ISO/DTR 25582 - Influences of the velocity and temperature distribution on fluid flow measurement by using Pitot static tubes

Release Date:21-Sep-2026
English language (42 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/DTR 25582 - Influences of the velocity and temperature distribution on fluid flow measurement by using Pitot static tubes

Release Date:21-Sep-2026
English language (42 pages)
sale 15% off
sale 15% off

ISO/DTR 25582 is an ISO technical report on how velocity distribution, temperature distribution and humidity influence fluid flow measurement with Pitot static tubes in closed conduits. It gives data and references for engineers working on large industrial flow measurements, especially where long straight runs upstream and downstream of the measuring section are hard to achieve. The document shows how conduit length, flow-conditioning devices and moist-air density calculations can change the result.

What does ISO/DTR 25582 specify?

ISO/DTR 25582 provides guidance data and references for measuring fluid flow in closed conduits with Pitot static tubes in complex industrial situations. It focuses on four common influences on the measurement - conduit length, velocity distribution, temperature distribution and humidity.

The document is organized into clauses 1 to 8, followed by a bibliography. Clause 1 states the scope, clause 2 lists normative references, clause 3 points to the terms and definitions from ISO 3966:2025, clause 4 gives symbols, clause 5 covers upstream and downstream conduit length, clause 6 covers velocity and temperature distribution uniformity, clause 7 covers devices for improving flow conditions, and clause 8 covers humidity.

What are the key requirements of ISO/DTR 25582?

ISO/DTR 25582 is a guidance document rather than a test standard, so its most useful points are the measurement conditions and evaluation criteria it illustrates. In practice, it helps you judge whether a Pitot static tube measurement section is suitable, and what to do when it is not.

Straight runs upstream and downstream matter

Clause 5 shows that enough straight conduit is needed before and after the measuring section to reduce asymmetry, swirl and turbulence. It recalls the ISO 3966 guidance on long upstream and downstream lengths and then illustrates the effect with test and simulation results.

For a circular conduit, the document shows that a long upstream and downstream run can keep the velocity profile reasonably symmetric, while a shorter upstream run gives much poorer results. For a rectangular conduit, the example with long straight lengths gives a more uniform profile and a calculated flow rate close to the reference value. In practice, this means the measuring cross-section should be placed away from elbows, reducers and other disturbances whenever possible.

Velocity profile uniformity is a practical acceptance check

Clause 5 and clause 6 use the relative standard deviation of the velocity distribution as a practical measure of uniformity. The document treats a velocity distribution with a relative standard deviation of 15 percent or less as acceptable guidance.

Clause 5 also uses the index of asymmetry of the flow (Y) for circular ducts, based on ISO 7194. The examples show that a lower Y corresponds to a more usable profile for Pitot static tube measurement. In practice, these measures tell you whether the cross-section is stable enough for velocity-area calculations.

Temperature uniformity matters when the fluid is not well mixed

Clause 6 explains that in real ducts the straight run may be too short for temperature and velocity to mix fully. The document therefore examines how uneven temperature distribution affects flow measurement with Pitot static tubes.

For guidance, the document treats temperature distribution as acceptable when the temperature deviation remains below 5 percent in the stated temperature range of 273 K to 623 K. The examples show that uneven temperature can shift the calculated flow rate noticeably, even when the velocity field is unchanged. In practice, this means temperature mixing must be checked whenever mass flow is being derived from measured velocity.

Flow-conditioning devices can improve the measuring section

Clause 7 reviews several devices used to improve flow conditions.

  • Turning vanes smooth the flow direction near elbows and can greatly reduce velocity non-uniformity.
  • A profile developer, such as screens, grids or perforated plates, can reduce irregular velocity profiles.
  • A static mixer can divide and redistribute streams with different temperatures, but it increases head loss.
  • Multiple devices can be combined when the duct layout is especially complex.

The examples show large improvements in velocity and temperature uniformity after these devices are installed. In practice, these devices are used when a better measuring location cannot be created by duct layout alone.

Humidity affects density in compressible-flow calculations

Clause 8 compares two density formulas for compressible fluid, including the CIPM-2007 formula that takes humidity into account. The document shows that for moist air the density difference between a dry-air calculation and a humidity-aware calculation is small in the example cases, but still relevant to mass-flow work.

The examples use relative humidity (hr) and show how it enters the density calculation. In practice, if the flow result is converted from velocity to mass flow, humidity should be considered for moist air because density drives the final value.

What terms does ISO/DTR 25582 define?

ISO/DTR 25582 uses the terms and definitions from ISO 3966:2025, and its symbols section adds the notation used in the examples.

  • Pitot static tubes - Instruments that use total and static pressure to determine local fluid velocity in a closed conduit.
  • Velocity-area method - A flow measurement method that calculates flow from velocities measured over a cross-section.
  • Relative humidity (hr) - The water-vapour content used in the humidity discussion and in moist-air density calculations.
  • Index of asymmetry of the flow (Y) - A measure used to describe how asymmetric the velocity profile is in circular ducts.
  • Profile developer - A device such as a screen, grid or perforated plate used to improve velocity uniformity.
  • Static mixer - An insert-type device that divides and redistributes streams to improve mixing of fluids at different temperatures.
  • Turning vanes - Arc or flat plates used near elbows to smooth flow direction and reduce swirl.

Who uses ISO/DTR 25582?

ISO/DTR 25582 is used by people who measure airflow in closed conduits with Pitot static tubes. That includes flow-measurement engineers, HVAC and ventilation specialists, and instrumentation teams in large industrial plants.

