Abstract

This document specifies the measurement methods for gaseous and particulate exhaust emissions from reciprocating internal combustion (RIC) engines on a test bed, necessary for determining one weighted value for each exhaust gas pollutant. Various combinations of engine load and speed reflect different engine applications (see ISO 8178‑4). This document is applicable to RIC engines for mobile, transportable and stationary use, excluding engines for motor vehicles primarily designed for road use. This document can be applied to engines used, for example, for earth-moving machines, generating sets and for other applications.

Status
Not Published
Current Stage
5020 - Proof sent to secretariat or FDIS ballot initiated: 8 weeks - 50 Approval
Start Date
27-Oct-2026

Buy Documents

Draft

ISO/PRF 8178-1 - Reciprocating internal combustion engines — Exhaust emission measurement — Part 1: Test-bed measurement systems of gaseous and particulate emissions

Release Date:27-Oct-2026
English language (172 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/PRF 8178-1 - Reciprocating internal combustion engines — Exhaust emission measurement — Part 1: Test-bed measurement systems of gaseous and particulate emissions

Release Date:27-Oct-2026
English language (172 pages)
sale 15% off
sale 15% off

ISO/PRF 8178-1 is an ISO standard for test-bed measurement systems used to measure gaseous and particulate exhaust emissions from reciprocating internal combustion (RIC) engines. It specifies the methods needed to determine one weighted value for each exhaust gas pollutant, for engines used in mobile, transportable, stationary and marine applications, excluding motor vehicles primarily designed for road use.

What does ISO/PRF 8178-1 specify?

ISO/PRF 8178-1 specifies the measurement methods, test equipment, and verification steps for exhaust-emission testing on an engine test bed. In practice, it tells a laboratory how to sample, measure, calibrate, and check the systems used to report gaseous and particulate emissions from RIC engines.

The standard is organized into clauses for the scope, normative references, terms, symbols, measurement principles, engine and ambient measurement equipment, gaseous components, particulate determination, and calibration and verification. It also includes annexes that support calculations, flow checks, example system layouts, and guidance for non-carbon fuels.

AnnexWhat it covers
Annex CPartial flow dilution checks, including carbon flow and mass flow checks
Annex DStatistical formulas and worked calculation methods such as mean, standard deviation, accuracy, t-test, F-test, regression slope, intercept, standard error, and coefficient of determination
Annex EExamples of partial flow dilution systems
Annex FExamples of exhaust gas analysis systems
Annex GExhaust emission measurement for non-carbon fuelled engines

What are the key requirements of ISO/PRF 8178-1?

The standard ties emissions to the test cycle and the engine application

ISO/PRF 8178-1 requires measurement methods that support one weighted value for each exhaust gas pollutant, using combinations of engine load and speed that represent the engine’s application. That matters because the chosen test points are part of how the final emission result is built, not just a lab setup detail.

Clause 5 also sets the basic measurement approach: continuous sampling, batch sampling, or combined sampling can be used, depending on the measurement system. Clause 5.3.2 and Table 4 define minimum command and recording frequencies for different measured signals, so the data system must capture the right timing for the duty cycle being run.

Sampling and gas conditioning must preserve the exhaust sample

ISO/PRF 8178-1 gives detailed requirements for raw sampling, dilute sampling, transfer tubes, sample-conditioning components, and dilution systems. Clause 5.2 also states that gas drying must not change the sample composition in a significant way, and chemical dryers are not acceptable for removing water from the sample.

This is important in practice because condensation, adsorption, or water loss can shift the measured concentration of CO, HC, NOx, and other gases. The standard therefore controls probe design, heated lines, and dilution arrangements so the sampled gas stays representative of the exhaust leaving the engine.

The test equipment must be suitable for the engine and the test cycle

ISO/PRF 8178-1 requires an engine dynamometer with characteristics adequate for the applicable ISO 8178-4 test cycle and, where applicable, the cycle validation criteria. Clause 6 also covers speed and torque sensors, pressure transducers, temperature sensors, dew point sensors, engine intake-condition sensors, and flow-related measurements.

In practical terms, the lab has to measure power, speed, temperatures, pressures, humidity, and gas flow well enough to support the emission calculations. Clause 6.4 allows engine-installed sensors to be used for intake-air conditions if they are calibrated and meet the stated performance requirements, which can simplify test-bed integration.

Gaseous emissions are measured with defined analyser methods and interference checks

ISO/PRF 8178-1 covers measurement of CO, CO2, O2, HC, NMHC, NOx, SO2, NH3, N2O, HCHO, methanol, ethanol, water, and hydrogen. Clause 7 sets the analyser principles, and Clause 7.4 gives system descriptions for configurations using instruments such as FID, CLD, NDUV, FTIR, LIA, HPLC, PMD, MS, and Raman spectrometer analysers.

This matters because the standard does not just name gases - it also requires the right analyser principle and the right setup for each gas. For example, Clause 7.3.5 gives NMHC measurement options using GC or a non-methane cutter, and Clause 7.3.11 gives alternative methods for methanol and ethanol. The document also defines interference and conversion checks, such as NO-to-NO2 converter verification and quench checks for CLD and NDUV systems, so the analyser response can be trusted during the test.

Particulate matter and particle number need dedicated sampling and dilution systems

ISO/PRF 8178-1 has a separate set of requirements for PM and PN. Clause 8 covers particulate sampling probes, transfer tubes, pre-classifiers, filters, weighing conditions, and particle-number sampling and dilution systems, including full-flow and partial-flow arrangements.

This is the part of the standard that controls how particles are captured, diluted, and counted. For PN testing, the document distinguishes between 10 nm and 23 nm systems, and states that if a standard specifies a 10 nm PN limit, a 10 nm system must be used, while a 10 nm system can also satisfy a 23 nm limit. That choice affects the equipment set, the validation effort, and how the lab demonstrates the result.

Clause 8.4 also covers the volatile particle remover (VPR), particle number counter (PNC), evaporation tube (ET), catalytic stripper (CS), and particle number dilution devices. The VPR requirements matter because they control removal of volatile material without distorting the particle count of the solid fraction.

Calibration and verification are part of the method, not a separate afterthought

ISO/PRF 8178-1 gives a full calibration and verification framework in Clause 9. It includes traceability, accuracy, repeatability, noise, linearity, response-time verification, vacuum-side leak checks, analytical gases, analyser-specific verification, PM balance checks, PNC calibration, VPR validation, CVS full-flow dilution calibration, dynamometer torque calibration, and calibration of temperature, pressure, dew point, and flow-related measurements.

