Plastics - Determination of thermal conductivity and thermal diffusivity - Part 4: Light flash method

This document specifies a method for the determination of the thermal diffusivity of a thin solid disc of plastics in the thickness direction by the light flash method. This method is based upon the measurement of the temperature rise at the rear face of the thin-disc specimen produced by a short energy pulse on the front face. The method is applicable to homogeneous solid plastics as well as composites having an isotropic or orthotropic structure. In general, it covers materials having a thermal diffusivity, α, in the range 1 × 10−7 m2⋅s−1 α −4 m2⋅s−1. Measurements can be carried out in gaseous and vacuum environments over a temperature range from −100 °C to +400 °C. NOTE For inhomogeneous specimens, the measured values can be specimen thickness dependent.

Plastiques — Détermination de la conductivité thermique et de la diffusivité thermique — Partie 4: Méthode flash lumineux

Le présent document spécifie une méthode de détermination de la diffusivité thermique d’un disque plein mince en plastique suivant la direction de l’épaisseur par la méthode flash lumineux. Cette méthode est fondée sur le mesurage de l’élévation de température sur la face arrière d’une éprouvette sous forme de disque mince due à une courte impulsion énergétique sur la face avant. La méthode est applicable aux plastiques compacts homogènes ou composites présentant une structure isotrope ou orthotrope. En général, cela inclut les matériaux ayant une diffusivité thermique, α, comprise dans la plage 1 × 10−7 m2⋅s−1 α −4 m2⋅s−1. Les mesurages peuvent être effectués en environnements gazeux et sous vide sur une plage de températures comprises entre −100 °C et +400 °C. NOTE Pour des éprouvettes non homogènes, les valeurs mesurées peuvent dépendre de l’épaisseur de l’éprouvette.

General Information

Status
Published
Publication Date
10-Jan-2024
Current Stage
6060 - International Standard published
Start Date
11-Jan-2024
Due Date
01-Dec-2024
Completion Date
11-Jan-2024

Relations

Effective Date
10-Dec-2022
Effective Date
10-Dec-2022

Overview

ISO 22007-4:2024 specifies the light flash method for determining the thermal diffusivity of thin plastic discs in the thickness direction. The method measures the transient temperature rise at the rear face of a specimen after a short, uniform energy pulse on the front face. It applies to homogeneous plastics and composites with isotropic or orthotropic structure and supports measurements from −100 °C to +400 °C for materials with thermal diffusivity in the order of 1×10−7 to 1×10−4 m2·s−1. The standard replaces the term “laser flash” with the broader “light flash” and includes requirements for apparatus, specimen preparation, calibration, data analysis and uncertainty assessment.

Key topics and technical requirements

  • Principle: Record the rear-face thermogram produced by a short light pulse and derive thermal diffusivity by comparison with theoretical models (see Clause 9 and Annex B).
  • Specimen: Thin disc geometry (typical diameters 5–20 mm; thickness commonly 0.5–3 mm), flat parallel faces, diameter-to-thickness ratio > 3:1; thickness measured to ±5 µm (resolution ±1 µm).
  • Apparatus: Furnace or climatic chamber with optical windows, flash source (laser or flash tube), pulse detector, IR transient detector, specimen holder and data acquisition/analysis unit.
  • Detector & acquisition: IR detector sensitivity ~5 mK, linear over ≥3 K, frequency response faster than 10 kHz; record thermogram with >1 000 data points and sampling rate adequate relative to the half-rise time.
  • Pulse & heating: Pulse duration < 1 ms; rear-face temperature rise normally ≤ 3 K to avoid nonlinear effects.
  • Environment & temperature control: Tests may be performed in gas or vacuum (vacuum minimizes convection); chamber stability ±0.5 K and temperature measurement accuracy ~±0.5 K.
  • Quality controls: Calibration and verification routines, specified specimen conditioning (ISO 291), uncertainty estimation (GUM/ISO/IEC Guide 98-3), and reporting requirements.

Applications and users

  • Who uses it: Materials scientists, polymer engineers, quality control and testing laboratories, R&D teams, and standards bodies assessing thermal properties of plastics and polymer composites.
  • Practical applications:
    • Thermal characterization for electronics packaging, automotive and aerospace components
    • Material selection for insulation, heat sinks, and thermal interface materials
    • Verification of processing effects (orientation, anisotropy) on thermal behavior
    • Inputs for thermal modeling and simulation (thermal diffusivity → conductivity via density and specific heat)

Related standards

  • ISO 22007-1 - General principles for determination of thermal conductivity and diffusivity
  • ISO 291 - Conditioning and testing atmospheres for plastics
  • ISO 527-1 - Tensile properties (relevant for specimen preparation)
  • ISO/IEC Guide 98-3 (GUM) - Guide to the expression of uncertainty in measurement

Keywords: ISO 22007-4:2024, light flash method, thermal diffusivity, thermal conductivity, plastics testing, polymer thermal properties.