It is also useful for quality managers, commissioning teams and buyers who need to judge whether a duct layout is suitable for flow measurement, or whether flow-conditioning devices are needed. The document’s examples come from industrial ducts and a thermal power plant, so it is especially relevant where duct geometry, elbows and mixed-temperature air streams affect measurement accuracy.

Which standards are used with ISO/DTR 25582?

ISO/DTR 25582 relies on ISO 3966:2025 for the core Pitot static tube method, the terms and definitions, the symbols, and the measuring-point arrangements used in its examples. It also uses the ISO 3966 guidance on straight runs and the log-Chebyshev point layout shown in the document.

  • ISO 3966:2025 - Supplies the velocity-area method using Pitot static tubes, the measuring-point rules and the basic flow-measurement framework.
  • ISO 7194 - Provides the asymmetry index (Y) used to judge swirling or asymmetric flow in circular ducts.
  • ISO 5167-2 - Gives a related pressure-differential flow-measurement reference for orifice plates in circular conduits.
  • ISO 5167-3 - Gives a related pressure-differential flow-measurement reference for nozzles and Venturi nozzles.
  • ISO 5801 - Provides performance testing for fans using standardized airways, which is relevant background for air-handling systems.
  • EN 12599:2012 - Appears in the examples as a comparison for measuring-point selection and irregularity in ventilation systems.

What does the ISO/DTR 25582 document contain?

ISO/DTR 25582 contains experimental and numerical studies rather than a single prescriptive test method. It includes a circular-conduit test bench, point-by-point velocity measurements, and figures showing velocity profiles and contours.

It also contains numerical simulations for circular and rectangular ducts, including grid-point statistics and a log-Chebyshev point arrangement. The document uses these to compare good and poor measuring locations, and to show the effect of turning vanes, profile developers, static mixers and multiple devices.

Later clauses include worked examples for moist-air density and the impact of humidity on calculated flow. A cold-state fireworks tracer test is also described to show how combined devices reorganize the flow path in a mixed air duct.

Buy Documents

Draft

ISO/DTR 25582 - Influences of the velocity and temperature distribution on fluid flow measurement by using Pitot static tubes

Release Date:21-Sep-2026
English language (42 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/DTR 25582 - Influences of the velocity and temperature distribution on fluid flow measurement by using Pitot static tubes

Release Date:21-Sep-2026
English language (42 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

BSMI (Bureau of Standards, Metrology and Inspection)

Taiwan's standards and inspection authority.

TAF Taiwan Verified

Sponsored listings

Frequently Asked Questions

ISO/DTR 25582 is a draft published by the International Organization for Standardization (ISO). Its full title is "Influences of the velocity and temperature distribution on fluid flow measurement by using Pitot static tubes". This standard covers: Influences of the velocity and temperature distribution on fluid flow measurement by using Pitot static tubes

Influences of the velocity and temperature distribution on fluid flow measurement by using Pitot static tubes

ISO/DTR 25582 is classified under the following ICS (International Classification for Standards) categories: 17.120.10 - Flow in closed conduits. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO/DTR 25582 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Symbols
  • 5 Influence of length of upstream/downstream conduit
  • 5.1 General
  • 5.2 Circular cross-sections
  • 5.3 Rectangular cross-sections
  • 6 Influence of velocity and temperature distribution uniformity
  • 6.1 General
  • 6.2 Velocity distribution uniformity
  • 6.3 Influence of temperature distribution uniformity
  • 7 Influence of devices for improving flow conditions
  • 7.1 General
  • 7.2 Turning vanes
  • 7.3 Profile developer
  • 7.4 Static mixer
  • 7.5 Multiple devices
  • 8 Influence of humidity
  • Bibliography

1 Scope

This document provides data and references to better guide measurement of fluid flow in closed conduits with Pitot static tubes in many complex scenarios of large industrial applications. This document illustrates influences of the following common conditions on fluid flow measurement by using Pitot static tubes:

a) influence of length of upstream/downstream conduit; b) influence of velocity and temperature distribution uniformity; c) influence of devices for improving flow conditions; d) influence of humidity.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3966, Measurement of fluid flow in closed conduits — Velocity area method using Pitot static tubes

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 3966 apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

4 Symbols

The symbols given in ISO 3966 and the following symbols apply. Symbol Quantity Dimensions SI unit h relative humidity of fluid — — r Y the index of asymmetry of the flow — —

5 Influence of length of upstream/downstream conduit

5.1 General

ISO 3966 provides guidance on the use of Pitot tubes. According to ISO 3966,it is normally assumed that to comply with these conditions there is a length of upstream conduit between the beginning of the working

ISO/DTR 25582:2026(en) section and any significant upstream irregularity of at least 20 diameters of a circular cross-section (or 80 times the hydraulic radius of a conduit of any cross-section shape). ISO 3966 also recommends that there be at least 5 diameters of a circular cross-section (or 20 times the hydraulic radius of a conduit of any crosssection shape), between the measuring cross-section and any significant downstream irregularity to avoid asymmetry, swirl and turbulences.

5.2 Circular cross-sections

5.2.1 Experimental test

A test bench with circular conduit in laboratory is shown in Figure 1. The measuring cross-section is located at the long horizontal circular conduit of the test bench. The cross-sectional inner dimension of the circular conduit is 0,6 m. The lengths of the upstream and downstream straight conduit of the measuring crosssection are 13,0 m and 6,5 m, respectively. Dimensions in metres a) Photograph of long horizontal conduit section with measuring cross-section b) Photograph of measuring cross-section and holes

ISO/DTR 25582:2026(en) c) 3D model diagram Key 1 elbow conduit 2 comparative cross section 3 test measuring cross-section 4 straight conduit a Measurement hole in vertical direction.

b Measurement hole in horizontal direction.

