Paints and varnishes — Determination of release rate of biocides from antifouling paints — Part 2: Determination of copper-ion concentration in the extract and calculation of the release rate

ISO 15181-2:2007 specifies the apparatus and analytical method for determining the amount of copper (based) biocide that has been released from an antifouling paint into artificial seawater in accordance with the procedure given in ISO 15181-1. It determines the copper-ion concentration and gives the final calculation for the release rate of copper under the specified laboratory conditions. It is designed to generally allow the concurrent determination of copper ions and other biocides that might be released by a given antifouling paint through the analysis of separate sub-samples of an artificial seawater extract generated in accordance with the procedure given in ISO 15181-1, and analysed in accordance with the procedures given in other parts of this International Standard. When used in conjunction with ISO 15181-1, the practical limits on the quantitative measurement of release rates by this method are from 1,8 micrograms per square centimetre per day to 500 micrograms per square centimetre per day. The quantitative measurement of release rates below this range will require the use of an analytical method with a lower limit of quantitation for copper.

Peintures et vernis — Détermination du taux de lixiviation des biocides contenus dans les peintures antisalissures — Partie 2: Détermination de la concentration ionique du cuivre dans l'extrait et calcul du taux de lixiviation

L'ISO 15181-2:2007 spécifie l'appareillage et l'analyse technique permettant de déterminer la teneur en biocide à base de cuivre relargué par une peinture antisalissures dans l'eau de mer synthétique conformément au mode opératoire donné dans l'ISO 15181-1. Elle détermine la concentration en ions cuivre et donne le calcul final du taux de lixiviation de cuivre dans les conditions spécifiées de laboratoire. L'ISO 15181-2:2007 est destinée, de façon générale, à permettre de déterminer simultanément les ions cuivre et d'autres biocides susceptibles d'être relargués par une peinture antisalissures donnée à partir de l'analyse de sous-échantillons séparés d'extrait d'eau de mer synthétique prélevés conformément au mode opératoire donné dans l'ISO 15181-1 et analysés conformément aux modes opératoires donnés dans les autres parties de la présente Norme internationale. Conjointement à l'ISO 15181-1, les limites pratiques de quantification des taux de lixiviation par la présente méthode sont comprises entre 1,8 microgrammes par centimètre carré par jour et 500 microgrammes par centimètre carré par jour. La quantification de taux de lixiviation inférieurs à cette plage nécessite d'appliquer une méthode d'analyse dont la limite de quantification du cuivre est inférieure.

General Information

Status
Published
Publication Date
29-May-2007
Current Stage
9093 - International Standard confirmed
Start Date
02-May-2023
Completion Date
14-Feb-2026

Relations

Effective Date
09-Feb-2026
Effective Date
12-Feb-2026
Effective Date
06-Jun-2022
Effective Date
15-Apr-2008

Overview

ISO 15181-2:2007 - Paints and varnishes - Determination of release rate of biocides from antifouling paints - Part 2 describes the analytical method and apparatus for measuring copper-ion concentration released from antifouling paints into artificial seawater, and for calculating the copper release rate (expressed in µg·cm−2·d−1) under the laboratory conditions defined in ISO 15181-1. The standard is intended for repeatable, quality-assurance testing and material selection rather than direct environmental exposure estimates.

Key topics and requirements

  • Scope and purpose: Specifies analysis of copper-based biocides in extracts produced according to ISO 15181-1 and provides the final calculation for release rate.
  • Analytical method: Primary technique is atomic absorption spectrometry (AAS) with autosampler or an alternative method that demonstrates a limit of quantitation (LOQ) for copper in artificial seawater of ≤ 10 µg/L (LOQ determined per ASTM D6442-06 Annex 2).
  • Sample handling: Acidify extracts (0.10 mL concentrated nitric acid per 100 mL), agitate, filter (0.45 µm), store at 2–6 °C up to 14 days, and equilibrate to room temperature before analysis.
  • Calibration and quality checks: Use five-point calibration in artificial seawater and recovery check standards at 10, 50 and 200 µg/L. Recovery acceptance: (100 ± 15)% at 10 µg/L and (100 ± 10)% at 50 and 200 µg/L.
  • Calculation: Convert measured copper concentration in the extract to a release rate (µg·cm−2·d−1). When standard volume (1.5 L), area (200 cm2) and time are used, the standard provides a simplified expression (R ∝ C × 0.18 / t).
  • Quantitative limits: Practical measurement range when used with ISO 15181-1 is approximately 1.8 to 500 µg·cm−2·d−1; lower release rates require more sensitive analytical LOQs.