This is what makes the measurements defensible. If the analyser, sampler, dilution system, or balance drifts outside the stated checks, the emission result may not be usable. Clause 9.1.3 summarizes when the various checks are performed, including initial installation, before testing, and after major maintenance.

Annex C supports this by giving partial-flow dilution checks, including carbon-flow and mass-flow validation. Annex D provides the statistical tools used to judge calibration and verification data, so the laboratory can compare measured values, assess spread, and decide whether a system passes.

What terms does ISO/PRF 8178-1 define?

  • Accuracy - the absolute difference between a reference quantity and the arithmetic mean of repeated measurements, used to judge how close an instrument is to the known value.
  • Calibration - the process of adjusting a measurement system so its output agrees with a reference signal over a defined range.
  • Calibration gas - a purified gas mixture used to calibrate gas analysers and check their response.
  • Constant volume sampling (CVS) - a full-flow dilution approach in which the exhaust is diluted and the total diluted flow is measured for emission calculation.
  • Particle number counter (PNC) - the instrument that counts particles in the PN measurement system.
  • Volatile particle remover (VPR) - the device that removes volatile particles or vapours before particle counting so the measured PN reflects the intended particle fraction.
  • Reciprocating internal combustion (RIC) engine - an engine type covered by the standard, used here for mobile, transportable, stationary, and marine applications.

Who uses ISO/PRF 8178-1?

ISO/PRF 8178-1 is used by engine manufacturers, emission test laboratories, calibration laboratories, and conformity assessment teams that work with RIC engines. It is relevant to quality managers and test engineers who need a defined test-bed method for emissions work on engines used in earth-moving machines, generating sets, and similar applications.

It also matters to suppliers of dynamometers, analysers, dilution systems, filters, and sampling equipment, because the document defines how their equipment is integrated and verified in a test system. Buyers use it when they need to specify the measurement method behind an emissions test service or a laboratory setup.

Which standards are used with ISO/PRF 8178-1?

  • ISO 8178-4:2026 - provides the test cycles for different engine applications, and is referenced for the engine duty cycles and related calculation details used with this part.
  • ASTM F1471-93 - provides the test method for air cleaning performance of a high-efficiency particulate air-filter system, which is relevant to the HEPA filters used in PNC calibration and zero checks.

What does the ISO/PRF 8178-1 document contain?

ISO/PRF 8178-1 contains the measurement framework, analyser principles, system requirements, and verification methods needed for exhaust-emission testing on a test bed. It includes tables of symbols and abbreviations, recorded-signal frequency guidance, and detailed clauses on gaseous and particulate measurement.

The document also contains worked calculation and validation material, including formulas for flow checks, analyser response, regression, and statistical evaluation. Annex D gives the calculation methods and critical-value tables used to judge calibration and verification data.

Several figures show typical system layouts and sample paths, including the general measurement system, dilution systems, particle sampling arrangements, and gas-analysis set-ups. Those figures matter because they show how probes, heated lines, filters, analysers, dilution tunnels, pumps, and flow devices fit together in real test benches.

The annexes support practical implementation: Annex C for partial-flow dilution checks, Annex E for example partial-flow systems, Annex F for example exhaust-gas analysis systems, and Annex G for non-carbon fuelled engines. Together, they support design, setup, testing, calibration, and data reduction for emissions work.

Relations

Effective Date
16-Dec-2023

Buy Documents

Draft

ISO/PRF 8178-1 - Reciprocating internal combustion engines — Exhaust emission measurement — Part 1: Test-bed measurement systems of gaseous and particulate emissions

Release Date:27-Oct-2026
English language (172 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/PRF 8178-1 - Reciprocating internal combustion engines — Exhaust emission measurement — Part 1: Test-bed measurement systems of gaseous and particulate emissions

Release Date:27-Oct-2026
English language (172 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

Lloyd's Register

Lloyd's Register is a global professional services organisation specialising in engineering and technology.

UKAS United Kingdom Verified

DNV Energy Systems

Energy and renewable energy certification.

NA Norway Verified

Sponsored listings

Frequently Asked Questions

ISO/PRF 8178-1 is a draft published by the International Organization for Standardization (ISO). Its full title is "Reciprocating internal combustion engines — Exhaust emission measurement — Part 1: Test-bed measurement systems of gaseous and particulate emissions". This standard covers: This document specifies the measurement methods for gaseous and particulate exhaust emissions from reciprocating internal combustion (RIC) engines on a test bed, necessary for determining one weighted value for each exhaust gas pollutant. Various combinations of engine load and speed reflect different engine applications (see ISO 8178‑4). This document is applicable to RIC engines for mobile, transportable and stationary use, excluding engines for motor vehicles primarily designed for road use. This document can be applied to engines used, for example, for earth-moving machines, generating sets and for other applications.

This document specifies the measurement methods for gaseous and particulate exhaust emissions from reciprocating internal combustion (RIC) engines on a test bed, necessary for determining one weighted value for each exhaust gas pollutant. Various combinations of engine load and speed reflect different engine applications (see ISO 8178‑4). This document is applicable to RIC engines for mobile, transportable and stationary use, excluding engines for motor vehicles primarily designed for road use. This document can be applied to engines used, for example, for earth-moving machines, generating sets and for other applications.

