux de
pression acoustique est alors définie comme la différence entre la dernière mesure et une mesure de
référence utilisant exactement le même mode opératoire d’essai que celui appliqué à l’arrivée de la
source sonore de référence, directement après le dernier étalonnage agréé en totale conformité avec la
présente Norme internationale. Chaque vérification doit être documentée.
Noter cependant que l’extension maximale autorisée avec ce mode opératoire est de 10 ans. À l’issue
de cette période, la source sonore de référence doit être soumise à un nouvel étalonnage réalisé par un
laboratoire agréé en totale conformité avec la présente Norme internationale.
6 Appareillage
6.1 Généralités
Pour les mesurages réalisés avec un sonomètre, l’instrument de mesure des niveaux de pression
acoustique, y compris microphone(s), câble(s), écran(s) anti-vent, dispositif d’enregistrement
et autres accessoires, le cas échéant, doit être conforme aux exigences de l’IEC 61672-1 pour les
sonomètres de Classe 1.
Pour les mesurages réalisés avec des systèmes informatiques d’acquisition de données, l’ensemble du
système de mesurage, y compris les composants matériels et logiciels, doit être validé conformément
aux exigences d’essais périodiques de l’IEC 61672-3. Cette validation doit concerner les exigences
stipulées dans l’IEC 61672-3:2013, Articles 8, 9, 10, 11, 14, 15, 16, 17, 18 et 20, et être réalisée dans des
conditions représentatives de l’environnement dans lequel sont effectués les mesurages.
Les filtres de bande d’octave proportionnelle destinés aux sonomètres ou aux systèmes informatiques
d’acquisition de données doivent être conformes aux exigences de l’IEC 61260-1, Classe 1.
6.2 Microphone dans une salle semi-anéchoïque
Utiliser soit un microphone avec une réponse en fréquence nominalement plate, sous incidence normale,
monté avec l’axe du microphone (qui est perpendiculaire au plan du diaphragme) pointant vers le centre
de l’hémisphère de mesurage, soit un microphone avec une réponse en fréquence nominalement plate,
sous incidence rasante, monté avec l’axe du microphone perpendiculaire à la ligne pointant vers le centre
de l’hémisphère de mesurage. Les microphones utilisés avec un sonomètre doivent être conformes aux
exigences de l’IEC 61672-1 pour les sonomètres de Classe 1. Les microphones utilisés avec des systèmes
informatiques d’acquisition de données doivent être de type LS ou WS et doivent avoir une réponse en
champ libre (F), en pression (P) ou en champ diffus (D), tel que défini respectivement par l’IEC 61094-1
et l’IEC 61094-4. Les microphones doivent être validés conformément aux exigences d’essais périodiques
de l’IEC 61672-3:2013 pour les sonomètres de Classe 1 et leur réponse en fréquence doit être corrigée
de manière individuelle conformément à 6.4.
6.3 Microphone dans une salle d’essai réverbérante
Les microphones utilisés avec un sonomètre doivent être du type à incidence aléatoire (ou être ajustés
pour une incidence aléatoire) et doivent être étalonnés conformément à l’IEC 61183. Ils doivent en
outre être conformes aux exigences de l’IEC 61672-1 pour les sonomètres de Classe 1. Les microphones
utilisés avec des systèmes informatiques d’acquisition de données doivent être du type WS et avoir une
réponse en champ diffus (D) telle que définie dans l’IEC 61094-4. Les microphones doivent être validés
conformément aux exigences d’essais périodiques de l’IEC 61672-3 pour les sonomètres de Classe 1 et
leur réponse en fréquence doit être corrigée de manière individuelle conformément à 6.4.
6.4 Correction de la réponse en fréquence d’un microphone
Les microphones destinés aux salles semi-anéchoïques doivent être soumis à des corrections de
leur réponse en fréquence obtenues conformément à l’IEC 62585. Les microphones destinés aux
salles réverbérantes doivent être soumis à des corrections de leur réponse en fréquence obtenues
conformément à l’IEC 61183.
La réponse en fréquence du microphone doit être corrigée (généralement en utilisant les corrections de
bande de tiers d’octave obtenues par un étalonnage agréé du microphone dans un laboratoire agréé ou
autorisé) pour être nominalement plate à 0,1 dB près, dans une salle semi-anéchoïque sous incidence
normale ou sous incidence rasante ou dans une salle réverbérante sous incidence aléatoire, à l’intérieur
du domaine de fréquences représentatif.
Si le domaine de fréquences dépasse la bande de tiers d’octave de 10 000 Hz, il peut exister une légère
différence d’exactitude de la réponse en fréquence entre les deux types de microphone. Les données
sur l’incertitude de mesure indiquées dans le Tableau 2 s’appuient sur des mesurages utilisant des
microphones avec une ré
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...