Applications and users

  • Who uses it: Paint manufacturers, independent testing laboratories, R&D teams, quality control personnel, certification bodies and product formulators working with antifouling coatings.
  • Practical uses:
    • Routine quality-control testing of copper-based antifouling paints.
    • Comparative material selection and product development.
    • Laboratory-based release-rate characterization for product specifications.
  • Limitations: Results typically overestimate in-service environmental release rates (often by an order of magnitude); not suitable alone for regulatory environmental-risk assessments or direct environmental loading estimates without applying appropriate correction factors.

Related standards

  • ISO 15181-1:2007 - General method for extraction of biocides (required companion).
  • Other parts of ISO 15181 (Parts 3–5) - methods for different biocides.
  • ISO 3696 - Water for analytical laboratory use.
  • ASTM D6442-06 - LOQ determination for copper in substitute ocean water.

Keywords: ISO 15181-2:2007, antifouling paints, copper-ion concentration, release rate, artificial seawater, atomic absorption spectrometer, biocide release rate, ISO 15181-1.

Buy Documents

Standard

ISO 15181-2:2007 - Paints and varnishes -- Determination of release rate of biocides from antifouling paints

English language (10 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 15181-2:2007 - Peintures et vernis -- Détermination du taux de lixiviation des biocides contenus dans les peintures antisalissures

French language (10 pages)
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

ISO 15181-2:2007 is a standard published by the International Organization for Standardization (ISO). Its full title is "Paints and varnishes — Determination of release rate of biocides from antifouling paints — Part 2: Determination of copper-ion concentration in the extract and calculation of the release rate". This standard covers: ISO 15181-2:2007 specifies the apparatus and analytical method for determining the amount of copper (based) biocide that has been released from an antifouling paint into artificial seawater in accordance with the procedure given in ISO 15181-1. It determines the copper-ion concentration and gives the final calculation for the release rate of copper under the specified laboratory conditions. It is designed to generally allow the concurrent determination of copper ions and other biocides that might be released by a given antifouling paint through the analysis of separate sub-samples of an artificial seawater extract generated in accordance with the procedure given in ISO 15181-1, and analysed in accordance with the procedures given in other parts of this International Standard. When used in conjunction with ISO 15181-1, the practical limits on the quantitative measurement of release rates by this method are from 1,8 micrograms per square centimetre per day to 500 micrograms per square centimetre per day. The quantitative measurement of release rates below this range will require the use of an analytical method with a lower limit of quantitation for copper.

ISO 15181-2:2007 specifies the apparatus and analytical method for determining the amount of copper (based) biocide that has been released from an antifouling paint into artificial seawater in accordance with the procedure given in ISO 15181-1. It determines the copper-ion concentration and gives the final calculation for the release rate of copper under the specified laboratory conditions. It is designed to generally allow the concurrent determination of copper ions and other biocides that might be released by a given antifouling paint through the analysis of separate sub-samples of an artificial seawater extract generated in accordance with the procedure given in ISO 15181-1, and analysed in accordance with the procedures given in other parts of this International Standard. When used in conjunction with ISO 15181-1, the practical limits on the quantitative measurement of release rates by this method are from 1,8 micrograms per square centimetre per day to 500 micrograms per square centimetre per day. The quantitative measurement of release rates below this range will require the use of an analytical method with a lower limit of quantitation for copper.