ISO/PRF 8178-1 is classified under the following ICS (International Classification for Standards) categories: 13.040.50 - Transport exhaust emissions; 27.020 - Internal combustion engines. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO/PRF 8178-1 has the following relationships with other standards: It is inter standard links to ISO 8178-1:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO/PRF 8178-1 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 accuracy
  • 3.2 aqueous condensation
  • 3.3 atmospheric pressure
  • 3.4 calibration
  • 3.5 calibration gas
  • 3.6 certification
  • 3.7 conversion efficiency of non-methane cutter
  • 3.8 delay time
  • 3.9 dew point
  • 3.10 drift
  • 3.11 exhaust aftertreatment system
  • 3.12 full flow dilution
  • 3.13 good engineering judgement
  • 3.14 HEPA filter
  • 3.15 hydrocarbon
  • 3.16 internationally recognized-traceable standard
  • 3.17 isokinetic sampling
  • 3.18 linearity
  • 3.19 multiple-filter method
  • 3.20 noise
  • 3.21 non-methane hydrocarbons
  • 3.22 operator demand
  • 3.23 oxides of nitrogen
  • 3.24 partial pressure
  • 3.25 partial flow dilution
  • 3.26 particulate matter
  • 3.27 penetration fraction
  • 3.28 probe
  • 3.29 procedures
  • 3.30 ramped-modal test
  • 3.31 regeneration
  • 3.32 repeatability
  • 3.33 response time
  • 3.34 rise time
  • 3.35 single-filter method
  • 3.36 span, verb
  • 3.37 span gas
  • 3.38 span response
  • 3.39 specific emissions
  • 3.40 stand-alone
  • 3.41 steady-state
  • 3.42 stoichiometric
  • 3.43 storage medium
  • 3.44 test cycle
  • 3.45 test interval
  • 3.46 tolerance
  • 3.47 total hydrocarbon
  • 3.48 transformation time
  • 3.49 transient test cycle
  • 3.50 uncertainty
  • 3.51 updating-recording
  • 3.52 verification
  • 3.53 zero, verb
  • 3.54 zero gas
  • 3.55 zero response
  • 4 Symbols and abbreviated terms
  • 4.1 General symbols
  • 4.2 Symbols for fuel composition
  • 4.3 Symbols and abbreviated terms for the chemical components
  • 4.4 Abbreviated terms
  • 5 General measurement principles
  • 5.1 Principle of emission measurement
  • 5.2 Exhaust sampling and dilution
  • 5.3 Measurement instruments
  • 7.4 Speed and torque during an 1 Hz 1 mean value per step
  • 7.4 Speed and torque during an 5 Hz 1 Hz means
  • 8.4 Continuous concentrations N/A 1 Hz
  • 8.4 Continuous concentrations N/A 1 Hz
  • 8.4 Batch concentrations of raw N/A 1 mean value per test
  • 7.4 Diluted exhaust flow rate N/A 1 Hz
  • 7.4 Diluted exhaust flow rate 5 Hz 1 Hz means
  • 7.4 Intake-air , fuel , and raw N/A 1 Hz means
  • 7.4 Dilution air flow if actively 5 Hz 1 Hz means
  • 7.4 Sample flow from a CVS 1 Hz 1 Hz
  • 7.4 Sample flow from a CVS 5 Hz 1 Hz mean
  • 6 Engine and ambient related measurement equipment

Introduction

This document is intended for use as a measurement procedure to determine the gaseous and particulate emission levels of reciprocating internal combustion (RIC) engines for non-road applications. Its purpose is to provide an engine’s emissions characteristics which, through use of proper weighting factors and test cycles, can be used as an indication of that engine’s emission levels under various applications and for different fuels. The emission results are expressed in units of grams per kilowatt-hour and represent the rate of emissions per unit of work accomplished.

Many of the procedures described in this document are detailed accounts of laboratory methods, since determining an emissions value requires performing a complex set of individual measurements, rather than obtaining a single measured value. Thus, the results obtained depend as much on the process of performing the measurements as they depend on the engine and test method. Evaluating emissions from non-road engines is more complicated than the same task for on-road engines due to the diversity of non-road applications. For example, on-road applications primarily consist of moving a load from one point to another on a paved roadway. The constraints of the paved roadways, maximum acceptable pavement loads and maximum allowable grades of fuel, narrow the scope of on-road vehicle and engine sizes. Non-road engines and vehicles include a wider range of size, including the engines that power the equipment. Many of the engines are large enough to preclude the application of test equipment and methods that were acceptable for on-road purposes. In cases where the application of dynamometers is not possible, testing at site or under appropriate conditions can be a viable alternative. In limited instances, the engine can be tested on the test bed in accordance with ISO 8178-2, to test in field conditions. This can only occur with the agreement of the parties involved. Data obtained under these circumstances can differ from previous or future data obtained under the auspices of this document. For engines used in machinery covered by additional requirements (e.g. occupational health and safety regulations, regulations for power plants), additional test conditions and special evaluation methods can apply.

Where it is not possible to use a test bed or where information is required on the actual emissions produced by an in-service engine, the site test procedures and calculation methods specified in ISO 8178-2 are appropriate.

PROOF/ÉPREUVE

International Standard ISO 8178-1:2026(en) Reciprocating internal combustion engines — Exhaust emission measurement — Part 1:

Test-bed measurement systems of gaseous and particulate emissions

1 Scope

This document specifies the measurement methods for gaseous and particulate exhaust emissions from reciprocating internal combustion (RIC) engines on a test bed, necessary for determining one weighted value for each exhaust gas pollutant. Various combinations of engine load and speed reflect different engine applications (see ISO 8178-4).

This document is applicable to RIC engines for mobile, transportable, stationary and marine applications. This document does not apply to engines for motor vehicles primarily designed for road use. This document can be applied to engines used for a range of applications, for example, for earth-moving machines and generating sets.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 8178-4:2026, Reciprocating internal combustion engines — Exhaust emission measurement — Part 4: Test cycles for different engine applications ASTM F1471–93, Standard Test Method for Air Cleaning Performance of a High-Efficiency Particulate Air- Filter System

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 accuracy

absolute difference between the reference quantity, y , and the arithmetic mean of the ten y , y values ref i Note 1 to entry: See the example of an accuracy calculation in Annex D. Note 2 to entry: The instrument accuracy should be within the specifications in 5.3.3.2, Table 5. PROOF/ÉPREUVE

ISO 8178-1:2026(en)

3.2 aqueous condensation

precipitation of water-containing constituents from a gas phase to a liquid phase Note 1 to entry: Aqueous condensation is a function of humidity, pressure, temperature, and concentrations of other constituents such as sulfuric acid. These parameters vary as a function of engine intake-air humidity, dilution-air humidity, engine air-to-fuel ratio, and fuel composition - including the amount of hydrogen and sulfur in the fuel.

3.3 atmospheric pressure

wet, absolute, atmospheric static pressure Note 1 to entry: If the atmospheric pressure is measured in a duct, negligible pressure losses shall be ensured between the atmosphere and the measurement location, and changes in the duct's static pressure resulting from the flow shall be accounted for.

3.4 calibration

process of setting a measurement system's response so that its output agrees with a range of reference signals Note 1 to entry: Contrast with verification (3.52).

3.5 calibration gas

purified gas mixture used to calibrate gas analysers Note 1 to entry: Calibration gases and span gases (3.37) are qualitatively the same, but differ in terms of their primary function. Various performance verification (3.52) checks for gas analysers and sample handling components might refer to either calibration gases or span gases.

Note 2 to entry: The calibration gas shall meet the specifications of 9.2.