Standard

ISO 22007-4:2024 - Plastics — Determination of thermal conductivity and thermal diffusivity — Part 4: Light flash method Released:11. 01. 2024

English language
16 pages
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 22007-4:2024 - Plastiques — Détermination de la conductivité thermique et de la diffusivité thermique — Partie 4: Méthode flash lumineux Released:11. 01. 2024

French language
18 pages
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

ISO 22007-4:2024 is a standard published by the International Organization for Standardization (ISO). Its full title is "Plastics - Determination of thermal conductivity and thermal diffusivity - Part 4: Light flash method". This standard covers: This document specifies a method for the determination of the thermal diffusivity of a thin solid disc of plastics in the thickness direction by the light flash method. This method is based upon the measurement of the temperature rise at the rear face of the thin-disc specimen produced by a short energy pulse on the front face. The method is applicable to homogeneous solid plastics as well as composites having an isotropic or orthotropic structure. In general, it covers materials having a thermal diffusivity, α, in the range 1 × 10−7 m2⋅s−1 α −4 m2⋅s−1. Measurements can be carried out in gaseous and vacuum environments over a temperature range from −100 °C to +400 °C. NOTE For inhomogeneous specimens, the measured values can be specimen thickness dependent.

This document specifies a method for the determination of the thermal diffusivity of a thin solid disc of plastics in the thickness direction by the light flash method. This method is based upon the measurement of the temperature rise at the rear face of the thin-disc specimen produced by a short energy pulse on the front face. The method is applicable to homogeneous solid plastics as well as composites having an isotropic or orthotropic structure. In general, it covers materials having a thermal diffusivity, α, in the range 1 × 10−7 m2⋅s−1 α −4 m2⋅s−1. Measurements can be carried out in gaseous and vacuum environments over a temperature range from −100 °C to +400 °C. NOTE For inhomogeneous specimens, the measured values can be specimen thickness dependent.

ISO 22007-4:2024 is classified under the following ICS (International Classification for Standards) categories: 83.080.01 - Plastics in general. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 22007-4:2024 has the following relationships with other standards: It is inter standard links to ISO 22507:2022, ISO 22007-4:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase ISO 22007-4:2024 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of ISO standards.

Standards Content (Sample)


International
Standard
ISO 22007-4
Third edition
Plastics — Determination of
2024-01
thermal conductivity and thermal
diffusivity —
Part 4:
Light flash method
Plastiques — Détermination de la conductivité thermique et de la
diffusivité thermique —
Partie 4: Méthode flash lumineux
Reference number
© ISO 2024
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Apparatus . 2
5.1 General .2
5.2 Furnace or climatic chamber .2
5.3 Flash source .4
5.4 Transient detectors .4
5.5 Thickness measurement device .5
6 Test specimen . 5
6.1 Shape and dimension of the specimen .5
6.2 Preparation and conditioning of test specimen .5
6.3 Coating the specimen .5
7 Calibration and verification . . 6
7.1 Calibration of apparatus .6
7.2 Verification of apparatus .6
8 Procedure . 6
9 Data analysis . 7
10 Uncertainty . 9
11 Test report . 9
Annex A (informative) Correction for finite pulse duration . 10
Annex B (informative) Alternative methods of calculating thermal diffusivity .11
Annex C (normative) Samples and test specimen preparation for injection mouldable
thermoplastics and thermosets.12
Bibliography .16

iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 5, Physical-
chemical properties, in collaboration with the European Committee for Standardization (CEN) Technical
Committee CEN/TC 249, Plastics, in accordance with the Agreement on technical cooperation between ISO
and CEN (Vienna Agreement).
This third edition cancels and replaces the second edition (ISO 22007-4:2017), which has been technically
revised.
The main changes are as follows:
— the term laser flash has been replaced by the more general term light flash.
A list of all parts in the ISO 22007 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.