ISO 15181-2:2007 is classified under the following ICS (International Classification for Standards) categories: 87.040 - Paints and varnishes. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 15181-2:2007 has the following relationships with other standards: It is inter standard links to EN ISO 15181-1:2007, EN ISO 15181-2:2007, ISO 19106:2004, ISO 15181-2:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO 15181-2:2007 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 15181-2
Second edition
2007-06-01
Paints and varnishes — Determination of
release rate of biocides from antifouling
paints —
Part 2:
Determination of copper-ion
concentration in the extract and
calculation of the release rate
Peintures et vernis — Détermination du taux de lixiviation des biocides
contenus dans les peintures antisalissures —
Partie 2: Détermination de la concentration ionique du cuivre dans
l'extrait et calcul du taux de lixiviation

Reference number
©
ISO 2007
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.

©  ISO 2007
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2007 – All rights reserved

Contents Page
Foreword. iv
Introduction . v
1 Scope. 1
2 Normative references. 1
3 Principle. 1
4 Supplementary information required for the copper extraction procedure . 2
5 Apparatus. 2
6 Reagents and materials . 2
7 Test samples. 2
8 Procedure. 3
9 Calculation and expression of results. 4
10 Precision. 7
11 Test report. 7
Annex A (normative) Supplementary information required for the copper extraction procedure . 9
Bibliography . 10

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 15181-2 was prepared by Technical Committee ISO/TC 35, Paints and varnishes, Subcommittee SC 9,
General test methods for paints and varnishes.
This second edition cancels and replaces the first edition (ISO 15181-2:2000), which has been technically
revised.
ISO 15181 consists of the following parts, under the general title Paints and varnishes — Determination of
release rate of biocides from antifouling paints:
⎯ Part 1: General method for extraction of biocides
⎯ Part 2: Determination of copper-ion concentration in the extract and calculation of the release rate
⎯ Part 3: Calculation of the zinc ethylene-bis(dithiocarbamate) (zineb) release rate by determination of the
concentration of ethylenethiourea in the extract
⎯ Part 4: Determination of pyridine-triphenylborane (PTPB) concentration in the extract and calculation of
the release rate
⎯ Part 5: Calculation of the tolylfluanid and dichlofluanid release rate by determination of the concentration
of dimethyltolylsulfamide (DMST) and dimethylphenylsulfamide (DMSA) in the extract
iv © ISO 2007 – All rights reserved

Introduction
By using standard conditions of temperature, salinity and pH at low biocide concentrations in the surrounding
artificial seawater, a repeatable value of the release rate under the specified laboratory conditions can be
determined using the method given in this part of ISO 15181, which can be used for quality assurance and
material selection purposes. The actual release rate of biocides from antifouling paints on ships' hulls into the
environment will, however, depend on many factors, such as ship operating schedules, length of service,
berthing conditions, paint condition, as well as the temperature, salinity, pH, pollutants and biological
community in a particular area.
The results of this test do not reflect environmental biocide release rates for antifouling products and are not
suitable for direct use in the process of generating environmental-risk assessments, producing environmental-
loading estimates or for establishing release rate limits for regulatory purposes. In comparison with copper
and organotin release rates obtained either by direct or indirect measurements of the copper release rate from
ships' hulls and from measurements made on panels exposed in harbours, all available data indicate that the
results obtained using this generic test method significantly overestimate the release rates of biocides under
in-service conditions. Published results demonstrate that the results of this test method are generally higher
than direct in situ measurements of copper and organotin release rates from in-service ship hulls by a factor of
[1, 2]
about 10 or more for several commercial antifouling coatings . A similar relationship is expected to be
found for other biocides. Realistic estimates of the biocide release rate from a ship’s hull under in-service
conditions can only be obtained from this test method if this difference is taken into account.
Where the results of this test method are used in the process of generating environmental-risk assessments,
producing environmental-loading estimates or for regulatory purposes, it is most strongly recommended that
the relationship between laboratory release rates and actual environmental inputs be taken into account to
allow a more accurate estimate of the biocide release rate from antifouling coatings under real-life conditions
[2]
to be obtained. This can be accomplished through the application of appropriate correction factors .