Flow direction.

Figure 1 — Test bench with circular conduit in laboratory In this document, the influence of length of upstream/downstream circular conduit on velocity profile by using Pitot tubes is demonstrated through the experimental test in laboratory and numerical simulation. At the measuring cross-section of the test bench, to obtain the velocity distribution, the horizontal and vertical directions are selected and there are 29 measuring points per direction (see Figure 2). The selection of these measuring points is uniformly distributed along the centrelines of the measurement cross-section and does not comply with the velocity-area method. Therefore, the obtained measurement velocity data are only for reference in researching the flow velocity distribution.

ISO/DTR 25582:2026(en) Dimensions in millimetres Key X horizontal direction Y vertical direction Figure 2 — Measuring points at the measuring cross-section for velocity distribution In the test, the medium is air. The relative humidity, pressure and density of the air are shown in Table 1, which also gives the measurement data of the velocity at the measuring cross section. The fluid velocities are measured by using Pitot tubes and calculated from the differential pressure existing between the total and static pressures of the Pitot tube placed at these measuring points. Table 1 — Measurement data at the measuring cross-section for velocity distribution Horizontal direction Vertical direction Relative humid- Relative hu- Temperature Pressure Density Temperature Pressure Density ity midity 3 3 °C kPa kg/m °C kPa kg/m

20,5 65 101,8 1,201 18,4 65 102,0 1,213 Measuring Differential Measuring Differential Local velocity Local velocity points radius pressure points radius pressure m/s m/s mm Pa mm Pa -280 100,279 12,92 -280 106,094 13,23 -260 124,127 14,38 -260 129,280 14,60 -240 134,535 14,97 -240 144,919 15,46 -220 143,086 15,44 -220 156,500 16,06 -200 155,236 16,08 -200 164,406 16,46

ISO/DTR 25582:2026(en) TTaabblle 1 e 1 ((ccoonnttiinnueuedd)) Horizontal direction Vertical direction Relative humid- Relative hu- Temperature Pressure Density Temperature Pressure Density ity midity 3 3 °C kPa kg/m °C kPa kg/m

20,5 65 101,8 1,201 18,4 65 102,0 1,213 Measuring Differential Measuring Differential Local velocity Local velocity points radius pressure points radius pressure m/s m/s mm Pa mm Pa -180 162,356 16,44 -180 171,064 16,79 -160 165,216 16,59 -160 175,698 17,02 -140 172,492 16,95 -140 177,694 17,12 -120 170,939 16,87 -120 182,499 17,35 -100 173,894 17,02 -100 180,745 17,26 -80 174,915 17,07 -80 184,611 17,45 -60 175,860 17,11 -60 184,307 17,43 -40 176,229 17,13 -40 183,821 17,41 -20 174,923 17,07 -20 184,234 17,43 0 174,796 17,06 0 186,085 17,52 20 173,684 17,01 20 184,692 17,45 40 174,463 17,04 40 185,482 17,49 60 173,712 17,01 60 184,367 17,44 80 171,655 16,91 80 181,787 17,31 100 172,366 16,94 100 182,160 17,33 120 169,259 16,79 120 180,632 17,26 140 163,205 16,49 140 175,065 16,99 160 158,207 16,23 160 168,248 16,66 180 147,744 15,69 180 165,612 16,52 200 137,603 15,14 200 154,296 15,95 220 128,610 14,63 220 142,291 15,32 240 114,932 13,83 240 134,029 14,87 260 93,164 12,46 260 115,936 13,83 280 88,966 12,17 280 104,355 13,12 Figure 3 shows the velocity distributions at horizontal and vertical diameters. Obviously, the velocity distribution exhibits relatively good central symmetry in both horizontal and vertical directions.

ISO/DTR 25582:2026(en) a) Horizontal direction b) Vertical direction Key r radius of the position where the measuring points are located in the horizontal direction h v measured velocity at the position where the measuring points are located in the horizontal direction h r radius of the position where the measuring points are located in the vertical direction

ISO/DTR 25582:2026(en) v measured velocity at the position where the measuring points are located in the vertical direction

Figure 3 — Measuring velocity distributions at horizontal and vertical diameters Figure 4 gives positions of the measuring points respectively according to regulations (velocity-area [5] method) of ISO 3966 and EN 12599 .

a) According to ISO 3966 b) According to EN 12599 Key X horizontal direction Y vertical direction Figure 4 — Measuring points at the measuring cross-section for velocity measurement Table 2 shows the measuring point statistical results of the flow field at the measuring cross section according to ISO 3966 and EN 12599. The test results indicate that, as the measuring cross-section is far enough away from any disturbances, the relative standard deviation of the velocity distribution at the cross section is maintained at the level which is no more than 15 %. It is normally assumed that the uniformity of velocity distribution is acceptable with σ ≤ 15 %.