iv
International Standard ISO 22007-4:2024(en)
Plastics — Determination of thermal conductivity and
thermal diffusivity —
Part 4:
Light flash method
1 Scope
This document specifies a method for the determination of the thermal diffusivity of a thin solid disc of
plastics in the thickness direction by the light flash method. This method is based upon the measurement of
the temperature rise at the rear face of the thin-disc specimen produced by a short energy pulse on the front
face.
The method is applicable to homogeneous solid plastics as well as composites having an isotropic
or orthotropic structure. In general, it covers materials having a thermal diffusivity, α, in the range
−7 2 −1 −4 2 −1
1 × 10 m ⋅s < α < 1 × 10 m ⋅s . Measurements can be carried out in gaseous and vacuum environments
over a temperature range from −100 °C to +400 °C.
NOTE For inhomogeneous specimens, the measured values can be specimen thickness dependent.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO/IEC Guide 98-3, Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in
me a s ur ement (GUM: 1995)
ISO 291, Plastics — Standard atmospheres for conditioning and testing
ISO 527-1, Plastics — Determination of tensile properties — Part 1: General principles
ISO 22007-1, Plastics — Determination of thermal conductivity and thermal diffusivity — Part 1: General
principles
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 22007-1 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1
pulse width
t
p
duration for which the light pulse intensity is larger than half of its maximum value
Note 1 to entry: It is expressed in seconds (s).

3.2
time origin
t
start of the light pulse
Note 1 to entry: It is expressed in seconds (s).
3.3
maximum temperature rise
ΔT
max
difference between the maximum temperature reached by the rear face of the specimen after the light pulse
has passed and its steady temperature before the pulse
Note 1 to entry: It is expressed in kelvins (K).
3.4
half-rise time
t
1/2
time from the time origin (3.2) until the rear-face temperature increases by one-half of ΔT
max
Note 1 to entry: It is expressed in seconds (s).
3.5
thermogram
temperature versus time curve for the rear face of the specimen
3.6
thickness
d
dimension of the test specimen in the direction of heat transfer measurement
Note 1 to entry: It is expressed in metres (m).
4 Principle
One side of a flat-sheet test specimen is subjected to an energy pulse which has a very short duration
compared with the half-rise time (see 6.1) and a uniform spatial energy distribution. The transient
temperature rise on the opposite face (rear face) is recorded as a function of time (see Figure 1). The thermal
diffusivity is obtained by comparing the experimental thermogram with a theoretical model (see Clause 9
and Annex B).
5 Apparatus
5.1 General
The apparatus shall be designed to obtain the thermal diffusivity as described in Clause 4 and shall consist
of the following main components as shown in Figure 2. These are the furnace or climatic chamber with a
specimen holder and temperature measurement device (e.g. thermocouple), the flash source (e.g. laser), the
pulse detector, the transient detector (IR detector) and the control, data acquisition and analysis unit.
5.2 Furnace or climatic chamber
The furnace or climatic chamber shall meet the following requirements.
a) The temperature range shall be appropriate to the range of materials to be studied. Depending on
the range of temperature, the specimen is maintained at a constant temperature by a cryostat or by a
furnace.
b) It shall be capable of maintaining the test temperature constant to within ±0,5 K or less for at least
30 min.
c) The temperature measurement device shall be capable of measuring the furnace or climatic chamber
temperature with a resolution of ±0,1 K and an accuracy of ±0,5 K or better.
d) The furnace or climatic chamber shall be fitted with two windows, one transparent to the pulse
radiation and the other transparent to the working wavelength range of the IR detector.
e) If required, the test environment shall be vacuum or inert-gas atmosphere to avoid oxidative degradation
during heating and testing of the specimen. For cryoscopic measurements, care shall be taken to avoid
water condensation on the windows.
NOTE Measurement under vacuum will eliminate convection effects.
The specimen holder shall be designed to minimize thermal contact with the specimen and to suppress stray
light transmitted from the light beam to the IR detector.
The test temperature shall be measured using a calibrated temperature measurement device that is
preferably in contact with the specimen or the specimen holder but at least within 1 mm of the specimen
holder.
The temperature measurement device shall be designed so as not to significantly disturb the temperature
field generated in the specimen by the light pulse.
Key
t time
ΔT temperature rise
a
Baseline.
b
Transient-rise period.
c
Cooling period.
Figure 1 — Example of thermogram