3.6 certification

process of obtaining a certificate of conformity

3.7 conversion efficiency of non-methane cutter

conversion efficiency of NMC E efficiency of the conversion of an NMC that is used for the removal of the non-methane hydrocarbons (3.21) from the sample gas by oxidizing all hydrocarbons except methane Note 1 to entry: Ideally, the conversion for methane is 0 % (E = 0) and for the other hydrocarbons represented CH4 by ethane is 100 % (E = 100 %). For the accurate measurement of NMHC (3.21), the two efficiencies shall be C2H6 determined and used for the calculation of the NMHC emission mass flow rate for methane and ethane. Contrast with penetration fraction (3.27).

3.8 delay time

difference in time between the change of the component to be measured at the reference point and a system response of 10 % of the final reading (t ) with the sampling probe (3.28) being defined as the reference

point Note 1 to entry: For the gaseous components, this is the transport time of the measured component from the sampling probe to the detector (see Figure 1).

PROOF/ÉPREUVE

ISO 8178-1:2026(en)

3.9 dew point

measure of humidity stated as the equilibrium temperature at which water condenses under a given pressure from moist air with a given absolute humidity Note 1 to entry: Dew point is specified as a temperature in °C or K, and is valid only for the pressure at which it is measured.

3.10 drift

difference between a zero or calibration (3.4) signal and the respective value reported by a measurement instrument immediately after it was used in an emission test

3.11 exhaust aftertreatment system

catalyst, particulate filter, deNO system, combined deNO particulate filter or any other emission-reducing x x device that is installed downstream of the engine Note 1 to entry: This definition excludes exhaust gas recirculation (EGR) and turbochargers, which are considered an integral part of the engine.

3.12 full flow dilution

method of mixing the exhaust gas flow with dilution air prior to separating a fraction of the diluted exhaust gas flow for analysis

3.13 good engineering judgement

judgement made consistent with generally accepted scientific and engineering principles and available relevant information

3.14 HEPA filter

high-efficiency particulate air filter that is rated to achieve a minimum initial particle-removal efficiency of 99,97 % using ASTM F1471-09, ASTM F1471–93 or an equivalent standard Note 1 to entry: Class H13 in EN 1822-1:2019 is an example of equivalent standard

3.15 hydrocarbon

HC hydrocarbon group on which the applicable emission limit is based for each type of fuel and engine EXAMPLE THC (3.47), NMHC (3.21) as applicable.

3.16 internationally recognized-traceable standard

International Standard which includes, but is not limited to, those in Table 1 PROOF/ÉPREUVE

ISO 8178-1:2026(en) Table 1 — Examples of internationally recognized-traceable standards Internationally recognized Where copies of the documents may be purchased standard American Society for Testing and American Society for Testing and Materials, 100 Barr Harbour Dr., P.O. Box C700, Materials (ASTM) West Conshohocken, PA 19428 or www .astm .com International Organization for International Organization for Standardization, Case Postale 56, Standardization (ISO) CH-1211 Geneva 20, Switzerland or www .iso .org National Institute of Standards Government Printing Office, Washington, DC 20402 or download them free from and Technology (NIST) the Internet at www .nist .gov Society of Automotive Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA Engineering (SAE) 15096 or www .sae .org Institute of Petroleum Energy Institute, 61 New Cavendish Street, London, W1G 7AR, UK, +44 (0)20 7467 7100 or www .energyinst .org .uk The National Metrology AIST Tsukuba Headquarters, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan or Institute of Japan (NMIJ) www .nmij .jp/ english/ info/ Japanese Industrial Standards Japanese Standards Association (JSA), 4-1-12 Akasaka, Minato-ku, 107-8440, (JIS) Japan or www .jsa .org .jp/ default _english .asp

3.17 isokinetic sampling

process of controlling the flow of the exhaust sample by maintaining the mean sample velocity at the probe (3.28) equal to the exhaust stream mean velocity

3.18 linearity

degree to which measured values agree with respective reference values Note 1 to entry: Linearity is quantified using a linear regression of pairs of measured values and reference values over a range of values expected or observed during testing.

3.19 multiple-filter method

process of using one filter for each of the individual test cycle (3.44) modes Note 1 to entry: The modal weighting factors are accounted for after sampling during the data evaluation phase of the test.

3.20 noise

two times the root-mean-square of the ten standard deviations (that is, N = 2 × y ) when the reference RMS(σ) signal is a zero-quantity signal Note 1 to entry: See the example of a root-mean-square calculation in Annex D. The instrument noise should be within the specifications in 5.3.3.2, Table 5.

3.21 non-methane hydrocarbons

NMHC sum of all hydrocarbon (3.15) species except methane

3.22 operator demand

engine operator's input to control engine output Note 1 to entry: The "operator" may be a person (i.e., manual), or a governor (i.e., automatic) that mechanically or electronically signals an input that demands engine output. Input may be from an accelerator pedal or signal, a throttle-control lever or signal, a fuel lever or signal, a speed lever or signal, or a governor setpoint or signal. Output means engine power, P, which is the product of engine speed, n, and engine torque, T. PROOF/ÉPREUVE

ISO 8178-1:2026(en)

3.23 oxides of nitrogen

NO

compounds containing only nitrogen and oxygen as measured by the procedures (3.29) specified in this document Note 1 to entry: Oxides of nitrogen are expressed quantitatively as if the NO is in the form of NO , such that an effective

molar mass is used for all oxides of nitrogen equivalent to that of NO 2.

3.24 partial pressure

pressure, p, attributable to a single gas in a gas mixture Note 1 to entry: For an ideal gas, the partial pressure divided by the total pressure is equal to the constituent's molar concentration, x.

3.25 partial flow dilution

PFD method of analysing the exhaust gas whereby a part of the total exhaust gas flow is separated and then mixed with an appropriate amount of dilution air prior to reaching the particulate sampling filter

3.26 particulate matter

PM material collected on a specified filter medium after diluting exhaust with clean filtered air to a temperature and a point as specified in 8.1.4, primarily carbon, condensed hydrocarbons (3.15), and sulphates with associated water

3.27 penetration fraction

PF deviation from ideal functioning of a non-methane cutter Note 1 to entry: See conversion efficiency of non-methane cutter (NMC), E (3.7). Note 2 to entry: An ideal non-methane cutter would have a methane penetration factor, f , of 1,000 (that is, a PF CH4 methane conversion efficiency E of 0), and the penetration fraction for all other hydrocarbons (3.15) would be 0,000, CH4 as represented by f (that is, an ethane conversion efficiency E of 1). The relationship is: f = 1 – E and PF C2H6 C2H6 PF CH4 CH4 f = 1 – E PF C2H6 C2H6.