ISO/DTR 25582:2026(en) Table 2 — Measurement data at the measuring cross-section for velocity measurement Measur- Local velocity Relative standard devi- Average velocity at the ing points ation of the velocity distri- m/s cross section radius bution at the cross section m/s Horizontal direction Vertical direction mm % Refer to ISO 3966:2025 -289 11,67 12,05 -254 13,95 14,66 -207 15,74 16,32 -171 16,44 16,85 -86 16,98 17,29 15,04 13,48 86 17,00 17,41 171 16,00 16,62 207 15,05 15,89 254 13,19 14,21 289 11,34 12,07 Refer to EN 12599:2012 -285 11,98 12,44 -251 14,10 14,82 -212 15,60 16,21 -164 16,53 16,92 -95 16,96 17,26 15,11 12,63 95 16,96 17,37 164 16,15 16,73 212 14,89 15,75 251 13,33 14,35 285 11,57 12,37 Besides, two indexes are considered to characterize the symmetry of the velocity distribution:

a) According to ISO 7194, for circular ducts, the index of asymmetry of the flow (Y) is defined to evaluate the asymmetric flow conditions and is not advisable to be greater than 0,15 to make a measurement. The index of asymmetry of the flow (Y) can be calculated by the following Formula (1):

12/ n

uv

 i i1

Y  (1) v n1

where n is the number of radii traversed (4, 6 or 8); u is the mean velocity calculated from the individual point velocity measurements at i radius,

m/s; v is the mean axial velocity calculated from all of the individual point velocity measurements, m/s.

b) According to EN 12599, for rectangular ducts and circular ducts, the following formula is used as a measure of the irregularity, Irr, of the velocity profile and can be calculated by the following Formula (2). In the case of a rectangular cross-section, the maximum and minimum values of mean velocity are selected from the quarters of the total cross-section, of side length equal to half the duct side length. In the case of a circular cross-section, the mean values are taken from four measurement radius at right angles to one another. For the calculation of u the velocity in the boundary layer at the wall of the min duct is neglected.

ISO/DTR 25582:2026(en) uu maxmin Irr  (2) 2v where u is the maximum of the arithmetic mean of velocities in a quarter of the measuring cross-section max or at a radius, m/s; u is the minimum of the arithmetic mean of velocities in a quarter of the measuring cross-section min or at a radius, m/s; v is the arithmetic mean over the entire cross section, m/s.

For example, based on the data in Table 2, the index of asymmetry of the flow (Y) at the measuring cross section is 0,026 5 which can completely meet the requirement of ISO 7194.

5.2.2 Numerical simulation

The influence of length of upstream/downstream circular conduit on velocity profile is investigated further by numerical simulations. Figure 1 c) shows the 3D model diagram of the test bench. The length of the upstream straight section of the comparative measuring section is 3,0 m. Figure 5 shows the velocity distribution diagram at the comparative measuring cross-section and test measuring cross-section which are given by numerical simulation. Figure 6 shows the velocity distribution contours at measuring crosssections.

ISO/DTR 25582:2026(en) Horizontal direction Vertical direction a) Comparative measuring cross-section Horizontal direction Vertical direction b) Test measuring cross-section Key r radius of the position where the measuring points are located in the horizontal direction h v measured velocity at the position where the measuring points are located in the horizontal direction h r radius of the position where the measuring points are located in the vertical direction

v measured velocity at the position where the measuring points are located in the vertical direction

Figure 5 — Numerical simulation velocity distributions at horizontal and vertical directions

ISO/DTR 25582:2026(en) a) Comparative measuring cross-section b) Test measuring cross-section Figure 6 — Velocity distribution contours diagram Figure 5 shows the velocity distribution at the measuring sections of the test bench (numerical simulation results). The numerical simulation data of the velocity distribution at the test measuring cross-section are consistent in trend with the experimental measurement data shown in Figure 3. At the comparative measuring cross-section, especially in horizontal direction, the symmetry of the velocity distribution is poorly developed. Table 3 shows numerical simulation results of the points at the horizontal and vertical directions of measuring cross section. These points refer to ISO 3966 and are the same as Figure 3 a). Results show that a) at the test measuring cross-section with satisfactory conditions of the upstream and downstream conduits length, the relative standard deviation of the velocity distribution is 13,99 % and the index of asymmetry of the flow is 0,012 4, and b) at the comparative measuring cross-section with the length of upstream conduit between the elbow and measuring section only 5 times the conduit diameter (not meet the requirements for use of Pitot tubes in ISO 3966), the relative standard deviation of the velocity distribution is 19,77 % (>15 %) and the index of asymmetry of the flow is 0,159 4 (>0,15);

ISO/DTR 25582:2026(en) Table 3 — Numerical simulation data at the measuring cross-section for velocity measurement Local velocity Relative standard Measur- Average velocdeviation of the ve- Index of asym- m/s ing points ity at the cross locity distribution metry of the radius section at the cross section flow (Y) Horizontal direction Vertical direction mm m/s

Comparative measuring cross-section -289 7,43 11,89 -254 9,81 15,29 -207 11,11 16,00 -171 12,42 16,40 -86 15,55 17,03 14,65 19,77 0,159 4 86 17,72 17,01 171 17,79 16,41 207 17,79 15,97 254 16,99 15,38 289 12,85 12,10 Test measuring cross-section -289 11,35 11,60 -254 14,20 14,83 -207 15,49 16,28 -171 16,30 16,80 -86 17,27 17,56 15,12 13,99 0,014 4 86 17,46 17,37 171 16,51 16,39 207 15,96 15,70 254 14,45 14,29 289 11,35 11,21

5.3 Rectangular cross-sections

The influence of length of upstream/downstream rectangular conduit on velocity profile by using Pitot tubes is demonstrated numerical simulation.