Key
1 flash source
2 pulse detector
3 specimen
4 furnace or climatic chamber
5 temperature measurement device
6 windows
7 transient detector
Figure 2 — Schematic diagram of light flash set-up for measuring thermal diffusivity
5.3 Flash source
The energy level of the flash source shall produce a temperature rise not exceeding 3 K at the rear face of the
specimen.
The spatial energy distribution of the pulse heating shall be as uniform as possible over the front face of the
specimen.
The pulse duration shall be shorter than 1 ms.
The heat pulse source may be a laser or a flash tube.
A photodiode can be used to determine the duration and form of the pulse and the time origin.
5.4 Transient detectors
The transient temperature rise at the rear face of the specimen shall be measured with an IR detector. The
transient detector shall be able to detect a variation of 5 mK in the specimen rear face temperature. Its
response shall be linear with temperature over a temperature range of at least 3 K.
The frequency response of the detector and its associated electronics (amplifiers, analogue/digital
converters, etc.) shall be faster than 10 kHz. If electronic filters are used, they shall meet the requirements
defined above and shall not decrease the accuracy of temperature measurement, otherwise they could
distort the shape of the temperature-time curve.
NOTE The choice of IR detector depends also on the temperature range. For the range −100 °C to +400 °C,
photovoltaic or photoconductor detectors can be used.

The temperature of the rear face, or a quantity directly proportional to it (e.g. voltage), shall be measured
and recorded continuously over the duration of the test. The data acquisition system, which may be analogue
or digital, shall be able to sample more than 1 000 data points on the thermogram with a sampling frequency
−5
higher than 100/t . The accuracy of the time base shall be better than ±1 × 10 s.
1/2
5.5 Thickness measurement device
The specimen thickness shall be measured with an accuracy of ±5 µm by a calibrated thickness measurement
device having a resolution of ±1 µm. For soft materials, a micrometer with reproducibly low compression is
required.
6 Test specimen
6.1 Shape and dimension of the specimen
The specimen shall be a thin disc. The specimen diameter is usually from 5 mm to 20 mm. The specimen
thickness shall be chosen according to the pulse width and the thermal diffusivity of the material. It shall
be selected such that the pulse width is less than 0,01 of the half-rise time. Typically, the thickness will
be between 0,5 mm and 3 mm. The aspect ratio of the specimen shall be chosen such that 2D effects are
negligible during the test. The ratio of the diameter to the thickness shall be larger than 3:1.
The faces shall be flat and parallel. Any variation in the thickness of the specimen should preferably be less
than 1 % of the mean thickness. The effect of greater non-uniformity can be estimated in the measurement
uncertainty.
6.2 Preparation and conditioning of test specimen
The test specimen shall be representative of the material being examined and shall be prepared and handled
with care. If the specimen is taken from sample pieces by cutting, care shall be taken to prevent heating,
changes in molecular orientation or any other effect that can alter the sample properties.
The preparation of specimens of oriented, anisotropic samples shall be done as specified in Annex C.
The test specimen shall be conditioned prior to the measurement as specified in the relevant material
standard or by a method agreed between the parties involved. Unless other conditions are specified, the
specimen shall be conditioned in accordance with ISO 291.
NOTE Depending on the material and its thermal history, the method of test specimen preparation can be crucial
to the consistency of the results and their significance.
6.3 Coating the specimen
Specimens which are not opaque to the light radiation at the wavelength used shall be coated with an
appropriate coating (a metal or graphite coating, for example) to prevent penetration of the light beam into
the specimen. The influence of the coating on the heat transfer shall be negligible (i.e. it shall have a high
diffusivity and low thickness in comparison with the specimen). The total thickness of the coating shall be
chosen such that the half-rise time for the coating alone is less than 2 % of the total half-rise time for the
specimen.
NOTE 1 The half-rise time, t , for the coating can be simply calculated from its thickness, d, and thermal diffusivity,
1/2
α, using Formula (1), a rearranged form of Formula (B.1):
d
t =0,138 79 (1)
12/
α
NOTE 2 Both sides of the specimen can be coated with a thin opaque layer as mentioned above to optimize the
absorption of the energy pulse and the emission of thermal radiation.

7 Calibration and verification
7.1 Calibration of apparatus
The light flash technique for the determination of the thermal diffusivity is an absolute method which allows
the user to perform measurements that are directly traceable to primary SI units (such as temperature,
time, length and voltage). All elements of the light flash apparatus shall be calibrated separately, as follows.
— Calibrate the micrometer used to measure the specimen thickness.
— Calibrate the temperature measurement device used to measure the steady-state temperature of the
specimen.
— Calibrate the time base and the voltage of the data acquisition system used to measure the signal coming
from the IR detector.
— Calibrate the IR detector in order to be able to observe the transient temperature change at the rear
face of the specimen rather than the transient spectral irradiance. Perform this calibration mainly
for temperatures lower than 200 °C where nonlinear behaviour of the output temperature cannot be
[1]
neglected (see ISO 18755 ). If this calibration is not possible (e.g. because the IR detector is inaccessible
or due to differences between the optical paths of the IR detector calibration configuration and the
thermal-diffusivity measurement configuration), the effects of nonlinearity have to be taken into account
in the uncertainty of measurement.
7.2 Verification of apparatus
The apparatus should preferably be
...


