ISO 10701:2026
(Main)Steel and iron — Determination of sulfur content — Methylene blue spectrophotometric method
- Abstract
This document specifies a methylene blue spectrophotometric method for the determination of sulfur in steel and iron. The method is applicable to sulfur contents between 0,000 3 % (mass fraction) to 0,010 % (mass fraction).
- Status
- Published
- Publication Date
- 09-Nov-2026
- Technical Committee
- ISO/TC 17/SC 1 - Methods of determination of chemical composition
- Drafting Committee
- ISO/TC 17/SC 1 - Methods of determination of chemical composition
- Current Stage
- 6060 - International Standard published
- Start Date
- 10-Nov-2026
- Completion Date
- 10-Nov-2026
ISO 10701:2026 is an International Standard from ISO for determining sulfur in steel and iron by a methylene blue spectrophotometric method. It applies to sulfur contents from 0,000 3 % to 0,010 % mass fraction, which makes it relevant for low-level sulfur control in metallurgy and analytical laboratories.
What does ISO 10701:2026 specify?
ISO 10701:2026 specifies the overall method for measuring sulfur in steel and iron, from sample dissolution through spectrophotometric reading. It is organized into clauses covering scope, references, principle, reagents, apparatus, sampling, procedure, calculation and reporting, with two informative annexes on precision.
| Annex | What it covers |
|---|---|
| Annex A | Additional information on the international precision test |
| Annex B | Graphical representation of precision data |
The standard is built around a wet-chemical preparation followed by formation of methylene blue and measurement at about 665 nm. In practice, the document tells the laboratory how to prepare the sample, avoid contamination, build the calibration curve, and report the sulfur content consistently.
What are the key requirements of ISO 10701:2026?
Clause 4, Principle - ISO 10701:2026 dissolves the test portion in hydrochloric and nitric acids, removes those acids with perchloric acid, reduces sulfur compounds to hydrogen sulfide in nitrogen, absorbs the gas in zinc acetate solution, then develops methylene blue for measurement. This sequence matters because each chemical step affects recovery of sulfur.
Interfering elements and application range - ISO 10701:2026 notes niobium, silicon, tantalum and titanium as interferences, and Table 1 links their maximum contents to the allowable test portion mass and sulfur range. That means the analyst must choose the sample mass to match the alloy composition before starting the test.
Clause 5, Reagents - ISO 10701:2026 requires recognized analytical-grade reagents with very low sulfur content and freshly prepared grade 2 water. Several solutions are prepared on site, including the reducing reagent, absorbing solution and sulfur standard solutions, so reagent quality directly affects the blank and the calibration.
Clause 6, Apparatus - ISO 10701:2026 requires class A volumetric glassware and a reduction-distillation setup with close-fitting ground-glass joints, plus a spectrophotometer set to about 665 nm. Stable low blank values are required before routine use of the distillation apparatus.
Clause 7 and 8.1 to 8.4, Sampling and procedure - ISO 10701:2026 requires sampling and sample preparation in accordance with ISO 14284 or suitable national standards, then uses different test portions and absorption volumes depending on the expected sulfur content. This is important because the method has two measurement ranges and the handling changes with concentration.
Clause 8.2 and 10.1 to 10.3, Blank and procedural control - ISO 10701:2026 calls for a blank test in parallel with the determination, and the notes stress strict control of sulfur contamination and of the reduction temperature. The procedure should be run in a very clean atmosphere, and the reducing temperature is kept close to 114 °C to 118 °C for reliable sulfur recovery.
Clause 9 and 11, Results and report - ISO 10701:2026 converts absorbance to sulfur mass using the calibration curve, then calculates sulfur content from the test and blank values. The test report must identify the sample, state the method as ISO 10701:2026, give the result with units, and note unusual features or any non-specified operation.
Who uses ISO 10701:2026?
ISO 10701:2026 is used by analytical laboratories, steel and iron producers, and quality control teams that need sulfur data at very low levels. It is also relevant to buyers and auditors who need a documented laboratory method for comparing supplier material, verifying product quality, or checking compliance with internal specifications.
What changed in ISO 10701:2026 from the previous edition?
ISO 10701:2026 replaces ISO 10701:1994 and states that it has been technically revised. The changes listed in the foreword are:
- the normative references have been updated;
- Clause 3, Terms and definitions, has been added and later clauses renumbered;
- the former special case in Clause 10 has been moved into 8.3.1;
- the precision data have been re-evaluated.
Which standards are used with ISO 10701:2026?
ISO 10701:2026 refers to these companion standards and supporting methods:
- ISO 648 - specifies single-volume pipettes used for volumetric handling.
- ISO 1042 - specifies one-mark volumetric flasks used to make standard and test solutions.
- ISO 3696 - specifies water for analytical laboratory use, which supports low-contamination analysis.
- ISO 14284 - covers sampling and preparation of samples for chemical composition testing in steel and iron.
- ISO 5725-2 - was used for the statistical treatment of precision data.
- ISO 5725-3 - was also used in the precision evaluation for the collaborative study.
What does the ISO 10701:2026 document contain?