INTERNATIONAL STANDARD ISO 15181-2:2007(E)

Paints and varnishes — Determination of release rate
of biocides from antifouling paints —
Part 2:
Determination of copper-ion concentration in the extract
and calculation of the release rate
1 Scope
This part of ISO 15181 specifies the apparatus and analytical method for determining the amount of copper
(based) biocide that has been released from an antifouling paint into artificial seawater in accordance with the
procedure given in ISO 15181-1.
It determines the copper-ion concentration and gives the final calculation for the release rate of copper under
the specified laboratory conditions. This part of ISO 15181 is designed to generally allow the concurrent
determination of copper ions and other biocides that might be released by a given antifouling paint through the
analysis of separate sub-samples of an artificial seawater extract generated in accordance with the procedure
given in ISO 15181-1, and analysed in accordance with the procedures given in other parts of this
International Standard.
When used in conjunction with ISO 15181-1, the practical limits on the quantitative measurement of release
–2 –1 –2 –1
rates by this method are from 1,8 µg⋅cm ⋅d to 500 µg⋅cm ⋅d . The quantitative measurement of release
rates below this range will require the use of an analytical method with a lower limit of quantitation for copper
in artificial seawater than the limit specified in 5.1.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 3696, Water for analytical laboratory use — Specification and test methods
ISO 15181-1:2007, Paints and varnishes — Determination of release rate of biocides from antifouling
paints — Part 1: General method for extraction of biocides
ASTM D 6442-06, Standard Test Method for Determination of Copper Release Rate from Antifouling Coatings
in Substitute Ocean Water
3 Principle
The concentration of the copper ions released into artificial seawater in accordance with the procedure given
in ISO 15181-1 is determined by the use of an atomic absorption spectrometer or by an alternative analytical
method, provided that it demonstrates a limit of quantitation for copper in artificial seawater of 10 µg/l or less.
The release rate of the biocide is then calculated as copper metal.
4 Supplementary information required for the copper extraction procedure
The items of supplementary information required to be able to use the general extraction procedure, described
in ISO 15181-1, for copper-based biocides are given in Annex A.
5 Apparatus
5.1 Atomic absorption spectrometer, preferably with autosampler, or other suitable instrument, which
has a limit of quantitation for copper in artificial seawater of 10 µg/l or less. The limit of quantitation shall be
determined by the procedure given in Annex 2 (Determination of the LOQ for Copper in Substitute Ocean
Water for the Analytical Method) of ASTM D 6442-06.
5.2 Mechanical shaker, with appropriate holders.
5.3 Dispensers, automatic or repeating, for reagents.
5.4 Pipettes, of appropriate volume, with disposable tips.
5.5 Volumetric flasks, of appropriate volume.
5.6 Sample tubes, of appropriate capacity, with screw closures, made of an inert material.
NOTE Polypropylene, polycarbonate and borosilicate glass have been found to be suitable.
6 Reagents and materials
Suppliers’ material safety data sheets should be consulted for details of any hazards associated with the
reagents listed below, and the risks associated with their use should be assessed. Appropriate protective
clothing and equipment should be utilized.
Unless otherwise specified, use only reagents of recognized analytical grade.
6.1 Cleaning reagents.
Use one of the following reagents for cleaning all the equipment:
6.1.1 Hydrochloric acid, concentrated aqueous solution, 37 % by mass.
6.1.2 Hydrochloric acid, aqueous solution, 10 % by volume.
6.2 Nitric acid, concentrated (ρ approximately 1,42 g/ml).
6.3 Artificial seawater, as defined in ISO 15181-1.
6.4 Water, conforming to the requirements of grade 2 of ISO 3696.
7 Test samples
Use extracts taken from the release rate measuring containers as described in ISO 15181-1.
2 © ISO 2007 – All rights reserved

8 Procedure
8.1 General
Carry out all determinations on the extract using the following method. An alternative method of analysis is
allowed providing it has a limit of quantitation for copper ions in artificial seawater of 10 µg/l or less,
determined by the procedure given in Annex 2 (Determination of the LOQ for Copper in Substitute Ocean
Water for the Analytical Method) of ASTM D 6442-06, a recovery of (100 ± 10) % for artificial seawater
recovery check standards containing copper ions at concentrations of 50 µg/l and 200 µg/l, and a recovery of
(100 ± 15) % for an artificial seawater recovery check standard containing copper ions at a concentration of
10 µg/l.
Clean all non-disposable or re-used apparatus by immersion in concentrated hydrochloric acid (6.1.1) for at
least 30 min, or dilute acid (6.1.2) for at least 6 h, to remove all traces of biocide. Rinse thoroughly with
grade 2 water (6.4).
NOTE Some biocides have a strong tendency to adsorb on certain glass or plastic surfaces, which necessitates the
above precautions.
Operate the spectrometer or other apparatus in accordance with the manufacturer’s instructions.
8.2
...