Norme
internationale
ISO 22007-4
Troisième édition
Plastiques — Détermination de
2024-01
la conductivité thermique et de la
diffusivité thermique —
Partie 4:
Méthode flash lumineux
Plastics — Determination of thermal conductivity and thermal
diffusivity —
Part 4: Light flash method
Numéro de référence
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2024
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii
Sommaire Page
Avant-propos .iv
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Principe. 2
5 Appareillage . 2
5.1 Généralités .2
5.2 Four ou enceinte climatique .3
5.3 Source flash .5
5.4 Détecteurs transitoires . .5
5.5 Dispositif de mesure de l’épaisseur.6
6 Éprouvette . 6
6.1 Forme et dimension de l’éprouvette .6
6.2 Préparation et conditionnement de l’éprouvette .6
6.3 Revêtement de l’éprouvette .6
7 Étalonnage et vérification . 7
7.1 Étalonnage de l’appareillage.7
7.2 Vérification de l’appareillage .7
8 Mode opératoire . 8
9 Analyse des données . 9
10 Incertitude . 10
11 Rapport d’essai .10
Annexe A (informative) Correction relative à l’effet d’impulsion finie .12
Annexe B (informative) Autres méthodes de calcul de la diffusivité thermique .13
Annexe C (normative) Préparation des échantillons et de l’éprouvette pour les thermoplastiques
moulables par injection et les plastiques thermodurcis . 14
Bibliographie .18

iii
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux
de normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général
confiée aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire
partie du comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (IEC) en ce qui concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier, de prendre note des différents
critères d'approbation requis pour les différents types de documents ISO. Le présent document a
été rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir
www.iso.org/directives).
L’ISO attire l’attention sur le fait que la mise en application du présent document peut entraîner l’utilisation
d’un ou de plusieurs brevets. L’ISO ne prend pas position quant à la preuve, à la validité et à l’applicabilité de
tout droit de brevet revendiqué à cet égard. À la date de publication du présent document, l’ISO n'avait pas
reçu notification qu’un ou plusieurs brevets pouvaient être nécessaires à sa mise en application. Toutefois,
il y a lieu d’avertir les responsables de la mise en application du présent document que des informations
plus récentes sont susceptibles de figurer dans la base de données de brevets, disponible à l'adresse
www.iso.org/brevets. L’ISO ne saurait être tenue pour responsable de ne pas avoir identifié tout ou partie de
tels droits de propriété.
Les appellations commerciales éventuellement mentionnées dans le présent document sont données pour
information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l'ISO liés à l'évaluation de la conformité, ou pour toute information au sujet de l'adhésion de
l'ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles techniques au
commerce (OTC), voir www.iso.org/avant-propos.
Le présent document a été élaboré par le comité technique ISO/TC 61, Plastiques, sous-comité SC 5, Propriété
physicochimiques, en collaboration avec le comité technique CEN/TC 249, Plastiques, du Comité européen de
normalisation (CEN) conformément à l’Accord de coopération technique entre l’ISO et le CEN (Accord de
Vienne).
Cette troisième édition annule et remplace la deuxième édition (ISO 22007-4:2017), qui a fait l’objet d’une
révision technique.
Les principales modifications sont les suivantes:
— le terme flash laser a été remplacé par le terme flash lumineux qui est plus général.
Une liste de toutes les parties de la série ISO 22007 se trouve sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes se
trouve à l’adresse www.iso.org/fr/members.html.

