Dentistry - Laboratory cutters - Part 3: Carbide cutters for milling machines

ISO 7787-3:2017 specifies dimensional and other requirements for the three most commonly used carbide cutters for milling machines which are predominantly used in the dental laboratory. Other characteristics of laboratory cutters (for example, spiralled blades or cross-cut) are not covered by this document. Cutters intended for use with CAD/CAM systems are excluded from the scope of this document.

Médecine bucco-dentaire — Fraises de laboratoire — Partie 3: Fraises de laboratoire en carbure pour machines à fraiser

ISO 7787-3:2017 spécifie des exigences dimensionnelles ainsi que d'autres exigences applicables aux trois fraises en carbure pour machine à fraiser les plus communément utilisées, destinées principalement à un usage en laboratoire dentaire. Les autres caractéristiques des fraises de laboratoire (par exemple, pour les fraises à denture spiralée ou à tronçonner) ne sont pas traitées dans le présent document. Les fraises destinées à être utilisées avec des systèmes de CAO/FAO ne relèvent pas du domaine d'application du présent document.

General Information

Status
Published
Publication Date
02-May-2017
Current Stage
9093 - International Standard confirmed
Start Date
16-Sep-2022
Completion Date
13-Dec-2025

Relations

Effective Date
06-Jun-2022
Effective Date
04-Nov-2015

Overview

ISO 7787-3:2017 specifies dimensional and performance requirements for the most commonly used carbide laboratory cutters for milling machines in the dental laboratory. The standard ensures interchangeability and consistent quality of tungsten carbide cutters used for milling dental prosthetic parts. It excludes cutters intended for CAD/CAM systems and does not cover additional cutter characteristics such as spiralled blades or cross-cut geometry.

Key topics and technical requirements

  • Scope and shapes: Defines three head shapes commonly used in dental milling: cylindrical (side cutting only), cylindrical hemispherical, and conical truncated (side cutting only). Nominal diameters include commonly used sizes (for example 1.0 mm, 1.5 mm, 2.3 mm and conical sizes up to about 4.0 mm as listed in the standard tables).
  • Materials: Shanks shall be made of steel or other suitable material; the working part shall be tungsten carbide. Material selection and treatment are left to the manufacturer’s discretion.
  • Shank type: Shanks must be Type 2 or Type 4 in accordance with ISO 1797.
  • Dimensional tolerances: All dimensions are specified in millimetres with tolerances for diameter and length per the tables and figures in the standard.
  • Run-out tolerance: Total indicated run-out, measured per ISO 8325, shall not exceed 0.08 mm.
  • Sampling and acceptance: Type testing is specified - take 10 instruments at random from a validation batch. Pass/fail rules: if 8 or fewer pass the product fails; if 9 pass, test 10 additional instruments and all 10 must pass for compliance.
  • Measurement methods: Dimensional and run-out measurements must follow ISO 8325 and use validated measuring devices; manufacturers are responsible for instrument accuracy validation.
  • Designation and marking: Designation code numbers follow ISO 2157. Marking must show the manufacturer’s trade name/mark and the nominal size.

Applications and users

  • Dental laboratory managers and technicians: Use the standard to select compatible carbide cutters for milling machines and ensure consistent fit and function.
  • Manufacturers and suppliers: Apply the dimensional, material and marking requirements for product design, production, quality control and labeling.
  • Quality and regulatory personnel: Use sampling, test methods and run-out criteria for type testing and conformity documentation.
  • Test laboratories and procurement teams: Reference the standard when validating instruments and specifying purchase requirements.

Related standards

  • ISO 1797 - Shanks for rotary and oscillating instruments
  • ISO 2157 - Nominal diameters and designation codes for rotary instruments
  • ISO 8325 - Test methods for rotary instruments (measurement and run-out)
  • ISO 1942 - Dentistry vocabulary
  • ISO 6360-3 - Number coding system for rotary instruments (bibliographic reference)

Keywords: ISO 7787-3:2017, carbide cutters, dental milling, laboratory cutters, tungsten carbide, run-out 0.08 mm, dental laboratory standards, ISO dental standards.