NORME ISO
INTERNATIONALE 15181-2
Deuxième édition
2007-06-01
Peintures et vernis — Détermination du
taux de lixiviation des biocides contenus
dans les peintures antisalissures —
Partie 2:
Détermination de la concentration
ionique du cuivre dans l'extrait et calcul
du taux de lixiviation
Paints and varnishes — Determination of release rate of biocides from
antifouling paints —
Part 2: Determination of copper-ion concentration in the extract and
calculation of the release rate

Numéro de référence
©
ISO 2007
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.

DOCUMENT PROTÉGÉ PAR COPYRIGHT

©  ISO 2007
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2007 – Tous droits réservés

Sommaire Page
Avant-propos. iv
Introduction . v
1 Domaine d'application. 1
2 Références normatives. 1
3 Principe. 1
4 Informations supplémentaires exigées pour le mode opératoire d'extraction du cuivre . 2
5 Appareillage. 2
6 Réactifs et matériaux. 2
7 Échantillons d'essai. 2
8 Mode opératoire. 3
9 Calculs et expression des résultats. 4
10 Fidélité. 7
11 Rapport d'essai . 7
Annexe A (normative) Informations supplémentaires exigées pour le mode opératoire
d'extraction du cuivre. 9
Bibliographie . 10

Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 15181-2 a été élaborée par le comité technique ISO/TC 35, Peintures et vernis, sous-comité SC 9,
Méthodes générales d'essais des peintures et vernis.
Cette deuxième édition annule et remplace la première édition (ISO 15181-2:2000), dont les Articles 5.1, 5.8.4,
6.5, 6.3, 6.4 et 7, et les Annexes A et B ont fait l'objet d'une révision technique.
L'ISO 15181 comprend les parties suivantes, présentées sous le titre général Peintures et vernis —
Détermination du taux de lixiviation des biocides contenus dans les peintures antisalissures:
⎯ Partie 1: Méthode générale d'extraction des biocides
⎯ Partie 2: Détermination de la concentration ionique du cuivre dans l'extrait et calcul du taux de lixiviation
⎯ Partie 3: Calcul du taux de lixiviation de l'éthylène-bis(dithiocarbamate) de zinc (zinèbe) par détermination
de la concentration de l'éthylènethiourée dans l'extrait
⎯ Partie 4: Détermination de la concentration de la pyridine-triphénylborane (PTPB) dans l'extrait et calcul
du taux de lixiviation
⎯ Partie 5: Calcul du taux de lixiviation du tolylfluanide et du dichlofluanide par détermination de la
concentration du diméthyl-tolylsulfamide (DMST) et du diméthyl-phénylsulfamide (DMSA) dans l'extrait