iv
Norme internationale ISO 22007-4:2024(fr)
Plastiques — Détermination de la conductivité thermique et
de la diffusivité thermique —
Partie 4:
Méthode flash lumineux
1 Domaine d’application
Le présent document spécifie une méthode de détermination de la diffusivité thermique d’un disque plein
mince en plastique suivant la direction de l’épaisseur par la méthode flash lumineux. Cette méthode est
fondée sur le mesurage de l’élévation de température sur la face arrière d’une éprouvette sous forme de
disque mince due à une courte impulsion énergétique sur la face avant.
La méthode est applicable aux plastiques compacts homogènes ou composites présentant une structure
isotrope ou orthotrope. En général, cela inclut les matériaux ayant une diffusivité thermique, α, comprise
−7 2 −1 −4 2 −1
dans la plage 1 × 10 m ⋅s < α < 1 × 10 m ⋅s . Les mesurages peuvent être effectués en environnements
gazeux et sous vide sur une plage de températures comprises entre −100 °C et +400 °C.
NOTE Pour des éprouvettes non homogènes, les valeurs mesurées peuvent dépendre de l’épaisseur de l’éprouvette.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur
contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour
les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels
amendements).
Guide ISO/IEC 98-3, Incertitude de mesure — Partie 3: Guide pour l’expression de l’incertitude de mesure (GUM:
1995)
ISO 291, Plastiques — Atmosphères normales de conditionnement et d'essai
ISO 527-1, Plastiques — Détermination des propriétés en traction — Partie 1: Principes généraux
ISO 22007-1, Plastiques — Détermination de la conductivité thermique et de la diffusivité thermique — Partie 1:
Principes généraux
3 Termes et définitions
Pour les besoins du présent document, les termes et les définitions de l’ISO 22007-1 ainsi que les suivants
s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation,
consultables aux adresses suivantes:
— ISO Online browsing platform: disponible à l’adresse https:// www .iso .org/ obp
— IEC Electropedia: disponible à l’adresse https:// www .electropedia .org/

3.1
largeur d’impulsion
t
p
durée pendant laquelle l’intensité de l’impulsion lumineuse est plus grande que la moitié de sa valeur
maximale
Note 1 à l'article: Elle est exprimée en secondes (s).
3.2
origine de temps
t
début de l’impulsion lumineuse
Note 1 à l'article: Elle est exprimée en secondes (s).
3.3
élévation maximale de température
ΔT
max
différence entre la température maximale atteinte par la face arrière de l’éprouvette après l’impulsion
lumineuse et sa température constante avant l’impulsion
Note 1 à l'article: Elle est exprimée en kelvins (K).
3.4
temps de mi-élévation
t
1/2
temps écoulé depuis l’origine de temps (3.2) jusqu’à ce que la température de la face arrière atteigne la moitié
de ∆T
max
Note 1 à l'article: Il est exprimé en secondes (s).
3.5
thermogramme
courbe de la température en fonction du temps de la face arrière de l’éprouvette
3.6
épaisseur
d
dimension de l’éprouvette dans la direction de mesure du transfert de chaleur
Note 1 à l'article: Elle est exprimée en mètres (m).
4 Principe
L’une des faces d’une éprouvette constituée par une plaque plane est soumise à une impulsion énergétique
d’une très courte durée comparée au temps de mi-élévation (voir 6.1) et d’une distribution spatiale d’énergie
uniforme. L’élévation transitoire de température sur la face opposée (face arrière) est enregistrée en
fonction du temps (voir la Figure 1). La diffusivité thermique est obtenue en comparant le thermogramme
expérimental à un modèle théorique (voir l’Article 9 et l’Annexe B).
5 Appareillage
5.1 Généralités
Les appareils doivent être conçus pour obtenir la diffusivité thermique comme décrit dans l’Article 4 et
doivent comprendre les principaux composants suivants, tels qu’illustrés à la Figure 2. Ces composants
sont le four ou l’enceinte climatique avec un porte-éprouvette et un dispositif de mesure de la température
(par exemple un thermocouple), la source flash (par exemple laser), le détecteur d’impulsion, le détecteur
transitoire (détecteur IR) et les unités de contrôle, d’acquisition de données et d’analyse.