Figure 7 shows a 3D model of a hypothetical rectangular air duct. The cross-sectional inner dimension of the air duct is 4,4 m × 4,0 m. The lengths of the straight sections upstream and downstream on the hypothetical simulation cross-section are 84,0 m and 21,0 m, respectively, which meet the requirement for use of Pitot tubes. Figure 8 shows the numerical simulation results of the velocity distribution contours at the simulation cross section. According to log-Chebyshev method mentioned in ISO 3966, a total of 49 selected data collection grid points at the simulation cross-section are shown in Figure 9. Table 4 shows the numerical simulation results of the velocity distribution at the cross section by using grid point statistical method according to Log-Chebyshev method. In this simulation case, the boundary conditions of this numerical simulation include the mass flow rate of the air which is 1 052,28 t/h (as the reference value for comparison). The numerical simulation results indicate that a) the velocity distribution at the simulation cross section is uniform and the relative standard deviation of the velocity distribution is 6,7 %, and b) for the simulation cross section, the fluid flow rate calculated from the average velocity of the cross section is 1 061,51 t/h, with a deviation of 0,9 % from the reference value.

ISO/DTR 25582:2026(en) Dimensions in millimetres Key 1 hypothetical simulation cross-section (4,4 m × 4,0 m) a Flow direction.

Figure 7 — 3D model diagram of a hypothetical rectangular air duct Figure 8 — Velocity distribution contour at the simulation cross section

ISO/DTR 25582:2026(en) Key X /L position of the measuring points corresponds to ratio of the abscissa X in relation to the centre of the section i i to the length of the section Y /H position of the measuring points corresponds to ratio of the ordinate Y in relation to the centre of the section i j to the height of the section Figure 9 — Selected grid points at the hypothetical simulation cross-section (Log-Chebyshev method according to ISO 3966) Table 4 — Grid points numerical simulation results of the flow field at the hypothetical crosssection (Log-Chebyshev method) Statistical results of local velocity at the hypothetical simulation cross-section X /L

-0,447 -0,297 -0,134 0 0,134 0,297 0,447 Y /H

-0,447 m/s 23,4 26,3 27,1 27,0 26,6 25,4 21,2 -0,297 m/s 27,6 28,7 28,6 28,3 28,0 27,4 25,5 -0,134 m/s 28,7 29,3 29,1 28,8 28,5 28,2 27,0 0 m/s 28,9 29,5 29,4 29,2 28,9 28,6 27,4 0,134 m/s 28,8 29,7 29,6 29,4 29,2 28,8 27,4 0,297 m/s 27,7 29,6 29,7 29,6 29,5 29,0 26,7 0,447 m/s 23,7 28,0 28,8 28,9 28,7 27,5 23,1 Average velocity m/s 27,9 Relative standard deviation of % 6,7 the velocity distribution Calculated fluid mass flow rate t/h 1 061,51

ISO/DTR 25582:2026(en)

6 Influence of velocity and temperature distribution uniformity

6.1 General

Actually, in many industrial application scenarios, the measurement conditions with closed conduits cannot meet the requirements for straight conduit lengths upstream and downstream of the measuring crosssection as specified in 5.1. Under such conditions, special attention is paid to the influence of velocity and temperature distribution uniformity at the measuring cross-section when using the velocity-area method with Pitot tubes to measure airflow velocity. This clause illustrates the influence of velocity and temperature distribution uniformity by numerical simulation research.

...

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Symbols
  • 5 Influence of length of upstream/downstream conduit
  • 5.1 General
  • 5.2 Circular cross-sections
  • 5.3 Rectangular cross-sections
  • 6 Influence of velocity and temperature distribution uniformity
  • 6.1 General
  • 7 Influence of devices for improving flow conditions
  • 7.1 General
  • 7.2 Turning vanes
  • 7.3 Profile developer
  • 7.4 Static mixer
  • 7.5 Multiple devices
  • 8 Influence of humidity
  • Bibliography

1 Scope

This document provides data and references to better guide measurement of fluid flow in closed conduits with Pitot static tubes in many complex scenarios of large industrial applications. This document illustrates influences of the following common conditions on fluid flow measurement by using Pitot static tubes:

a) a) influence of length of upstream/downstream conduit,; b) b) influence of velocity and temperature distribution uniformity,; c) c) influence of devices for improving flow conditions,; d) d) influence of humidity.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3966, Measurement of fluid flow in closed conduits — Velocity area method using Pitot static tubes ISO 7194, Measurement of fluid flow in closed conduits — Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot static tubes ISO 5167-2, Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 2: Orifice plates ISO 5167-3, Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 3: Nozzles and Venturi nozzles ISO 5801, Fans — Performance testing using standardized airways

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 3966:2025 apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • — ISO Online browsing platform: available at https://www.iso.org/obp
  • — IEC Electropedia: available at https://www.electropedia.org/

4 Symbols

The symbols given in ISO 3966 and the following symbols apply.

ISO/DTR 25582:(en) Symbol Quantity Dimensions SI unit hr relative humidity of fluid — — Y the index of asymmetry of the flow — —

5 Influence of length of upstream/downstream conduit

5.1 General

As mentioned in ISO 3966:2025, one of provides guidance on the requirements for use of Pitot tubes is, “For guidance, . According to ISO 3966,it is normally assumed that to comply with these conditions there should beis a length of upstream conduit between the beginning of the working section and any significant upstream irregularity of at least 20 diameters of a circular cross-section (or 80 times the hydraulic radius of a conduit of any cross-section shape). Similarly,ISO 3966 also recommends that there should be at least 5 diameters of a circular cross-section (or 20 times the hydraulic radius of a conduit of any cross-section shape), between the measuring cross-section and any significant downstream irregularity” to avoid asymmetry, swirl and turbulences. This clause illustrates the influence of length of upstream/downstream conduit on velocity profile by using Pitot tubes by experimental test and numerical simulation.