iv © ISO 2007 – Tous droits réservés

Introduction
Dans des conditions normales de température, de salinité et de pH et aux faibles concentrations en biocide
contenues dans un milieu d'eau de mer synthétique, la méthode décrite dans la présente partie de
l'ISO 15181 permet de déterminer une valeur reproductible du taux de lixiviation dans des conditions de
laboratoire spécifiées et peut être utilisée pour l'assurance de la qualité et le choix des matériaux. Le taux réel
de lixiviation de biocides contenus dans des peintures antisalissures des coques de navires dépendra
toutefois de nombreux facteurs, tels que les conditions opérationnelles de service des navires, la durée de
service, les conditions de mouillage, l'état de la peinture, ainsi que la température, la salinité, le pH, les
polluants et la flore microbienne dans une zone donnée.
Les résultats de cet essai ne reflètent pas les taux de lixiviation de biocides de produits antisalissures dans
lenvironnement. Les résultats de la présente méthode d'essai ne sappliquent pas à une utilisation directe
dans le cadre des procédures d'évaluation des risques liés à lenvironnement, destimation de la contrainte
environnementale ou d'établissement de limites de taux de lixiviation à des fins réglementaires. Si lon
compare les taux de lixiviation du cuivre et des composés organostanniques obtenus par des mesures
directes ou indirectes du taux de lixiviation du cuivre des coques de navire et par des mesures effectuées sur
des panneaux exposés dans des ports, toutes les données disponibles indiquent que les résultats de la
présente méthode d'essai générique surestiment de manière significative le taux de lixiviation de biocides
dans les conditions de service. Les résultats publiés démontrent que les résultats de la présente méthode
présentent généralement des valeurs supérieures d'un facteur d'environ 10, ou plus, aux mesures directes
effectuées sur site des taux de lixiviation du cuivre et des composés organostanniques des coques de navire
[1, 2]
en service pour plusieurs revêtements antisalissures du commerce . Un rapport similaire est escompté
pour d'autres biocides. Des estimations réalistes du taux de lixiviation de biocides d'une coque de navire dans
des conditions de service ne peuvent être obtenues avec la présente méthode d'essai que lorsque cette
différence est prise en compte.
Lorsque les résultats de la présente méthode d'essai sont utilisés dans le cadre des procédures d'évaluation
des risques liés à l'environnement, d'estimation de la contrainte environnementale ou d'établissement de
limites de taux de lixiviation à des fins réglementaires, il est vivement recommandé de tenir compte du rapport
entre les taux de lixiviation de laboratoire et les quantités réelles relarguées dans l'environnement afin
d'obtenir une approximation plus précise du taux de lixiviation de biocides des revêtements antisalissures
[2]
dans des conditions réelles. Ceci peut être réalisé en appliquant les facteurs de correction appropriés .

NORME INTERNATIONALE ISO 15181-2:2007(F)