3.28 probe

first section of the transfer tube which transfers the sample to next component in the sampling system

3.29 procedures

all aspects of engine testing, including the equipment specifications, calibrations (3.4), calculations and other protocols and specifications needed to measure emissions, unless otherwise specified

3.30 ramped-modal test

test cycle (3.44) with a sequence of steady state engine test modes with defined speed and torque criteria at each mode and defined speed and torque ramps between these modes

3.31 regeneration

event during which emissions levels change while the aftertreatment performance is being restored by design Note 1 to entry: Two types of regeneration can occur: continuous regeneration (see ISO 8178-4:2026, 5.5.1.2.1) and infrequent (periodic) regeneration (see ISO 8178-4:2026, 5.5.1.2.2) ; PROOF/ÉPREUVE

ISO 8178-1:2026(en)

3.32 repeatability

two times the standard deviation of the ten errors, i.e. r = 2σ ε Note 1 to entry: See the example of a standard-deviation calculation in Annex D. The instrument repeatability may be within the specifications shown in Table 5.

3.33 response time

difference in time between the change of the component to be measured at the reference point and a system response of 90 % of the final reading (t ) with the sampling probe (3.28) being defined as the reference

point, whereby the change of the measured component is at least 60 % full scale (FS) and the devices for gas switching shall be specified to perform the gas switching in less than 0,1 s Note 1 to entry: The system response time consists of the delay time (3.8) to the system and of the rise time (3.34) of the system.

3.34 rise time

difference in time of the 10 % and 90 % response of the final reading (t – t ) 90 10

3.35 single-filter method

process of using one filter for all test cycle (3.44) modes Note 1 to entry: Modal weighting factors shall be accounted for during the particulate sampling phase of the test cycle by adjusting sample flow rate and/or sampling time. This method dictates that particular attention be given to sampling duration and flow rates.

3.36 span, verb

adjust an instrument so that it gives a proper response to a calibration (3.4) standard that represents between 75 % and 100 % of the maximum value in the instrument range or expected range of use

3.37 span gas

purified gas mixture used to span (3.36) gas analysers Note 1 to entry: Span gases shall meet the specifications of 9.2. Note that calibration gases (3.5) and span gases are qualitatively the same, but differ in terms of their primary function. Various performance verification (3.52) checks for gas analysers and sample handling components might refer to either calibration gases or span gases.

3.38 span response

mean response, including noise (3.20), to a span gas (3.37) during a 30 s time interval

3.39 specific emissions

mass emissions expressed in g/kWh

3.40 stand-alone

having no dependencies

3.41 steady-state

relating to emission tests in which engine speed and load are held at a finite set of nominally constant values Note 1 to entry: Steady-state tests (3.41) are either discrete-mode tests or ramped-modal tests (3.30). PROOF/ÉPREUVE

ISO 8178-1:2026(en)

3.42 stoichiometric

relating to the particular ratio of air and fuel such that if the fuel were fully oxidized, there would be no remaining fuel or oxygen

3.43 storage medium

particulate filter, sample bag, or any other storage device used for batch sampling

3.44 test cycle

duty cycle sequence of test points each with a defined speed and torque to be followed by the engine under steady state or transient operating conditions Note 1 to entry: Duty cycles are specified in ISO 8178-4:2026, Annexes A to C. A single duty cycle may consist of one or more test intervals (3.45).

3.45 test interval

duration of time over which brake-specific emissions are determined Note 1 to entry: In cases where multiple test intervals occur over a duty cycle (3.44), the regulation can specify additional calculations that weigh and combine results to arrive at composite values for comparison against the applicable emission limits.

3.46 tolerance

interval in which 95 % of a set of recorded values of a certain quantity lies, with the remaining 5 % of the recorded values deviating from the tolerance interval, using the specified recording frequencies and time intervals to determine if a quantity is within the applicable tolerance

3.47 total hydrocarbon

THC combined mass of organic compounds measured by the specified procedure for measuring total hydrocarbon Note 1 to entry: Total hydrocarbon is expressed as a hydrocarbon (3.15) with a hydrogen-to-carbon mass ratio of 1,85 (Diesel), 1,93 (petrol (E10)), 2,525 (LPG), 4,0 (NG/biomethane) or 2,74 (ethanol (E85)). THC is not relevant for pure non-carbon fuels. Small amounts of THC coming from lube oil might be neglected or if required, calculated with a hydrogen-to-carbon ratio of 1,85 (Diesel).

3.48 transformation time

difference in time between the change of the component to be measured at the reference point and a system response of 50 % of the final reading (t ) with the sampling probe (3.28) being defined as the reference

point Note 1 to entry: The transformation time is used for the signal alignment of different measurement instruments (see Figure 1).

3.49 transient test cycle

test cycle (3.44) with a sequence of normalized speed and torque values that vary relatively quickly with time Note 1 to entry: See ISO 8178-4

3.50 uncertainty

of a measurement describes the approximate value by which the actual value differs from the true value. The uncertainty is always positive and without a sign.

PROOF/ÉPREUVE

ISO 8178-1:2026(en)

3.51 updating-recording

frequency at which the analyser provides new, current values

3.52 verification

evaluation of whether or not a measurement system's outputs agree with a range of applied reference signals to within one or more predetermined thresholds for acceptance Note 1 to entry: Contrast with calibration (3.4).

3.53 zero, verb

adjust an instrument, so it gives a zero response (3.54) to a zero calibration (3.4) standard, such as purified nitrogen or purified air

...