5.2 Circular cross-sections

5.2.1 Experimental Testtest

A test bench with circular conduit in laboratory wasis shown in Figure 1Figure 1.. The measuring cross-section wasis located at the long horizontal circular conduit of the test bench. The cross-sectional inner dimension of the circular conduit wasis 0,6 m. The lengths of the upstream and downstream straight conduit of the measuring cross-section wereare 13,0 m and 6,5 m, respectively. Dimensions in metres 25582_ed1fig1a.EPS a) photograph Photograph of long horizontal conduit section with measuring cross-section

ISO/DTR 25582:(en) 25582_ed1fig1b.EPS b) Photograph of measuring cross-section and holes

c) 3D model diagram Key 1 measurement hole in Vertical direction 2 measurement hole in Horizontal direction b) photograph of measuring cross-section and holes 25582_ed1fig1c.EPS Key A flow direction 1 elbow conduit 2 comparative cross section 3 test measuring cross-section 4 straight conduit a Measurement hole in vertical direction.

b Measurement hole in horizontal direction.

c) 3D Flow direction.

Inserted Cells m od el di ag

ISO/DTR 25582:(en) ra

m Figure 1 — Test Benchbench with circular conduit in laboratory In this document, the influence of length of upstream/downstream circular conduit on velocity profile by using Pitot tubes wasis demonstrated through the experimental test in laboratory and numerical simulation. At the measuring cross-section of the test bench, to obtain the velocity distribution, the horizontal and vertical directions wereare selected and there wereare 29 measuring points per direction (see Figure 2Figure 2).). The selection of these measuring points wasis uniformly distributed along the centrelines of the measurement cross-section and does not comply with the velocity-area method. Therefore, the obtained measurement velocity data wereare only for reference in researching the flow velocity distribution. 25582_ed1fig2.EPS Dimensions in millimetres

Key X horizontal direction Y vertical direction Figure 2 — Measuring points at the measuring cross-section for velocity distribution In the test, the medium wasis air. The relative humidity, pressure and density of the air wereare shown in Table 1Table 1,, which also gives the measurement data of the velocity at the measuring cross section. The fluid velocities wereare measured by using Pitot tubes and calculated from the differential pressure existing between the total and static pressures of the Pitot tube placed at these measuring points.

ISO/DTR 25582:(en) Table 1 — Measurement data at the measuring cross-section for velocity distribution Horizontal Directiondirection Vertical Directiondirection Relative Pressur Relative Temperature Density Temperature Pressure Density humidity e humidity 3 3 (°°C) (kg/m ) (°°C) (kPa) (kg/m ) (%)% (kPa) (%)% 20,5 65 101,8 1,201 18,4 65 102,0 1,213 Measuring Differential Measuring Differential Local velocity Local velocity points radius pressure points radius pressure (m/s) (m/s) (mm) (Pa) (mm) (Pa) -280 100,279 12,92 -280 106,094 13,23 -260 124,127 14,38 -260 129,280 14,60 -240 134,535 14,97 -240 144,919 15,46 -220 143,086 15,44 -220 156,500 16,06 -200 155,236 16,08 -200 164,406 16,46 -180 162,356 16,44 -180 171,064 16,79 -160 165,216 16,59 -160 175,698 17,02 -140 172,492 16,95 -140 177,694 17,12 -120 170,939 16,87 -120 182,499 17,35 -100 173,894 17,02 -100 180,745 17,26 -80 174,915 17,07 -80 184,611 17,45 -60 175,860 17,11 -60 184,307 17,43 -40 176,229 17,13 -40 183,821 17,41 -20 174,923 17,07 -20 184,234 17,43 0 174,796 17,06 0 186,085 17,52 20 173,684 17,01 20 184,692 17,45 40 174,463 17,04 40 185,482 17,49 60 173,712 17,01 60 184,367 17,44 80 171,655 16,91 80 181,787 17,31 100 172,366 16,94 100 182,160 17,33 120 169,259 16,79 120 180,632 17,26 140 163,205 16,49 140 175,065 16,99 160 158,207 16,23 160 168,248 16,66 180 147,744 15,69 180 165,612 16,52 200 137,603 15,14 200 154,296 15,95 220 128,610 14,63 220 142,291 15,32 240 114,932 13,83 240 134,029 14,87 260 93,164 12,46 260 115,936 13,83 280 88,966 12,17 280 104,355 13,12

ISO/DTR 25582:(en) Figure 3Figure 3 shows the velocity distributions at horizontal and vertical diameters. Obviously, the velocity distribution exhibits relatively good central symmetry in both horizontal and vertical directions. 25582_ed1fig3a.EPS a) Horizontal direction

b) Vertical direction Key rh radius of the position where the measuring points wereare located in the horizontal direction; vh measured velocity at the position where the measuring points wereare located in the horizontal direction.

ISO/DTR 25582:(en) a) Horizontal direction 25582_ed1fig3b.EPS Key r radius of the position where the measuring points wereare located in the vertical direction;

v measured velocity at the position where the measuring points wereare located in the vertical direction.

b) Vertictal direction Figure 3 — Measuring velocity distributions at horizontal and vertical diameters Figure 4Figure 4 gives positions of the measuring points respectively according to regulations (velocity-area 5 [1] method) of ISO 3966:2025 and EN 12599 :2013 ..