ISO 10701:2026 contains the full analytical workflow: reagents and solutions, glassware and instrument setup, sampling guidance, the reduction-distillation apparatus, colour development steps, calibration solution preparation, and the calculation formula for sulfur content. It also includes procedural notes on contamination control, temperature control and purification checks, which help the laboratory maintain low blanks and consistent recovery.
Annex A gives the interlaboratory precision study behind the method, including the sample set and precision results. Annex B presents the precision data graphically, showing the relationship between sulfur content and repeatability or reproducibility limits.
Relations
- Effective Date
- 18-Jan-2025
Get Certified
Connect with accredited certification bodies for this standard

Element Materials Technology
Materials testing and product certification.

Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
ISO 10701:2026 is a standard published by the International Organization for Standardization (ISO). Its full title is "Steel and iron — Determination of sulfur content — Methylene blue spectrophotometric method". This standard covers: This document specifies a methylene blue spectrophotometric method for the determination of sulfur in steel and iron. The method is applicable to sulfur contents between 0,000 3 % (mass fraction) to 0,010 % (mass fraction).
This document specifies a methylene blue spectrophotometric method for the determination of sulfur in steel and iron. The method is applicable to sulfur contents between 0,000 3 % (mass fraction) to 0,010 % (mass fraction).
ISO 10701:2026 is classified under the following ICS (International Classification for Standards) categories: 77.080.01 - Ferrous metals in general. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 10701:2026 has the following relationships with other standards: It is inter standard links to ISO 10701:1994. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO 10701:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
International
Standard
ISO 10701
Second edition
Steel and iron — Determination of
2026-11
sulfur content — Methylene blue
spectrophotometric method
Aciers et fontes — Détermination du soufre — Méthode
spectrophotométrique au bleu de méthylène
Reference number
© ISO 2026
All rights reserved.
This ISO publication is protected by copyright and is owned by ISO and/or its licensors.
The content of this ISO publication is provided under licence, not sold. Use is subject to the applicable licence terms issued by ISO,
an ISO member body, or an authorized third-party distributor.
Except as required for implementation or expressly permitted by a separate licence, no part of this ISO publication may be
reproduced, distributed, modified, used, or made available in any form or by any means – electronic or mechanical, including
photocopying, scanning, recording, or posting on internal or external digital platforms.
Any use beyond the scope of the granted rights is prohibited and may result in legal action.
ISO copyright office
CP 401 • CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 1
5 Reagents . 2
6 Apparatus . 4
7 Sampling and sample preparation . 5
8 Procedure . 5
8.1 Test portion .6
8.2 Blank test .6
8.3 Determination .6
8.3.1 Preparation of the test solution .6
8.3.2 Reduction and distillation .6
8.3.3 Colour development .7
8.3.4 Spectrophotometric measurements .7
8.4 Establishment of the calibration curves .7
8.4.1 Preparation of the calibration solutions .7
8.4.2 Spectrophotometric measurements .7
8.4.3 Plotting the calibration curve .7
9 Expression of results . 8
9.1 Method of calculation .8
9.2 Precision . . .8
10 Notes on procedure . 9
11 Test report . 10
Annex A (informative) Additional information on the international precision test .11
Annex B (informative) Graphical representation of precision data .12
Bibliography .13
iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 17, Steel, Subcommittee SC 1, Methods of
determination of chemical composition.
This second edition cancels and replaces the first edition (ISO 10701:1994), which has been technically
revised.
The main changes are as follows:
— Clause 2, Normative references has been updated;
— the mandatory Clause 3, terms and definitions has been added and subsequent clauses have been
renumbered;
— Clause 10, Special case, has been moved into 8.3.1;
— the precision data has been re-evaluated.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
iv
International Standard ISO 10701:2026(en)
Steel and iron — Determination of sulfur content —
Methylene blue spectrophotometric method
1 Scope
This document specifies a methylene blue spectrophotometric method for the determination of sulfur in
steel and iron.
The method is applicable to sulfur contents between 0,000 3 % (mass fraction) to 0,010 % (mass fraction).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 648, Laboratory glassware — Single-volume pipettes
ISO 1042, Laboratory glassware — One-mark volumetric flasks
ISO 3696, Water for analytical laboratory use — Specification and test methods
ISO 14284, Steel and iron — Sampling and preparation of samples for the determination of chemical composition
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminology databases for use in standardization at the following addresses
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
4 Principle
Dissolution of a test portion in a mixture of hydrochloric and nitric acids.
Evaporation with perchloric acid until white fumes appear to remove hydrochloric and nitric acids.
Dissolution of the salts in hydrochloric acid. Evolution of hydrogen sulfide by reducing with a mixture of
hydroiodic and hypophosphorous acids in a nitrogen atmosphere, distillation, and absorption into a zinc
acetate solution.
Formation of methylene blue by reacting with N,N-dimethyl-p-phenylenediamine and iron(III) solution.
Spectrophotometric measurement at a wavelength of about 665 nm.
Niobium, silicon, tantalum and titanium interfere in the determination of sulfur.