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Symbols and abbreviated terms
  • 4.1 General symbols
  • 4.2 Symbols for fuel composition
  • 4.3 Symbols and abbreviated terms for the chemical components
  • 4.4 Abbreviated terms
  • 5 General measurement principles
  • 5.1 Principle of emission measurement
  • 5.2 Exhaust sampling and dilution
  • 5.3 Measurement instruments
  • 7.4 Speed and torque during 1 Hz 1 mean value per step
  • 7.4 Speed and torque during 5 Hz 1 Hz means
  • 8.4 Continuous concentrations N/A 1 Hz
  • 8.4 Continuous concentrations N/A 1 Hz
  • 8.4 Batch concentrations of N/A 1 mean value per test
  • 7.4 Diluted exhaust flow rate N/A 1 Hz
  • 7.4 Diluted exhaust flow rate 5 Hz 1 Hz means
  • 7.4 Intake-air , fuel , and raw N/A 1 Hz means
  • 7.4 Dilution air flow if actively 5 Hz 1 Hz means
  • 7.4 Sample flow from a CVS 1 Hz 1 Hz
  • 7.4 Sample flow from a CVS 5 Hz 1 Hz mean
  • 6 Engine and ambient related measurement equipment
  • 6.1 Dynamometer specification
  • 6.2 Speed and torque sensors
  • 6.3 Pressure transducers, temperature sensors, and dew point sensors
  • 6.4 Engine sensors for air intake conditions
  • 6.5 Flow related measurements
  • 7 Determination of the gaseous components
  • 7.1 General specifications
  • 7.2 Gas drying
  • 7.3 Analysers
  • 7.4 Measurement system
  • 1 HSL
  • 2 HCHO analyzer
  • 8 Particulate determination
  • 8.1 Particulate matter (PM)
  • 8.2 Particle number
  • 8.3 Particulate dilution sampling system equipment
  • 1. Engine
  • 2 Exhaust pipe (EP)
  • 4 Dilution air filter (DAF) and optional charcoal HC filter
  • 8 Dilution Tunnel (DT)
  • 10 Critical Flow Venturi (CFV) with CVS blower
  • 15 CVS Bags for diluted exhaust
  • 16 CVS Bags for dilution air background
  • 8.4 Particle number measurement equipment
  • 1 VPR excess air
  • 5 ET or CS
  • 1 VPR excess air
  • 5 CVS dilution air conditioning, charcoal scrubbed, low- and high-performance filter (HEPA)
  • 6 ET or CS
  • 1 VPR excess air
  • 5 ET or CS
  • 9 Calibration and verification
  • 9.1 Calibration and performance checks
  • 9.2 Analytical gases
  • 9.3 Vacuum-side leak verification
  • 9.4 Calibration, verification and set up of gaseous measurements
  • 4 RF CH4[THC-
  • 2 CO2exp
  • 9.5 Calibration of the particulate mass measuring system
  • 9.6 Calibration of the particle number measuring system
  • 9.7 Calibration of the CVS full flow dilution system
  • 3 PDP
  • 4 CFV
  • 7 SSV
  • 9.8 Calibration of the dynamometer
  • 9.9 Calibration of temperature, pressure and dew point sensors
  • 9.10 Flow-related measurements
  • Annex A
  • Annex B
  • Annex C
  • Annex D
  • Annex E
  • Annex F
  • Annex G
  • 1 Hydrogen

Introduction

This document is intended for use as a measurement procedure to determine the gaseous and particulate emission levels of reciprocating internal combustion (RIC) engines for non-road applications. Its purpose is to provide an engine’s emissions characteristics which, through use of proper weighting factors and test cycles, can be used as an indication of that engine’s emission levels under various applications and for different fuels. The emission results are expressed in units of grams per kilowatt-hour and represent the rate of emissions per unit of work accomplished.

Many of the procedures described in this document are detailed accounts of laboratory methods, since determining an emissions value requires performing a complex set of individual measurements, rather than obtaining a single measured value. Thus, the results obtained depend as much on the process of performing the measurements as they depend on the engine and test method. Evaluating emissions from non-road engines is more complicated than the same task for on-road engines due to the diversity of non-road applications. For example, on-road applications primarily consist of moving a load from one point to another on a paved roadway. The constraints of the paved roadways, maximum acceptable pavement loads and maximum allowable grades of fuel, narrow the scope of on-road vehicle and engine sizes. Non-road engines and vehicles include a wider range of size, including the engines that power the equipment. Many of the engines are large enough to preclude the application of test equipment and methods that were acceptable for on-road purposes. In cases where the application of dynamometers is not possible, testing at site or under appropriate conditions can be a viable alternative. In limited instances, the engine can be tested on the test bed in accordance with ISO 8178--2, to test in field conditions. This can only occur with the agreement of the parties involved. Data obtained under these circumstances can differ from previous or future data obtained under the auspices of this document. For engines used in machinery covered by additional requirements (e.g. occupational health and safety regulations, regulations for power plants), additional test conditions and special evaluation methods can apply.

Where it is not possible to use a test bed or where information is required on the actual emissions produced by an in-service engine, the site test procedures and calculation methods specified in ISO 8178--2 are appropriate.

DRAFT International Standard ISO/DIS 8178-1:2026(en)

Reciprocating internal combustion engines — Exhaust emission measurement — Part 1:

Test-bed measurement systems of gaseous and particulate emissions

1 Scope

This document specifies the measurement methods for gaseous and particulate exhaust emissions from reciprocating internal combustion (RIC) engines on a test bed, necessary for determining one weighted value for each exhaust gas pollutant. Various combinations of engine load and speed reflect different engine applications (see ISO 8178--4).

This document is applicable to RIC engines for mobile, transportable, stationary and marine applications. This document does not apply to engines for motor vehicles primarily designed for road use. This document can be applied to engines used for a range of applications, for example, for earth-moving machines and generating sets.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 8178--4:2026, Reciprocating internal combustion engines — Exhaust emission measurement — Part 4: Test cycles for different engine applications ASTM F1471–93, Standard Test Method for Air Cleaning Performance of a High-Efficiency Particulate Air- Filter System

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • — ISO Online browsing platform: available at https://www.iso.org/obphttps://www.iso.org/obp
  • — IEC Electropedia: available at https://www.electropedia.org/https://www.electropedia.org/

3.1 3.1 accuracy absolute difference between the reference quantity, y , and the arithmetic mean of the ten y , y values ref i Note 1 to entry: See the example of an accuracy calculation in Annex D.Annex D. Note 2 to entry: The instrument accuracy should be within the specifications in 5.3.3.2, Table 5.5.3.3.2, Table 5 .

ISO/PRF 8178-1:2026(en) 3.2 3.2 aqueous condensation precipitation of water-containing constituents from a gas phase to a liquid phase Note 1 to entry: Aqueous condensation is a function of humidity, pressure, temperature, and concentrations of other constituents such as sulfuric acid. These parameters vary as a function of engine intake-air humidity, dilution-air humidity, engine air-to-fuel ratio, and fuel composition - including the amount of hydrogen and sulfur in the fuel. 3.3 3.3 atmospheric pressure wet, absolute, atmospheric static pressure Note 1 to entry: If the atmospheric pressure is measured in a duct, negligible pressure losses shall be ensured between the atmosphere and the measurement location, and changes in the duct's static pressure resulting from the flow shall be accounted for.

3.4 3.4 calibration process of setting a measurement system's response so that its output agrees with a range of reference signals Note 1 to entry: Contrast with verification (3.52).(3.52).