25582_ed1fig4a.EPS 25582_ed1fig4b.EPS

a) according According to ISO 3966:2005 b) according According to EN 12599:2013 Key X horizontal direction Y vertical direction Figure 4 — Measuring points at the measuring cross-section for velocity measurement Table 2Table 2 shows the measuring point statistical results of the flow field at the measuring cross section according to ISO 3966:2025 and EN 12599:2013. The test results indicate that, as the measuring cross-section wasis far enough away from any disturbances, the relative standard deviation of the velocity distribution at the cross section wasis maintained at the level which wasis no more than 15 %. For guidance, it wasIt is normally assumed that the uniformity of velocity distribution is acceptable with σ ≤ 15 %.

ISO/DTR 25582:(en) Table 2 — Measurement data at the measuring cross-section for velocity measurement Local velocity ( Relative standard Measurin Average velocity at deviation of the m/s) g points the cross section velocity distribution at radius ( the cross section (m/s) Horizontal direction Vertical direction mm)

Refer to ISO 3966:2025 -289 11,67 12,05 -254 13,95 14,66 -207 15,74 16,32 -171 16,44 16,85 -86 16,98 17,29 15,04 13,48 86 17,00 17,41 171 16,00 16,62 207 15,05 15,89 254 13,19 14,21 289 11,34 12,07 Refer to EN 12599:20132012 -285 11,98 12,44 -251 14,10 14,82 -212 15,60 16,21 -164 16,53 16,92 -95 16,96 17,26 15,11 12,63 95 16,96 17,37 164 16,15 16,73 212 14,89 15,75 251 13,33 14,35 285 11,57 12,37 Besides, two indexes wereare considered to characterize the symmetry of the velocity distribution:

a) a) According to ISO 7194:2008, for circular ducts, the index of asymmetry of the flow (Y) wasis defined to evaluate the asymmetric flow conditions and wasis not advisable to be greater than 0,15 to make a measurement. The index of asymmetry of the flow (Y) can be calculated by the following Formula (1) (1)::

(1) 𝑛𝑛 2

1 (𝑢𝑢−𝑣𝑣) 𝑖𝑖=1 𝑖𝑖 1⁄2 𝑌𝑌 = [ ] (1) 𝑣𝑣¯ 𝑛𝑛−1 where

ISO/DTR 25582:(en) n wasis the number of radii traversed (4, 6 or 8); ui wasis the mean velocity calculated from the individual point velocity measurements at i radius, m/s; was 𝑣𝑣¯ is the mean axial velocity calculated from all of the individual point velocity measurements, m/s. b) b) According to EN 12599:2012, for rectangular ducts and circular ducts, the following formular wasformula is used as a measure of the irregularity, Irr, of the velocity profile and can be calculated by the following Formula (2) (2).. In the case of a rectangular cross-section, the maximum and minimum values of mean velocity wereare selected from the quarters of the total cross-section, of side length equal to half the duct side length. In the case of a circular cross-section, the mean values wereare taken from four measurement radius at right angles to one another. For the calculation of u the velocity in the boundary min layer at the wall of the duct wasis neglected.

(2) |𝑢𝑢 −𝑢𝑢 | 𝑚𝑚𝑚𝑚𝑚𝑚 𝑚𝑚𝑖𝑖𝑛𝑛 𝐼𝐼𝐼𝐼𝐼𝐼 = (2) 2𝑣𝑣¯ where umax wasis the maximum of the arithmetic mean of velocities in a quarter of the measuring cross-section or at a radius, m/s; umin wasis the minimum of the arithmetic mean of velocities in a quarter of the measuring cross-section or at a radius, m/s; was 𝑣𝑣¯ is the arithmetic mean over the entire cross section, m/s. For example, based on the data in Table 2Table 2,, the index of asymmetry of the flow (Y) at the measuring cross section wasis 0,026 5 which can completely meet the requirement of ISO 7194:2008.

5.2.2 Numerical Simulationsimulation

The influence of length of upstream/downstream circular conduit on velocity profile wasis investigated further by numerical simulations. Figure 1Figure 1 c) shows the 3D model diagram of the test bench. The length of the upstream straight section of the comparative measuring section wasis 3,0 m. Figure 5Figure 5 shows the velocity distribution diagram at the comparative measuring cross-section and test measuring crosssection which wereare given by numerical simulation. Figure 6Figure 6 shows the velocity distribution contours at measuring cross-sections.

25582_ed1fig5a1.EPS 25582_ed1fig5a2.EPS

Horizontal direction Vertical direction a) comparative Comparative measuring cross-section

ISO/DTR 25582:(en) 25582_ed1fig5b1.EPS 25582_ed1fig5b2.EPS

Horizontal direction Vertical direction b) test Test measuring cross-section Key r radius of the position where the measuring points wereare located in the horizontal direction; h v measured velocity at the position where the measuring points wereare located in the horizontal direction. h rv radius of the position where the measuring points wereare located in the vertical direction; vv measured velocity at the position where the measuring points wereare located in the vertical direction. Figure 5 — Numerical simulation velocity distributions at horizontal and vertical directions 25582_ed1fig6a.EPS 25582_ed1fig6b.EPS

a) comparative Comparative measuring cross-section b) test Test measuring cross-section Figure 6 — Velocity distribution contours diagram Figure 5Figure 5 shows the velocity distribution at the measuring sections of the test bench (numerical simulation results). The numerical simulation data of the velocity distribution at the test measuring crosssection wereare consistent in trend with the experimental measurement data shown in Figure 3Figure 3.. At the comparative measuring cross-section, especially in horizontal direction, the symmetry of the velocity distribution wasis poorly developed. Table 3Table 3 shows numerical simulation results of the points at the horizontal and vertical directions of measuring cross section. These points refer to ISO 3966:2025 and wereare the same as Figure 3Figure 3 a). Results show that:

