IEC 61243-3:2014/COR2:2015
(Corrigendum)Corrigendum 2 - Live working - Voltage detectors - Part 3: Two-pole low-voltage type
Corrigendum 2 - Live working - Voltage detectors - Part 3: Two-pole low-voltage type
Corrigendum 2 - Travaux sous tension - Détecteurs de tension - Partie 3: Type bipolaire basse tension
General Information
Relations
Standards Content (Sample)
IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 61243-3 IEC 61243-3
Edition 3.0 2014-10 Édition 3.0 2014-10
Live working – Voltage detectors – Travaux sous tension – Détecteurs de tension
Part 3: Two-pole low-voltage type Partie 3: Type bipolaire basse tension
CO RRI G E NDUM 2
...
This May Also Interest You
IEC 61318:2021 This document defines methods to assess defects and to verify that products after the manufacturer process meet the requirements of the corresponding product standard.
The principles of assessment of defects for live working products are detailed in this document to assist product standard developers in prescribing the best means to achieve suitable quality of every finished tool, device and piece of equipment.
The following elements are not covered by the present document, but are included in each product standard:
– type tests;
– provisions and description for routine, sampling and acceptance tests;
– identification and classification of defects;
– risk analysis.
This document does not cover conformity assessment of commercial shipments or certifications.
This fourth edition cancels and replaces the third edition published in 2007. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) change of the purpose of the document from a prescriptive testing standard to a standard assisting the project team in the conformance to respective product standard.
b) introduction of conformance test, record of process, quality control documentation, adapted to the standard product.
c) change of prescribed sampling procedure to adapted sampling tests to the product standard.
d) suppression of the term “conformity assessment”.
e) Introduction of the term “verification method” replacing “conformity assessment application”.
- Standard33 pagesEnglish and French languagesale 15% off
IEC 61243-1:2021 is applicable to portable voltage detectors, with or without built-in power sources, to be used on electrical systems for voltages of 1 kV to 800 kV AC, and frequencies of 50 Hz and/or 60 Hz.
This document applies only to voltage detectors of capacitive type used in contact with the bare part to be tested, as a complete device including its insulating element or as a separate device, adaptable to an insulating stick which, as a separate tool, is not covered by this document (see 4.4.2.1 for general design).
Other types of voltage detectors are not covered by this document.
Self ranging voltage detectors (formally "multi range voltage detectors") are not covered by this document.
Some restrictions or formal interdictions on their use are applicable in case of switchgear of IEC 62271 series design, due to insulation coordination, on overhead line systems of electrified railways (see Annex B) and systems without neutral reference. For systems without neutral reference, the insulating level is adapted to the maximum possible voltage to the earth (ground).
Products designed and manufactured according to this document contribute to the safety of users provided they are used by persons trained for the work, in accordance with the hot stick working method and the instructions for use.
Except where otherwise specified, all the voltages defined in this document refer to values of phase-to-phase voltages of three-phase systems. In other systems, the applicable phase-to-phase or phase-to-earth (ground) voltages are used to determine the operating voltage.
This third edition cancels and replaces the second edition published in 2003 and Amend-ment 1:2009. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The scope is more precise, stating that only bare contact to the part to be tested is reliable for these contact voltage detectors. The rationale is that tests on painted or coated conductors have led to wrong indications, as this non-conductive paint or coat acts as a capacitor with different capacity according to the thickness. This capacity has an effect on the threshold voltage.
b) A contact probe is introduced as a new type of non-conductive contact electrode.
c) A new type "exclusively outdoor type" has been defined and implemented into the requirements and test procedure.
d) A selector for voltage and frequency is allowed if foreseeable misuse is excluded.
e) The marking for voltage detectors with low interference voltage has been made more precise.
f) The indication groups have been made more precise and requirements and tests for the "ready to operate state" and "stand-by state" added.
g) Requirements and tests for electromagnetic compatability have been implemented.
h) An example for good electrical connection for the tests is introduced.
- Standard160 pagesEnglish and French languagesale 15% off
- Standard1 pageEnglish and French languagesale 15% off
- Standard1 pageEnglish and French languagesale 15% off
IEC 60900:2018 is applicable to insulated, insulating and hybrid hand tools used for working live or close to live parts at nominal voltages up to 1 000 V AC and 1 500 V DC. The products designed and manufactured according to this document contribute to the safety of the users provided they are used by skilled persons, in accordance with safe methods of work and the instructions for use (where appropriate). This document has been prepared in accordance with the requirements of IEC 61477 where applicable. The products covered by this document may have an impact on the environment during some or all stages of its life cycle. These impacts can range from slight to significant, be of short term or long-term duration, and occur at the global, regional or local level. This document does not include requirements and test provisions for the manufacturers of the products, or recommendations to the users of the products for environmental improvement. This fourth edition cancels and replaces the third edition, published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of a third category of tools has been added, namely hybrid hand tools;
b) introduction of a new informative Annex A on examples of insulated, insulating and hybrid hand tools.
Key words: Live Working, Insulated, Insulating, Hand Tools
The contents of the corrigendum of January 2019 and May 2020 have been included in this copy.
- Standard180 pagesEnglish languagesale 15% off
- Standard118 pagesEnglish and French languagesale 15% off
IEC TR 61328:2017(E) provides recommendations for the selection and testing where necessary of conductor stringing equipment and accessory items used for the installation of bare and insulated overhead distribution conductors, bare overhead transmission conductors and overhead earth wires. This third edition cancels and replaces the second edition published in 2003 and IEC TR 61911:2003. It incorporates some technical changes to update equipment work methods and procedures, bringing them in line with the state of the art.
- Technical report73 pagesEnglish languagesale 15% off
- Standard10 pagesEnglish and French languagesale 15% off
- Standard10 pagesEnglish and French languagesale 15% off
IEC 61481-1:2014 is applicable to portable phase comparators of capacitive type to be used on electrical systems for voltages exceeding 1 kV a.c. and frequencies of 50 Hz and/or 60 Hz. This standard is applicable to single-pole phase comparators of capacitive type operating with a memory system up to 36 kV a.c., and two-pole phase comparators of capacitive type operating with a wireless connection up to 245 kV a.c. This standard is applicable to phase comparators of capacitive type used in contact with the bare conductive parts to be compared as a complete device including its insulating element or as a separate device, adaptable to an insulating stick which, as a separate tool, is not covered by this standard. A device that is designed to provide other functions than phase comparison is a different device and is not covered by this standard. For example a device designed to be also used as a voltage detector is not covered by this standard. This first edition, together with the first edition of IEC 61481-2, cancels and replaces the first edition of IEC 61481 published in 2001, Amendment 1:2002 and Amendment 2:2004. This edition constitutes a technical revision including the following major changes:
- split of the standard in two parts;
- extension of the scope to include two-pole phase comparators operating with a wireless connection up to 245 kV a.c.;
- review of the requirements for indication;
- introduction of a requirement for a new marking "LU" for limited use;
- and revision of existing annexes. The contents of the corrigendum of July 2015 have been included in this copy.
- Standard163 pagesEnglish and French languagesale 15% off