5.2 Four ou enceinte climatique
Le four ou l’enceinte climatique doit satisfaire aux exigences suivantes:
a) La plage de températures doit être appropriée à la plage des matériaux à étudier. En fonction de la plage
de températures, l’éprouvette est maintenue à une température constante au moyen d’un cryostat ou
d’un four.
b) Le four ou l’enceinte climatique doit être capable de maintenir une température d’essai constante
à ±0,5 K près, ou mieux, pendant au moins 30 min.
c) Le dispositif de mesure de la température doit être capable de mesurer la température du four ou de
l'enceinte climatique avec une résolution de ±0,1 K et avec une exactitude de ±0,5 K ou mieux.
d) Le four ou l'enceinte climatique doit être équipé de deux fenêtres, dont l’une doit être transparente au
rayonnement par impulsion et l’autre doit être transparente au rayonnement dans la plage de longueur
d’ondes de fonctionnement du détecteur IR.
e) Si nécessaire, l’environnement doit être le vide ou une atmosphère de gaz inerte afin d’éviter une
dégradation oxydative pendant le chauffage et l’essai de l’éprouvette. Dans le cas de mesurages
cryoscopiques, il convient de veiller à éviter la condensation d’eau sur les fenêtres.
NOTE Le mesurage sous vide éliminera les effets de convection.
Le porte-éprouvette doit être conçu pour réduire au minimum le contact thermique avec l’éprouvette et
supprimer toute lumière parasite transmise du faisceau lumineux vers le détecteur IR.
La température d’essai doit être mesurée en utilisant un dispositif étalonné qui doit être de préférence en
contact avec l’éprouvette ou le porte-éprouvette, ou tout au moins à 1 mm au plus du porte-éprouvette.
Le dispositif de mesure de la température doit être conçu de façon à ne pas perturber de manière significative
le champ de température généré dans l’éprouvette par l’impulsion lumineuse.

Légende
t temps
ΔT élévation de température
a
Ligne de base.
b
Période d’élévation transitoire.
c
Période de refroidissement.
Figure 1 — Exemple de thermogramme

Légende
1 source flash
2 détecteur d’impulsion
3 éprouvette
4 four ou enceinte climatique
5 dispositif de mesure de la température
6 fenêtres
7 détecteur transitoire
Figure 2 — Schéma du montage flash lumineux pour mesurer la diffusivité thermique
5.3 Source flash
Le niveau d’énergie de la source flash doit produire une élévation de température n’excédant pas 3 K sur la
face arrière de l’éprouvette.
La distribution spatiale d’énergie du chauffage par impulsion doit être aussi uniforme que possible sur la
face avant de l’éprouvette.
La durée d’impulsion doit être inférieure à 1 ms.
La source d’impulsion thermique peut être un tube laser ou un tube flash.
Une photodiode peut être utilisée pour déterminer la durée et la forme de l’impulsion et l’origine de temps.
5.4 Détecteurs transitoires
L’élévation transitoire de température sur la face arrière de l’éprouvette doit être mesurée avec un détecteur
IR. Le détecteur transitoire doit être en mesure de détecter une variation de 5 mK de la température de la
face arrière de l’éprouvette. Sa réponse doit être linéaire avec la température sur une plage de températures
d’au moins 3 K.
La réponse en fréquence du détecteur et de ses dispositifs électroniques associés (amplificateurs,
convertisseurs analogiques/numériques, etc.) doit être plus rapide que 10 kHz. Si des filtres électroniques