3.5 3.5 calibration gas purified gas mixture used to calibrate gas analysers Note 1 to entry: Calibration gases and span gases (3.37)(3.37) are qualitatively the same, but differ in terms of their primary function. Various performance verification (3.52)(3.52) checks for gas analysers and sample handling components might refer to either calibration gases or span gases. Note 1 2 to entry: The calibration gas shall meet the specifications of 9.2.9.2. 3.6 3.6 certification process of obtaining a certificate of conformity 3.7 3.7 conversion efficiency of non-methane cutter conversion efficiency of NMC E efficiency of the conversion of an NMC that is used for the removal of the non-methane hydrocarbons (3.21)(3.21) from the sample gas by oxidizing all hydrocarbons except methane Note 1 to entry: Ideally, the conversion for methane is 0 % (E = 0) and for the other hydrocarbons represented by CH4 ethane is 100 % (E = 100 %). For the accurate measurement of NMHC (3.21),(3.21), the two efficiencies shall be C2H6 determined and used for the calculation of the NMHC emission mass flow rate for methane and ethane. Contrast with penetration fraction (3.27).(3.27).

3.8 3.8 delay time difference in time between the change of the component to be measured at the reference point and a system response of 10 % of the final reading (t ) with the sampling probe (3.28)(3.28) being defined as the reference

point

ISO/DISPRF 8178-1:2026(en) Note 1 to entry: For the gaseous components, this is the transport time of the measured component from the sampling probe to the detector (see Figure 1).Figure 1 ).

3.9 3.9 dew point measure of humidity stated as the equilibrium temperature at which water condenses under a given pressure from moist air with a given absolute humidity Note 1 to entry: Dew point is specified as a temperature in °C or K, and is valid only for the pressure at which it is measured.

3.10 3.10 drift difference between a zero or calibration (3.4)(3.4) signal and the respective value reported by a measurement instrument immediately after it was used in an emission test 3.11 3.11 exhaust aftertreatment system catalyst, particulate filter, deNO system, combined deNO particulate filter or any other emission-reducing x x device that is installed downstream of the engine Note 1 to entry: This definition excludes exhaust gas recirculation (EGR) and turbochargers, which are considered an integral part of the engine.

3.12 3.12 full flow dilution method of mixing the exhaust gas flow with dilution air prior to separating a fraction of the diluted exhaust gas flow for analysis 3.13 3.13 good engineering judgement judgement made consistent with generally accepted scientific and engineering principles and available relevant information 3.14 3.14 HEPA filter high-efficiency particulate air filter that is rated to achieve a minimum initial particle-removal efficiency of 99,97 % using ASTM F1471-09, ASTM F1471–93 or an equivalent standard. Note 1 to entry : Class H13 in EN 1822-1:2019 is an example of equivalent standard 3.15 3.15 hydrocarbon HC hydrocarbon group on which the applicable emission limit is based for each type of fuel and engine EXAMPLE THC (3.47),(3.47), NMHC (3.21)(3.21) as applicable.

3.16 3.16 internationally recognized-traceable standard International Standard which includes, but is not limited to the list quoted, those in Table 1Table 1

ISO/PRF 8178-1:2026(en) Note 1 to entry: InternationallyTable 1 — Examples of internationally recognized-traceable standard is listed in Table 1, but is not limited to the ones in Table 1standards Table 1 — Internationally recognized-traceable standard Internationally recognized Where copies of the documents may be purchased standard American Society for Testing American Society for Testing and Materials, 100 Barr Harbour Dr., P.O. Box C700, and Materials (ASTM) West Conshohocken, PA 19428 or www.astm.comwww.astm.com International Organization for International Organization for Standardization, Case Postale 56, Standardization (ISO) CH-1211 Geneva 20, Switzerland or www.iso.orgwww.iso.org National Institute of Standards Government Printing Office, Washington, DC 20402 or download them free from and Technology (NIST) the Internet at www.nist.govwww.nist.gov Society of Automotive Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA Engineering (SAE) 15096 or www.sae.orgwww.sae.org Institute of Petroleum Energy Institute, 61 New Cavendish Street, London, W1G 7AR, UK, +44 (0)20 7467 7100 or www.energyinst.org.ukwww.energyinst.org.uk The National Metrology AIST Tsukuba Headquarters, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan Institute of Japan (NMIJ) or www.nmij.jp/english/info/www.nmij.jp/english/info/ Japanese Industrial Standards Japanese Standards Association (JSA), 4-1-12 Akasaka, Minato-ku, 107-8440, (JIS) Japan or www.jsa.org.jp/default_english.aspwww.jsa.org.jp/default_english.asp

3.17 3.17 isokinetic sampling process of controlling the flow of the exhaust sample by maintaining the mean sample velocity at the probe (3.28)(3.28) equal to the exhaust stream mean velocity 3.18 3.18 linearity degree to which measured values agree with respective reference values Note 1 to entry: Linearity is quantified using a linear regression of pairs of measured values and reference values over a range of values expected or observed during testing.

3.19 3.19 multiple-filter method process of using one filter for each of the individual test cycle (3.44)(3.44) modes Note 1 to entry: The modal weighting factors are accounted for after sampling during the data evaluation phase of the test.

3.20 3.20 noise two times the root-mean-square of the ten standard deviations (that is, N = 2 × y ) when the reference RMS(σ) signal is a zero-quantity signal Note 1 to entry: See the example of a root-mean-square calculation in Annex D.Annex D. The instrument noise should be within the specifications in 5.3.3.2, Table 5.5.3.3.2, Table 5 .

ISO/DISPRF 8178-1:2026(en) 3.21 3.21 non-methane hydrocarbons NMHC sum of all hydrocarbon (3.15)(3.15) species except methane 3.22 3.22 operator demand engine operator's input to control engine output Note 1 to entry: The "operator" may be a person (i.e., manual), or a governor (i.e., automatic) that mechanically or electronically signals an input that demands engine output. Input may be from an accelerator pedal or signal, a throttlecontrol lever or signal, a fuel lever or signal, a speed lever or signal, or a governor setpoint or signal. Output means engine power, P, which is the product of engine speed, n, and engine torque, T. 3.23 3.23 oxides of nitrogen NO

compounds containing only nitrogen and oxygen as measured by the procedures (3.29)(3.29) specified in this document Note 1 to entry: Oxides of nitrogen are expressed quantitatively as if the NO is in the form of NO , such that an effective

molar mass is used for all oxides of nitrogen equivalent to that of NO 2.

3.24 3.24 partial pressure pressure, p, attributable to a single gas in a gas mixture Note 1 to entry: For an ideal gas, the partial pressure divided by the total pressure is equal to the constituent's molar concentration, x.