Peintures et vernis — Détermination du taux de lixiviation
des biocides contenus dans les peintures antisalissures —
Partie 2:
Détermination de la concentration ionique du cuivre dans
l'extrait et calcul du taux de lixiviation
1 Domaine d'application
La présente partie de l'ISO 15181 spécifie l'appareillage et l'analyse technique permettant de déterminer la
teneur en biocide à base de cuivre relargué par une peinture antisalissures dans l'eau de mer synthétique
conformément au mode opératoire donné dans l'ISO 15181-1.
Elle détermine la concentration en ions cuivre et donne le calcul final du taux de lixiviation de cuivre dans les
conditions spécifiées de laboratoire. La présente partie de l'ISO 15181 est destinée, de façon générale, à
permettre de déterminer simultanément les ions cuivre et d'autres biocides susceptibles d'être relargués par
une peinture antisalissures donnée à partir de l'analyse de sous-échantillons séparés dextrait d'eau de mer
synthétique prélevés conformément au mode opératoire donné dans l'ISO 15181-1 et analysés conformément
aux modes opératoires donnés dans les autres parties de la présente Norme internationale.
Conjointement à l'ISO 15181-1, les limites pratiques de quantification des taux de lixiviation par la présente
–2 –1 –2 –1
méthode sont comprises entre 1,8 µg·cm ·d et 500 µg·cm ·d . La quantification de taux de lixiviation
inférieurs à cette plage nécessite d'appliquer une méthode danalyse dont la limite de quantification du cuivre
dans leau de mer synthétique est inférieure à celle spécifiée en 5.1.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du
document de référence s'applique (y compris les éventuels amendements).
ISO 3696, Eau pour laboratoire à usage analytique — Spécification et méthodes d'essai
ISO 15181-1:2007, Peintures et vernis — Détermination du taux de lixiviation des biocides contenus dans les
peintures antisalissures — Partie 1: Méthode générale d'extraction des biocides
ASTM D 6442-06, Standard Test Method for Determination of Copper Release Rate from Antifouling Coatings
in Substitute Ocean Water
3 Principe
La concentration en ions cuivre relargués dans l'eau de mer synthétique selon le mode opératoire donné dans
l'ISO 15181-1 est déterminée au moyen d'un spectromètre d'absorption atomique, ou par toute autre méthode
analytique, à condition qu'elle fasse preuve d'une limite de quantification du cuivre dans l'eau de mer
synthétique inférieure ou égale à 10 µg/l. Le taux de lixiviation de biocides est alors exprimé en cuivre métal.
4 Informations supplémentaires exigées pour le mode opératoire d'extraction
du cuivre
Les informations supplémentaires exigées pour utiliser le mode opératoire général d'extraction, décrit dans
l'ISO 15181-1, pour les biocides à base de cuivre, sont données dans l'Annexe A.
5 Appareillage
5.1 Spectromètre d'absorption atomique, si possible doté d'un échantillonneur automatique, ou tout
autre instrument approprié dont la limite de quantification du cuivre dans l'eau de mer synthétique est
inférieure ou égale à 10 µg/l. La limite de quantification (LOQ) doit être déterminée par le mode opératoire
donné dans l'Annexe 2 (Détermination of the LOQ for Copper in Substitute Ocean Water for the Analytical
Method) de l'ASTM D 6442-06.
5.2 Agitateur mécanique, muni de supports appropriés.
5.3 Distributeurs, automatique ou à répétition, pour les réactifs.
5.4 Pipettes, de volume approprié avec embouts jetables.
5.5 Fioles jaugées, de volume approprié.
5.6 Tubes à échantillons, de capacité appropriée, munis de fermetures à vis, en matériau inerte.
NOTE Le polycarbonate, le polypropylène ou le verre borosilicaté sont généralement considérés comme étant des
matériaux appropriés.
6 Réactifs et matériaux
Il convient de consulter les données techniques de sécurité des matériaux des fournisseurs pour obtenir des
informations détaillées sur tout risque associé aux réactifs énumérés ci-dessous et il convient d'évaluer les
risques associés à leur utilisation. Il convient par conséquent d'utiliser des vêtements et des équipements de
protection appropriés.
Sauf spécification contraire, n'utiliser que des réactifs de qualité analytique reconnue.
6.1 Réactifs de nettoyage.
Pour nettoyer tous les équipements, utiliser l'un des réactifs de nettoyage suivants:
6.1.1 Acide chlorhydrique, en solution aqueuse concentrée, 37 % en masse.
6.1.2 Acide chlorhydrique, en solution aqueuse, 10 % en volume.
6.2 Acide nitrique, concentré (ρ environ 1,42 g/ml).
6.3 Eau de mer synthétique, comme défini dans l'ISO 15181-1.
6.4 Eau, de qualité analytique 2 conformément aux exigences de l'ISO 3696.
7 Échantillons d'essai
Extraits prélevés des récipients de mesure du taux de lixiviation comme décrit dans l'ISO 15181-1.
2 © ISO 2007 – Tous droits réservés

8 Mode opératoire
8.1 Généralités
Effectuer toutes les déterminations sur l'extrait en utilisant la méthode suivante. Il est admis d'utiliser une
autre méthode d'analyse à condition que sa limite de quantification des ions cuivre dans l'eau de mer
synthétique soit inférieure ou égale à 10 µg/l, déterminée par le mode opératoire donné dans l'Annexe 2
(Détermination of the LOQ for Copper in Substitute Ocean Water for the Analytical Method) de
l'ASTM D 6442-06, pour une récupération de (100 ± 10) % pour des échantillons témoins de récupération
d'étalonnage d'eau de mer synthétique contenant des concentrations en ions cuivre de 50 µg/l et 200 µg/l, et
une récupération de (100 ± 15) % pour un échantillon témoin de récupération d'étalonnage d'eau de mer
synthétique contenant des concentrations en ions cuivre de 10 µg/l.
Nettoyer tous les appareils non jetables ou réutilisés en les immergeant dans de l'acide chlorhydrique (6.1.1)
concentré pendant au moins 30 min, ou dans l'acide dilué (6.1.2) pendant au moins 6 h pour éliminer toute
trace de biocide. Rincer soigneusement à l'aide d'une eau de qualité analytique 2 (6.4).
NOTE Certains types de biocides ont fortement tendance à sadsorber sur certaines surfaces en verre ou en
plastique, ce qui nécessite de prendre les précautions ci-dessus.
Utiliser le spectr
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.