sont utilisés, ils doivent satisfaire aux exigences définies ci-dessus et ne doivent pas réduire l’exactitude de
mesurage de la température, au risque de déformer la forme de la courbe temps-température.
NOTE Le choix du détecteur IR dépend également de la plage de températures. Pour la plage comprise entre
−100 °C à +400 °C, des détecteurs photovoltaïques ou photoconducteurs peuvent être utilisés.
La température de la face arrière, ou une grandeur qui lui est directement proportionnelle (par exemple
la tension), doit être mesurée et enregistrée en continu pendant toute la durée de l’essai. Le système
d’acquisition de données, qui peut être analogique ou numérique, doit être en mesure d’échantillonner plus
de 1 000 points de données sur le thermogramme avec une fréquence d’échantillonnage supérieure à 100/
−5
t . L’exactitude pour la base de temps doit être meilleure que ±1 × 10 s.
1/2
5.5 Dispositif de mesure de l’épaisseur
L’épaisseur de l’éprouvette doit être mesurée à ±5 µm près avec un dispositif étalonné ayant une résolution
de ±1 µm. Pour les matériaux souples, un micromètre à compression faible et reproductible est requis.
6 Éprouvette
6.1 Forme et dimension de l’éprouvette
L’éprouvette doit être un disque mince. Le diamètre de l’éprouvette est communément compris entre 5 mm
et 20 mm. L’épaisseur de l’éprouvette doit être choisie selon la largeur d’impulsion et la diffusivité thermique
du matériau. Elle doit être choisie de sorte que la largeur d’impulsion soit inférieure à 0,01 du temps de mi-
élévation. En général, l’épaisseur est comprise entre 0,5 mm et 3 mm. Le rapport d’aspect de l’éprouvette doit
être choisi de sorte que les effets 2D soient négligeables pendant l’essai. Le rapport du diamètre à l’épaisseur
doit être supérieur à 3:1.
Les faces doivent être planes et parallèles. Il convient que toute variation de l’épaisseur de l’éprouvette soit
inférieure à 1 % de l’épaisseur moyenne. Les effets d’une non-uniformité supérieure peuvent être estimés
dans l’incertitude de mesure.
6.2 Préparation et conditionnement de l’éprouvette
L’éprouvette doit être représentative du matériau examiné et doit être préparée et manipulée avec soin. Si
l’éprouvette est prélevée par découpage à partir d’échantillons, il faut veiller à éviter tout échauffement, tout
changement d’orientation moléculaire du polymère ou tout autre effet susceptible d’altérer les propriétés de
l’échantillon.
Dans le cas d’éprouvettes anisotropes orientées, la préparation des échantillons doit être effectuée comme
spécifié à l’Annexe C.
L’éprouvette doit être conditionnée avant le mesurage, comme spécifié dans la norme de matériau
correspondante ou par une méthode convenue entre les parties impliquées. Sauf spécification contraire,
l’éprouvette doit être conditionnée conformément à l’ISO 291.
NOTE En fonction du matériau et de son historique thermique, la méthode de préparation de l’éprouvette peut se
révéler cruciale pour la cohérence des résultats et leur signification.
6.3 Revêtement de l’éprouvette
Les éprouvettes qui ne sont pas opaques à la longueur d’onde de la lumière utilisée doivent recevoir
un revêtement approprié (revêtement métallique ou graphite par exemple) pour éviter la pénétration
du faisceau lumineux dans l’éprouvette. L’influence du revêtement sur le transfert de chaleur doit être
négligeable (c’est-à-dire qu’il doit avoir une diffusivité élevée et une faible épaisseur comparées à celles de

l’éprouvette). L’épaisseur totale du revêtement doit être choisie de sorte que le temps de mi-élévation du
revêtement seul soit inférieur à 2 % du temps de mi-élévation total de l’éprouvette.
NOTE 1 Le temps de mi-élévation, t , du revêtement peut être calculé simplement à partir de son épaisseur, d, et
1/2
de sa diffusivité thermique, α, en utilisant la Formule (1), une forme modifiée de la Formule (B.1):
d
t =0,13879 (1)
12/
α
NOTE 2 Les deux faces de l’éprouvette peuvent être revêtues d’une mince couche opaque, telle que mentionnée au-
dessus, afin d’optimiser l’absorption de l’impulsion d’énergie et de l’émission du rayonnement thermique.
7 Étalonnage et vérification
7.1 Étalonnage de l’appareillage
La technique flash lumineux pour la détermination de la diffusivité thermique est une méthode absolue qui
permet à l’utilisateur d’effectuer des mesurages directement traçables par rapport aux unités SI principales
(telles que la température, le temps, la longueur, la tension). Tous les éléments du montage flash lumineux
doivent être étalonnés séparément, comme indiqué ci-après.
— Étalonner le micromètre utilisé pour mesurer l’épaisseur de l’éprouvette.
— Étalonner le dispositif de mesure de température utilisé pour mesurer l’état stationnaire de la température
de l’éprouvette.
— Étalonner la base de temps et la tension du système d’acquisition de données utilisé pour mesurer le
signal émis par le détecteur IR.
— Étalonner le détecteur IR afin de pouvoir observer la variation transitoire de température de la face arrière
de l’éprouvette au lieu de l’irradiance spectrale transitoire. Réaliser cet étalonnage principalement pour
des températures inférieures à 200 °C, pour lesquelles la dépendance non linéaire de la température
[1]
de sortie ne peut pas être négligée (voir l’ISO 18755 ). Si cet étalonnage n’est pas possible (du fait, par
exemple, de la non-accessibilité du détecteur IR ou de la différence entre les trajectoires optiques de la
configuration d’étalonnage du détecteur IR et de la configuration de mesure de la diffusivité thermique),
les effets de non-linéarité doivent être pris en compte dans l’incertitude de mesure.
7.2 Vérification de l’appareillage
Il convient de vérifier périodiquement les appareils en mesurant la diffusivité thermique d’un ou de plusieurs
matériaux de référence couvrant la plage de diffusivités thermiques des matériaux devant être soumis à
l’essai. Si les valeurs de mesure diffèrent de plus de 5 % des valeurs de référence, procéder à un nouvel
éta
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...