3.25 3.25 partial flow dilution PFD method of analysing the exhaust gas whereby a part of the total exhaust gas flow is separated and then mixed with an appropriate amount of dilution air prior to reaching the particulate sampling filter 3.26 3.26 particulate matter PM material collected on a specified filter medium after diluting exhaust with clean filtered air to a temperature and a point as specified in 8.1.4,8.1.4, primarily carbon, condensed hydrocarbons (3.15),(3.15), and sulphates with associated water 3.27 3.27 penetration fraction PF deviation from ideal functioning of a non-methane cutter Note 1 to entry: See conversion efficiency of non-methane cutter (NMC), E (3.7).(3.7). Note 2 to entry: An ideal non-methane cutter would have a methane penetration factor, fPF CH4, of 1,000 (that is, a methane conversion efficiency E of 0), and the penetration fraction for all other hydrocarbons (3.15)(3.15) would be CH4 0,000, as represented by f (that is, an ethane conversion efficiency E of 1). The relationship is: f = 1 – E PF C2H6 C2H6 PF CH4 CH4 and fPF C2H6 = 1 – EC2H6.

ISO/PRF 8178-1:2026(en) 3.28 3.28 probe first section of the transfer tube which transfers the sample to next component in the sampling system 3.29 3.29 procedures all aspects of engine testing, including the equipment specifications, calibrations (3.4),(3.4), calculations and other protocols and specifications needed to measure emissions, unless otherwise specified 3.30 3.30 ramped-modal test test cycle (3.44)(3.44) with a sequence of steady state engine test modes with defined speed and torque criteria at each mode and defined speed and torque ramps between these modes 3.31 3.31 regeneration event during which emissions levels change while the aftertreatment performance is being restored by design Note 1 to entry: Two types of regeneration can occur: continuous regeneration (see ISO 8178-4:2026, 5.5.1.2.1) and infrequent (periodic) regeneration (see ISO 8178-4:2026, 5.5.1.2.2);) ; 3.32 3.32 repeatability two times the standard deviation of the ten errors, i.e. r = 2σ ε Note 1 to entry: See the example of a standard-deviation calculation in Annex D.Annex D. The instrument repeatability may be within the specifications shown in Table 5.Table 5 .

3.33 3.33 response time difference in time between the change of the component to be measured at the reference point and a system response of 90 % of the final reading (t ) with the sampling probe (3.28)(3.28) being defined as the reference

point, whereby the change of the measured component is at least 60 % full scale (FS) and the devices for gas switching shall be specified to perform the gas switching in less than 0,1 s Note 1 to entry: The system response time consists of the delay time (3.8)(3.8) to the system and of the rise time (3.34)(3.34) of the system.

3.34 3.34 rise time difference in time of the 10 % and 90 % response of the final reading (t – t ) 90 10 3.35 3.35 single-filter method process of using one filter for all test cycle (3.44)(3.44) modes Note 1 to entry: Modal weighting factors shall be accounted for during the particulate sampling phase of the test cycle by adjusting sample flow rate and/or sampling time. This method dictates that particular attention be given to sampling duration and flow rates.

ISO/DISPRF 8178-1:2026(en) 3.36 3.36 span, verb adjust an instrument so that it gives a proper response to a calibration (3.4)(3.4) standard that represents between 75 % and 100 % of the maximum value in the instrument range or expected range of use 3.37 3.37 span gas purified gas mixture used to span (3.36)(3.36) gas analysers Note 1 to entry: Span gases shall meet the specifications of 9.2.9.2. Note that calibration gases (3.5)(3.5) and span gases are qualitatively the same, but differ in terms of their primary function. Various performance verification (3.52)(3.52) checks for gas analysers and sample handling components might refer to either calibration gases or span gases. 3.38 3.38 span response mean response, including noise (3.20),(3.20), to a span gas (3.37)(3.37) during a 30 s time interval 3.39 3.39 specific emissions mass emissions expressed in g/kWh 3.40 3.40 stand-alone having no dependencies 3.41 3.41 steady-state relating to emission tests in which engine speed and load are held at a finite set of nominally constant values Note 1 to entry: Steady-state tests (3.41)(3.41) are either discrete-mode tests or ramped-modal tests (3.30).(3.30). 3.42 3.42 stoichiometric relating to the particular ratio of air and fuel such that if the fuel were fully oxidized, there would be no remaining fuel or oxygen 3.43 3.43 storage medium particulate filter, sample bag, or any other storage device used for batch sampling 3.44 3.44 test cycle duty cycle sequence of test points each with a defined speed and torque to be followed by the engine under steady state or transient operating conditions Note 1 to entry: Duty cycles are specified in ISO 8178-4:2026, Annexes A to C. A single duty cycle may consist of one or more test intervals (3.45).(3.45).

3.45 3.45 test interval duration of time over which brake-specific emissions are determined Note 1 to entry: In cases where multiple test intervals occur over a duty cycle (3.44),(3.44), the regulation can specify additional calculations that weigh and combine results to arrive at composite values for comparison against the applicable emission limits.

ISO/PRF 8178-1:2026(en) 3.46 3.46 tolerance interval in which 95 % of a set of recorded values of a certain quantity lies, with the remaining 5 % of the recorded values deviating from the tolerance interval, using the specified recording frequencies and time intervals to determine if a quantity is within the applicable tolerance 3.47 3.47 total hydrocarbon THC combined mass of organic compounds measured by the specified procedure for measuring total hydrocarbon Note 1 to entry: Total hydrocarbon is expressed as a hydrocarbon (3.15)(3.15) with a hydrogen-to-carbon mass ratio of 1,85 (Diesel), 1,93 (petrol (E10)), 2,525 (LPG), 4,0 (NG/biomethane) or 2,74 (ethanol (E85)). THC is not relevant for pure non-carbon fuels. Small amounts of THC coming from lube oil might be neglected or if required, calculated with a hydrogen-to-carbon ratio of 1,85 (Diesel).

3.48 3.48 transformation time difference in time between the change of the component to be measured at the reference point and a system response of 50 % of the final reading (t ) with the sampling probe (3.28)(3.28) being defined as the reference

point Note 1 to entry: The transformation time is used for the signal alignment of different measurement instruments (see Figure 1).Figure 1 ).

3.49 3.49 transient test cycle test cycle (3.44)(3.44) with a sequence of normalized speed and torque values that vary relatively quickly with time Note 1 to entry: See ISO 8178--4 3.50 3.50 uncertainty of a measurement describes the approximate value by which the actual value differs from the true value. The uncertainty is always positive and without a sign.

...