Standard

ISO 7787-3:2017 - Dentistry -- Laboratory cutters

English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 7787-3:2017 - Médecine bucco-dentaire -- Fraises de laboratoire

French language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

ISO 7787-3:2017 is a standard published by the International Organization for Standardization (ISO). Its full title is "Dentistry - Laboratory cutters - Part 3: Carbide cutters for milling machines". This standard covers: ISO 7787-3:2017 specifies dimensional and other requirements for the three most commonly used carbide cutters for milling machines which are predominantly used in the dental laboratory. Other characteristics of laboratory cutters (for example, spiralled blades or cross-cut) are not covered by this document. Cutters intended for use with CAD/CAM systems are excluded from the scope of this document.

ISO 7787-3:2017 specifies dimensional and other requirements for the three most commonly used carbide cutters for milling machines which are predominantly used in the dental laboratory. Other characteristics of laboratory cutters (for example, spiralled blades or cross-cut) are not covered by this document. Cutters intended for use with CAD/CAM systems are excluded from the scope of this document.

ISO 7787-3:2017 is classified under the following ICS (International Classification for Standards) categories: 11.060.20 - Dental equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 7787-3:2017 has the following relationships with other standards: It is inter standard links to ISO 9182-1:2013, ISO 7787-3:1991. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO 7787-3:2017 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 7787-3
Second edition
2017-05
Dentistry — Laboratory cutters —
Part 3:
Carbide cutters for milling machines
Médecine bucco-dentaire — Fraises de laboratoire —
Partie 3: Fraises de laboratoire en carbure pour machines à fraiser
Reference number
©
ISO 2017
© ISO 2017, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2017 – All rights reserved

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms, definitions and symbols . 1
3.1 Terms and definitions . 1
3.2 Symbols . 2
4 Requirements . 2
4.1 Material . 2
4.2 Dimensions, shank and head shape . 2
4.3 Cylindrical, side cutting only . 2
4.4 Cylindrical, hemispherical . 3
4.5 Conical, truncated, side cutting only . 3
4.6 Run-out . 4
5 Sampling . 4
6 Measurement and test methods . 4
6.1 Dimensions . 4
6.2 Run-out . 4
6.3 Pass/fail evaluation . 4
7 Designation code number . 4
8 Marking . 5
Bibliography . 6
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO’s adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: w w w . i s o .org/ iso/ foreword .
...


NORME ISO
INTERNATIONALE 7787-3
Deuxième édition
2017-05
Médecine bucco-dentaire — Fraises de
laboratoire —
Partie 3:
Fraises de laboratoire en carbure pour
machines à fraiser
Dentistry — Laboratory cutters —
Part 3: Carbide cutters for milling machines
Numéro de référence
©
ISO 2017
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2017, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2017 – Tous droits réservés

Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes, définitions et symboles . 1
3.1 Termes et définitions . 1
3.2 Symboles . 2
4 Exigences . 2
4.1 Matériau . 2
4.2 Dimensions, queue et forme de la tête . 2
4.3 Cylindrique, coupe latérale uniquement . 2
4.4 Cylindrique, hémisphérique . 3
4.5 Tronconique, coupe latérale uniquement . 4
4.6 Excentricité . 4
5 Échantillonnage . 4
6 Méthodes de mesure et d’essai . 4
6.1 Dimensions . 4
6.2 Excentricité . 5
6.3 Évaluation de la conformité/non-conformité . 5
7 Désignation par numéro de code . 5
8 Marquage . 5
Bibliographie . 6
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier, de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/ directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www .iso .org/ brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’OMC concernant les obstacles techniques au commerce (OTC), voir le lien
suivant: Avant-propos — Informations supplémentaires.
Le présent document a été élaboré par le comité technique ISO/TC 106, Médecine bucco-dentaire, Sous-
comité SC 4, Instruments dentaires.
Cette deuxième édition annule et remplace la première édition (ISO 7787-3:1991) qui a fait l’objet d’une
révision technique visant à apporter les modifications suivantes:
a) les références normatives ont été mises à jour;
b) des définitions ont été ajoutées;
c) la numérotation des articles a été modifiée;
d) une Bibliographie a été ajoutée.
Une liste de toutes les parties qui constituent la série de normes ISO 7787 est donnée sur le site de
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...