Depending on the contents of the interfering elements, the application ranges and test portion masses given
in Table 1 apply.
Table 1 — Application ranges and test portions
Maximum allowable content of the interfering ele-
ments
Test portion Application ranges ∆w
s
% (mass fraction)
g
% (mass fraction)
Nb Si Ta Ti
0,5 1,0 0,3 1,0 1,0 0,000 3 to 0,001 0
1,0 2,0 0,6 2,0 0,50 0,001 0 to 0,010
5 Reagents
During the analysis, unless otherwise stated, use only reagents of recognized analytical grade with a very
low sulfur content, and only freshly prepared grade 2 water as specified in ISO 3696.
5.1 Hydrochloric acid, ρ about 1,19 g/ml.
5.2 Hydrochloric acid, ρ about 1,19 g/ml, diluted 1 + 15.
5.3 Perchloric acid, ρ about 1,54 g/ml.
5.4 Hydrobromic acid, ρ approximately 1,48 g/ml.
5.5 Mixture of hydrochloric and nitric acids.
Mix one volume of hydrochloric acid (5.1) and one volume of nitric acid, ρ about 1,40 g/ml.
Prepare immediately before use.
5.6 Reducing reagent solution.
Transfer 200 ml of hydriodic acid, ρ about 1,70 g/ml and 50 ml of hypophosphorous acid, ρ about
1,49 g/ml into the purifying apparatus (see Figure 1). Purge with nitrogen (5.12) at a flow rate of 100 ml/
min for 10 min, to mix the acids and expel air from the system. Switch on the electric heating mantle. Heat
to boiling and boil gently for about 120 min at a temperature of about 115 °C in a current of nitrogen. When
purification is completed (see 10.3), switch off the electric heating mantle. Then cool the solution and keep
it in a brown bottle.
5.7 Absorbing solution.
Dissolve 5 g of zinc acetate dihydrate [Zn(CH COO) .2H O] in 400 ml of water. Add 200 ml of sodium
3 2 2
hydroxide, 30 g/l, and 70 g of ammonium chloride, and then dilute to 1 000 ml with water.
5.8 Iron solution, 10 g/l.
Weigh, to the nearest 0,01 g, 1,00 g of pure iron, free from sulfur. Transfer to a 300 ml beaker, cover with a
watch glass, dissolve by heating with an addition of 20 ml of hydrochloric acid (ρ about 1,19 g/ml, diluted
1 + 1) and boil gently for about 10 min. Then add 2 ml of nitric acid (ρ about 1,40 g/ml) drop by drop to
oxidize iron. Remove the oxides of nitrogen by boiling, and cool to room temperature. Transfer to a 100 ml
one-mark volumetric flask, dilute to the mark with water and mix.
5.9 Iron (lll) chloride solution.
Dissolve 1 g of iron (Ш) chloride hexahydrate (FeCl .6H O) in about 40 ml of water. Add 10 ml of hydrochloric
3 2
acid (5.1) and dilute to 100 ml with water.
5.10 N,N-dimethyl-p-phenylenediamine in hydrochloric acid medium.
Dissolve 0,5 g of N,N-dimethyl-p-phenylenediamine dihydrochloride [NH C H N(CH ) .2HCl] in about
2 6 4 3 2
100 ml of water. Add 230 ml of hydrochloric acid (5.1) and dilute to 500 ml with water.
5.11 Sulfur standard solutions.
5.11.1 Sulfur standard solution, 1 g/l.
Weigh, to the nearest 0,000 1 g, 5,435 2 g of potassium sulfate [minimum purity: 99,5 % (mass fraction)],
previously dried at 110 °C for 2 h and cooled to room temperature in a desiccator. Dissolve in water, transfer
to a 1 000 ml one-mark volumetric flask quantitatively, dilute to the mark with water and mix.
1 ml of this standard solution contains 1 mg of sulfur.
5.11.2 Sulfur standard solution, 10 mg/l.
Transfer 10,0 ml of the standard solution (5.11.1) to a 1 000 ml one-mark volumetric flask, dilute to the mark
with water and mix.
1 ml of this standard solution contains 10 µg of sulfur.
5.11.3 Sulfur standard solution, 1 mg/l.
Transfer 10,0 ml of the standard solution (5.11.2) to a 100 ml one-mark volumetric flask, dilute to the mark
with water and mix.
Prepare the solution immediately before use.
1 ml of this standard solution contains 1 µg of sulfur.
5.12 Nitrogen [purity: >99,5 % (volume fraction)].
Key
1 double surface condenser or equivalent (34 cm long)
2 nitrogen inlet
3 hydrogen sulfide trap (18 cm × 2, 5 cm)
4 thermometer
5 three-neck flask (capacity: 500 ml)
Figure 1 — Example of an apparatus for purification of the reducing mixture
6 Apparatus
All volumetric glassware shall be class A, in accordance with ISO 648 or ISO 1042, as appropriate.
Ordinary laboratory apparatus, and the following.
6.1 Apparatus for reduction and distillation
Assemble the apparatus for reduction and distillation as shown i
...