ISO/DTR 25582:(en) a) 1) Atat the test measuring cross-section with satisfactory conditions of the upstream and downstream conduits length, the relative standard deviation of the velocity distribution wasis 13,99 % and the index of asymmetry of the flow wasis 0,012 4;, and b) 2) Atat the comparative measuring cross-section with the length of upstream conduit between the elbow and measuring section only 5 times the conduit diameter (not meet the requirements for use of Pitot tubes in ISO 3966: 2025), the relative standard deviation of the velocity distribution wasis 19,77 % (>15 %) and the index of asymmetry of the flow wasis 0,159 4 (>0,15); Table 3 — Numerical simulation data at the measuring cross-section for velocity measurement Local velocity ( Relative Average standard m/s) Measurin Index of velocity at deviation of the g points asymmetry the cross velocity radius ( of the flow Vertical section distribution at Horizontal direction (Y) mm) direction the cross section (m/s)

Comparative measuring cross-section -289 7,43 11,89 -254 9,81 15,29 -207 11,11 16,00 -171 12,42 16,40 -86 15,55 17,03 14,65 19,77 0,159 4 86 17,72 17,01 171 17,79 16,41 207 17,79 15,97 254 16,99 15,38 289 12,85 12,10 Test measuring cross-section -289 11,35 11,60 -254 14,20 14,83 -207 15,49 16,28 -171 16,30 16,80 -86 17,27 17,56 15,12 13,99 0,014 4 86 17,46 17,37 171 16,51 16,39 207 15,96 15,70 254 14,45 14,29 289 11,35 11,21

ISO/DTR 25582:(en)

5.3 Rectangular cross-sections

The influence of length of upstream/downstream rectangular conduit on velocity profile by using Pitot tubes wasis demonstrated numerical simulation.

Figure 7Figure 7 shows a 3D model of a hypothetical rectangular air duct. The cross-sectional inner dimension of the air duct wasis 4,4 m × 4,0 m. The lengths of the straight sections upstream and downstream on the hypothetical simulation cross-section wereare 84,0 m and 21,0 m, respectively, which meet the requirement for use of Pitot tubes. Figure 8Figure 8 shows the numerical simulation results of the velocity distribution contours at the simulation cross section. According to log-Chebyshev method mentioned in ISO 3966:2025, a total of 49 selected data collection grid points at the simulation cross-section wereare shown in Figure 9Figure 9. Table 4. Table 4 shows the numerical simulation results of the velocity distribution at the cross section by using grid point statistical method according to Log-Chebyshev method. In this simulation case, the boundary conditions of this numerical simulation include the mass flow rate of the air which wasis 1 052,28 t/h (as the reference value for comparison). The numerical simulation results indicate that:

a) 1) Thethe velocity distribution at the simulation cross section wasis uniform and the relative standard deviation of the velocity distribution wasis 6,7 %.%, and b) 2) Forfor the simulation cross section, the fluid flow rate calculated from the average velocity of the cross section wasis 1 061,51 t/h, with a deviation of 0,9 % from the reference value. 25582_ed1fig7.EPS Dimensions in millimetres

Key A flow direction 1 hypothetical simulation cross-section (4,4 m × 4,0 m) a Flow direction.

Figure 7 — 3D model diagram of ana hypothetical rectangular air duct

ISO/DTR 25582:(en) 25582_ed1fig8.EPS

Figure 8 — Velocity distribution contour at the simulation cross section 25582_ed1fig9.EPS

Key X /L The position of the measuring points corresponds to ratio of the abscissa X in relation to the centre of the section to the length of i i the section Y /H The position of the measuring points corresponds to ratio of the ordinate Y in relation to the centre of the section i j to the height of the section Figure 9 — Selected grid points at the hypothetical simulation cross-section (Log-Chebyshev method according to ISO 3966:2025)

ISO/DTR 25582:(en) Table 4 — Grid points numerical simulation results of the flow field at the hypothetical cross-section (Log-Chebyshev method) Statistical results of local velocity at the hypothetical simulation cross-section X /L

-0,447 -0,297 -0,134 0 0,134 0,297 0,447 Y /H

-0,447 m/s 23,4 26,3 27,1 27,0 26,6 25,4 21,2 -0,297 m/s 27,6 28,7 28,6 28,3 28,0 27,4 25,5 -0,134 m/s 28,7 29,3 29,1 28,8 28,5 28,2 27,0 0 m/s 28,9 29,5 29,4 29,2 28,9 28,6 27,4 0,134 m/s 28,8 29,7 29,6 29,4 29,2 28,8 27,4 0,297 m/s 27,7 29,6 29,7 29,6 29,5 29,0 26,7 0,447 m/s 23,7 28,0 28,8 28,9 28,7 27,5 23,1 Average velocity m/s 27,9 Relative standard deviation of % 6,7 the velocity distribution Calculated fluid mass flow rate t/h 1 061,51

6 Influence of velocity and temperature distribution uniformity

6.1 General

Actually, in many industrial application scenarios, the measurement conditions with closed conduits cannot meet the requirements for straight conduit lengths upstream and downstream of the measuring cross-section as specified in 5.1Section 5.1.. Under such conditions, special attention is paid to the influence of velocity and temperature distribution uniformity at the measuring cross-section when using the velocity-area method with Pitot tubes to measure airflow velocity. This clause illustrates the influence of velocity and temperature distribution uniformity by numerical simulation research.

...